Search NASA⌕ Search

SEARCH · Search NASA

Results for “High gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Prototyping high-gradient mm-wave accelerating structures

We present single-cell accelerating structures designed for high-gradient testing at 110 GHz. The purpose of this work is to study the basic physics of ultrahigh vacuum RF breakdown in high-gradient RF accelerators. The accelerating structures are π-mode standing-wave cavities fed with a TM 01 circular waveguide. The structures are fabricated using precision milling out of two metal blocks, and the blocks are joined with diffusion bonding and brazing. The impact of fabrication and joining techniques on the cell geometry and RF performance will be discussed. First prototypes had a measured Q 0 of 2800, approaching the theoretical design value of 3300. The geometry of these accelerating structures are as close as practical to singlecell standing-wave X-band accelerating structures more than 40 of which were tested at SLAC. This wealth of X-band data will serve as a baseline for these 110 GHz tests. Furthermore, the structures will be powered with short pulses from a MW gyrotron oscillator. RF power of 1 MW may allow an accelerating gradient of 400 MeV/m to be reached.

43 PARTICLE ACCELERATORS↗

High-gradient performance of a prototype accelerator cavity for a 3 GeV proton radiography booster

This paper reports the design, fabrication, and results of the high-gradient conditioning and testing for a two-cell, π -mode, standing wave normal-conducting prototype booster cavity for the proposed 3 GeV proton linac upgrade at Los Alamos Neutron Science Center. Increasing the energy of proton beam from the existing 800 MeV to 3 GeV will improve resolution of the proton radiography by up to 10 times. The proposed energy boost can be achieved with a compact normal-conducting high-gradient radio-frequency (rf) linac section. The C-band section of the booster linac was designed with optimized-shaped copper accelerator cavities with distributed rf coupling. A short two-cell test prototype structure was designed for the frequency of 5.712 GHz, fabricated, and tested at the C-band Engineering Research Test Facility in New Mexico (CERF-NM) at Los Alamos National Laboratory. The maximum klystron power coupled into the test structure was 8.3 MW with 1 μ s pulse length and 100 Hz repetition rate. The breakdown probabilities were recorded as functions of the accelerating gradient and peak surface fields. Operation of the test cavity at accelerating gradients of up to 100 MV / m was demonstrated. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

On the use of high-gradient magnetic force field in capturing airborne particles

Airborne particles in the environment are generally smaller than a couple of microns. Use of magnetic force to collect aerosol particles thus has not been popular as the other means. There are billions of airborne particles emitted by a host of man-made sources with the particle size smaller than 1 µm and possess some magnetic susceptibility. We are thus interested in the use of high-gradient magnetic collection to extract the magnetic fraction in an aerosol population. Here in this study, we reported that the magnetic force is the dominant force in collection of ferromagnetic particles of mobility equivalent size larger than or equal to 50 nm in a high-gradient permanent-magnetic aerosol collector, while the diffusiophoretic force is responsible for particles smaller than 10 nm. Both forces compete for particles in between these two sizes in the magnetic aerosol collector designed for this study. To enable a wide-range effective collection of aerosol particles across entire size spectrum from a few nanometers to tens of a micron, the ORNL-designed high-gradient magnetic collector would require the use of an engineered matrix. Thus, the matrix design for a specific application becomes application specific. Irrespective of the collection efficiency, the use of permanent magnets to collect magnetic particles is feasible and also highly selective because it tunes into the magnetic susceptibility of the particles as well as the size. Lastly, the use of permanent magnets enables the collector to be operated at a minimal power requirement, which is a critical factor in long-term field operation.

54 ENVIRONMENTAL SCIENCES↗

Collection of Aerosol Particles in a Single-Stage, High Gradient Magnetic Collector

The collection of aerosol particles that have magnetic components such as actinides, Co/Ni/Fe, brass, and alloys are of interest in the nuclear industry and for regulatory applications. The collection of these particles is important for monitoring and a number of collection approaches have been developed based on separations mechanisms including size, mass, electrical or thermal properties. In this work, we present the performance of a single-stage, high gradient magnetic collector with a nickel foam matrix for removing airborne magnetic particles. The collection efficiencies for two different particle size regimes and compositions (NaCl and Fe 3 O 4 below 200 nm and SiO 2 and Fe 3 O 4 at 1-2 μm) were measured to assess the performance of the magnetic collector. The high gradient magnetic collector did not remove nanosized magnetic Fe 3 O 4 particles any more effectively than non-magnetic NaCl particles. However, in the larger size range, the collector more efficiently removed Fe 3 O 4 particles compared to SiO 2 with a collection efficiency of 99% compared to 84% for SiO 2 . The removal mechanism could be attributed to both filtration and the high gradient magnetic field.

