Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hg(OF)2”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Upper-Limit Charge Exchange Cross Sections for Mercury(+) on Molybdenum and Cesium(+) on Aluminum

Upper-limit charge exchange cross sections are calculated for Hg(+) on Mo and Cs(+) on Al. The cross sections are calculated from the polarization interaction at low ion energies (1 to 500 eV) and by assuming favorable curve crossings with a hard-core reaction radius at higher energies (500 eV to 10 keV). The cross sections for Hg(+) on Mo becomes greater than corresponding Hg Hg(+) resonance values at ion energies below 2 eV, whereas the Cs(+) Al values remain considerably lower than the Cs(+)Cs resonance value at all ion energies. It is also shown that charge exchange of slow Hg(+) with Mo may be important for spacecraft with electron bombardment thrusters.

Dugan, J. V., Jr.↗

Physics and Chemistry of Te and HgTe-based Ternary Melts

Historically, the theoretical treatment of the liquid phases has always been more difficult and complicated than that for solid and gas phases. A liquid has no lattice structure as crystalline solids and the atoms/molecules in the liquid can migrate through it relatively rapidly. On the other hand, it is also interacting with many other atoms/molecules so that the simplifications of the kinetic theory of gases cannot be employed. For more complicated liquids, such as the liquids of high ionicity and those containing hydrogen bonds and electric dipoles, the understanding is far from complete. At the same time, accurate information on the physics and chemistry of semiconductor melts is needed for the quantitative descriptions of the process of crystal growth from melt. The pre-crystallization phenomena in the liquid phase are critical because the properties of the grown crystals depend on the state and structure of the melt as well as the thermal history of the melt during solidification process. However, the data on the liquid phase, such as thermophysical properties of semiconductor melts are scarce, especially for the HgTe-based II-VI ternary compound semiconductors because of their high vapor pressure and extreme toxicity. Analysis of the thermophysical properties of the melt can provide information about structural transitions of the melt during the solidification process. From a broader point of view, the structure of liquids is much more complicated than the crystalline solids, especially the relaxation behavior through different thermal histories. The theory of hetero-phase fluctuations of liquids is applicable to any many-body systems including condensed-matter physics, field theory, physics of nuclear-matter, cosmology, biology and even sociology. This book summarizes the physics and chemistry from the experimental measurements and theoretical analyses of phase diagram, thermodynamic properties, density, thermal conductivity, viscosity, and electrical conductivity on the binary, pseudo-binary and ternary melts of the most advanced IR-detector material systems of HgCdTe and HgZnTe as well as the analyses of these results. The main objectives of this study are: (1) to provide the phase diagrams and thermodynamic properties of Hg-Cd-Te and Hg-Zn-Te systems through quantitatively fitting the experimental data by assuming an associated solution model for the liquid phase, (2) to experimentally measure the thermophysical properties of the Hg-Cd-Te and Hg-Zn-Te melts, including density, viscosity, electrical conductivity and thermal conductivity as functions of temperature and composition and (3) to enhance the fundamental knowledge of hetero-phase fluctuations and relaxation phenomena in the melts and extend our understanding of the solidification process in order to interpret the experimental results of crystal growth so as to improve the melt growth processes of the compound semiconductor. The physics and chemistry of Te and HgTe-based ternary melts were explored through the studies of the structural transformation during melting, the supercooling during solidification, the relaxation phenomena after rapid cooling of the melts and the metal-semiconductor transition in the melts through the analyses of electrical conductivity and Lorenz number. An in-depth study on the thermophysical properties and their time-dependent structural dynamic processes taking place in the vicinity of the solid-liquid phase transition of the narrow homogeneity range HgTe-based ternary semiconductors as well as the analysis of the homogenization process in the melt will also be presented.

Thermophysical properties↗

Investigations of the mechanisms by which lower body negative pressure (LBNP) improves orthostatic responses

Saline ingestion during LBNP is a counter measure proposed to improve orthostatic function during space flight. To understand the mechanism(s) responsible for this effect, body fluid, endocrine, and orthostatic responses (graded LBNP tests) were measured during bed rest (BR) and after 2 hr and 4 hr LBNP/saline treatments (-30 mm Hg and 1 liter of isotonic saline). PV (from I-125 and hematocrit measurements) decreased during BR but was restored to the pre-bed rest level (3157 +/- 161 ml) 20 hrs after both 2 hr (3109 +/- 146 ml) and 4 hr (3144 +/- 173 ml) LBNP. The heart rate response to graded LBNP tests was significantly improved after the 4 hr, but not after the 2 hr treatment. These results suggest PV expansion may be responsible for some improvement in orthostatic responses, but other mechanisms also must contribute.

