Search NASA⌕ Search

SEARCH · Search NASA

Results for “Histogram”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Register-Like Storage Block Used as Histograms, Cluster Buffers, and Hough Transform Accumulators for HEP Trigger Systems

In high energy physics experiment trigger systems, block memories are utilized for various purposes, especially in binned searching algorithms. In these algorithms, the storages are demanded to perform like a large set of registers. The writing and reading operation must be performed in single clock cycle and once an event is processed, the memory must be globally reset. These demands can be fulfilled with registers but the cost of using registers for large memory is unaffordable. Another common requirement is the boundary coverage feature during reading process. Additionally, when a memory bin is addressed, the stored contents in the addressed bin and its neighboring bin must be output simultaneously. In this paper, a register-like block storage design scheme is described, which allows updating memory locations in single clock cycle, reading two adjacent bins, and effectively refreshing entire memory within a single clock. The implementation and test results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method of predicting the mean lung dose based on a patient's anatomy and dose-volume histograms

The aim of this study was to propose a method to predict the minimum achievable mean lung dose (MLD) and corresponding dosimetric parameters for organs-at-risk (OAR) based on individual patient anatomy. For each patient, the dose for 36 equidistant individual multileaf collimator shaped fields in the treatment planning system (TPS) was calculated. Based on these dose matrices, the MLD for each patient was predicted by the homemade DosePredictor software in which the solution of linear equations was implemented. The software prediction results were validated based on 3D conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) plans previously prepared for 16 patients with stage III non–small-cell lung cancer (NSCLC). For each patient, dosimetric parameters derived from plans and the results calculated by DosePredictor were compared. The MLD, the maximum dose to the spinal cord (D{sub max} {sub cord}) and the mean esophageal dose (MED) were analyzed. There was a strong correlation between the MLD calculated by the DosePredictor and those obtained in treatment plans regardless of the technique used. The correlation coefficient was 0.96 for both 3D-CRT and VMAT techniques. In a similar manner, MED correlations of 0.98 and 0.96 were obtained for 3D-CRT and VMAT plans, respectively. The maximum dose to the spinal cord was not predicted very well. The correlation coefficient was 0.30 and 0.61 for 3D-CRT and VMAT, respectively. The presented method allows us to predict the minimum MLD and corresponding dosimetric parameters to OARs without the necessity of plan preparation. The method can serve as a guide during the treatment planning process, for example, as initial constraints in VMAT optimization. It allows the probability of lung pneumonitis to be predicted.

61 RADIATION PROTECTION AND DOSIMETRY↗

Flat-histogram extrapolation as a useful tool in the age of big data

In this work, we review recent work by the authors to revisit the concept of extrapolating thermodynamic properties of classical systems using statistical mechanical principles. Specifically, we discuss how the combination of these principles with biased sampling techniques enables the prediction of free energy landscapes and other detailed information, such as structural properties, of the system in question. Remarkably accurate estimates of physical properties across a broad range of conditions have been achieved using this approach, greatly reducing the number of simulations needed to explore a given system's behaviour. While approximate, these extrapolations significantly amplify the amount of reasonably accurate information that can be extracted from simulations enabling a small set of them to feed data-intensive regression algorithms such as neural networks. Thus, this extrapolation methodology represents a useful tool for performing tasks such as high-throughput screening of physical properties, optimising force field parameters, exploring equilibrium phase behaviour, and enabling theory-guided data science for these systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SHIVER - Spectroscopy HIstogram Visualizer for Event Reduction

Visualizing data from neutron scattering experiments is the first step in understanding the physics. The program is intended to generate and plot cuts and slices, through the four dimensional single crystal inelastic datasets, measured on direct geometry neutron spectrometers at the Spallation Neutron Source (ARCS, CNCS, HYSPEC, SEQUOIA).

Savici, AndreiT [Oak Ridge National Laboratory (OR↗

Method of characterizing residual stress in ferromagnetic materials using a pulse histogram of acoustic emission signals

The invention is a method and apparatus for characterizing residual uniaxial stress in a ferromagnetic test member by distinguishing between residual stresses resulting from positive (tension) forces and negative (compression) forces by using the distinct and known magnetoacoustic (MAC) and a magnetoacoustic emission (MAE) measurement circuit means. A switch permits the selective operation of the respective circuit means.

Namkung, Min↗

A histogram-based technique for rapid vector extraction from PIV photographs

A new analysis technique, performed totally in the image plane, is proposed which rapidly extracts all available vectors from individual interrogation regions on PIV photographs. The technique avoids the need for using Fourier transforms with the associated computational burden. The data acquisition and analysis procedure is described, and results of a preliminary simulation study to evaluate the accuracy of the technique are presented. Recently obtained PIV photographs are analyzed.

