Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hourly Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Optimized Renewable Energy Integration for EV High-Power Dynamic Wireless Charging Systems

Dynamic wireless charging for electric vehicles is an emerging technology to reduce on-board battery size and extend driving range. Due to its unique characteristic of vehicle-speed-related pulse-like load profile, the high-power dynamic wireless charging system (DWCS) introduces high stress to the utility grid. In this paper, an optimization model for renewable energy integration in the DWCS is proposed to mitigate the grid impact and minimize the operation costs of the whole system. As the load profile of DWCS is related to the traffic volume and various approaching vehicle speeds, the annual average daily traffic data and a stochastic model are used to develop 24-hour load profile of DWCS. To find a tradeoff between grid impact mitigation and operation costs minimization, relationships among power demand from power grid, photovoltaic (PV) capacity, wind energy (WE) capacity and energy storage (ES) capacity are analyzed, and the optimization objective and constraints are developed. Numerical simulation results demonstrate that energy storage integration can greatly mitigate the grid impact of DWCS, and optimal ratio of PV and WE can significantly reduce the operation cost of DWCS.

Zeng, Rong↗

Time-Sensitive Value of Efficiency: Use Cases in Electricity Sector Planning and Programs

Most energy efficiency measures produce energy savings that vary over the course of a year. The value of the hourly electricity savings also varies over the course of a year because the cost of generating, transmitting and distributing electricity during peak demand periods may be significantly higher than during off-peak, or lower load, hours. But many planning and program activities across the United States are missing this important element. A variety of trends are changing the electricity system, including increased adoption of other distributed energy resources, electrification of buildings and vehicles, and relative costs for natural gas-fired and renewable energy generation. Knowing when energy efficiency occurs and the value of the energy or demand savings to the electricity system—the time-sensitive value of efficiency—provides public utility commissions, utilities and other decision makers with key information needed to procure the optimal amount of energy efficiency for their system. The report begins with a discussion of our approach to determining use cases and examples, and then examines the need for time-sensitive efficiency data. Next, it examines five use cases in which states, independent system operators/regional transmission operators (ISOs/RTOs), utilities, and efficiency program administrators consider the TSV-EE: (1) energy efficiency program planning and evaluation, (2) distribution system planning, (3) electricity resource planning (4) electricity rate design, and (5) state and local government activities. The report concludes with areas for future research on the time-sensitive value of efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Generating realistic building electrical load profiles through the Generative Adversarial Network (GAN)

Building electrical load profiles can improve understanding of building energy efficiency, demand flexibility, and building-grid interactions. Current approaches to generating load profiles are time-consuming and not capable of reflecting the dynamic and stochastic behaviors of real buildings; some approaches also trigger data privacy concerns. In this study, we proposed a novel approach for generating realistic electrical load profiles of buildings through the Generative Adversarial Network (GAN), a machine learning technique that is capable of revealing an unknown probability distribution purely from data. The proposed approach has three main steps: (1) normalizing the daily 24-hour load profiles, (2) clustering the daily load profiles with the k-means algorithm, and (3) using GAN to generate daily load profiles for each cluster. The approach was tested with an open-source database – the Building Data Genome Project. We validated the proposed method by comparing the mean, standard deviation, and distribution of key parameters of the generated load profiles with those of the real ones. The KL divergence of the generated and real load profiles are within 0.3 for majority of parameters and clusters. Additionally, results showed the load profiles generated by GAN can capture not only the general trend but also the random variations of the actual electrical loads in buildings. We report the proposed GAN approach can be used to generate building electrical load profiles, verify other load profile generation models, detect changes to load profiles, and more importantly, anonymize smart meter data for sharing, to support research and applications of grid-interactive efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Creation of Synthetic Electric Grids (SPP/MISO) Supporting PERFORM (Final Report)

