Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Performance Building Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Typology of Quantum-Classical Faults

This paper introduces an extended taxonomy of faults specific to hybrid quantum-classical systems, addressing the unique challenges that arise from integrating quantum accelerators into high-performance computing (HPC) infrastructures. Building on the foundational fault classification by Avizienis et al., we incorporate fault types unique to quantum computing-such as qubit decoherence, spontaneous gate errors, and photon loss-alongside traditional and human-induced faults including development errors, operational mistakes, and malicious attacks. Our taxonomy classifies faults by their origin (natural vs. human-made), intent (accidental, deliberate non-malicious, or malicious), system boundaries (internal vs. external), and persistence (transient to permanent). We also explore how different architectural integration patterns-ranging from tight coupling to loose on-premise and cloud-based configurations-shape the manifestation and propagation of faults. These scenarios are analyzed in terms of timing mismatches, interface inconsistencies, and security threats such as data tampering and denial-of-service attacks. Through this fault-centric lens, we aim to support the co-design of dependable quantum-classical systems and highlight the critical role that integration strategies play in ensuring reproducibility, resilience, and security across hybrid computing platforms.

Giusto, Edorado [University of Naples Federico II,↗

LIGHT-bgcArgo-1.0: using synthetic float capabilities in E3SMv2 to assess spatiotemporal variability in ocean physics and biogeochemistry

Since their advent over 2 decades ago, autonomous Argo floats have revolutionized the field of oceanography, and, more recently, the addition of biogeochemical and biological sensors to these floats has greatly improved our understanding of carbon, nutrient, and oxygen cycling in the ocean. While Argo floats offer unprecedented horizontal, vertical, and temporal coverage of the global ocean, uncertainties remain about whether Argo sampling frequency and density capture the true spatiotemporal variability in physical, biogeochemical, and biological properties. As the true distributions of, e.g., temperature or oxygen are unknown, these uncertainties remain difficult to address with Argo floats alone. Numerical models with synthetic observing systems offer one potential avenue to address these uncertainties. Here, we implement synthetic biogeochemical Argo floats into the Energy Exascale Earth System Model version 2 (E3SMv2), which build on the Lagrangian In Situ Global High-Performance Particle Tracking (LIGHT) module in E3SMv2 (E3SMv2-LIGHT-bgcArgo-1.0). Since the synthetic floats sample the model fields at model run time, the end user defines the sampling protocol ahead of any model simulation, including the number and distribution of synthetic floats to be deployed, their sampling frequency, and the prognostic or diagnostic model fields to be sampled. Using a 6-year proof-of-concept simulation, we illustrate the utility of the synthetic floats in different case studies. In particular, we quantify the impact of (i) sampling density on the float-derived detection of deep-ocean change in temperature or oxygen and on float-derived estimates of phytoplankton phenology, (ii) sampling frequency and sea-ice cover on float trajectory lengths and hence float-derived estimates of current velocities, and (iii) short-term variability in ecosystem stressors on estimates of their seasonal variability.

54 ENVIRONMENTAL SCIENCES↗

The E3 Initiative

The Department of Energy’s Building Technologies Office is developing a national initiative focused on efficient and clean heating and cooling systems in residential and commercial buildings, making it easier to afford and install high-performance heat pump solutions.

HVAC, residential, commercial, Cold Climate Heat P↗

Development and evaluation of a multi-functional heat pump with embedded thermal storage

We developed and tested a novel multi-functional packaged vertical heat pump designed for multi-family buildings, capable of providing space cooling, space heating, water heating, and energy storage integration. The system employs a 3-speed scroll compressor and supports energy-efficient cooling and heating across different ambient conditions, while utilizing both indoor and outdoor air sources for water heating. Key performance metrics include an integrated energy efficiency ratio of 18.0 for cooling, a heating seasonal performance factor of 10.0, and a coefficient of performance (COP) of 2.1 for heating in cold climates down to −15 ˚C. Additionally, the system delivers an annual water heating COP greater than 4.0, with outstanding performance in combined space cooling and water heating modes, achieving a total COP of 8.8 by recovering condenser waste heat. The heat pump also demonstrated thermal energy storage capabilities, integrating with phase change material systems to store heating and cooling energy. Furthermore, this versatile system offers a promising solution for improving energy efficiency and sustainability in multi-family buildings, providing high-performance heating, cooling, and water heating across a range of climates.