Fortney, S. M.↗

A New Trapped Ion Clock Based on Hg-201(+)

There are two stable odd isotopes of mercury with singly ionized hyperfine structure suitable for a microwave clock: Hg-199(+) and Hg-201(+). Virtually all trapped mercury ion clocks to date have used the 199 isotope. We have begun to investigate the viability of a trapped ion clock based on Hg-201(+). We have measured the unperturbed frequency of the (S-2)(sub 1/2) F = 1, m(sub F) = 0 to (S-2)(sub 1/2) F = 2, m(sub F) = 0 clock transition to be 29.9543658211(2) GHz. In this paper we describe initial measurements with Hg-201(+) and new applications to clocks and fundamental physics.

ion traps↗

Blood flow dynamics in heart failure

BACKGROUND: Exercise intolerance in heart failure (HF) may be due to inadequate vasodilation, augmented vasoconstriction, and/or altered muscle metabolic responses that lead to fatigue. METHODS AND RESULTS: Vascular and metabolic responses to rhythmic forearm exercise were tested in 9 HF patients and 9 control subjects (CTL) during 2 protocols designed to examine the effect of HF on the time course of oxygen delivery versus uptake (protocol 1) and on vasoconstriction during exercise with 50 mm Hg pressure about the forearm to evoke a metaboreflex (protocol 2). In protocol 1, venous lactate and H+ were greater at 4 minutes of exercise in HF versus CTL (P<0.05) despite similar blood flow and oxygen uptake responses. In protocol 2, mean arterial pressure increased similarly in each group during ischemic exercise. In CTL, forearm blood flow and vascular conductance were similar at the end of ischemic and ambient exercise. In HF, forearm blood flow and vascular conductance were reduced during ischemic exercise compared with the ambient trial. CONCLUSIONS: Intrinsic differences in skeletal muscle metabolism, not vasodilatory dynamics, must account for the augmented glycolytic metabolic responses to moderate-intensity exercise in class II and III HF. The inability to increase forearm vascular conductance during ischemic handgrip exercise, despite a normal pressor response, suggests that enhanced vasoconstriction of strenuously exercising skeletal muscle contributes to exertional fatigue in HF.

NASA Discipline Cardiopulmonary↗

Functional Responses in Otolith Structures from Micro- to Hyper-Gravity

Vertebrates and invertebrates sense gravito-inertial acceleration by mechanoreceptors in the otolith and statolith organs, respectively. These structures consist of ciliated sensory hair cells surmounted by biomineral grains of calcium carbonate (CaCO3) called oto-orstato-conia. The grains provide mechanical loading of hair cell cilia, and their high density increases sensitivity to acceleration. A widely considered mechanism by which the animal responds to a chronic change in amplitude of gravity is a change in weight lending otoconia. In G, it is argued, the organism counters the loss of gravity by increasing CaCO3 production, thereby increasing otolith mass, as a means to increase system gain. In hypergravity (HG), the converse is argued. Here, we present the results obtained in 3 species exposed both to G and HG. Adult toadfish, Opsanus tau, were exposed to G in 2 short-duration shuttle missions and to 1.24 1.73G centrifugation for 1-32 days; re-adaptation was studied following 1-8 days of 1G. Results show a biphasic pattern in response to 1.73G: initial hypersensitivity, similar to that observed after G exposure, followed by transition to a significant decrease at 16-32 days. Recovery from HG exposure is 4-8 days. Next, we examined directly the responses of statocyst receptors in the land snail after exposure to G on two unmanned Russian Orbital missions and at 1.24G. Similar to vertebrate afferents snail receptors increased their sensitivity to tilt after G exposure, and decrease it after 16-32 days of HG. Two major pieces of information are still needed: vertebrate hair cell response to altered gravity and impact of longer duration exposures on sensory plasticity. To address the latter, we applied electron microscopic techniques to image otoconia mass obtained from 1) mice subjected to 91-days of weightlessness in the Mouse Drawer System (MDS) flown on International Space Station, 2) mice subjected to 91-days of 1.24G centrifugation on ground, and 3) mice flown on 2 short-duration orbital missions. Images indicate a clear restructuring of individual otoconia, suggesting deposition to the outer shell. Images from their HG counterparts indicate the converse - an ablation of the otoconia mass. For shorter duration exposures to weightlessness on 13-day shuttle missions, mice otoconia appear normal. Despite the permanence of 1G in evolution, the animal senses exposure to a novel, non-1G, environment and adaptive mechanisms are initiated - in the short term, compensation is likely confined to the peripheral sensory receptors, the brain or both. For longer exposures structural modifications of the endorgan may also result. Support Contributed By: NASA 03-OBPR-04 and 11-11_Omni_2-0002