Over the course of the project, two “realistic but not real” synthetic transmission-level grid models over the SPP-MISO and ERCOT footprints were created to provide more realistic data and increase the reliability and resiliency of the grids under a variety of scenarios. The synthetic ERCOT transmission grid is compatible with the distribution grid developed in collaboration with NREL. All generators are based on the EIA 860 data and a column with EIA plant code and Gen ID is added to generators of both grids so that they can be easily mapped. The improvements are also made to electric grids including N-1 contingencies with some remedial actions, improving the transmission lines to avoid lines in lakes, including an HVDC line to the SPP-MISO case, providing several generator parameters and their temporal constraints that were not included in EIA 860 form, generators’ cost curves, load offer curves, adding phase shifters and tap changers with impedance correction tables, adding reactive power control and partitioning the grids into active and reactive reserve zones and determine different types of the required reserve for each zone. Hourly load time series at the bus level were generated to create scenarios for solving power flow in different loading conditions. Weather measurement information and the models of renewable generators are used to directly include the impact of weather on the grids. Based on a variety of load and weather conditions the grids are improved to accommodate different conditions. The ERCOT 7k-bus grids were also modeled for the year 2030 with predicted improvements in renewable resources. The renewable generation model was also improved with historic weather data included. The impact of electric vehicles on the ERCOT grid is also modeled.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Value Analysis of Geothermal Systems for End-Use Applications

Fuel based end-uses for residential, commercial, and industrial consumers require a technology change to achieve economy-wide decarbonization. Space heating accounts for 42% of residential and 32% of commercial energy demand, much of which is currently met through carbon emitting fuels. Industrial energy use is heavily fuel based with electricity currently representing 13% of energy demand. Geothermal heat pumps (GHPs) and geothermal direct use can eliminate the need for CO2 emitting and simultaneously allow for more efficient electrification of end uses. Past work has assessed the impact on total energy costs and generation investments but did not identify specific grid services benefited. Energy usage in residential and commercial structures was assessed by leveraging data from ComStock and ResStock models. These models utilize housing attributes, occupancy patterns, weather data, and sophisticated energy simulations to generate hourly load profiles for individual buildings identified by unique IDs associated with their locations. Industrial sector energy use was evaluated using information from the Manufacturing Energy Consumption Survey (MECS) as well as plant utilization data from the US Census to estimate hourly plant operations. The change in end-use demand for electricity, natural gas, and other fuels was calculated for different technologies that could meet this need. Using the ReEDS capacity expansion model, we produce regional price profiles that capture the grid benefit associated with the amount and timing of energy shifts in the power system from the adoption of geothermal systems relative to other technologies that could meet space heating, space cooling, and process heat requirements. We find that geothermal systems for meeting end-use demand add value to the energy system. In buildings where geothermal systems increase grid costs, these values are offset by reduced fuel costs and benefits to externalities, including emissions and health impacts.

decarbonization↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE↗

Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.

Grid-connected heat pump water heaters (HPWH) can shift electrical load while minimizing impacts to hot water availability for occupants. This capability provides a flexible grid resource to utilities seeking to manage peak loads Such load control also can feasibly improve renewable utilization within the utility electric production mix, for instance using off-peak generation during periods with high renewable energy generation. It also offers lower electric bills to customers through increased energy efficiency of HPWH and cuts greenhouse gas emissions. In particular, the Southeast U.S. due to its high penetration of electric water heating presents a promising opportunity for grid-connected HPWHs. This paper builds upon the results of an extensive HPWH load shifting field study conducted in 51 occupied homes in Florida using EcoPort technology (Butzbaugh et al, 2022). In 2022, only an initial evaluation was available. Here, long term load results are available as well as examination of various control strategies and influences. Analysis is conducted for HPWH energy use and load shifting performance based on home occupancy (i.e., low and high) and water heater location (i.e., conditioned and unconditioned) across different temperature profiles. An unexpected outcome of this analysis was the poor performance of HPWHs located in conditioned spaces, possibly because of inadequate air volume from improper installation. We did find higher demand reductions from 2-hour load ups and slightly improved for critical peak signals in the afternoon control periods. As expected, higher occupancy households showed great load reductions.