COP↗

High-Throughput Computing: Case Study of Medical Image Processing Applications

HPC is designed for large-scale simulations using monolithic codes of tightly coupled processes highly optimized to deliver decreased time to solution. Medical image processing is not a traditional field of HPC. Similar to AI applications, medical image processing parses large datasets, typically multiple times, to support a variety of studies for classification, diagnosis or monitoring purposes. The convergence of AI, HPC and Big Data encouraged more fields using image processing to transition to HPC. However, not all applications benefit from the same optimizations. In this paper we focus on high throughput medical image processing applications that analyze a huge dataset of small MRI images and that require HPC systems to decrease the time of parsing the entire dataset and not individual MRIs. We show in this research the performance of running SLANT, an image processing application for a whole brain segmentation, on large-scale systems and highlight performance limitations. We present optimizations prioritizing throughput that exhibit a 3.5x speed-up on the Summit Supercomputer that can be used as a baseline for building a high-throughput execution framework for other HPC systems.

Predescu, Maria↗

Designing for Zero Energy and Zero Carbon on a Multi-Building Scale Using URBANopt: Preprint

Groundbreaking efforts are necessary to mitigate contributors increasing impacts of climate change. In parallel to inventing pioneering clean energy technologies it is even more fundamental to rethink designing energy systems within a singular facility and collectively to function as a district. Facilities should not be continuously passive by just consuming; there is a need to shift to perform more dynamically. Designing for zero energy and zero carbon on a multi-building scale can uncover opportunities for building energy efficiency, decarbonization, demand flexibility, and resiliency that are not accessible at an individual building scale. This approach can be challenging without innovative tools to evaluate the multitude of possibilities. As an investigated result, we highlight the use of a campus-scale energy modeling platform - URBANopt™ - for the expansion of the National Renewable Energy Laboratory's (NREL's) South Table Mountain campus in Golden, Colorado. Programmatic growth included the design of three new all-electric, zero-energy, and zero-carbon, mixed used buildings (a combination of research laboratories and office space). This investigation is critical to NREL reaching net-zero emissions for its operational footprint, which will occur in phases over the next decade. Leveraging URBANopt's capabilities, we evaluate 1) high-performance building energy efficiency and decarbonization measures, 2) 4th generation district heating and cooling (4th GDHC) systems, 3) optimized onsite generation and energy storage assets that meet zero-energy and zero-carbon targets at minimum life-cycle costs, and 4) cost-optimal distributed energy technology mixes, dispatch strategies, and associated capacities that increase resiliency to grid outages. This work demonstrates the use and capabilities of URBANopt through a real-world case study on a multi-building scale.

community energy model↗

BMX: Biological modelling and interface exchange

Abstract High performance computing has a great potential to provide a range of significant benefits for investigating biological systems. These systems often present large modelling problems with many coupled subsystems, such as when studying colonies of bacteria cells. The aim to understand cell colonies has generated substantial interest as they can have strong economic and societal impacts through their roles in in industrial bioreactors and complex community structures, called biofilms, found in clinical settings. Investigating these communities through realistic models can rapidly exceed the capabilities of current serial software. Here, we introduce BMX, a software system developed for the high performance modelling of large cell communities by utilising GPU acceleration. BMX builds upon the AMRex adaptive mesh refinement package to efficiently model cell colony formation under realistic laboratory conditions. Using simple test scenarios with varying nutrient availability, we show that BMX is capable of correctly reproducing observed behavior of bacterial colonies on realistic time scales demonstrating a potential application of high performance computing to colony modelling. The open source software is available from the zenodo repository https://doi.org/10.5281/zenodo.8084270 under the BSD-2-Clause licence.