54 ENVIRONMENTAL SCIENCES↗

High gradient off-axis coupled C-band Cu and CuAg accelerating structures

Here, we report the high gradient testing results of two single-cell off-axis coupled standing wave accelerating structures. Two brazed standing wave off-axis coupled structures with the same geometry were tested: one made of pure copper (Cu) and one made of a copper–silver (CuAg) alloy with a silver concentration of 0.08%. A peak surface electric field of 450 MV/m was achieved in the CuAg structure for a klystron input power of 14.5 MW and a 1 μs pulse length, which was 25% higher than the peak surface electric field achieved in the Cu structure. The superb high gradient performance was achieved because of the two major optimizations in the cavity's geometry: (1) the shunt impedance of the cavity was maximized for a peak surface electric field to accelerating gradient ratio of ~2 for a fully relativistic particle, and (2) the peak magnetic field enhancement due to the input coupler was minimized to limit pulse heating. These tests allow us to conclude that C-band accelerating structures can operate at peak fields similar to those at higher frequencies while providing a larger beam iris for improved beam transport.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Test Results of a High-Gradient 2.856-GHz Negative Harmonic Accelerating Waveguide

We report the high-gradient tests results of a novel traveling wave accelerating structure for β=0.3 based on a novel approach of operating at the first negative spatial harmonic. Accelerating gradients of 50 MV/m and peak electric fields of 160 MV/m were achieved in a single structure consisting of 15 coupled cells during tests at the advanced photon source. This work was performed by RadiaBeam, in collaboration with the Argonne National Laboratory, as a part of a Research and Development Program for the development of an ultrahigh-gradient linear accelerator, the Advanced Compact Carbon Ion Linac, for hadron therapy.

42 ENGINEERING↗

Ab initio investigation of elastic properties of dilute Cu alloys for high-gradient accelerating structures

The elastic properties and solid solution strengthening of several Cu alloys that may be promising for high gradient applications were studied using ab initio calculations based on density functional theory. Specifically, the temperature and solute concentration dependence of elastic properties including bulk and shear moduli, thermal expansion coefficient, and heat capacity of these alloys were calculated. We found that the bulk and shear moduli are linearly dependent on the solute concentration in the dilute regime and change significantly for different Cu alloys. The thermal expansion coefficient and heat capacity are comparatively less sensitive to solute concentrations. Solid solution strengthening is observed to be linearly correlated with the change of lattice parameter of Cu. This work provides an in-depth understanding of the elastic properties of Cu alloys, which is key for predicting their performance at high gradient in normal conducting accelerating structures.

36 MATERIALS SCIENCE↗

High Gradient Two-Beam Electron Accelerator

A high-gradient two-beam electron accelerator structure using detuned cavities is described. A self-consistent theory based on a circuit model is presented to calculate idealized acceleration gradient, transformer ratio, and efficiency for energy transfer from the drive beam to the accelerated beam. Experimental efforts are being carried out to demonstrate this acceleration concept.

43 PARTICLE ACCELERATORS↗

Technique for constructing high gradient insulators

A process for constructing a high-tensile strength, high-gradient insulator (HGI) may include stacking alternating layers of conductors and insulators, and vacuum pressure potting the stacked layers onto an insulating rod. The process may also include post machining the stacked layers to form a complete assembly of the HGI.

Watson, Scott Avery↗

Planned High-gradient Flat-beam-driven Dielectric Wakefield Experiments at the Fermilab’s Advanced Superconducting Test Accelerator

In beam driven dielectric wakefield acceleration (DWA), high-gradient short-wavelength accelerating fields are generally achieved by employing dielectric-lined waveguides (DLWs) with small aperture which constraints the beam sizes. In this paper we investigate the possibility of using a low-energy (50-MeV) flat beams to induce high-gradient wakes in a slab-symmetric DLW. We demonstrate via numerical simulations the possibility to produce axial electric field with peak amplitude close to 0.5 GV/m. Our studies are carried out using the Fermilab's Advanced Superconducting Test Accelerator (ASTA) photoinjector beamline. We finally discuss a possible experiment that could be performed in the ASTA photoinjector and eventually at higher energies.

43 PARTICLE ACCELERATORS↗

Fabrication of high gradient insulators by stack compression

Individual layers of a high gradient insulator (HGI) are first pre-cut to their final dimensions. The pre-cut layers are then stacked to form an assembly that is subsequently pressed into an HGI unit with the desired dimension. The individual layers are stacked, and alignment is maintained, using a sacrificial alignment tube that is removed after the stack is hot pressed. The HGI's are used as high voltage vacuum insulators in energy storage and transmission structures or devices, e.g. in particle accelerators and pulsed power systems.

36 MATERIALS SCIENCE↗

Ultra-High Gradient Compact S-Band Linac for Laboratory and Industrial Applications

There is growing demand from the industrial and research communities for high gradient, compact RF accelerating structures. The commonly used S-band SLAC-type structure has an operating gradient of only about 20 MV/m; while much higher operating gradients (up to 70 MV/m) have been recently achieved in X-band, as a consequence of the substantial efforts by the Next Linear Collider (NLC) collaboration to push the performance envelope of RF structures towards higher accelerating gradients. Currently however, high power X-band RF sources are not readily available for industrial applications. Therefore, RadiaBeam Technologies is developing a short, standing wave S-band structure which uses frequency scaled NLC design concepts to achieve up to a 50 MV/m operating gradient at 2856 MHz. The design and prototype commissioning plans are presented.