Humphreys, William M., Jr.↗

Boundary detection evaluation

Illustrative embodiments are directed to a method and apparatus for evaluating boundary detection in an image. A processed image is received, wherein a detected boundary of an image of an object is identified in the processed image. A Radon transform is applied to the processed image for a plurality of angles to form a processed image histogram corresponding to the detected boundary for each of the plurality of angles. The processed image histogram for each of the plurality of angles and a corresponding ground truth histogram for each of the plurality of angles is normalized to provide a normalized processed image histogram and a normalized ground truth histogram for each of the plurality of angles, wherein the ground truth histogram corresponds to a ground truth boundary of the object for a corresponding angle. An indication of the edges of the normalized processed image histogram for each of the plurality of angles is plotted to form a boundary detection evaluation visualization.

Wantuch, Andrew C.↗

Boundary detection evaluation

Illustrative embodiments are directed to a method and apparatus for evaluating boundary detection in an image. A processed image is received, wherein a detected boundary of an image of an object is identified in the processed image. A Radon transform is applied to the processed image for a plurality of angles to form a processed image histogram corresponding to the detected boundary for each of the plurality of angles. The processed image histogram for each of the plurality of angles and a corresponding ground truth histogram for each of the plurality of angles is normalized to provide a normalized processed image histogram and a normalized ground truth histogram for each of the plurality of angles, wherein the ground truth histogram corresponds to a ground truth boundary of the object for a corresponding angle. An indication of the edges of the normalized processed image histogram for each of the plurality of angles is plotted to form a boundary detection evaluation visualization.

Wantuch, Andrew C.↗

Texture analysis of small renal cell carcinomas at MDCT for predicting relevant histologic and protein biomarkers

Purpose: To assess CT texture features of small renal cell carcinomas (≤ 4cm) for association with key pathologic features including protein biomarkers. Methods: Quantitative CT texture analysis (CTTA) of small renal cancers (≤ 4cm) was performed on non-contrast and portal venous phase abdominal MDCT scans with an ROI drawn at the largest cross-sectional diameter of the tumor using commercially available software. Texture parameters including mean pixel attenuation, the standard deviation (SD) of the pixel distribution histogram, entropy, the mean of positive pixels, the skewness (i.e., asymmetry) of the pixel histogram, kurtosis (i.e., peakness) of the pixel histogram, and the percentage of positive pixels were correlated with pathologic data from surgical resection, including histology and nuclear grade, as well as microarray analysis in a subset (n = 40) including Ki67 index, CRP, and neovascularization (CD105/CD31). Results: Portal venous phase images were available in 249 patients (105 women, 144 men; mean age, 56.7 years) with tumors ≤ 4cm (mean, median, range, ± SD; 2.66, 2.60, 0.3–4.0 ± 0.85 cm). CT texture features of standard deviation, mean of the positive pixels, and entropy of the pixel histogram were significantly associated with histologic cell type (clear vs. non-clear; p < 0.001). Entropy and mean of the positive pixels also showed an association with nuclear grade, although not statistically significant. In the microarray analysis subset, kurtosis of the pixel histogram was associated with CD105/CD31 (p = 0.05). SD also showed some association with CD 105 positivity (p = 0.02) and CAIX expression (p = 0.01). Non-contrast CT images were available in 174 patients (72 women, 102 men; mean age, 57.5 years). Although the association with histology was not as strong as on the portal venous phase, in the subset of patients with microarray data, SD was found to correlate with CRP (p = 0.08), kurtosis with CRP (p = 0.004), CD105/CD31 (p = 0.002), and with Ki 67 index (p < 0.001). Conclusion: CT texture features were significantly associated with important histopathologic features in small renal cancers. These non-invasive measures can be performed retrospectively and may provide useful information when determining follow-up and treatment of small renal cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cosmic-ray exposure history of ordinary chondrites

The exposure age histograms for H-, L-, and LL-chondrites are discussed. None of these histograms is consistent with a continuous delivery of asteroidal material to the earth, as the observed T(e) histograms clearly disagree with expected exponential distributions for a variety of orbital lifetimes. It is concluded that T(e) histograms are dominated by stochastic events and that the continuous supply of asteroidal material can account only for a minor background of the T(e) histograms. An attempt is made to identify major collisional levels among the major classes of ordinary chondrites in order to estimate the frequency of stochastic events. Orbital maturity in the inner solar system is documented by the p.m./total fall ratio among observed meteorite falls. All chondrite classes exhibit a uniform ratio of 2/3 except type H5 chondrites, which reveal a 0.5 or lower p.m./total fall ratio. This shift in the time of fall statistics suggests a strongly evolved orbit for the H5 parent at the time of collision about 7 Ma ago.

