Search NASA⌕ Search

SEARCH · Search NASA

Results for “Humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Humidity sensitivity of large area silicon sensors: Study and implications

The production of large area sensors is one of the main challenges that the ATLAS collaboration faces for the new Inner-Tracker full-silicon detector. During the prototype fabrication phase for the High Luminosity Large Hadron Collider upgrade, several ATLAS institutes observed indications of humidity sensitivity of large area sensors, even at relative humidities well below the dew point. Specifically, prototype Barrel and End-Cap silicon strip sensors fabricated in 6-inch wafers manifest a prompt decrease of the breakdown voltage when operating under high relative humidity, adversely affecting the performance of the sensors. In addition to the investigation of these prototype sensors, a specific fabrication batch with special passivation is also studied, allowing for a deeper understanding of the responsible mechanisms. Here we present an extensive study of this behaviour on large area sensors. The locations of the hotspots at the breakdown voltage at high humidity are revealed using different infrared thermography techniques. Several palliative treatments are attempted, proving the influence of sensor cleaning methods, as well as baking, on the device performance, but no improvement on the humidity sensitivity was achieved. Furthermore, a study of the incidence of the sensitivity in different batches is also presented, introducing a hypothesis of the origins of the humidity sensitivity associated to the sensor edge design, together with passivation thickness and conformity. Several actions to be taken during sensor production and assembly are extracted from this study, in order to minimize the impact of humidity sensitivity on the performance of large area silicon sensors for High Energy Physics experiments.

47 OTHER INSTRUMENTATION↗

Acute airway effects of airborne formaldehyde in sensitized and non-sensitized mice housed in a dry or humid environment

We investigated the role of air humidity and allergic sensitization on the acute airway response to inhaled formaldehyde (FA) vapor. Mice were sensitized to the immunogen ovalbumin (OVA) by three intraperitoneal injections followed by two aerosol challenges, giving rise to allergic airway inflammation. Control mice were sham sensitized by saline injections and challenged by saline aerosols. Once sensitized, the mice were housed at high (85–89%) or low (< 10%) relative humidity, respectively for 48 h prior to a 60-min exposure to either 0.4, 1.8 or about 5 ppm FA. Before, during and after exposure, breathing parameters were monitored. These included the specific markers of nose and lung irritations as well as the expiratory flow rate, the latter being a marker of airflow limitation. The sensory irritation response in the upper airways was not affected by allergic inflammation or changes in humidity. At high relative humidity, the OVA-sensitized mice had a decreased expiratory airflow rate compared to the saline control mice after exposure to approximately 5 ppm FA. This is in accordance with the observations that asthmatics are more sensitive than non-asthmatics to higher concentrations of airway irritants including FA. In the dry environment, the opposite trend was seen; here, the saline control mice had a significantly decreased expiratory airflow rate compared to OVA-sensitized mice when exposed to 1.8 and 4 ppm FA. We speculate that increased mucus production in the OVA-sensitized mice has increased the “scrubber effect” in the nose, consequently protecting the conducting and lower airways. - Highlights: ► Role of air humidity and allergy on sensitivity to an airway irritant was studied. ► In the humid environment, allergy amplified the effects of formaldehyde. ► In the dry environment, allergy reduced the effect of formaldehyde. ► Neither allergy nor humidity changed the formaldehyde-induced nasal irritation.

60 APPLIED LIFE SCIENCES↗

An Impedance Humidity Sensor Based on CVD Grown WSe 2 2D Films

2D materials-based planar devices have been sought after for gas and humidity sensor applications owing to their high sensitivity due to their ultrathin nature and increased surface area. Herein, 2D WSe 2 films-based planner devices were fabricated to evaluate their performance for potential application in humidity sensors. The structure and morphology of the WSe 2 sensing films were studied by Raman spectroscopy, photoluminescence, optical microscopy, and scanning electron microscopy (SEM) techniques. The relative humidity-dependent sensing performances of the 2D WSe 2 films were evaluated using current–voltage (I–V), relative impedance, and complex total impedance (electrochemical impedance spectroscopy, EIS) techniques. This sensor showed a very stable and repeatable performance investigated over the period of 18 months. The response and recovery times of the WSe 2 -based impedance sensors were found to be 40 and 30 s, respectively. The WSe 2 sensor exhibits a 2 ± 1% minimum hysteresis at a lower humidity level (50% RH) and around 8 ± 2% maximum hysteresis at relative humidity level (70% RH). This value of hysteresis is in the acceptable range during the initial investigation of any material to explore its potential for application in humidity sensors. The density functional theory (DFT) analysis was performed with the interaction from water molecules of the WSe 2 sample for a better understanding of the sensing mechanism of devices.

