Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hydrogen Concentrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

NIRS-Derived Tissue Oxygen Saturation and Hydrogen Ion Concentration Following Bed Rest

Long-term bed rest (BR), a model of spaceflight, results in a decrease in aerobic capacity and altered submaximal exercise responses. The strongest BR-induced effects on exercise appear to be centrally-mediated, but longer BR durations may result in peripheral adaptations (e.g., decreased mitochondrial and capillary density) which are likely to influence exercise responses. PURPOSE: To measure tissue oxygen saturation (SO2) and hydrogen ion concentration ([H+]) in the vastus lateralis (VL) using near infrared spectroscopy (NIRS) during cycle ergometry before and after . 30 d of BR. METHODS: Eight subjects performed a graded exercise test on a cycle ergometer to volitional fatigue 7 d before (pre-BR) and at the end or 1 day after BR (post-BR). NIRS spectra were collected from a sensor adhered to the skin overlying the VL. Oxygen consumption (VO2) was measured by open circuit spirometry. Blood volume (BV) was measured before and after BR using the carbon monoxide rebreathing technique. Changes in pre- and post-BR SO2 and [H+] data were compared using mixed model analyses. BV and peak exercise data were compared using paired t-tests. RESULTS: BV (pre-BR: 4.3+/-0.3, post-BR: 3.7+/-0.2 L, mean+/-SE, p=.01) and peak VO2 (pre-BR: 1.98+/-0.24, post-BR: 1.48 +/-0.21 L/min, p<.01) were reduced after BR. As expected, SO2 decreased with exercise before and after BR. However, SO2 was lower post compared with pre-BR throughout exercise, including at peak exercise (pre-BR: 50+/-3, post-BR: 43+/-4%, p=.01). After BR, [H+] was higher at the start of exercise and did not increase at the same rate as pre-BR. Peak [H+] was not different from pre to post-BR (pre-BR: 36+/-2; post-BR: 38+/-2 nmol/L). CONCLUSIONS: Lower SO2 during exercise suggests that oxygen extraction in the VL is higher after BR, perhaps due to lower circulating blood volume. The higher [H+] after BR suggests a greater reliance upon glycolysis during submaximal exercise, although [H+] at peak exercise was unchanged. Taken together, these data suggest that longer duration BR induces a number of changes that result in peripheral adaptations which contribute to cardiovascular and muscular deconditioning as measured by NIRS-derived SO2 and [H+] in the VL and may contribute to lower post-BR exercise tolerance. Supported by the National Space Biomedical Research Institute through NASA NCC 9-58

Lee, S. M. C.↗

Measurement of the stratospheric hydrogen peroxide concentration profile using far infrared thermal emission spectroscopy

The first unequivocal measurement of hydrogen peroxide in the stratosphere have been made, a concentration profile obtained from a balloon platform using Fourier transform thermal emission spectroscopy in the far infrared. Measurements were made using the 112/cm R-Q5 branch of the rotational-torsional spectrum, with some confirmation from the 94/cm R-Q4 branch. The volume mixing ratio of H2O2 is 1.6 x 10 to the -10th at 38.4 km, decreasing to 0.6 x 10 to the -10th at 23.8 km, with uncertainties of about 16 percent. These measurements are compared to a recent stratospheric model calculation.

Chance, K. V.↗

Effect of hydrogen on the mechanical properties of titanium and its alloys

Occluded hydrogen resulting from cathodic charging of commercially pure titanium and titanium alloys, Ti-8Al-1Mo-1V and Ti-6Al-4V, was shown to cause embrittlement of the alloys. Embrittlement was a function of the interstitial hydrogen content rather than the amount of precipitated titanium hydride. The effects of hydrogen concentration on the critical strain for plastic instability along pure shear directions was determined for alloys Ti-8Al-1Mo-1V and Ti-5Al-2.5Sn. Hydrogen, in concentrations below that necessary for spontaneous hydride precipitation, increased the strain necessary for instability formation or instability failure. The strain rate sensitivity also increased with increasing hydrogen concentration. The effect of hydrogen on slip and twinning was determined for titanium single crystals. The critical resolved shear stress for prism slip was increased and the critical resolved shear stress for twinning was decreased with increasing hydrogen concentration.

Beck, F. H.↗

Winter bulge and diurnal variations in hydrogen inferred from AE-C composition measurements

In situ mass spectrometric measurements of ion and neutral particle thermospheric compositions have been used to infer the latitudinal and diurnal variations of thermospheric atomic hydrogen for solstice conditions. Local time-dependent and local time-independent components of the observed hydrogen distribution were separated on the basis of a model generated by expanding the log of neutral hydrogen concentration in terms of spherical harmonics. Results are compared with analogous data on N2 concentration; the comparison reveals an anticorrelation between gas temperature and hydrogen concentration. The slope of this anticorrelation line represents the 'zero flux condition' from the exosphere theory of Hodges (1973), thus further bearing out the conclusion that exospheric flow is the dominant process governing the global distribution of hydrogen.

