At least 55 records · Page 3

An NMR study of microvoids in polymers

An understanding of polymer defect structures, like microvoids in polymeric matrices, is crucial to their fabrication and application potential. In this project guest atoms are introduced into the microvoids in PMR-15 and NMR is used to determine microvoid sizes and locations. Xenon is a relatively inert probe that would normally be found naturally in polymer or in NMR probe materials. There are two NMR active xenon isotopes, Xe-129 and Xe-131. The Xe atom has a very high polarizability, which makes it sensitive to the intracrystalline environment of polymers. Interactions between the Xe atoms and the host matrix perturb the Xe electron cloud, deshielding the nuclei, and thereby expanding the range of the observed NMR chemical shifts. This chemical shift range which may be as large as 5000 ppm, permits subtle structural and chemical effects to be studied with high sensitivity. The Xe(129)-NMR line shape has been found to vary in response to changes in the pore symmetry of the framework hosts line Zeolites and Clathrasil compounds. Before exposure to Xe gas, the PMR-15 samples were dried in a vacuum oven at 150 C for 48 hours. The samples were then exposed to Xe gas at 30 psi for 72 hours and sealed in glass tubes with 1 atmosphere of xenon gas. Xenon gas at 1 atmosphere was used to tune up the spectrometer and to set up the appropriate NMR parameters. A single Xe-129 line at 83.003498 Mhz (with protons at 300 Mhz) was observed for the gas. With the xenon charged PMR-15 samples, a second broader line is observed 190 ppm downfield from the gas line (also observed). The width of the NMR line from the Xe-129 absorbed in the polymer is at least partially due to the distribution of microvoid sizes. From the chemical shift (relative to the gas line) and the line width, we estimate the average void sizes to be 2.74 +/- 0.20 angstroms. Since Xe-129 has such a large chemical shift range (approximately 5000 ppm), we expect the chemical shift anisotropy to contribute to the line width (delta upsilon = 2.5 kHz).

Toy, James↗

Technology Assessment for Radioiodine at the Hanford Site - 20240

An evaluation was conducted to assess the practicability of technologies of sufficient promise and maturity to warrant treatability tests for remediating radioiodine (I-129) in groundwater at the 200-UP-1 operable unit at the U.S. Department of Energy Hanford Site. Technologies were evaluated based on recent updated knowledge of subsurface iodine transport behavior at Hanford, and the effectiveness, implementability, and cost of potential treatment technologies for I-129. Because more than two-thirds of the iodine at Hanford is estimated to be present in its oxidized form as iodate, treatment technologies were evaluated with respect to addressing iodate. In situ treatments were identified as having limited implementability because the plume core is located directly beneath the Environmental Restoration Disposal Facility disposal cells, a landfill used for the disposal of low-level radioactive, hazardous, and mixed wastes generated from Hanford cleanup activities. Further limitations in treatment technologies for radioiodine were due to the isotopic distribution of subsurface iodine. Data indicate that stable iodine (I- 127) concentrations are up to three orders of magnitude greater than I-129, limiting the effectiveness of potential technologies because they are not isotope-specific. Ex situ approaches also lacked the effectiveness and maturity required to treat I-129. Hence, the technology evaluation did not identify any technologies that needed treatability testing, driven by site and contaminant properties that hinder effectiveness and/or implementability of the technologies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Iodine Co-Precipitation with Calcium Carbonate in the Presence of Silica Ions - 20360

Historical releases of I-129 to the subsurface at the U.S. Department of Energy Hanford Site have resulted in large dilute plumes that cover an area of over 50 km{sup 2}. The most concentrated I-129 plume is associated with the 200 West Area in the 200-UP-1 operable unit of the Hanford Central Plateau, where peak concentrations have been measured up to 30 times the drinking water standard of 1 pCi/L. The mobility of iodine depends on many factors, including chemical speciation, pH, redox conditions, as well as the presence of organic matter, calcium carbonate minerals and microbial activities. Speciation measurements estimate that the majority of the iodine (∼76%) in Hanford groundwater exists as iodate. Information on processes that affect iodate mobility in the Hanford subsurface support evaluation of environmental management options for the I-129 plumes. Iodate can be incorporated into calcium carbonate, which is a potential mechanism of naturally attenuating radioiodine in groundwater. However, the silica content in porewater may impact the contaminant-calcium carbonate incorporation process. Silica is one of the most abundant elements in nature and can have an impact on chemical weathering of alkaline-earth carbonates in the environment. Hence, this research aims to advances knowledge of the iodine co-precipitation process with calcium carbonate in the presence of silica. This information supports the technical basis evaluation of natural attenuation for I-129. Samples for these studies were prepared using calcium carbonate-forming solutions that included certified grade sodium meta-silicate nonahydrate (Na{sub 2}SiO{sub 3}), calcium chloride dehydrate (CaCl{sub 2}.2H{sub 2}O), sodium carbonate (NaCO{sub 2}), and sodium hydroxide (NaOH) solutions for pH adjustments. Triplicate samples were prepared with silica concentrations in the solution of 0 mM, 0.5 mM and 20 mM, mixed with an iodate standard (1000 ppm of IO{sub 3}{sup -} in H{sub 2}O) and sampled over a one-week period. Preliminary data analyses suggest that less iodine remains in solution in the presence of silica (average remaining aqueous fraction 0.23±0.03 at 20 mM of Si) relative to samples without silica (0.52±0.06); an indication that more iodine has been sorbed or incorporated into precipitates. However, the mechanisms for this behavior are still under investigation and need to be interpreted relative to pore water compositions that are representative of Hanford site-specific conditions. Scanning electron microscope equipped with energy dispersive spectroscopy (SEM-EDS) analyses were performed to observe the solid phase morphology in these experiments and showed rhombohedral calcite crystals covered with amorphous Si floccules. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Results for the August 2025 Tank Farm 2H Evaporator Overhead Sample