Fenaughty, Karen↗

Effects of Temporal Wind Patterns on the Value of Wind-Generated Electricity in California and the Northwest

Wind power production is variable, but also has diurnal and seasonal patterns. These patterns differ between sites, potentially making electric power from some wind sites more valuable for meeting customer loads or selling in wholesale power markets. This paper investigates whether the timing of wind significantly affects the value of electricity from sites in California and the Northwestern United States. We use both measured and modeled wind data and estimate the time-varying value of wind power with both financial and load-based metrics. We find that the potential difference in wholesale market value between better-correlated and poorly correlated wind sites is modest, on the order of 5-10 percent. A load-based metric, power production during the top 10 percent of peak load hours, varies more strongly between sites, suggesting that the capacity value of different wind projects could vary by as much as 50 percent based on the timing of wind alone.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Value Proposition for Cost-Effective, Demand Responsive-Enabling, Nonresidential Lighting System Retrofits in California Buildings

Commercial lighting represents a significant potential source of demand response (DR) for the electrical grid, via traditional load shedding and rapid-dispatch (fast-DR) ancillary services when DR is enabled by networked lighting controls (NLCs). However, despite the significant opportunity and a regulatory push, DR-enabled lighting is installed in relatively few buildings because most building owners do not recognize its strong value proposition. Although NLCs can reduce energy bills, optimize facilities, and increase revenue, these co-benefits are not well quantified. This project analyzed lighting DR resources and energy-related co-benefits for commercial buildings in California. Using more than 100,000 individual hourly load profiles, the team forecasted the potential DR resources likely available from commercial lighting in 2025 and estimated revenues available from participation of these DR resources in energy markets. Combining these results with field-study estimates for NLC installation costs and energy savings provided a detailed accounting of site-level cost and energy-related co-benefits by building type from NLC’s DR enablement. In many cases, energy savings alone can deliver significant net value, justifying NLC DR-enabled adoption. Additionally, the study considers the sometimes-larger non-energy benefits (NEBs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data analytics and optimization of an ice-based energy storage system for commercial buildings

Ice-based thermal energy storage (TES) systems can shift peak cooling demand and reduce operational energy costs (with time-of-use rates) in commercial buildings. The accurate prediction of the cooling load, and the optimal control strategy for managing the charging and discharging of a TES system, are two critical elements to improving system performance and achieving energy cost savings. This study utilizes data-driven analytics and modeling to holistically understand the operation of an ice–based TES system in a shopping mall, calculating the system’s performance using actual measured data from installed meters and sensors. Results show that there is significant savings potential when the current operating strategy is improved by appropriately scheduling the operation of each piece of equipment of the TES system, as well as by determining the amount of charging and discharging for each day. A novel optimal control strategy, determined by an optimization algorithm of Sequential Quadratic Programming, was developed to minimize the TES system’s operating costs. Three heuristic strategies were also investigated for comparison with our proposed strategy, and the results demonstrate the superiority of our method to the heuristic strategies in terms of total energy cost savings. Specifically, the optimal strategy yields energy costs of up to 11.3% per day and 9.3% per month compared with current operational strategies. A one-day-ahead hourly load prediction was also developed using machine learning algorithms, which facilitates the adoption of the developed data analytics and optimization of the control strategy in a real TES system operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A multi-scale calibration approach for process-oriented aggregated building energy demand models