43 PARTICLE ACCELERATORS↗

In Situ observation of dark current emission in a high gradient rf photocathode gun

Undesirable electron field emission (also known as dark current) in high gradient rf photocathode guns deteriorates the quality of the photoemission current and limits the operational gradient. To improve the understanding of dark current emission, a high-resolution (~100 μm) dark current imaging experiment has been performed in an L-band photocathode gun operating at ~100 MV/m of surface gradient. Scattered strong emission areas with high current have been observed on the cathode. The field enhancement factor β of selected regions on the cathode has been measured. Finally, the postexaminations with scanning electron microscopy and white light interferometry reveal the origins of ~75% strong emission areas overlap with the spots where rf breakdown has occurred.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SLIM, Short-pulse Technology for High Gradient Induction Accelerators

A novel short-pulse concept (SLIM) suited to a new generation of a high gradient induction particle accelerators is described herein. It applies advanced solid state semiconductor technology and modern microfabrication techniques to a coreless induction method of charged particle acceleration first proven on a macro scale in the 1960's. Because this approach avoids use of magnetic materials there is the prospect of such an accelerator working efficiently with accelerating pulses in the nanosecond range and, potentially, at megahertz pulse rates. The principal accelerator section is envisioned as a stack of coreless induction cells, the only active element within each being a single, extremely fast (subnanosecond) solid state opening switch: a Drift Step Recovery Diode (DSRD). Each coreless induction cell incorporates an electromagnetic pulse compressor in which inductive energy developed within a transmission-line feed structure over a period of tens of nanoseconds is diverted to the acceleration of the passing charge packet for a few nanoseconds by the abrupt opening of the DSRD switch. The duration of this accelerating output pulse--typically two-to-four nanoseconds--is precisely determined by a microfabricated pulse forming line connected to the cell. Because the accelerating pulse is only nanoseconds in duration, longitudinal accelerating gradients approaching 100 MeV per meter are believed to be achievable without inciting breakdown. Further benefits of this approach are that, (1) only a low voltage power supply is required to produce the high accelerating gradient, and, (2) since the DSRD switch is normally closed, voltage stress is limited to a few nanoseconds per period, hence the susceptibility to hostile environment conditions such as ionizing radiation, mismatch (e.g. in medical applications the peak beam current may be low), strong electromagnetic noise levels, etc is expected to be minimal. Finally, we observe the SLIM concept is not limited to linac applications; for instance, it could be employed to both accelerate the beam and to stabilize the superbunch mode of operation in circular track machines.

43 PARTICLE ACCELERATORS↗

Record high-gradient SRF beam acceleration at Fermilab

Here, many modern and future particle accelerators employ high gradient superconducting RF (SRF) to generate beams of high energy, high intensity and high brightness for research in high energy and nuclear physics, basic energy sciences, etc. In this paper we report the record performance large-scale SRF system with average beam accelerating gradient matching the International Linear Collider (ILC) specification of 31.5 MV m –1 . Design of the eight cavity 1.3 GHz SRF cryomodule, its performance without the beam and results of the system commissioning with high intensity electron beam at Fermilab Accelerator Science and Technology (FAST) facility are presented. We also briefly discuss opportunities for further beam studies and tests at FAST including those on even higher gradient and more efficient SRF acceleration, as well as exploration of the system performance with full ILC-type beam specifications.

43 PARTICLE ACCELERATORS↗

High Gradient Accelerating Structures for Carbon Therapy Linac

Carbon therapy is the most promising among techniques for cancer treatment, as it has demonstrated significant improvements in clinical efficiency and reduced toxicity profiles in multiple types of cancer through much better localization of dose to the tumor volume. RadiaBeam, in collaboration with Argonne National Laboratory, are developing an ultra-high gradient linear accelerator, Advanced Compact Carbon Ion Linac (ACCIL), for the delivery of ion-beams with end-energies up to 450 MeV/u for 12C6+ ions and 250 MeV for protons. In this paper, we present a thorough comparison of standing and travelling wave designs for high gradient S-Band accelerating structures operating with ions at varying velocities, relative to the speed of light, in the range 0.3-0.7. In this paper we will compare these types of accelerating structures in terms of RF, beam dynamics and thermo-mechanical performance.

Kutsaev, Sergey↗

Study on Electropolishing of N-Doped Niobium Surfaces and 650 MHz Cavity for High-Gradient Performance

This presentation provides an overview of the latest studies on electropolishing (EP) of nitrogen-doped niobium surfaces and 650 MHz cavities. The first study focuses on optimizing EP parameters to achieve a pit-free surface on N-doped niobium, highlighting the effects of process conditions on surface pitting and suggesting strategies for mitigation. The second study investigates the EP of 650 MHz cavities to achieve high-gradient performance comparable to that of 1.3 GHz niobium SRF cavities. Additionally, an example of a 650 MHz single-cell cavity is presented, demonstrating its record-high gradient achieved through optimized EP conditions.

43 PARTICLE ACCELERATORS↗