Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Voltage Insulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Nondestructive Evaluation of Rexolite Insulators for the Purpose of Monitoring the Structural Health of Particle Accelerator

Rexolite is a cross-linked polystyrene plastic with stable electrical properties into the gigahertz frequency range. The ability to withstand high voltage makes Rexolite one of the most used materials as insulators for particle accelerators. Although, Rexolite’s poor outgassing performance relative to traditional vacuum materials such as stainless steel or aluminum deems the necessity to treat Rexolite prior to its use as insulators. Insulators are mandatory for an accelerator system because a uniform electric field is required to ensure the alignment of the accelerated particles. Furthermore, to operate properly, a particle accelerator is required to maintain a high vacuum or even an ultrahigh vacuum. Although, because outgassing is the major contributor to the gas load of a vacuum system, Rexolite insulators with uncontrolled outgassing characteristics can severely damage the particle accelerator. Disassembly and reassembly of a complex system like a particle accelerator is also time consuming.

36 MATERIALS SCIENCE↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Role of electrolyte in silicon electrolyte interface stabilization

Transition metal ion dissolution was long thought to be the reason for poor cycling performance in Lithium ion batteries cycled to a high voltage, but since the anode SEI is electrochemically insulating, the mechanism for transition metal mediated SEI decomposition in unclear. Our results show that acidic species such as F 2 PO 2 H generation on the cathode side and their subsequent crossover reactions with the SEI components damaging it could more likely be a major factor to capacity fade.

25 ENERGY STORAGE↗

Thermal and Reliability Characterization of an Epoxy Resin-Based Double-Side Cooled Power Module

Wide-Band Gap (WBG) power devices have become a promising option for high-power applications due to the superior material properties over traditional Silicon. To not limit WBG devices’ mother nature, a rugged and high-performance power device packaging solution is necessary. This study proposes a Double-Side Cooled (DSC) 1.2 kV half-bridge power module having dual epoxy resin insulated metal substrate (eIMS) for solving convectional power module challenges and providing a cost-effective solution. The thermal performance outperforms traditional Alumina (Al2O3) Direct Bonded Copper (DBC) DSC power module due to moderate thermal conductivity (10 W/mK) and thin (120 mm) epoxy resin composite dielectric working as the IMS insulation layer. This novel organic dielectric can withstand high voltage (5 kVAC @ 120 μm) and has a Glass Transition Temperature (Tg) of 300°C, which is suitable for high-power applications. In the thermal-mechanical modeling, the organic DSC power module can pass the thermal cycling test over 1,000 cycles by optimizing the mechanical properties of the encapsulant material. In conclusion, this article not only proposes a competitive organic-based power module but also a methodology of evaluation for thermal and mechanical performance.

42 ENGINEERING↗

Neutron generation using pyroelectric crystals

A method for producing a neutrons includes producing a voltage of negative polarity of at least −100 keV on a surface of a deuterated or tritiated target in response to a temperature change of a pyroelectric crystal of less than about 40° C., the pyroelectric crystal having the deuterated or tritiated target coupled thereto, pulsing a deuterium ion source to produce a deuterium ion beam, accelerating the deuterium ion beam to the deuterated or tritiated target, and directing the ion beam onto the deuterated or tritiated target to make neutrons using at least one element of the following: a voltage of the pyroelectric crystal and a high gradient insulator (HGI) surrounding the pyroelectric crystal. The accelerating of the deuterium ion beam is achieved by using an ion accelerating mechanism comprising a pyroelectric stack accelerator having a first thermal altering mechanism for changing a temperature of the pyroelectric stack accelerator.

Tang, Vincent↗

A study on sub-bandgap photoexcitation in nitrogen- and boron-doped diamond with interdigitated device structure

Diamond is an ultrawide-bandgap semiconductor suitable for high power devices that require high current carrying capacity, high blocking voltages, and smaller form factors. We investigated various diamond structures for extrinsic photoconductive semiconductor switches, including an insulating high-pressure high-temperature type Ib (highly nitrogen-doped) substrate, a chemical vapor deposited (CVD) type IIa (unintentionally doped) substrate, a CVD grown semiconducting boron-doped epilayer on a type IIa substrate, and boron-implanted type Ib and IIa substrates. Using these samples, we fabricated and characterized planar interdigitated photoconductive switches with 30 μm, electrode gaps. 532 and 1064 nm Nd:YAG laser pulses with energies up to 3.5 mJ/pulse were used to trigger the switches. Photoresponses were measured at bias voltages ranging from 10 to 100 V, corresponding to electric fields of 3.3–33 kV/cm. In this field range, the type Ib device exhibited the highest average on/off-state current ratio, on the order of 10 11 , when triggered with 0.8 mJ/pulse, 532 nm laser pulses. However, only the CVD grown boron-doped epilayer and boron implanted IIa devices showed decent sensitivity to 1064 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nickel-incorporated Oxide Composites for Fiber-Optic Based Gas Sensing

