Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heterodyne”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Spectrograph stabilization using a single-delay interferometer on the Hale Telescope

We describe a technique for spectrograph stabilization useful when conventional mitigation techniques of vacuum tanks, thermal insulation, and laser frequency comb may be impractical, expensive, heavy, or bulky. This includes spectrographs on airborne platforms or mounted on telescopes where they suffer a changing gravity vector or other drifts. Placing a fixed-delay interferometer in series with a spectrograph forms an externally dispersed interferometer (EDI). This produces a uniform sinusoidal comb multiplying input spectrum, creating (through heterodyning) beats (moiré patterns). In Fourier space for low frequencies up to the comb frequency, the moiré generated signal counter-rotates to ordinary spectra under an unknown disperser wavenumber drift Δx. This generates a large negative feedback signal useful in a conceptual control loop, to converge rapidly to a stable spectrum and yield Δx. A modified EDI data analysis algorithm (“crossfading”) combines frequency-weighted moiré with conventional spectrum to cancel net output spectrum reaction to Δx. Needing only a single-delay, this is a practical improvement over prior crossfading analyses requiring multiple delays. We test crossfading on ThAr data near 4850 cm−1 taken on Hale telescope in an earlier project. In a single pass, we reduce drift 20 times. Using seven iterations, we reduce 0.5 cm−1 (31 km/s Doppler equivalent) drift to 4×10−7 cm−1 (2.5 cm/s). The interferometer delay can wander, because linearity of phase versus wavenumber interpolates science features between bracketing calibrating spectral references. Second, mathematically reversing the heterodyning effect doubles effective spectral resolution without changing disperser slit.

Erskine, David J [Lawrence Livermore National Labo↗

Doppler Lidar (DL) Instrument Handbook

The Doppler lidar (DL) is an active remote sensing instrument that provides range- and time-resolved measurements of radial velocity and attenuated backscatter. The principle of operation is similar to radar in that pulses of energy are transmitted into the atmosphere; the energy scattered back to the transceiver is collected and measured as a time-resolved signal. From the time delay between each outgoing transmitted pulse and the backscattered signal, the distance to the scatterer is inferred. The radial or line-of-sight velocity of the scatterers is determined from the Doppler frequency shift of the backscattered radiation. The DL uses a heterodyne detection technique in which the return signal is mixed with a reference laser beam (i.e., local oscillator) of known frequency. An onboard signal processing computer then determines the Doppler frequency shift from the spectra of the heterodyne signal. The energy content of the Doppler spectra can also be used to determine attenuated backscatter.

99 GENERAL AND MISCELLANEOUS↗

Laser Wavelength Shift from Splitters and Switches

The Detonation Science and Technology Group (Q-6) operates several photon Doppler velocimetry (PDV) systems as a diagnostic tool for measuring velocities in the 1–10 km/s range during high explosive (HE) detonation experiments. Q-6 uses “heterodyne” PDV systems that are produced by Traverse Solutions and Instrumentation, LLC (TS&I). These heterodyne systems combine wavelength (WL) tunable source and “reference” lasers with a WL offset of 10–100 pm from each other. Properly setting the source and reference WLs for an experiment can be critical for collecting the desired experimental data. The tunable lasers report WL readings in their control software, but these readings are based on a lookup table from a temperature reading and are not able to be calibrated. Therefore, recent test fire programs that require PDV as a diagnostic have also implemented requirements for monitoring the WL of the tunable lasers using a precision WL meter. To monitor the WL of several PDV lasers without disconnecting any patch fibers form the experimental setup, Q-6 developed a system splitters with a coupling ratio (%) of 99:1 and an optical switch with the switch output going to a single WL meter. A brief experiment was developed to determine if the splitters and/or switch introduced any WL bias into the readings. The purpose of this report is to document the system, the experiment, and its results.