On an annual basis, Savannah River Mission Completion (SRMC) provides 2H and 3H evaporator overhead samples to Savannah River National Lab (SRNL) to be analyzed per Section 5.2 of the Effluent Treatment Project (ETP) Waste Compliance Plan (WCP) and the Waste Acceptance Criteria (WAC). This report presents the average characterization results for the August 2025 2H evaporator overhead sample. The sample was clear and colorless with no visible solids. The results provide measurements for cesium-137 ( 137 Cs), strontium-90 ( 90 Sr), and iodine-129 ( 129 I) with the radionuclide concentration limits specified by the WAC. These analyses were performed in duplicate, and all three measured radionuclide concentrations were within ETP WAC limits. A summary of the analytical results for this 2H evaporator overhead sample includes the following: The measured cesium-137 activity in the 2H evaporator overhead sample averaged 3.02E+02 dpm/mL, which is below the ETP WAC limit of 1.30E+03 dpm/mL. The strontium-90 activity in the 2H evaporator overhead sample averaged 3.33E+00 dpm/mL, which is below the ETP WAC limit of 1.76E+02 dpm/mL. The iodine-129 activity in the 2H evaporator overhead sample averaged 1.20E-01 dpm/mL, which is below the ETP WAC limit of 1.00E+00 dpm/mL. Although the measurements for Cs-137 and Sr-90 are lower compared to previous years, the results remain within a similar range to past measurements and are well below the WAC limits. Iodine-129 indicates detectable results compared to previous years, which can be attributed to recent salt batch processing trending close to the WAC limit for saltstone production. However, these results are still below the ETP WAC limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment for the E-Area Low-Level Radioactive Waste Disposal Facility at the Savannah River Site: Appendix E

Supplemental transport model results for the LAWV from Chapter 5, Section 5.2.2 are provided in Section E.1.1 to compare concentrations at the 100-meter POA for the nominal PA case, best estimate case, and various sensitivity cases (Figure E-1 through Figure E-12). Second, Figure E-13 through Figure E-30 in Section E.1.2 display concentrations at the 100-meter POA for decay-chain daughter and parent radionuclides. Third, Figure E-31 through Figure E-34 in Section E.1.3 show maximum concentration contours for I-129. Only contour plots for I-129 from the remaining sensitivity runs are shown because I-129 is identified as the only radionuclide that impacts disposal limits for the LAWV. All concentration units, whether noted or not in the y-axis labels, are pCi L-1 per Ci parent buried.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comments on 'Extinct radioactivities: Trapped residuals of presolar grains'

It has recently been suggested that extinct I-129 and Pu-244 were trapped in primitive-solar-nebula ('presolar') grains and decayed into radiogenic Xe-129 and fission Xe before the grains were incorporated into meteorite bodies. This idea is reconsidered in light of the thermal and metamorphic history of meteorites. The criteria that parent and daughter species should never separate and that minerals or grains containing the anomalous xenon should not be subjected to temperatures exceeding 500 C are applied to iron meteorites, achondrites, and chondrites to determine whether presolar grains could be the carriers of rare-gas anomalies to meteorites. The results strongly indicate that the xenon anomaly could not have originated in presolar grains. Other difficulties with the presolar-grain model are discussed, including insufficiently small grain sizes, large variations in Xe-129/I-127 ratios in various meteorites, and apparently unrealistic meteorite formation times and locations.