Numerous high-value applications within the energy sector involve environmental conditions that are incompatible with traditional sensor technology due to degradation of electrical interconnects, packaging, or the sensors themselves. These can include chemically harsh conditions, high temperature operation, or the presence of electromagnetic interference due to high voltage. The fiber optic platform, constructed of robust, electrically insulating glass or single crystal oxides, offers a versatile and often low cost per node solution to this problem, especially with the integration of distributed sensing techniques such as optical time-domain and frequency-domain reflectometry (OTDR, OFDR). A major challenge of gas and chemical sensing on the optical fiber platform is the fabrication of robust and stable sensing materials that interact quickly and reversibly to the presence of the target analytes. In this work, we discuss the utilization of nickel-incorporated oxides on evanescent-field optical fiber sensors for gas sensing under harsh conditions relevant to multiple energy infrastructure applications. This paper will discuss a Ni/GDC (Ni / Gd-doped ceria) based sensing layer targeting conditions relevant for high-temperature (up to at least 800 oC) hydrogen sensing applications (e.g., for operation within a solid oxide fuel cell or electrolyzer). The impact of hydrogen at elevated temperatures on the optical properties of Ni/GDC will be shown and the material mechanisms for the optical response will be discussed.

gas sensors↗

Nickel-incorporated Oxide Composites for Fiber-Optic Based Gas Sensing

Numerous high-value applications within the energy sector involve environmental conditions that are incompatible with traditional sensor technology due to degradation of electrical interconnects, packaging, or the sensors themselves. These can include chemically harsh conditions, high temperature operation, or the presence of electromagnetic interference due to high voltage. The fiber optic platform, constructed of robust, electrically insulating glass or single crystal oxides, offers a versatile and often low cost per node solution to this problem, especially with the integration of distributed sensing techniques such as optical time-domain and frequency-domain reflectometry (OTDR, OFDR). A major challenge of gas and chemical sensing on the optical fiber platform is the fabrication of robust and stable sensing materials that interact quickly and reversibly to the presence of the target analytes. In this work, we discuss the utilization of nickel-incorporated oxides on evanescent-field optical fiber sensors for gas sensing under harsh conditions relevant to multiple energy infrastructure applications. This paper will discuss a Ni/GDC (Ni / Gd-doped ceria) based sensing layer targeting conditions relevant for high-temperature (up to at least 800oC) hydrogen sensing applications (e.g., for operation within a solid oxide fuel cell or electrolyzer). The impact of hydrogen at elevated temperatures on the optical properties of Ni/GDC will be shown and the material mechanisms for the optical response will be discussed.

gas sensors↗

Statistical characterization of high voltage vacuum surface flashover with gapped and ungapped anodes

This manuscript reports the experimental study of a novel vacuum high-voltage (HV) feedthrough geometry with a recessed anode triple junction (ATJ) relevant to large-scale pulsed power systems. It is shown experimentally that introducing a vacuum gap between the insulator–anode interface and recessing the ATJ farther away from the cathode triple junction significantly enhances high voltage (HV) vacuum surface flashover hold-off. The results for “first pulse” and “consecutive pulse” tests are reported. The physical mechanisms contributing to the electrical failure of this feedthrough geometry appear to be unique to this geometry. These findings show the potential to allow for HV vacuum surface flashover geometries with significantly improved electrical characteristics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Partial discharge suppression in high voltage solid-state devices

Devices, methods and techniques are disclosed to suppress electrical discharge and breakdown in insulating or encapsulation material(s) applied to solid-state devices. In one example aspect, a multi-layer encapsulation film includes a first layer of a first dielectric material and a second layer of a second dielectric material. An interface between the first layer and the second layer is configured to include molecular bonds to prevent charge carriers from crossing between the first layer and the second layer. The multi-layer encapsulation configuration is structured to allow an electrical contact and a substrate of the solid-state device to be at least partially surrounded by the multi-layer encapsulation configuration.