2D- WSe2↗

Technology Solutions Case Study: Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate, New Orleans, Louisiana

The purpose of this project by Building Science Corporation was to evaluate the humidity control performance of new single family high performance homes, and compare the interior conditions and mechanical systems operation between two distinct groups of houses: homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were 10 single-family new construction homes in New Orleans, LA. Data logging equipment was installed at each home in 2012, and interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space; however, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.

BSC↗

How does humidity data impact land surface modeling of hydrothermal regimes at a permafrost site in Utqia$\mathrm{\dot{g}}$vik, Alaska?

Humidity is a basic and crucial meteorological indicator commonly measured in several forms, including specific humidity, relative humidity, and absolute humidity. These different forms can be inter-derived based on the saturation vapor pressure (SVP). In past decades, dozens of formulae have been developed to calculate the SVP with respect to, and in equilibrium with, liquid water and solid ice surfaces, but many prior studies use a single function for all temperature ranges, without considering the distinction between over the liquid water and ice surfaces. These different approaches can result in humidity estimates that may impact our understanding of surface-subsurface thermal-hydrological dynamics in cold regions. In this study, we compared the relative humidity (RH) downloaded and calculated from four data sources in Alaska based on five commonly used SVP formulas. These RHs, along with other meteorological indicators, were then used to drive physics-rich land surface models at a permafrost-affected site. Here, we found that higher values of RH (up to 40%) were obtained if the SVP was calculated with the over-ice formulation when air temperatures were below freezing, which could lead to a 30% maximum difference in snow depths. The choice of whether to separately calculate the SVP over an ice surface in winter also produced a significant range (up to 0.2 m) in simulated annual maximum thaw depths. The sensitivity of seasonal thaw depth to the formulation of SVP increases with the rainfall rate and the height of above-ground ponded water, while it diminishes with warmer air temperatures. These results show that RH variations based on the calculation of SVP with or without over-ice calculation meaningfully impact physically-based predictions of snow depth, sublimation, soil temperature, and active layer thickness. Under particular conditions, when severe flooding (inundation) and cool air temperatures are present, care should be taken to evaluate how humidity data is estimated for land surface and earth system modeling.

54 ENVIRONMENTAL SCIENCES↗

Frictional properties of Opalinus Clay: influence of humidity, normal stress and grain size on frictional stability

SUMMARY The Opalinus Clay (OPA) is a clay-rich formation considered as a potential host rock for radioactive waste repositories and as a caprock for carbon storage in Switzerland. Its very low permeability (10−19 to 10−21 m2) makes it a potential sealing horizon, however the presence of faults that may be activated during the lifetime of a repository project can compromise the long-term hydrological confinement, and lead to mechanical instability. Here, we have performed laboratory experiments to test the effect of relative humidity (RH), grain size (g.s.) and normal stress on rate-and-state frictional properties and stability of fault laboratory analogues corresponding to powders of OPA shaly facies. The sifted host rock powders at different grain size fractions (<63 μm and 63 < g.s. < 125 μm), at room (∼25 per cent) and 100 per cent humidity, were slid in double-direct shear configuration, under different normal stresses (5–70 MPa). We observe that peak friction, μpeak and steady-state friction, μss, depend on water vapour content and applied normal stress. Increasing relative humidity from ∼25 per cent RH (room humidity) to 100 per cent RH causes a decrease of frictional coefficient from 0.41 to 0.35. The analysis of velocity-steps in the light of rate-and-state friction framework shows that the stability parameter (a–b) is always positive (velocity-strengthening), and it increases with increasing sliding velocity and humidity. The dependence of (a–b) on slip rate is lost as normal stress increases, for each humidity condition. By monitoring the variations of the layer thickness during the velocity steps, we observe that dilation (Δh) is directly proportional to the sliding velocity, decreases with normal stress and is unaffected by humidity. Microstructural analysis shows that most of the deformation is accommodated within B-shear zones, and the increase of normal stress (σn) promotes the transition from strain localization and grain size reduction to distributed deformation on a well-developed phyllosilicate network. These results suggest that: (1) the progressive loss of velocity dependence of frictional stability parameter (a–b) at σn > 35 MPa is dictated by a transition from localized to distributed deformation and (2) water vapour content does not affect the deformation mechanisms and dilation, whereas it decreases steady-state friction (μss), and enhances fault stability.