Long-term energy planning relies largely on projections of future energy demand and hourly load profiles. Aggregate building models are increasingly being utilized to characterize the sensitivity of current and future building stocks to changes in climate, population, and building technology on city-to-regional-to-national scales. Due to challenges in the availability of data, those analyses have been limited to projection of energy demand at a single scale, usually state or country, while long-term planning power system models and production cost models might operate at different spatial scales such as energy regions which are focused on ensuring adequate generation infrastructure. In this work, we propose and evaluate a novel method to calibrate an aggregate building energy demand model (PNNL’s BEND model) against the best available data at the spatial scale of balancing authorities. This approach extends previous work on aggregated building energy demand by facilitating analysis of building energy demand across scales, in particular policy and operational decision-making scales. We show that the bias-corrected model estimates building electric loads reasonably well compared with estimates from a statistical model, but has the additional feature of flexibility across spatial scales. While the calibration approach is presently U.S.-centric and associated with U.S. energy regions, it can be extrapolated to other worldwide regions with similar scale challenges between policy and operational implementation decision making. We discuss the significant challenges involved in formulating and calibrating a complex physical model based on simulations of roughly 100,000 individual buildings against available aggregate regional electric load data and highlight areas for potential future work and improved data collection.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Renewable-battery hybrid power plants in congested electricity markets: Implications for plant configuration

Examining coupled renewable-battery power plants (“hybrids”) in congested areas provides insights into a future of increased wind and solar penetration. Our study focuses on two types of congested regions, Variable Renewable Energy (VRE)-rich Areas and Load Centers, and explores likely plant configuration choices for developers and transmission network planners. Here, this paper examines how hybrid value, comprising energy and capacity value, varies by plant configuration and congested region type considering factors such as storage duration, battery degradation, and ability to charge from the grid. We select plant locations from across the seven main U.S. independent system operators (ISOs). Hybrid value for each configuration is computed based on profit-maximizing plant operation given perfect foresight, according to observed wholesale power market real time prices from 2018 to 2021. In VRE-rich Areas, the median increase in energy value from extending storage duration from one to 4h is 29.4% for solar and 26.8% for wind, assuming low battery degradation costs and storage sized to 100% of the plant's nameplate generation capacity. Increasing storage duration beyond 4h does not substantially increase its value from energy markets, even in VRE-rich Areas. We find that solar hybrids reach a 90% capacity credit with 4h of storage, while wind hybrids require 8h of storage, based on the capacity factor of each hybrid during the top 100 net load hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The value of demand response in Florida

Many electrical loads may be operated flexibly to provide grid services, including peaking capacity, reserves, and load shifting. The authors model 14 demand end uses in Florida and analyze their operational impacts and overall value for a wide range of solar penetrations and grid flexibility options. They find demand response is able to reduce production costs, reduce the number of low-load hours for traditional generators, reduce starting of gas generators, and reduce curtailment.

14 SOLAR ENERGY↗

Joint Management and Optimization of Residential Natural Gas and Electricity Distribution Networks Coupled via Fuel Cells

The attractive features of natural gas as well as the growing electric power demand worldwide have created increasing interest in natural-gas-based distributed generation applications for electric distribution networks. Here, this paper investigates the interdependency between a residential natural gas network and an electric distribution network that are linked together via fuel cells. The modeling of the natural gas network is introduced first, and then the algorithm for gas flow study is presented. The optimal placement and sizing of fuel cell based distributed generation systems are formulated to minimize the losses in both the natural gas network and the electric distribution grid, subject to the constraints imposed by both networks. In addition, a probabilistic model for both gas and electricity demands is developed based on historical electricity and natural gas demand data. A K-means clustering method is used to determine the hourly load states to solve the joint probabilistic optimization problem. Simulation studies are carried out on an integrated system consisting of the IEEE 69-bus distribution network and a radial 27-node natural gas network to verify the developed optimization model and the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Reliability Assessment for Marine Renewable Energy Enabled Island Power Systems