Vertebrates↗

Dynamics of erythrocyte count, hemoglobin, and catalase activity in rat blood in hypokinesia, muscular activity and restoration

Tests were conducted to prove that muscular exertion (in this instance swimming) of different duration and intensity, as well as hypodynamia, result in an increase of hemoglobin and number of red blood cells in peripheral blood rats. Catalase activity increased with an increase in the duration of swimming, but only up to 6 hr; with 7-9 hr of swimming as well as in hypodynamia, catalase activity decreased. It was also observed that under hypodynamia as well as in 3, 5 and 6 hr exertion (swimming) the color index of blood decreased. Pressure chamber treatment (for 8 min each day for one week), alternating a 2 min negative pressure up to 35 mm Hg with 1 min positive pressure, increased the erythrocyte count and hemoglobin content.

Taneyeva, G. V.↗

Elemental abundance analyses with coadded Dominion Astrophysical Observatory spectrograms. II - The mercury-manganese stars 53 Tauri, Mu Leporis and Kappa Cancri

Elemental abundance analyses based on the coaddition of at least 10 2.4 A/mm Ila-O Dominion Astrophysical Observatory spectrograms have been performed for three mercury-manganese stars, 53 Tauri, Mu Leporis, and Kappa Cancri. These fine analyses show a greater degree of internal consistency than previous studies based on lower signal-to-noise data. Lines as weak as of order 3 mA are employed in these studies, and lines of atomic species not previously identified have been discovered. The status of 53 Tau as an anomalous member of this class is confirmed in that it lacks a Hg II 3984 A line even at the 2 mA level. Further, its surface gravity indicates it is less evolved than Mu Lep and Chi Cnc. Violations of the odd-even effect in the photospheric abundances of all three stars suggest that nonnuclear processes have operated in their atmospheres. Some of the values are substantially changed from their presumably initial solar values.

Adelman, Saul J.↗

Lower-body negative-pressure exercise and bed-rest-mediated orthostatic intolerance

PURPOSE: Supine, moderate exercise is ineffective in maintaining orthostatic tolerance after bed rest (BR). Our purpose was to test the hypothesis that adding an orthostatic stress during exercise would maintain orthostatic function after BR. METHODS: Seven healthy men completed duplicate 15-d 6 degrees head-down tilt BR using a crossover design. During one BR, subjects did not exercise (CON). During another BR, subjects exercised for 40 min.d(-1) on a supine treadmill against 50-60 mm Hg LBNP (EX). Exercise training consisted of an interval exercise protocol of 2- to 3-min intervals alternating between 41 and 65% (.)VO(2max). Before and after BR, an LBNP tolerance test was performed in which the LBNP chamber was decompressed in 10-mm Hg stages every 3 min until presyncope. RESULTS: LBNP tolerance, as assessed by the cumulative stress index (CSI) decreased after BR in both the CON (830 +/- 144, pre-BR vs 524 +/- 56 mm Hg.min, post-BR) and the EX (949 +/- 118 pre-BR vs 560 +/- 44 mm Hg.min, post-BR) conditions. However, subtolerance (0 to -50 mm Hg LBNP) heart rates were lower and systolic blood pressures were better maintained after BR in the EX condition compared with CON. CONCLUSION: Moderate exercise performed against LBNP simulating an upright 1-g environment failed to protect orthostatic tolerance after 15 d of BR.