42 ENGINEERING↗

In-situ x-ray scatter imaging of battery electrodes

A method and apparatus for in-situ x-ray scatter imaging of battery electrodes. An apparatus includes an X-ray source, a grid, the grid comprising stainless steel wires with uniform spacing, and a cell, the X-ray source directing a beam of energy through the metal grid and components of the cell, the cell blurring a previously sharp projection of grid wires on an image detector. A method includes providing a Spatial Frequency Heterodyne Imaging system, providing a grid, providing a cell, generating X-rays from the Spatial Frequency Heterodyne Imaging system that pass through components of the cell and the grid, and detecting a scatter image from the X-rays.

Rose-Petruck, Christoph↗

Phase-based velocity extraction method for photonic Doppler velocimetry with potential higher time resolution

We present an extension of the [Takeda et al., J. Opt. Soc. Am. 72, 156 (1982)] phase extraction method to heterodyne photonic Doppler velocimetry applications. The method yields results equivalent to those obtained by the short-time Fourier transform (STFT), while offering potential improvements in time resolution. Unlike STFT, which relies on window functions, such as the Hamming window, that emphasize central data points and diminish the influence of edges, the extended Takeda method utilizes all data uniformly. This uniform treatment allows for the derivation of empirical equations that directly relate velocity error to the actual time resolution rather than to the local analysis duration. The established equation provides a useful metric for both optimizing hardware configuration and guiding data analysis. Simulation and experimental results confirm that, for a given dataset, specifying a target time resolution yields consistent velocity errors for both methods. These findings underscore the Takeda method’s advantages, particularly its potential higher time resolution and reduced computational burden, making it a valuable tool for high-throughput applications such as laser dynamic compression experiments.

Computer simulation↗

First characterisation of the MAGO cavity, a superconducting RF detector for kHz–MHz gravitational waves

Heterodyne detection using microwave cavities is a promising method for detecting high-frequency gravitational waves (GWs) or ultralight axion dark matter. In this work, we report on studies conducted on a spherical 2-cell cavity developed by the MAGO collaboration for high-frequency GWs detection. Although fabricated around 20 years ago, the cavity had not been used since. Due to deviations from the nominal geometry, we conducted a mechanical survey and performed room-temperature plastic tuning. Measurements and simulations of the mechanical resonances and electromagnetic properties were carried out, as these are critical for estimating the cavity’s GW coupling potential. Based on these results, we plan further studies in a cryogenic environment. The cavity characterisation does not only provide valuable experience for a planned physics run but also informs the future development of improved cavity designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MiniCarb: a passive, occultation-viewing, 6U CubeSat for observations of CO 2 , CH 4 , and H 2 O

In this report we present the final design, environmental testing, and launch history of MiniCarb, a 6U CubeSat developed through a partnership between NASA Goddard Space Flight Center and Lawrence Livermore National Laboratory. MiniCarb’s science payload, developed at Goddard, was an occultation-viewing, passive laser heterodyne radiometer for observing methane, carbon dioxide, and water vapor in Earth’s atmosphere at ~1.6 µm s -1 . MiniCarb’s satellite, developed at Livermore, implemented their CubeSat Next Generation Bus plug-and-play architecture to produce a modular platform that could be tailored to a range of science payloads. Following the launch on 5 December 2019, MiniCarb traveled to the International Space Station and was set into orbit on 1 February 2020 via Northrop Grumman’s Cygnus capsule which deployed MiniCarb with tipoff rotation of about 20° s (significantly higher than the typical rate of 3° s -1 from prior CubeSats), from which the attitude control system was unable to recover resulting in a loss of power. In spite of this early failure, MiniCarb had many successes including rigorous environmental testing, successful deployment of its solar panels, and a successful test of the radio and communication through the Iridium network. This prior work and enticing cost (approximately $\$2$ M for the satellite and $\$$250 K for the payload) makes MiniCarb an ideal candidate for a low-cost and rapid rebuild as a single orbiter or constellation to globally observe key greenhouse gases.