Brinton, H. C.↗

The effect of hydrogen on the deformation and fracture behavior of a single crystal nickel-base superalloy

The room temperature and 300 C tensile behavior of a single crystal superalloy, PWA 1480, has been studied as a function of internal hydrogen concentration and microstructure. Hydrogen is trapped at the porosity and eutectic gamma/gamma in the microstructure, and the effect of these trapping sites on the tensile behavior will be discussed. There is no effect of hydrogen on strength, however, the strain to failure decreases steadily with increasing hydrogen content up to 200 ppm. Cleavage of the eutectic gamma/gamma occurs without hydrogen, but the presence of internal hydrogen causes cracking in the eutectic gamma/gamma at a much earlier stage of deformation leading to a small total strain. In contrast to many superalloys with a high volume fraction of gamma precipitates, there was no evidence of shearing of the gamma, and it was found that at all strains the dislocations are trapped in the gamma matrix. The effect of hydrogen on this behavior and its relation to fracture is described.

Walston, W. S.↗

Electrical enclosure hydrogen intrusion study

As a cost savings measure for the space shuttle program, the feasibility of substituting dry air for nitrogen as the purge gas used to minimize the probability of fire and explosions which could erupt from propellant vapor (hydrogen) diffusion into the electrical enclosures at Launch Complex 39 was investigated. It was concluded that: (1) Hydrogen concentrations of approximately 1% were obtained in an electrical enclosure under design purge conditions. (2) Hydrogen concentrations exceeding the lower explosive limit, 4%, could probably be obtained within the enclosure under worst case conditions. (3) Most of the hydrogen intrusion into the enclosure probably occurred at the point with the shortest leak path, such as the door seal. (4) More stringent electrical enclosure design requirements should be imposed before air is using as a purge gas.

Welch, P. J.↗

Epithermal Neutron Evidence for a Diurnal Surface Hydration Process in the Moon's High Latitudes

We report evidence from epithermal neutron flux observations that show that the Moon's high latitude surfaces are being actively hydrated, dehydrated and rehydrated in a diurnal cycle. The near-surface hydration is indicated by an enhanced suppression of the lunar epithermal neutron leakage flux on the dayside of the dawn terminator on poleward-facing slopes (PFS). At 0600 to 0800 local-time, hydrogen concentrations within the upper 1 meter of PFS are observed to be maximized relative to equivalent equator-facing slopes (EFS). During the lunar day surface hydrogen concentrations diminish towards dusk and then rebuild overnight. Surface hydration is determined by differential comparison of the averaged EFS to PFS epithermal neutron count rates above +/- 75 deg latitude. At dawn the contrast bias towards PFS is consistent with at least 15 to 25 parts-per-million (ppm) hydrogen that dissipates by dusk. We review several lines of evidence derived from temperature and epithermal neutron data by a correlated analysis of observations from the Lunar Reconnaissance Orbiter's (LRO) Lunar Exploration Neutron Detector (LEND) that were mapped as a function of lunar local-time, Lunar Observing Laser Altimeter (LOLA) topography and Diviner (DLRE) surface temperature.

diurnal cycles↗

Effects of Surface Treatments on Secondary Electron Emission from CVD Diamond Films

Secondary electron emission (SEE) properties of polycrystalline diamond films grown by chemical vapor deposition (CVD) were measured. The total secondary yield (sigma) from as-grown samples was observed to be as high as 20 at room temperature and 48 while heating at 700 K in vacuum. Electron-beam-activated, alkali-terminated diamond films have shown stable values of sigma as high as 60 when coated with CsI and similarly high values when coated with other alkali halides. Diamond coated with BaF2 had a stable sigma of 6, but no enhancement of the SEE properties was observed with coatings of Ti or Au. Hydrogen was identified to give rise to this effect in as-grown films. However, electron beam exposure led to a reduction in sigma values as low as 2. Exposure to a molecular hydrogen environment restored sigma to its original value after degradation, and enabled stable secondary emission during electron beam exposure. Atomic hydrogen and hydrogen plasma treatments were performed on diamond/Mo samples in an attempt to increase the near-surface hydrogen concentration which might lead to increased stability in the secondary emission. Raman scattering analysis, scanning electron microscopy, and Auger electron spectroscopy (AES) confirmed that hydrogen plasma and atomic hydrogen treatments improved the quality of the CVD diamond significantly. Elastic recoil detection (ERD) showed that heating as-grown diamond targets to 7OO K, which was correlated with an increase in sigma, removed contaminants from the surface but did not drive hydrogen from the diamond bulk. ERD showed that the hydrogen plasma treatment produced an increase in the hydrogen concentration in the near-surface region which did not decrease while heating in vacuum at 700 K, but no improvement in the SEE properties was observed.