58 GEOSCIENCES↗

Fabrication of bulk alumina structures with humidity sensing capabilities using direct ink write technique

Purpose The purpose of this study is to evaluate different 3D structures for humidity sensing that will enable the fabrication of complex geometries with high moisture sensitivity. Design/methodology/approach Humidity sensors based on alumina ceramics were fabricated using direct ink write (DIW) technique. Different engineered surface area, polymer binder ratio and post-processing treatment were considered to increase moisture sensitivity. Findings It was found that the binder ratio plays an important role in controlling the rheology of the paste during printing and determining the pore size after post-processing treatment. The sensibility of the fabricated humidity sensor was investigated by measuring its capacitance response toward relative humidity (RH) varying from 40% to 90% RH at 25°C. It is shown that using 3D lattice design, printed alumina humidity sensor could improve sensitivity up to 31.6 pF/RH%, over an order of magnitude higher than solid alumina. Originality/value Most of the alumina humidity sensors available are films in nature because of manufacturing difficulties, which limited its potential of higher sensitivity, and thus broader applications. In this paper, a novel 3D alumina humidity sensor was fabricated using DIW 3D printing technology.

Engineering↗

Capture of Uranium Particles By Filtration: Effects of Filter Material and Air Humidity

Filtration of airborne particles is a standard technique for removal of radiological particles from the effluent of a nuclear reactor. The effects of humidity on filter performance and uranium particles are however less understood. We have conducted experimental runs in the Environmental Experimental Chamber (EEC) located at ORNL to study the capture of uranyl fluoride particles in supports of NNSA missions. Two filter types, one of Minimum Efficiency Reporting Value (MERV)-9 and the other of MERV-10 American Society of Heating, Refrigerating and Air-Conditioning Engineering) ASHRAE rating, were used in the investigations under two humidity conditions [15% and 65% Relative Humidity (Rh)]. Both MERV9 and MERV10 filters failed to capture uranyl fluoride particles that were smaller than 100 nm. The penetration efficiencies for both filter types were very high, greater than 80%, for particles from 10 to 100 nm. As particles became larger and wetter, the capturing efficiencies of both types of filter improved. Slightly greater than 50% of particles from 1 to 10 μm still escaped the capture by the MERV9 filters. However, MERV10 filters were able to capture higher than 50% of particles in the size range of 1 to 2 μm indicating it is likely to meet ASHRAE requirements. Overall, the capture efficiency of a filter is highly dependent on uranyl fluoride particle size, which humidity plays a major role. These two filter types simply are unable to capture particles smaller than 1 μm. A filter that has a higher ASHRAE rating like the HEPA filter has to be used to capture sub-micron particles. Questions on how uranyl fluoride behave in a condition higher than 65% Rh remain, because the particles could deliquescent at the higher humidity condition. That would complete change the size, shape, and surface properties of the uranyl fluoride particles which could lead to completely different filter performance and filtration dynamics. Furthermore, how high humidity affects filters of all MERV ratings remain unclear. Other filter characteristics such as surface charge could also be affected by high humidity condition and need to be investigated.