47 OTHER INSTRUMENTATION↗

Pulse Length Monitor for Breakdown Diagnostics in THz and Mm-Wave Accelerators

The development of novel high-gradient accelerating structures operating at THz frequencies is critical for future free-electron lasers and TeV scale linear colliders. To reach high energies with reasonable length requires high accelerating gradients of ~100 MV/m. The main limitation to reaching these high-energy gradients is the vacuum RF breakdown phenomenon, which disrupts normal accelerator operations. For stable operations and to understand the breakdown microscopic dynamics, a new device capable of detecting the breakdown occurrences is required. In this paper, we provide the design of a pulse length monitor based on an analog to digital converter for fast signal digitization without the need to use high-speed digitizers to be used in a commercial mm-wave heterodyne spectrometer.

43 PARTICLE ACCELERATORS↗

Efficient Trainability of Linear Optical Modules in Quantum Optical Neural Networks

The existence of “barren plateau landscapes” for generic discrete-variable quantum neural networks, which obstructs efficient gradient-based optimization of cost functions defined by global measurements, would be surprising in the case of generic linear optical modules in quantum optical neural networks due to the tunability of the intensity of continuous variable states and the relevant unitary group having exponentially smaller dimension. We demonstrate that coherent light in m modes can be generically compiled efficiently if the total intensity scales sublinearly with m, and extend this result to cost functions based on homodyne, heterodyne, or photon detection measurement statistics, and to noisy cost functions in the presence of attenuation. Here, we further demonstrate efficient trainability of m mode linear optical quantum circuits for variational mean field energy estimation of positive quadratic Hamiltonians for input states that do not have energy exponentially vanishing with m.

47 OTHER INSTRUMENTATION↗

Dynamic Strength of Copper at High Pressures Using Pressure Shear Plate Experiments

Measurement of strength at high pressures is critical to understanding the behavior of materials subjected to extreme loading conditions. Recent developments have extended the pressure shear plate impact (PSPI) technique to the high-pressure regime. Such experiments provide a unique opportunity to extract the complete stress-strain behavior of materials at relatively high pressures. The modified technique includes a new fiber-optic heterodyne transverse velocity interferometer system and new analysis methods to account for the inelastic response of the anvil plates. In this study, PSPI experiments are conducted on oxygen-free high conductivity (OFHC) copper at pressures ranging from 10 to 43 GPa and at strain rates of ~10 5 s -1 . Complete stress-strain curves of copper are obtained using a hybrid methodology that relies on numerical simulations and particle velocity records gathered in these experiments. Experiments are conducted at similar pressures and strain rates using two types of anvils that undergo different levels of plastic strains: tool steel and tungsten carbide, to check the robustness of the hybrid method. The behavior of copper at these high pressures and strain rates is compared with previous literature data, and the effect of pressure and strain rate on the strength behavior of copper are discussed. Here, it was observed that the rate of change in yield strength change in pressure was 2.5 times the rate of change of shear modulus with pressure. The strength models that predict the response of copper at these extreme conditions are also examined and validated.

36 MATERIALS SCIENCE↗

Time-domain Brillouin scattering theory for probe light and acoustic beams propagating at an angle and acousto-optic interaction at material interfaces

A theory has been developed to interpret time-domain Brillouin scattering (TDBS) experiments involving coherent acoustic pulse (CAP) and light pulse beams propagating at an angle to each other. It predicts the influence of the directivity pattern of their acousto-optic interaction on TDBS signals when heterodyne detection of acoustically scattered light is in backward direction to incident light. The theory reveals relationships between the carrier frequency, amplitude and duration of acoustically induced ”wave packets” in light transient reflectivity signals, and factors such as CAP duration, widths of light and sound beams, and their interaction angle. It describes the transient dynamics of these wave packets when the light and CAP encounter material interfaces, and how the light scattering by the incident CAP transforms into scattering by the reflected and transmitted CAPs. The theory suggests that single-point TDBS experiments can determine not only depth positions of buried interfaces but also their local inclinations/orientations.