Sampayan, Stephen↗

Partial discharge suppression in high voltage solid-state devices

Devices, methods and techniques are disclosed to suppress electrical discharge and breakdown in insulating or encapsulation material(s) applied to solid-state devices. In one example aspect, a multi-layer encapsulation film includes a first layer of a first dielectric material and a second layer of a second dielectric material. An interface between the first layer and the second layer is configured to include molecular bonds to prevent charge carriers from crossing between the first layer and the second layer. The multi-layer encapsulation configuration is structured to allow an electrical contact and a substrate of the solid-state device to be at least partially surrounded by the multi-layer encapsulation configuration.

Sampayan, Stephen↗

High‐Performance Zinc Tin Oxide TFTs with Active Layers Deposited by Atomic Layer Deposition

Abstract New deposition techniques for amorphous oxide semiconductors compatible with silicon back end of line manufacturing are needed for 3D monolithic integration of thin‐film electronics. Here, three atomic layer deposition (ALD) processes are compared for the fabrication of amorphous zinc tin oxide (ZTO) channels in bottom‐gate, top‐contact n‐channel transistors. As‐deposited ZTO films, made by ALD at 150–200 °C, exhibit semiconducting, enhancement‐mode behavior with electron mobility as high as 13 cm 2 V −1 s −1 , due to a low density of oxygen‐related defects. ZTO deposited at 200 °C using a hybrid thermal‐plasma ALD process with an optimal tin composition of 21%, post‐annealed at 400 °C, shows excellent performance with a record high mobility of 22.1 cm 2 V –1 s –1 and a subthreshold slope of 0.29 V dec –1 . Increasing the deposition temperature and performing post‐deposition anneals at 300–500 °C lead to an increased density of the X‐ray amorphous ZTO film, improving its electrical properties. By optimizing the ZTO active layer thickness and using a high‐ k gate insulator (ALD Al 2 O 3 ), the transistor switching voltage is lowered, enabling electrical compatibility with silicon integrated circuits. This work opens the possibility of monolithic integration of ALD ZTO‐based thin‐film electronics with silicon integrated circuits or onto large‐area flexible substrates.

Allemang, Christopher R.↗

Sudden-Discharge Cycling Characteristics and Millisecond Dynamic Behaviors of a HTS Stainless-Steel Insulated Double-Pancake Coil With Thin Copper Plates

We have tested an intermediate-sized HTS stainless-steel (co-wound) insulated double pancake coil (~132 turns per coil) and discovered dynamic effects during sudden discharge on both millisecond and second scales. For soft break, the power supply is turned off suddenly but the shunt resistor (164 milliohm) is still connected; for hard break, a high voltage contactor is used to suddenly open the circuit so that the leads are completely open. Hard break is dangerous to traditionally insulated LTS magnets, but the SS-insulated HTS DPC retained integrity over ¡80 charge-discharge cycles. Voltage decay curves for soft and hard breaks are studied on short and long timescales. On long timescales, we observe the expected exponential decay and measure the time constant to calculate contact resistance. On short timescales, we observe highly dynamic effects: a hyper-exponential decay suggesting that the inductance or contact resistance is suddenly changing with time, likely an indication of the RL circuit forming. Moreover, peak voltage immediately (ms) after the sudden discharge were collected and compared. It is found that the peak voltage in soft-discharge is proportional to the applied current, while the those in hard-break has a unique pattern and tends to stay flat even though the applied current increases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Online Detection of Inter-Turn Winding Faults in Single-Phase Distribution Transformers Using Smart Meter Data

Turn-to-turn faults between primary windings due to insulation degradation are a major cause of distribution transformer failure, and occur due to high levels of stress such as overloading and overheating. An additional consequence of these faults is an increased voltage on the transformer secondary due to effective change in turns ratio. This paper develops a novel method for early detection of insulation degradation and subsequent inter-turn winding failure by monitoring the transformer secondary voltage. The algorithm is based on a cumulative sum (CUSUM) statistic and compares voltages on neighbouring transformers to flag degrading assets. Results obtained from simulation as well as experimental data show that smart meter measurements can be utilized to achieve very high detection accuracy while keeping costs low. Here, the paper also demonstrates the validity of the algorithm in the presence of measurement noise, residential solar power injection etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LANSCE Module 1 Capacitor Room Failure [Slides]