Marine renewable energy (MRE) resources are highly predictable and persistent sources of energy, when compared to other renewable sources like wind and solar. These lend them favorably for potential grid applications, particularly for coastal/island power systems where their generation potential is high. Island power systems, on the other hand, are either supported by onsite generation or by transported energy from the mainland grid. Therefore, robustness of grid operations depend heavily on the diversity of onsite generation resources and the reliability of the power transportation medium. Issues relating to either of these two factors may lead to impediments in smooth and reliable operation of the power system. Analyzing and quantifying operational risks for such island power systems with diverse non-conventional generation portfolios through conventional techniques can also prove to be cumbersome, often requiring multiple different inputs. Therefore, in this paper, we firstly present a novel, purely data-driven formulation which quantifies the operational reliability of such island power systems through minimal input data. Specifically, our proposed methodology only relies on historical knowledge of typical hourly load and generation profiles to quantify associated operational risks. Subsequently, we use our proposed formulation to evaluate the effectiveness of MRE resources (over other renewable resources like wind and solar) in providing resilience benefits to island power systems. The proposed formulation is demonstrated with a case study for an island power system in Nantucket, MA.

Chalishazar, Vishvas H.↗

Joint Management and Optimization of Residential Natural Gas and Electricity Distribution Networks Coupled via Fuel Cells

The interesting properties of natural gas as well as the growing electric power demand worldwide have led to increasing attention to natural-gas-based distributed generation applications in electric distribution systems. This paper goes over the interdependency between a residential natural gas network and an electric distribution network that are coupled via fuel cells. The modeling of the gas network is introduced first, and then the algorithm for gas flow study is presented. The optimal placement and sizing of fuel cell based distributed generation systems are formulated to minimize the losses in both the gas and electric distribution networks, subject to their model constraints. In addition to this, in order to capture the probabilistic nature of the optimization problem under study, the K-means clustering algorithm is applied to the gas and electricity demands to determine hourly load states and their corresponding probabilities. Furthermore, simulation studies are carried out on an integrated system consisting of the IEEE 69-bus distribution feeder and a radial 27-node natural gas network to verify the developed optimization model and the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Disaggregating Customer-Level Behind-the-Meter PV Generation Using Smart Meter Data and Solar Exemplars

Customer-level rooftop photovoltaic (PV) has been widely integrated into distribution systems. In most cases, PVs are installed behind-the-meter (BTM), and only the net demand is recorded. Therefore, the native demand and PV generation are unknown to utilities. Separating native demand and solar generation from net demand is critical for improving grid-edge observability. In this paper, a novel approach is proposed for disaggregating customer-level BTM PV generation using low-resolution but widely available hourly smart meter data. The proposed approach exploits the strong correlation between monthly nocturnal and diurnal native demands and the high similarity among PV generation profiles. First, a joint probability density function (PDF) of monthly nocturnal and diurnal native demands is constructed for customers without PVs, using Gaussian mixture modeling (GMM). Deviation from the constructed PDF is utilized to probabilistically assess the monthly solar generation of customers with PVs. Then, to identify hourly BTM solar generation for these customers, their estimated monthly solar generation is decomposed into an hourly timescale; to do this, we have proposed a maximum likelihood estimation (MLE)-based technique that utilizes hourly typical solar exemplars. Leveraging the strong monthly native demand correlation and high PV generation similarity enhances our approach's robustness against the volatility of customers’ hourly load and enables highly-accurate disaggregation. Furthermore, the proposed approach has been verified using real native demand and PV generation data.

14 SOLAR ENERGY↗

Electric Grid Simulator For Human Factor Research

The developed code simulates real-time monitor and control for west area of IEEE 118-bus system. The 24-hour load profile for each bus is derived by scaling the system’s rated load in the PSSE sav file according to the California Independent System Operator’s Day-ahead load forecast for May 1, 2024. This simulator performs several critical functions: (1) Calculating time-series power flow every 4 seconds; (2) Updating and dispatching AGC signals every minute; (3) Conducting N-1 contingency analysis every 5 minutes. Additionally, the simulator can trip lines and subsequently update and dispatch AGC signals, running power flow analysis after each tripping event.

Huang, Jianqiao [Idaho National Laboratory (INL), ↗