42 ENGINEERING↗

Humidity scanning quartz crystal microbalance with dissipation monitoring setup for determination of sorption-desorption isotherms and rheological changes

A new method to determine water sorption-desorption isotherms with high resolution in the complete range of water activities (relative humidities) is presented. The method is based on quartz crystal microbalance with dissipation monitoring (QCM-D). The QCM-D is equipped with a humidity module in which the sample film is kept in air with controlled humidity. The experimental setup allows for continuous scanning of the relative humidity from either dry to humid conditions or vice versa. The amount of water sorbed or desorbed from the sample is determined from the resonance frequencies of the coated quartz sensor, via analysis of the overtone dependence. In addition, the method allows for characterization of hydration induced changes of the rheological properties from the dissipation data, which is closely connected to the viscoelasticity of the film. The accuracy of the humidity scanning setup is confirmed in control experiments. Sorption-desorption isotherms of pig gastric mucin and lysozyme, obtained by the new method, show good agreement with previous results. Finally, we show that the deposition technique used to coat the quartz sensor influences the QCM-D data and how this issue can be used to obtain further information on the effect of hydration. In particular, we demonstrate that spin-coating represents an attractive alternative to obtain sorption-desorption isotherms, while drop-coating provides additional information on changes of the rheological properties during hydration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of humidity on the characteristics of negative corona discharge in air

Detailed negative corona discharge characteristics, such as the pulse amplitude, repetition frequency, average corona current, rise time, and half-wave time, are systematically studied under various air humidities with a single artificial defect electrode. The experimental result reveals that the pulse amplitude increases with the increase of air humidity; meanwhile, the repetition frequency deceases as the air humidity increases. Empirical formulae are first established for the pulse amplitude and repetition frequency with the humidity factor taken into consideration. The effective ionization integral is calculated and a positive correlation is found between the integral and the pulse amplitude. Furthermore, a simplified negative-ion cloud model is built up to investigate the mechanism of the humidity's influence on negative corona discharge. Based on the theoretical analyses, the correlation between pulse amplitude, repetition frequency, and air humidity is well explained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Humidity data for 9975 shipping packages with cane fiberboard

The 9975 surveillance program is developing a technical basis to support extending the storage period of 9975 packages in K-Area Complex beyond the currently approved 15 years. A key element of this effort is developing a better understanding of degradation of the fiberboard assembly under storage conditions. This degradation is influenced greatly by the moisture content of the fiberboard, which is not well characterized on an individual package basis. Direct measurements of humidity and fiberboard moisture content have been made on two test packages with cane fiberboard and varying internal heat levels from 0 up to 19W. With an internal heat load, a temperature gradient in the fiberboard assembly leads to varying relative humidity in the air around the fiberboard. However, the absolute humidity tends to remain approximately constant throughout the package. The moisture content of fiberboard varies under the influence of several phenomena. Changes in local fiberboard temperature (from an internal heat load) can cause fiberboard moisture changes through absorption or evaporation. Fiberboard degradation at elevated temperature will produce water as a byproduct. And the moisture level within the package is constantly seeking equilibrium with that of the surrounding room air, which varies on a daily and seasonal basis. One indicator of the moisture condition within a 9975 package might be obtained by measuring the relative humidity in the upper air space, by inserting a humidity probe through a caplug hole. However, the data indicate that for the higher internal heat loads (15 and 19 watts), a large variation in internal moisture conditions produces little or no variation in the air space relative humidity. Therefore, this approach does not appear to be sensitive to fiberboard moisture variations at the higher heat loads which are of most interest to maintaining fiberboard integrity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Mission Profiles for Humidity Models in the Reliability Testing of PV Inverters: Preprint

To understand the impacts of humidity on PV inverters, mission profiles were developed to accurately describe the different processes and rates based on the environmental factors of temperature, relative humidity, and irradiance. The operating environment of the device introduces stress factors dependent on component temperature, relative humidity, and component voltage. The development of profiles started from looking at historical climate conditions at Cocoa, Florida, a hot and humid location. The profile developed from field location was compared with existing humidity test profiles in industrial and military standards to determine acceleration factors. Prior to the evaluation of the mission profiles, critical components in the PV inverter were identified based on vendor discussions along with failure modes of interest. The profiles considered in this study was demonstrated using a 4-kVA string inverter. The measurements from the devices were substituted in device manufacturer specified equation to determine the severity of each test. The severity of each test was compared against the severity of the 24-hour result to determine the acceleration factor of each test. The acceleration factors were determined to be over a range of 1.2-6 for the existing humidity tests from standards, when compared against the mission profile developed from field data. This optimal humidity/thermal profile will be passed to the IEC standards development for inverter qualification testing.