Mearini, G. T.↗

Integrated investigation of the mixed origin of lunar sample 72161,11

The comminution-agglutination model and the solar-wind implantation-retention model are used to postulate the origins of the particulate components of lunar sample (72161,11), a submillimeter fraction of a surface sample for the dark mantle regolith at LRV-3. Grain-size analysis was performed by wet sieving with liquid argon, and analyses for CO2, CO, CH4, and H2 were carried out by stepwise pyrolysis in a helium atmosphere. The results indicate that the present sample is from a mature regolith, but the agglutinate content is only 30% in the particle-size range between 90 and 177 microns, indicating an apparent departure from steady state. Analyses of the carbon, methane, and hydrogen concentrations in size fractions larger than 149 microns show that the volume-correlated component of these species increases with increased grain size. It is suggested that the observed increase can be explained in terms of mixing of a dominant local population of coarser agglutinates having high carbon and hydrogen concentrations with an imported population of finer agglutinates relatively poor in carbon and hydrogen.

Basu, A.↗

Role of Hydrogen and Structure on CMSX-2

The goal was to characterize and understand the detailed effect of hydrogen on the tensile and fatigue behavior of single crystals of CMSX-2. Specimens were solutionized, air cooled, and then aged in one of two ways. The resultant macro and microstructure included a pronounced dendritic structure with numerous low angle boundaries in the interdendritic region and on the average a high level of porosity with a large variation in size and distribution. Hydrogen permeability and diffusivity in this material was found to be very low at room temperature. Hydrogen concentration studies on thin samples yielded values significantly higher than found for similar charging conditions in nickel and stainless steels. The tensile mechanical properties were found to depend on hydrogen concentration. SEM observations of the brittle subsurface zone revealed a strong correlation between crack initiation sites and voids just beneath the surface. The hollow and solid samples were compared to better understand the influence of increased charged volume on the fatigue behavior.

Baker, C. L.↗

Latitudinal variation of thermospheric hydrogen near solstice from AE-D observations

Variations of thermospheric neutral atomic hydrogen with latitude during a solstice season near solar minimum were investigated using data acquired with the polar-orbiting AE-D satellite. Hydrogen concentrations at low latitude were found to be comparable to those found from observations with the AE-E satellite, but were slightly higher than concentrations derived from the 1983 mass spectrometer incoherent scatter atmospheric model. Results confirm the general summer-to-winter density increase, large latitudinal gradients in the summer hemisphere, and the winter enhancement of hydrogen observed in AE-C nighttime measurements. The AE-D data, however, show a small polar depression in hydrogen concentration at high winter latitudes, attributed to atmospheric dynamics following auroral heating. The density gradients observed by AE-D in the summer hemisphere were in sharp contrast to the more constant horizontal daytime profiles reported from OGO-6 and previous AE-C measurements, indicating the possibility of local time effects.

Sanatani, S.↗

Resource Prospector Instrumentation for Lunar Volatiles Prospecting, Sample Acquisition and Processing

Data gathered from lunar missions within the last two decades have significantly enhanced our understanding of the volatile resources available on the lunar surface, specifically focusing on the polar regions. Several orbiting missions such as Clementine and Lunar Prospector have suggested the presence of volatile ices and enhanced hydrogen concentrations in the permanently shadowed regions of the moon. The Lunar Crater Observation and Sensing Satellite (LCROSS) mission was the first to provide direct measurement of water ice in a permanently shadowed region. These missions with other orbiting assets have laid the groundwork for the next step in the exploration of the lunar surface; providing ground truth data of the volatiles by mapping the distribution and processing lunar regolith for resource extraction. This next step is the robotic mission Resource Prospector (RP). Resource Prospector is a lunar mission to investigate 'strategic knowledge gaps' (SKGs) for in-situ resource utilization (ISRU). The mission is proposed to land in the lunar south pole near a permanently shadowed crater. The landing site will be determined by the science team with input from broader international community as being near traversable landscape that has a high potential of containing elevated concentrations of volatiles such as water while maximizing mission duration. A rover will host the Regolith & Environment Science and Oxygen & Lunar Volatile Extraction (RESOLVE) payload for resource mapping and processing. The science instruments on the payload include a 1-meter drill, neutron spectrometer, a near infrared spectrometer, an operations camera, and a reactor with a gas chromatograph-mass spectrometer for volatile analysis. After the RP lander safely delivers the rover to the lunar surface, the science team will guide the rover team on the first traverse plan. The neutron spectrometer (NS) and near infrared (NIR) spectrometer instruments will be used as prospecting tools to guide the traverse path. The NS will map the water-equivalent hydrogen concentration as low as 0.5% by weight to an 80 centimeter depth as the rover traverses the lunar landscape. The NIR spectrometer will measure surficial H2O/OH as well as general mineralogy. When the prospecting instruments identify a potential volatile-rich area during the course of a traverse, the prospect is then mapped out and the most promising location identified. An augering drill capable of sampling to a depth of 100 centimeters will excavate regolith for analysis. A quick assay of the drill cuttings will be made using an operations camera and NIR spectrometer. With the water depth confirmed by this first auguring activity, a regolith sample may be extracted for processing. The drill will deliver the regolith sample to a crucible that will be sealed and heated. Evolved volatiles will be measured by a gas chromatograph-mass spectrometer and the water will be captured and photographed. RP is a solar powered mission, which given the polar location translates to a relatively short mission duration on the order of 4-15 days. This short mission duration drives the concept of operations, instrumentation, and data analysis towards critical real time analysis and decision support. Previous payload field tests have increased the fidelity of the hardware, software, and mission operations. Current activities include a mission level field test to optimize interfaces between the payload and rover as well as better understand the interaction of the science and rover teams during the mission timeline. This paper will include the current status of the science instruments on the payload as well as the integrated field test occurring in fall of 2015. The concept of operations will be discussed, including the real time science and engineering decision-making process based on the critical data from the instrumentation. The path to flight will be discussed with the approach to this ambitious low cost mission.