At ~3:30 am on Sunday, high-voltage line in capacitor room overheated to the extent that the poly insulating material caught fire and dripped melted insulation onto equipment below. LAFD responded and, per pre-incident planning, waited for AOT personnel to respond to the area. AOT personnel, safed equipment and waited with LAFD for fire to “burn out”. Using an IWD, AOT personnel safely re-entered the area after conducting hazards analysis and engaging SMEs, re: controls for combustion products and COVID-19 hazards. Recovery action took several days with a focus on getting it right. Beam re-start decisions were made with impacted organizations and considering AOTRFE personnel.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Assessment and In-Situ Monitoring of Insulated Gate Bipolar Transistors in Power Electronic Modules: Preprint

Insulated gate bipolar transistor (IGBT) power modules are devices commonly used for switching of high voltages and currents. Usage and environmental conditions can cause these power modules to degrade over time, and this gradual process may eventually lead to catastrophic failure of the device. This degradation process may cause some early performance symptoms related to the state of health of the power module, making it possible to detect reliability degradation of the IGBT module. Testing can be used to accelerate this process, permitting a rapid determination of whether specific declines in device reliability can be characterized. In this study, thermal cycling was conducted on multiple power modules simultaneously in order to assess the effect of thermal cycling on the degradation of the power module. In-situ monitoring of temperature was performed from inside each power module using high temperature thermocouples. Device imaging and characterization was performed along with temperature data analysis, to assess failure modes and mechanisms within the power modules. While the experiment was aimed to assess the potential damage effects of thermal cycling on die attach, results indicated that wirebond degradation was the life limiting failure mechanism.

33 ADVANCED PROPULSION SYSTEMS↗

Assessment of EPRI’s Tan Delta Approach to Manage Cables in Submerged Environments: Statistical Review of EPRI Data

Research conducted by the Electric Power Research Institute (EPRI) and other research institutions have concluded that water-trees are one of the leading degradation mechanisms that contribute to the loss of dielectric insulation strength in medium-voltage cable insulating materials in wet or submerged environments. The electrochemical reactions are caused by the combined effect of water presence and relatively high electrical stress. Records of cable failures provided by the licensees in response to Generic Letter (GL) 2007-01 (NRC 2007) have called into question the reliability of medium voltage cables in wetted or submerged environments. EPRI’s dissipation factor or Tan Delta testing guidelines and acceptance criteria have been adopted by most nuclear power plant operators as the primary tool for condition monitoring of medium voltage cables in wet or submerged environments. EPRI has been collecting member data since late 2009 to analyze and provide feedback to members, validate the EPRI-developed acceptance criteria guidelines, support analysis of test results, recommend appropriate actions for the "action required" category, and gather candidate cables for EPRI-sponsored forensic research on causes for insulation degradation. EPRI has collected data from 37 nuclear sites, which represent 44 operating units. The test results have been organized by insulation type, such as cross-linked polyethylene (XLPE); butyl rubber; black, pink, and brown ethylene-propylene rubber (EPR); and compact insulation (black and pink EPR)1. The data have been analyzed, and follow-up information was obtained from members for “action required” test results. EPRI has also performed correlations between Tan Delta tests and the information gathered under the EPRI forensic research on medium-voltage cables. In addition, EPRI has developed guidance by cable insulation type on how to systematically analyze Tan Delta test results. The analysis described here reviewed the two primary EPRI reports (EPRI 3002000557 and EPRI 3002005321) as well as two precedent EPRI reports (EPRI 1028262 and EPRI 1021070) that were cited in the primary reports. The principal results and conclusions from the project analyses are provided.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Study of the Heater-Coil Electrical Insulation for the HL-LHC Low Beta Quadrupoles

In the framework of the HL-LHC project, the present LHC low-β superconducting quadrupoles will be substituted with higher performance Nb 3 Sn magnets (MQXF) with 11.4 T coil peak field. MQXF coils are impregnated with epoxy resin to reduce risk of stress concentration on the brittle conductor. The magnet quench protection is provided by CLIQ and quench heaters to ensure a redundant system. Quench heaters are impregnated with the coils in order to have suitable thermal contact with them, and to prevent the hot spot temperature from exceeding 350K during normal operation in case of a quench. Quench heaters are insulated from the coil by S-2 Glass and polyimide. Here, the test of the first MQXF prototype (4 m long) MQXFAP1 was stopped by a coil-to-ground short circuit triggered by a heater-to-coil short. This issue triggered a root analysis of the causes of this short. Here we prove that the use of a non-conforming cloth in coil impregnation, further weakened by non-conforming high voltage test, has triggered the shorts. Moreover, we present an analysis of the heater-to-coil insulation strength, showing the role of blistering phenomena and how they are triggered by a combination of magnet powering and heater firing.

43 PARTICLE ACCELERATORS↗