NASA Center JSC↗

Carbon Monoxide Accumulation in the Extravehicular Mobility Unit

Introduction: Life support technology in large closed systems like submarines and space stations catalyzes carbon monoxide (CO) to carbon dioxide, which is easily removed. However, in a small system like the Extravehicular Mobility Unit (EMU), spacesuit, CO from exogenous (contaminated oxygen (O (sub 2) supply) and endogenous (human metabolism) sources will accumulate in the free suit volume. The free volume becomes a sink for CO that is rebreathed by the astronaut. The accumulation through time depends on many variables: the amount absorbed by the astronaut, the amount produced by the astronaut (between 0.28 and 0.34 moles per hour per kilogram)[1], the amount that enters the suit from contaminated O (sub 2), the amount removed through suit leak, the free volume of the suit, and the O (sub 2) partial pressure[2], just to list a few. Contamination of the EMU O (sub 2) supply with no greater than 1 part per million CO was the motivation for empirical measurements from CO pulse oximetry (SpCO) as well as mathematical modeling of the EMU as a rebreather for CO. Methods: We developed a first-order differential mixing equation as well as an iterative method to compute CO accumulation in the EMU. Pre-post measurements of SpCO (Rad-57, Masimo Corporation) from EMU ground training and on-orbit extravehicular activities (EVAs) were collected. Results: Initial modeling without consideration of the astronaut as a sink but only the source of CO showed that after 8 hours breathing 100 percent O (sub 2) with a 10 milliliter per minute (760 millimeters Hg at 21 degrees Centigrade standard) suit leak, an endogenous production rate of 0.23 moles per hour per kilogram for a 70 kilogram person with 42 liters (1.5 cubic feet) free suit volume resulted in a peak CO partial pressure (pCO) of 0.047 millimeters Hg at 4.3 pounds per square inch absolute (222 millimeters Hg). Preliminary results based on a 2008 model[3] with consideration of the astronaut as a sink and source of CO suggests that most of the rebreathed CO stays bound to hemoglobin and myoglobin and; therefore, pCO only increased to 0.002 millimeters Hg in the EMU. Hemoglobin saturation after 8 hours was an insignificant 0.4 percent compared to about 4 percent for cigarette smokers in the general population. This preliminary modeling result supplements 11 pre-post index finger SpCO measurements from EMU ground training (mean 0.5 percent versus 1 percent, probability equal to 0.41 from paired t-test) and 10 on-orbit pre-post EVAs (mean 1.5 percent versus 1.1 percent, probability equal to 0.17 from paired t-test) that showed no consistent increase, at least no increase outside the accuracy of the oximeter (1 percent display resolution with plus or minus 3 percent Standard Deviation). Discussion: Simulations continue, but a preliminary conclusion is that rebreathing endogenous CO accumulating in the EMU is not a serious medical issue during EVA. The absence of CO poisoning signs or symptoms following hundreds of EVAs is also good empirical evidence that corroborates the limited SpCO measurements and preliminary modeling results.

Conkin, J.↗

The thermal release of Hg from chondrites and their thermal histories

A quantitative treatment and implications of isothermal and linear heating data on Hg in meteorites are given as a sequel to a more qualitative analysis of meteorite thermal histories (Reed and Jovanovic, 1968). Studies of Hg in terrestrial metamorphic rocks establish that thermal events to which meteorites were subjected fall in the same temperature range, of 400-900 C, as exists during terrestrial metamorphism. Hg diffusion parameters based on data from the linear and isothermal heating experiments are calculated. The conclusions are: (1) Meteorites experienced thermal events of the same magnitude as those measured by primarily mineralogical metamorphic indicators reviewed by Dodd (1969); (2) no correspondence with mineralogical-petrological metamorphic grade is evident; (3) Hg data for some chondrites correlate with shock facies (non-thermal) indicators (Dodd and Jarosewich, 1979); (4) small Hg activation energies (6-14 kcal/mole) require that the meteorites must have been stored in closed systems until low temperatures were attained. Hg must be presented as an involatile mineral(s) or as a substituent in a host phase at temperatures below 100 C. Consistent with this interpretation is the fact that despite diffusion times of 100-1,000,000 years at 200 K, Hg was retained in small objects over cosmic ray exposure periods of a hundred-million years.

Jovanovic, S.↗

THE COMBINED USE OF LIQUID AND GASEOUS HELIUM TO PROVIDE NEAR ACTUAL SPACE ENVIRONMENT

Because of the extremely low density of the gas in Interplanetary space, the most important remaining mode of external heat transfer Is radiation. Studies of this phenomenon in its multiple ramifications are being made presently and will continue In both theoretical and experimental areas. These experiments should, most desirably, be made under conditions which duplicate outer space; otherwise, errors may be introduced which cannot be estimated and will only be discovered in the actual environment. Many facilities are presently available which will reproduce the space environment only approximately[1,2]. The facility which will be discussed here has as its goal, at least for the phenomena connected with radiation heat transfer, the provision of conditions in space as accurately as they are known. The conditions to be reproduced are: (1) the solar electromagnetic radiation spectrum; (2) the low pressure and density of space (∼10-14 mm Hg); and (3) the black radiation sink of space (4°K).