ISRU↗

Lunar Water Resource Demonstration

In cooperation with the Canadian Space Agency, the Northern Centre for Advanced Technology, Inc., the Carnegie-Mellon University, JPL, and NEPTEC, NASA has undertaken the In-Situ Resource Utilization (ISRU) project called RESOLVE. This project is a ground demonstration of a system that would be sent to explore permanently shadowed polar lunar craters, drill into the regolith, determine what volatiles are present, and quantify them in addition to recovering oxygen by hydrogen reduction. The Lunar Prospector has determined these craters contain enhanced hydrogen concentrations averaging about 0.1%. If the hydrogen is in the form of water, the water concentration would be around 1%, which would translate into billions of tons of water on the Moon, a tremendous resource. The Lunar Water Resource Demonstration (LWRD) is a part of RESOLVE designed to capture lunar water and hydrogen and quantify them as a backup to gas chromatography analysis. This presentation will briefly review the design of LWRD and some of the results of testing the subsystem. RESOLVE is to be integrated with the Scarab rover from CMIJ and the whole system demonstrated on Mauna Kea on Hawaii in November 2008. The implications of lunar water for Mars exploration are two-fold: 1) RESOLVE and LWRD could be used in a similar fashion on Mars to locate and quantify water resources, and 2) electrolysis of lunar water could provide large amounts of liquid oxygen in LEO, leading to lower costs for travel to Mars, in addition to being very useful at lunar outposts.

Muscatello, Anthony C.↗

Visual hydrogen detector with variable reversibility

Methods, processes and compositions are provided for a visual or chemochromic hydrogen-detector with variable or tunable reversible color change. The working temperature range for the hydrogen detector is from minus 100.degree. C. to plus 500.degree. C. A hydrogen-sensitive pigment, including, but not limited to, oxides, hydroxides and polyoxo-compounds of tungsten, molybdenum, vanadium, chromium and combinations thereof, is combined with nano-sized metal activator particles and preferably, coated on a porous or woven substrate. In the presence of hydrogen, the composition rapidly changes its color from white or light-gray or light-tan to dark gray, navy-blue or black depending on the exposure time and hydrogen concentration in the medium. After hydrogen exposure ceases, the original color of the hydrogen-sensitive pigment is restored, and the visual hydrogen detector can be used repeatedly. By changing the composition of the hydrogen-sensitive pigment, the time required for its complete regeneration is varied from a few seconds to several days.

Muradov, Nazim↗

Visual hydrogen detector with variable reversibilty

Methods, processes and compositions are provided for a visual or chemochromic hydrogen-detector with variable or tunable reversible color change. The working temperature range for the hydrogen detector is from minus 100.degree. C. to plus 500.degree. C. A hydrogen-sensitive pigment, including, but not limited to, oxides, hydroxides and polyoxo-compounds of tungsten, molybdenum, vanadium, chromium and combinations thereof, is combined with nano-sized metal activator particles and preferably, coated on a porous or woven substrate. In the presence of hydrogen, the composition rapidly changes its color from white or light-gray or light-tan to dark gray, navy-blue or black depending on the exposure time and hydrogen concentration in the medium. After hydrogen exposure ceases, the original color of the hydrogen-sensitive pigment is restored, and the visual hydrogen detector can be used repeatedly. By changing the composition of the hydrogen-sensitive pigment, the time required for its complete regeneration is varied from a few seconds to several days.

Muradov, Nazim Z.↗