Marti, K.↗

Insights into Long-Term Global Precipitation from IMERG and GPCP

Multiple satellite-based datasets provide estimates of the long-term record of global precipitation. Each necessarily includes both the real atmospheric behavior and a collection of artifacts driven by the input data sources and design choices in the retrievals and dataset construction. For this presentation, the Integrated Multi-satellitE Retrievals for GPM (IMERG) products from the Global Precipitation Measurement (GPM) mission’s U.S. Science Team are designed as a modern High-Resolution Precipitation Product (HRPP), while the Global Precipitation Climatology Project’s (GPCP) products are designed as a modern Climate Data Record (CDR). Although they share some common input data sources, the computational process for each is rather different. Comparing the precipitation estimates from each algorithm gives us insights into likely artifacts and the natural variations that are common to both. The goal of an HRPP is to give the best estimate of precipitation at each time step in the dataset, generally meaning that “all possible available” data are used. In contrast, the CDR is intended to provide a precipitation record that has relatively homogeneous statistics, necessary for climate analysis. Each analysis strives for both goals, of course, but this means that the HRPP uses the disparate collection of satellites whose statistics don’t quite match the ideal record, while the CDR is computed from fewer satellites that provide a relatively homogeneous set of precipitation statistics. This presentation employs the current versions of the IMERG and GPCP products, V07B and V3.2, respectively. A variety of analyses have demonstrated that IMERG has more artifacts, as expected, which tend to result from changes in the source of intercalibration for the various input satellites, namely the Combined Radar-Radiometer Algorithm using TMI and PR during the TRMM era and using GMI and DPR-Ku during the GPM era. As well, a shift occurs when the altitudes of the TRMM and GPM satellites change as a result of orbit boosts. For the most part the mean precipitation shows good continuity across these boundaries, but there are noticeable changes in the respective histograms. The latter has taken on more importance in recent years due to increased scrutiny on extremes which implicitly focus on the upper end of the precipitation histograms. The GPCP product is more homogeneous, with only one major change in calibrator, transitioning from the SSMI series of satellites to the SSMIS series of satellites in 2009. The GPCP analysis does a good job of minimizing artifacts in the means at this boundary, while the histograms show a smaller, but still noticeable shift in the histograms, a result that is similar to data boundaries in IMERG. The GPCP Daily, which is a month-by-month rescaling of the daily accumulated IMERG Final product, shows more consistency than the equivalent daily IMERG, but inherits the histogram shifts from IMERG. Given this overlay of artifacts, there is enough consistency between the products to illustrate some important long-term variations, including interannual variations, not all of which are easily attributable to ENSO events, and trends that are large regionally, but comparatively small when averaged across the globe.

precipitation↗

Validation of the TOPAS Monte Carlo toolkit for HDR brachytherapy simulations

The goal of this work is to validate the user-friendly Geant4-based Monte Carlo toolkit TOol for PArticle Simulation (TOPAS) for brachytherapy applications. Brachytherapy simulations performed with TOPAS were systematically compared with published TG-186 reference data. The photon emission energy spectrum, the air-kerma strength, and the dose-rate constant of the model-based dose calculation algorithm (MBDCA)-WG generic Ir-192 source were extracted. For dose calculations, a track-length estimator was implemented. Additionally, the four Joint AAPM/ESTRO/ABG MBDCA-WG test cases were evaluated through histograms of the local and global dose difference volumes. A prostate, a palliative lung, and a breast case were simulated. For each case, the dose ratio map, the histogram of the global dose difference volume, and cumulative dose-volume histograms were calculated. The air-kerma strength was (9.772 ± 0.001) × 10 -8 U Bq -1 (within 0.3% of the reference value). The dose-rate constant was 1.1107 ± 0.0005 cGy h -1 U -1 (within 0.01% of the reference value). For all cases, at least 96.9% of voxels had a local dose difference within [-1%, 1%] and at least 99.9% of voxels had a global dose difference within [-0.1%, 0.1%]. The implemented track-length estimator scorer was more efficient than the default analog dose scorer by a factor of 237. For all clinical cases, at least 97.5% of voxels had a global dose difference within [-1%, 1%]. Dose-volume histograms were consistent with the reference data. TOPAS was validated for high-dose-rate brachytherapy simulations following the TG-186 recommended approach for MBDCAs. Built on top of Geant4, TOPAS provides broad access to a state-of-the-art Monte Carlo code for brachytherapy simulations.

59 BASIC BIOLOGICAL SCIENCES↗