humidity models↗

The Effect of Environmental Relative Humidity on Carbonation and Oxidation in a Cementitious Waste Form - 18448

Cementitious material has been developed and used for the nuclear waste disposal. Cast Stone, a type of cementitious waste form, is considered for solidification and immobilization of part of low activity radioactive waste (LAW) at DOE Hanford Site in Richland, WA. During its life cycle, the waste form, which is produced from Portland cement, fly ash, blast furnace slag and liquid waste, is subject to reaction with carbon dioxide and oxygen, both in gaseous and dissolved form. The reactions may alter the physical and chemical properties of the waste form and thus change its retention ability for the radionuclides. Therefore, understanding the rate and the impact of oxidation and carbonation in the material is important for projecting the long-term performance of Cast Stone. However, the rate of carbonation and oxidation in Cast Stone closely depends on the moisture content in the material, which varies largely with the environmental relative humidity (RH). In this study, experiments are carried out to study the effect of environmental relative humidity on the carbonation and oxidation rate as well as the leaching of the constituents from Cast Stone. Cast Stone samples doped with Cr as a reaction indicator are aged for 16 to 32 weeks under N{sub 2}, air, and 2% CO{sub 2} (in nitrogen) environments with various relative humidities (15%, 40%, 68%, 100%). After aging, samples were tested for the pH-dependent leaching (EPA Method 1313) and mass transfer rate under diffusion-controlled leaching (EPA Method 1315) of constituents. The progress of the carbonation was measured for each condition to determine the rate of carbonation front ingress. The results show that environmental relative humidity strongly influences carbonation and oxidation in Cast Stone; however, the impact is different for the rate of reaction and for the extent of reactions. The former refers to the rate at which the reaction front ingresses, while the latter refers to the fraction of the material reacted. For both carbonation and oxidation, the largest impact of the reactions at the exposure surface is observed at intermediate relative humidity (68%). However, for carbonation, the reaction front evolves more rapidly under drier conditions, with the highest rate observed at 15% RH. As a result, carbonation and oxidation have different degree of impact on the leaching behavior of Cast Stone samples aged under various relative humidities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Water vapor exposure chamber for constant humidity and hydrogen and oxygen stable isotope composition

Rationale: Water vapor exposure experiments have applications for studying water physisorption and chemisorption hydration and hydroxylation reactions on a wide variety of material surfaces. The stable isotopes of hydrogen and oxygen in the water molecule are useful tracers of water exchange mechanisms and/or rates in such vapor exposure experiments. Methods: We designed and built a humidity chamber system that uses membrane-mediated liquid–vapor exchange of water followed by mixing with dry air to control the relative humidity of air and its δ 2 H and δ 18 O isotopic composition. We tested the stability and precision of the humidity and its isotopic composition on hourly to 90-day timescales. Results: The humidity chamber design reported here is capable of providing relative humidity control to within ±1%, and consistent δ 2 H and δ 18 O values of the water vapor that are similar to our cavity ringdown spectroscopy (CRDS) measurement precision (δ2H vap ± 0.7‰ and δ18O vap ± 0.24‰). We quantify the isotopic enrichment effects of Rayleigh distillation in the system and provide information on water reservoir sizes large enough to buffer isotopic enrichment effects to within measurement precision. Conclusions: The humidity chamber design reported here provides a means to create constant δ2H and δ18O values over the course of an exposure experiment. The design has applications to a wide range of studies of water sorption on material surfaces from foods and pharmaceuticals to geological materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anomalous water expulsion from carbon-based rods at high humidity