LIQUID HELIUM↗

Large neutron counters for supermonitors

Large neutron counters designed for the neutron supermonitor with an area of about 20 sq m are reported. Statistical accuracy of the counters is 0.1% per 2 hours. Dimensions: length--2 m; diameter--150 mm; pressure--200 mm Hg. The counters are filled with BF3 gas containing over 80% of B-10.

Blokh, Y. L.↗

Survival after aortic valve replacement for severe aortic stenosis with low transvalvular gradients and severe left ventricular dysfunction

OBJECTIVE: We sought to assess whether aortic valve replacement (AVR) among patients with severe aortic stenosis (AS), severe left ventricular (LV) dysfunction and a low transvalvular gradient (TVG) is associated with improved survival. BACKGROUND: The optimal management of patients with severe AS with severe LV dysfunction and a low TVG remains controversial. METHODS: Between 1990 and 1998, we evaluated 68 patients who underwent AVR at our institution (AVR group) and 89 patients who did not undergo AVR (control group), with an aortic valve area < or = 0.75 cm(2), LV ejection fraction < or = 35% and mean gradient < or = 30 mm Hg. Using propensity analysis, survival was compared between a cohort of 39 patients in the AVR group and 56 patients in the control group. RESULTS: Despite well-matched baseline characteristics among propensity-matched patients, the one- and four-year survival rates were markedly improved in patients in the AVR group (82% and 78%), as compared with patients in the control group (41% and 15%; p < 0.0001). By multivariable analysis, the main predictor of improved survival was AVR (adjusted risk ratio 0.19, 95% confidence interval 0.09 to 0.39; p < 0.0001). The only other predictors of mortality were age and the serum creatinine level. CONCLUSIONS: Among select patients with severe AS, severe LV dysfunction and a low TVG, AVR was associated with significantly improved survival.

NASA Discipline Cardiopulmonary↗

Hg(+) Frequency Standards

In this paper we review the development of Hg(+) microwave frequency standards for use in high reliability and continuous operation applications. In recent work we have demonstrated short-term frequency stability of 3 x 10(exp -14)/nu(sub tau) when a cryogenic oscillator of stability 2-3 x 10(exp 15) was used a the local oscillator. The trapped ion frequency standard employs a Hg-202 discharge lamp to optically pump the trapped Hg(+)-199 clock ions and a helium buffer gas to cool the ions to near room temperature. We describe a small Hg(+) ion trap based frequency standard with an extended linear ion trap (LITE) architecture which separates the optical state selection region from the clock resonance region. This separation allows the use of novel trap configurations in the resonance region since no optical pumping is carried out there. A method for measuring the size of an ion cloud inside a linear trap with a 12-rod trap is currently being investigated. At approx. 10(exp -12), the 2nd order Doppler shift for trapped mercury ion frequency standards is one of the largest frequency offsets and its measurement to the 1% level would represent an advance in insuring the very long-term stability of these standards to the 10(exp -14) or better level. Finally, we describe atomic clock comparison experiments that can probe for a time variation of the fine structure constant, alpha = e(exp 2)/2(pi)hc, at the level of 10(exp -20)/year as predicted in some Grand Unified String Theories.

Prestage, John D.↗

Electrostatic propulsion beam divergence effects on spacecraft surfaces, volume 2

The third phase of a program to develop understanding of and tolerance-level criteria for the deleterious effects of electrostatic rocket exhaust (Cs, Cs(+), Hg, Hg(+)) and materials of rocket construction impinging on typical classes of spacecraft (S/C) surfaces was completed. Models of ion engine effluents and models describing the degradation of S/C surfaces by these effluents are presented. Experimental data from previous phases are summarized and Phase 2 data and analysis are presented in detail. The spacecraft design implications of ion engine contaminants are discussed.

Hall, D. F.↗

Experiment 2: Vapor Transport Crystal Growth of Mercury Cadmium Telluride in Microgravity- USML-2

The new epitaxial growth experiments of Hg(l-x)Cd(x)Te on (100) CdTe substrates by chemical vapor transport (CVT), using HgI2 as a transport agent, were performed in the transient growth regime of this ternary, heteroepitaxial system at normal and reduced gravity during the USML-2 flight. The surface and interface morphology, the compositional and structural uniformity, and carrier mobility of the epitaxial layer and islands grown in microgravity are measurably improved relative to ground specimens. These observations demonstrate the effects of convective flow on the transport, deposition, and growth processes of this solid-vapor system even in the transient growth regime. The properties of the Hg(l-x)Cd(x)Te layer grown in a microgravity environment compare quite favorably to those of layers obtained by other techniques.

Wiedemeier, H.↗