97 MATHEMATICS AND COMPUTING↗

Uncertainty Quantification in High-Low Dynamic System Coupling Using RAVEN and TRANSFORM

This report demonstrates new functionality and applications stemming from the development of high fidelity to low fidelity (high-low) coupling for system simulations and to further explore the capabilities of RAVEN in the performance of uncertainty quantification in this kind of high-low coupled system models. The work builds from previous work on high-low coupling that utilized CTF, the high fidelity subchannel analysis code, with a low fidelity model built in TRANSFORM, the system analysis code, utilizing the Functional Mock-Up Interface (FMI)

97 MATHEMATICS AND COMPUTING↗

Uncertainty Quantification in High-Low Dynamic System Coupling using RAVEN and TRANSFORM

This work demonstrates new functionality and applications stemming from the development of high-fidelity to low-fidelity (high-low) coupling for system simulations and to further explore the capabilities of the Risk Analysis Virtual Environment (RAVEN) in the performance of uncertainty quantification in this kind of high-low coupled system models. The work builds from previous work on high-low coupling that utilized COBRA-TF (CTF), the high-fidelity subchannel analysis code, with a low fidelity model built in ORNL’s TRANSFORM, the system analysis code, utilizing the Functional Mock-Up Interface (FMI). Steady-state and transient analysis examples using the high/low coupled models generated from CTF and TRANSFORM/FMI are investigated. The workflows for both steady-state and transient coupled simulations are described. A steady-state parameter sweep and uncertainty analysis of the primary flow rates and reactor power are demonstrated. Likewise, a transient pump trip and power ramp sensitivity studies are also demonstrated. This work elucidates some of the potential benefits and future needs of using RAVEN for high/low system coupling analysis of energy systems. It also shows some of the difficulties that can be encountered in coupling system simulations.

Williams, Wesley↗

Exploring the Potential of Factory Installed Solar + Storage for Homebuilding

In recent years, an increasing number of grid disruptions due to intense weather events, natural disasters, and high peak loads resulted in increased interest in energy-resilient homes. Solar + storage (S+S) as an energy resiliency solution can provide continuity, onsite generation, and backup power during critical events. This project explored factory-installed solar plus storage (FISS) to overcome first cost and installation barriers and bring this resiliency solution to scale for single-family affordable and market-rate homebuyers. Guided by the principles of Lean manufacturing, the team explored how factories building high-performance zero energy modular homes can incorporate S+S into their existing construction system while improving quality and productivity and reducing the costs of the resilient energy system.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Are Deep Energy Retrofits in Commercial Buildings Including Window Upgrades?

U.S. Commercial buildings account for about 20% of total U.S. energy consumption. Because the thermal performance of windows significantly affects building energy efficiency and HVAC system performance, best practice guidance often includes window and envelope improvements in conjunction with HVAC upgrades to optimize energy use and improve occupant comfort. It is an open question, however, regarding how often these best practices are implemented in the field. This paper aims to address that gap by conducting a literature review and a series of interviews with commercial building auditing and management professionals to explore the factors that drive window retrofits in commercial buildings. The paper explores a range of case studies from deep energy retrofits across the globe, comparing projects with and without window retrofits. The primary goals of this review are to: (1) provide data from real-world case studies illustrating the role of windows in deep energy renovations and HVAC upgrades, (2) conduct retrofit cost analyses for windows and high-performance HVAC systems and (3) offer insights into how window upgrade decisions are made and when they are implemented as part of deep energy retrofits. Most of the retrofit studies focused exclusively on high performance HVAC upgrades without considering how window upgrades might further enhance the overall energy efficiency of commercial buildings. Interviews with building industry experts shed light on the key factors influencing deep energy retrofit decisions and what factors tip the scales in favor of including window measures with more comprehensive retrofit projects.