42 ENGINEERING↗

Extremely Slow Diffusion of Gold Nanoparticles under Confinement in Mesoporous Silica

Here, we report an X-ray photon correlation spectroscopy (XPCS) study of the mobility of colloidal gold nanoparticles with a diameter of approximately 4 nm in glycerol under confinement within the channels of SBA-15 mesoporous silica with pore diameters of approximately 6 and 12 nm. The XPCS correlation functions result from an effective heterodyne signal due to the mixing of the coherent scattering from the nanoparticles and the mesoporous silica. Over the range of wave vectors and hence length scales probed, the nanoparticle dynamics are well described by one-dimensional diffusion. The nanoparticle diffusivity varies with temperature in a manner expected based on the temperature-dependent viscosity of glycerol; however, the magnitudes of the diffusion coefficients are several orders of magnitude smaller than those of the nanoparticles in bulk glycerol. We consider mechanisms that might contribute to this reduction in diffusivity including enhancement in hydrodynamic drag under confinement, effects of nanoparticle adsorption to the pore walls, and slowing structural dynamics in glycerol due to the combination of the nanometer-scale confinement and the presence of the nanoparticles.

36 MATERIALS SCIENCE↗

Grain Growth and Coarsening Dynamics in a Compositionally Asymmetric Block Copolymer Revealed by X-ray Photon Correlation Spectroscopy

The dynamics of nanostructured soft materials crucially impact their associated macroscopic material properties, yet they are often difficult to measure due to spatiotemporal limitations of conventional instrumentation. Herein, we use X-ray photon correlation spectroscopy (XPCS) to directly observe particle-scale dynamics during grain growth and coarsening in a BCC- forming diblock polymer melt, with specific attention to the distribution of structural relaxation times associated with the interplanar (110) distance. Following sample quenching from the disordered state, these dynamical phenomena surprisingly exhibit little dependence on time and thermal quench depth. We posit that these relaxations stem from collective particle motions during grain rotation. We also observe unusual internally-referenced heterodyne correlations, which enable measurements of speed distributions within the sample. In this work, these speeds are significantly slower and appear at much longer annealing times than those previously reported during grain nucleation and growth in microphase separated block polymer melts. Drawing on analogies between polycrystalline hard and soft materials, we ascribe these speed distributions to misorientation-dependent grain boundary migration during ordered domain coarsening and anomalously fast, cooperative string-like particle motion along the grain boundaries. Thus, these coherent X-ray measurements provide new opportunities to interrogate grain boundary structure and dynamics in polycrystalline soft materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Suppressing Cation Migration in Triple-Cation Lead Halide Perovskites

Ion migration represents an intrinsic instability of metal halide perovskite solar cells. In this work, we show that triple-cation FA x MA y Cs 1–x–y PbI 3 [FA + = (NH 2 ) 2 CH + , MA + = CH 3 NH 3 + ] active layers with mixed orthorhombic, post-perovskite (δ ortho -CsPbI 3 ), and cubic perovskite (α) phases (i.e., α/δ-phase FA x MA y Cs 1–x–y PbI 3 ) exhibit improved cation stability against applied bias relative to pure α-phase perovskites (i.e., FA 0.85 Cs 0.15 PbI 3 and FA 0.76 MA 0.15 Cs 0.09 PbI 3 ). Infrared photothermal heterodyne imaging and time-of-flight secondary ion mass spectrometry are used to visualize exclusive α-phase perovskite lateral device A + cation accumulation (depletion) at perovskite negative (positive) electrode interfaces. The resulting compositional heterogeneities lead to degradation. Operational stability testing of solar cells reveals similar degradation behavior; α/δ-phase FA x MA y Cs 1–x–y PbI 3 lateral devices/solar cells, by contrast, show improved stabilities. Enhanced α/δ-FA x MA y Cs 1–x–y PbI 3 stability is rationalized by δortho-phase inclusions, acting as barriers through which A + cations do not easily migrate. This study thus provides new insights into cation migration in FA x MAyCs 1–x–y PbI 3 perovskites and suggests a materials design strategy toward suppressing cation instabilities in hybrid perovskites.