Managing water is critical for industrial applications including CO2 capture, catalysis, bio-oil separations and energy storage. Various classes of materials have been designed for these applications, achieving specific water adsorption capacities at a given relative humidity (RH). Three water adsorption-desorption mechanisms are common to inorganic materials: (1) chemisorption, which may lead to the modification of the first coordination sphere; (2) simple adsorption, which is reversible in nature; or (3) capillary condensation, which is irreversible in nature. Regardless of sorption mechanism, all materials known today increase water adsorption capacity with increasing RH; none exhibit repeated adsorption of water at low humidity and release at high humidity. We present here a material that breaks from this convention: a new class of nitrogen containing carbon rods along with nonstoichiometric FeXSY that adsorb water at low humidity, and spontaneously expel half of the adsorbed water when the RH exceeds a 50–80% threshold. Monolayers of water form on the surfaces of the carbon rods, with the amount of water adsorbed directly linked to the aspect ratio of the rods and the available surface area. This unprecedented water expulsion is a reversible physical process. Once a complete monolayer is formed, adjacent rods in the bundles begin to adhere together via formation of a bridging monolayer, reducing the surface area available for water to adhere to. We believe the unique surface chemistry of these carbon rods can be used on other functionalized materials. Such behaviour offers a paradigm shift in water purification and separation: water could be repeatedly adsorbed from a low humidity vapour stream and then expelled into a pure water vapour stream, or humidity-responsive membranes could change their water permeance or selectivity as a function of RH.

36 MATERIALS SCIENCE↗

Light rain exacerbates extreme humid heat

Abstract Humid heat waves pose significant risks to human health and the ecosystem. Intuitively, rainfall often alleviates extreme humid heat. However, here we show that light rain often accompanies extreme humid heat, exacerbating its frequency and intensity, especially over arid and semi-arid regions compared to no rain and moderate-to-heavy rain cases. This is because light rain does not dramatically reduce solar radiation but increases near-surface humidity through enhanced surface evaporation. The water replenishment from light rain as well as a shallower planetary boundary layer is crucial for consecutive extremes where there are commonly sporadic drizzle days amidst several rain-free days. These extremes last longer than rain-free extremes. Current global climate models (GCMs) overestimate light rain. After reducing this bias in a GCM, underestimations of humid heat waves in energy-limited regions and overestimations in water-limited regions are largely alleviated. These findings underscore the underappreciated impact of light rain on extreme humid heat.

Science & Technology - Other Topics↗

Reversible Humidity Sensitive Clothing for Personal Thermoregulation

Two kinds of humidity-induced, bendable smart clothing have been designed to reversibly adapt their thermal insulation functionality. The first design mimics the pores in human skin, in which pre-cut flaps open to produce pores in Nafion sheets when humidity increases, as might occur during human sweating thus permitting air flow and reducing both the humidity level and the apparent temperature. Like the smart human sweating pores, the flaps can close automatically after the perspiration to keep the wearer warm. The second design involves thickness adjustable clothes by inserting the bent polymer sheets between two fabrics. As the humidity increases, the sheets become thinner, thus reducing the gap between the two fabrics to reduce the thermal insulation. The insulation layer can recover its original thickness upon humidity reduction to restore its warmth-preservation function. Such humidity sensitive smart polymer materials can be utilized to adjust personal comfort, and be effective in reducing energy consumption for building heating or cooling with numerous smart design.

36 MATERIALS SCIENCE↗

Hydration of α-UO 3 following storage under controlled conditions of temperature and relative humidity

Changes in chemical speciation of uranium oxides following storage under varied conditions of temperature and relative humidity are valuable for characterizing material provenance. In this study, subsamples of high purity α-UO 3 were stored under four sets of controlled conditions of temperature and relative humidity over several years, and then measured periodically for chemical speciation. Powder X-ray diffraction (XRD) analysis and extended X-ray absorption fine structure spectroscopy confirm hydration of α-UO 3 to a schoepite-like end product following storage under each of the varied storage conditions, but the species formed during exposure to the lower relative humidity and lower temperature condition follows different trends from those formed under the other three storage conditions (high relative humidity with high or low temperatures, and low relative humidity with a high temperature). Thermogravimetry coupled with XRD analysis was carried out to distinguish desorption pathways of water from the hydrated end products. Density functional theory calculations discern changes in the structure of α-UO 3 following incorporation of 1, 2 or 3 H 2 O molecules or 1, 2 or 3 OH groups into the orthorhombic lattice, revealing differences in lattice constants, U–O bond lengths, and U–U distances. The collective results from this analysis are in contrast to analogous studies that report that U 3 O 8 is oxidized and hydrated in air during storage under high relative humidity conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