Cort, Katherine↗

Hestia-SWIFL: hourly anthropogenic fossil fuel CO2 and heat on the 2km WRF grid, version 1.1

The Hestia-SWIFL version 1.1 anthropogenic heat (AH) and fossil fuel CO2 (FFCO2) emissions data product represent emissions due to the combustion of fossil fuel and cement production within the state of Arizona from 2019 to 2022. This product was developed as part of the Southwest Urban Corridor Integrated Field Laboratory (SW-IFL) project, which aims to provide new knowledge and tools that address extreme heat, air quality, climate change and related urban environmental issues by integrating high-resolution observations, modeling, and civic engagement. The emissions are generated using a bottom-up/engineering approach and are tied to results generated by the Vulcan Project version 4, an effort to quantify space/time-resolved FFCO2 & AH emissions for the entire United States landscape. A large number of data sources are combined to best estimate the emissions at fine scales such as air quality emissions data, traffic flow data, building information, sociodemographic information, and fuel statistics. The AH product provides emissions for two emissions sources (transportation and point source emissions) in units of Watts per hour per square meter (W/m2) per year (annual files) or per hour (hourly files). The FFCO2 product provides emissions from nine individual emission sectors as well as the total, and in units of tons of carbon (tC) per grid cell per year or per hour. The output made available here places the native spatial resolution of the Hestia FFCO2 & AH emissions data product (points, lines, and polygons) into a regularized 2km x 2km grid at hourly and annual temporal resolutions, and stored in netCDF files. The exact spatial extent is defined by the ASU Weather Research Forecast (WRF) simulation grid. All data are processed using R/Python pm high-performance computing system. 2-27-2026 updates: Bugs in airport hourly profile (both AH and FFCO2) and building spatial patterns (FFCO2 only) were fixed. Hourly emissions are reprocessed for all years to reflect those changes.

54 ENVIRONMENTAL SCIENCES↗

Importance of Window Installation in Residential Building Envelopes Having Continuous External Insulation in Order to Realize Energy Efficiency

Residential buildings are one of the prime candidates in the United States for reducing energy consumption. Continuous exterior insulation (CEI) is being used increasingly often in residential buildings to improve energy efficiency. Windows constitute 15–40% of a building envelope and are the weakest component in energy performance. The installation of windows in walls with CEI has not been well evaluated. We identified four cases of installing windows in walls with CEI of 25–76 mm (1–3 in.) thickness and analyzed the energy loss between the window and wall interface (flanking loss), structural issues, air leakage, and moisture penetration. Thermal analysis showed that the insulation value (RSI) of the 305 mm (12 in.) perimeter wall surrounding a window decreased by 7.6–34.5% in the four cases when compared with the RSI of the wall without the window. A window installation method is proposed to address the issues likely to occur with installation methods currently being used in the field. An out-of-the-box installation system was also designed to achieve a better thermal performance, cost effectiveness, and structural performance in high-performance residential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing Exposures to Airborne Particles Through Improved Filtration: A High-Level Modeling Analysis

Indoor airborne particulates are well-known health hazards and filtration is one common method of reducing exposures. Based on our previously developed Regional Shelter Analysis methodology and parameters that characterize the existing US building stock, we perform a high-level assessment of the potential benefits of upgrading existing filters in furnace and in heating, ventilation, and air conditioning systems using off-the-shelf filters. We use three metrics to assess the improvement: Building Transmission Factor (a measure of protection against outdoor airborne particles), Indoor Normalized Time and Space Integrated Air Concentration (a measure of indoor exposure to indoor-origin airborne particles), and Building Exit Fraction (fraction of indoor airborne particles that are released to the outdoor atmosphere). We also discuss the potential reduction in regional exposures due to particles exiting the building and exposing downwind building occupants. Our modeling indicates that while buildings provide their occupants passive protection against airborne particulate hazards, including but not limited to PM 2.5 , PM 10 , and wildfire smoke; improving particle filtration efficiency may further improve this protection. The degree of improvement varies with particle size and building type. Of the building types studied, apartments are predicted to benefit most, with greater than a factor of 2 improvement (≥50% reduction in exposures) for 1 µm particle exposures when using MERV 7 to 12 rated filters. Non-residential buildings were notably less responsive to improved filtration but had the highest Building Exit Fractions with 30% to 40% of indoor airborne particles released to the outdoor atmosphere (apartment buildings only released 6% to 9%). Improvements predicted for single family homes were intermediate between apartments and non-residential buildings. Improvements in the Regional Exposure metric are larger, ranging from a factor of 2.5x to 10x for residences (when using MERV 7 to 12 rated filters) and up to 25x for large apartments with MERV 14 or 15 rated filters. The results of our modeling analysis are broadly consistent with the limited experimental data and modeling results available in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mitigating Moisture with High-R Walls