14 SOLAR ENERGY↗

Tunable Metasurface External-Cavity Quantum Cascade Lasers up to 5.74 THz

Vertical-external-cavity surface-emitting lasers based on amplifying quantum-cascade metasurfaces are demonstrated in the 5–6 THz range for the first time. Enhanced parasitic coupling to lossy surface modes requires updated design guidelines, while elevated losses and lower available material gain limit the scaling of the metasurface period from previous designs. A series of metasurface devices with varying periods employing both uniform and focusing metasurfaces is fabricated and characterized. Reducing the metasurface period below 70% of the free-space wavelength enables devices with superior performance, achieving pulsed operation up to 5.74 THz with peak output powers of 1.3 mW, maximum operating temperatures up to 83 K, and continuous-wave operation up to 54 K with 23 μW of output power. In the best case, single-mode tuning from 5.23–5.73 THz, which corresponds to a 9.1% fractional tuning, is realized with near-Gaussian far-field profiles maintained across the entire range. Finally, these results establish quantum cascade vertical-external-cavity surface-emitting lasers as promising candidates for high-frequency local oscillator applications in heterodyne spectroscopy.

gallium arsenide↗

Ultrafast infrared nano-imaging of far-from-equilibrium carrier and vibrational dynamics

Ultrafast infrared nano-imaging has demonstrated access to ultrafast carrier dynamics on the nanoscale in semiconductor, correlated-electron, or polaritonic materials. However, mostly limited to short-lived transient states, the contrast obtained has remained insufficient to probe important long-lived excitations, which arise from many-body interactions induced by strong perturbation among carriers, lattice phonons, or molecular vibrations. Here, we demonstrate ultrafast infrared nano-imaging based on excitation modulation and sideband detection to characterize electron and vibration dynamics with nano- to micro-second lifetimes. As an exemplary application to quantum materials, in phase-resolved ultrafast nano-imaging of the photoinduced insulator-to-metal transition in vanadium dioxide, a distinct transient nano-domain behavior is quantified. In another application to lead halide perovskites, transient vibrational nano-FTIR spatially resolves the excited-state polaron-cation coupling underlying the photovoltaic response. These examples show how heterodyne pump-probe nano-spectroscopy with low-repetition excitation extends ultrafast infrared nano-imaging to probe elementary processes in quantum and molecular materials in space and time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing magnon–magnon coupling in exchange coupled Y 3 Fe 5 O 12 /Permalloy bilayers with magneto-optical effects

We demonstrate the magnetically-induced transparency (MIT) effect in Y 3 Fe 5 O 12 (YIG)/Permalloy (Py) coupled bilayers. The measurement is achieved via a heterodyne detection of the coupled magnetization dynamics using a single wavelength that probes the magneto-optical Kerr and Faraday effects of Py and YIG, respectively. Clear features of the MIT effect are evident from the deeply modulated ferromagnetic resonance of Py due to the perpendicular-standing-spin-wave of YIG. We develop a phenomenological model that nicely reproduces the experimental results including the induced amplitude and phase evolution caused by the magnon–magnon coupling. Our work offers a new route towards studying phase-resolved spin dynamics and hybrid magnonic systems

36 MATERIALS SCIENCE↗

Kelvin probe force microscopy under ambient conditions

Kelvin probe force microscopy (KPFM) is a technique derived from atomic force microscopy that provides maps of surface potential or work function differences across material systems, with nanometre-scale resolution. KPFM is a useful tool for investigating electrical phenomena such as dipole orientation, interfacial charge transfer, charge accumulation, band bending and doping levels. This Primer aims to provide an overview of typical ambient-condition KPFM measurements, covering their underlying principles, experimental implementations and wide-ranging applications. Key KPFM variants, including amplitude and frequency modulation, heterodyne detection schemes and innovative open loop and pulsed force techniques, are discussed, with practical guidance on optimizing signal acquisition and reducing errors. Specialized approaches, such as time-resolved KPFM and multimodal KPFM, are discussed for their ability to capture dynamic charge processes and chemical information, respectively. Here, we highlight recent advances in KPFM applications, spanning metal alloys, soft matter, ferroelectrics, photovoltaics and 2D materials, showcasing its versatility across research domains. By addressing current limitations and identifying future opportunities, this Primer underscores the transformative potential of KPFM in advancing the understanding of nanoscale electrical phenomena.

Zahmatkeshsaredorahi, Amirhossein [Lehigh Univ., B↗