Energy-efficient building enclosures are key to decreasing energy load demand and enabling advanced space-conditioning systems for high-performance homes. One efficient enclosure design solution is high-R walls, which feature increased insulation levels as an effective solution for reducing air leakage and permeance of material layers. To increase builder confidence and encourage greater market adoption of high-R walls, Home Innovation Research Labs sought to demonstrate the long-term moisture performance of several high-R wall configurations in cold climate zones. The team monitored 22 newly constructed, occupied homes located throughout climate zones 4–7, where a substantial vapor drive to the exterior is present during the winter.

buildings↗

A novel lung-inspired 3D-printed desiccant-coated heat exchanger for high-performance humidity management in buildings

Offering an independent humidity management method for buildings, desiccant-coated heat exchangers (DCHXs) are deemed a promising approach to improve the overall energy efficiency of air conditioning (AC) systems. State-of-the-art DCHXs, however, are bound with conventional HX topologies either providing limited desiccant-air interfacial areas or introducing excessive pressure drop penalties. In this paper a novel 3D-printed DCHX concept inspired by the bronchi arrangement of a human lung is introduced to address the shortcomings inherent in existing DCHX designs. The proposed lung-inspired DCHX utilizes two intertwined bicontinuous flow networks enabling highly efficient heat and mass transfer characteristics for augmented adsorption and regeneration processes at low pressure drop penalties. While the first network evenly distributes an incoming air stream through the entire volume of the lung-inspired DCHX, the second network volumetrically splits a cooling water stream within and through the first network. Effects of various parameters including air flow rate, outdoor air humidity ratio, and regeneration temperature on dehumidification performance and energy efficiency of the proposed lung-inspired DCHX were investigated. Experimental results indicated the proposed lung-inspired 3D-printed DCHX outperforms existing DCHX systems by demonstrating an excellent balance between a high volumetric adsorption rate and a low pressure drop penalty. The volumetric adsorption rate of the proposed lung-inspired DCHX technology is 54.8 g/m 3 -s, a more than two-fold improvement compared with state-of-the-art DCHX systems. Additionally, the lung-inspired DCHX offers high thermal energy efficiency of 56% at a low regeneration temperature of 40 °C. Therefore, the proposed lung-inspired 3D-printed DCHX offers a new solid-desiccant-based air dehumidification pathway for next-generation high-performance AC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Engineering activatable promoters for scalable and multi-input CRISPRa/i circuits

Dynamic, multi-input gene regulatory networks (GRNs) are ubiquitous in nature. Multilayer CRISPR-based genetic circuits hold great promise for building GRNs akin to those found in naturally occurring biological systems. We develop an approach for creating high-performing activatable promoters that can be assembled into deep, wide, and multi-input CRISPR-activation and -interference (CRISPRa/i) GRNs. By integrating sequence-based design and in vivo screening, we engineer activatable promoters that achieve up to 1,000-fold dynamic range in an Escherichia coli-based cell-free system. These components enable CRISPRa GRNs that are six layers deep and four branches wide. We show the generalizability of the promoter engineering workflow by improving the dynamic range of the light-dependent EL222 optogenetic system from 6-fold to 34-fold. Additionally, high dynamic range promoters enable CRISPRa systems mediated by small molecules and protein–protein interactions. We apply these tools to build input-responsive CRISPRa/i GRNs, including feedback loops, logic gates, multilayer cascades, and dynamic pulse modulators. Our work provides a generalizable approach for the design of high dynamic range activatable promoters and enables classes of gene regulatory functions in cell-free systems.

42 ENGINEERING↗

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F↗