Trivedi, B. M. P.↗

Krypton and xenon in Apollo 14 samples - Fission and neutron capture effects in gas-rich samples

Gas-rich Apollo 14 breccias and trench soil are examined for fission xenon from the decay of the extinct isotopes Pu-244 and I-129, and some samples have been found to have an excess fission component which apparently was incorporated after decay elsewhere and was not produced by in situ decay. Two samples have excess Xe-129 resulting from the decay of I-129. The excess is correlated at low temperatures with excess Xe-128 resulting from neutron capture on I-127. This neutron capture effect is accompanied by related low-temperature excesses of Kr-80 and Kr-82 from neutron capture on the bromine isotopes. Surface correlated concentrations of iodine and bromine are calculated from the neutron capture excesses.

Drozd, R.↗

I-Xe systematics in LL chondrites

A stepwise heating analysis of Ar and Xe data from five neutron-irradiated whole rock LL chondrites (Soko Banja, Alta Ameen, Tuxtuac, Guidder, and Olivenza) is presented, emphasizing the complicated thermal history of ordinary chondrites. None of the present meteorites show a well-defined (Ar-40)-(Ar-39) apparent age plateau comprised of more than two release fractions. Most of the samples are found to yield well-defined high-temperature correlations between Xe-129/Xe-130 and Xe-128/Xe-130, and thus determinations of I-129/I-127 and Xe-129/Xe-130 at the time of isotopic closure for Xe. As in the case of other ordinary chondrites, the I-Xe systematics for LL chondrites correlate neither with a metamorphic grade nor with chronologies based opon other methods.

Bernatowicz, T. J.↗

Forsterite/melt partitioning of argon and iodine: Implications for atmosphere formation by outgassing of an early Martian magma ocean

Argon and Xe in the Martian atmosphere are radiogenic relative to the Martian mantle if the SNC meteorites are from Mars. Decay of the short lived isotope I-129 to Xe-129 (t sub 1/2 = 16 m.y.) is the most plausible source of the radiogenic Xe. This short half life constrains any process responsible for the elevated Xe-129/Xe-132 ratio of the Martian atmosphere to occur very early in solar system history. Musselwhite et al. proposed that the differential solubility of I and Xe in liquid water played a key role in producing the radiogenic signature in the Martian atmosphere. Here we explore an alternative hypothesis involving purely igneous processes, and motivated in part by new experimental results on the partitioning of I and Xe between minerals and melt.

Musselwhite, Donald S.↗

Fractionated martian atmosphere in the nakhlites?

Considerable evidence points to a martian origin of the shergottite-nakhlite-chassignite (SNC) meteorites. Noble gas isotopic compositions have been measured in most SNC meteorites. The Xe-129/Xe-132 vs. Kr-84/Xe-132 ratios in Chassigny, most shergottites, and lithology C of EETA 79001 define a linear array. This array is thought to be a mixing line between martian mantle and martian atmosphere. One of the SNC meteorites, Nakhla, contains a leachable component that has an elevated Xe-129/Xe-132 ratio relative to its Kr-84/Xe-132 ratio when compared to this approximately linear array. The leachable component probably consists in part of iddingsite, an alteration product produced by interaction of olivine with aqueous fluid at temperatures lower than 150 C. The elevated Xe isotopic ratio may represent a distinct reservoir in the martian crust or mantle. More plausibly, it is elementally fractionated martian atmosphere. Formation of sediments fractionates the noble gases in the correct direction. The range of sediment/atmosphere fractionation factors is consistent with the elevated Xe-129/Xe-132 component in Nakhla being contained in iddingsite, a low temperature weathering product. The crystallization age of Nakhla is 1.3 Ga. Its low-shock state suggests that it was ejected from near the surface of Mars. As liquid water is required for the formation of iddingsite, these observations provide further evidence for the near surface existence of aqueous fluids on Mars more recently than 1.3 Ga.

Drake, Michael J.↗

Calibration of the Galactic Cosmic Ray Flux

We report first Xe data on the cross-calibration of I-129-Xe-129(sub n) ages with conventional CRE ages, a method which is expected to provide information on the long-term constancy of the galactic cosmic ray (GCR) flux. We studied isotopic signatures of Xe released in stepwise heating, decomposition and melting of troilites in the Cape York iron meteorite to identify isotopic shifts in Xe-129 and Xe-131 due to neutron capture in Te-128 and Te-130. We also resolve components due to extinct 129I, spallation and fission Xe. There has recently been much speculation on the constancy of GCR over long time scales, as may be inferred from iron meteorites. If GCRs originate from supernova events, this provides the basis for postulating increased fluxes at locations with higher than average densities of supernovae, specifically in OB-associations. The solar system at present appears to be inside a local bubble between spiral arms and may experience an increased GCR flux.

Mathew, K. J.↗

Characterization Results for the September 2023 Tank Farm 3H Evaporator Overhead Sample

On an annual basis, Savannah River Mission Completion (SRMC) provides 2H and 3H evaporator overhead samples to Savannah River National Lab (SRNL) to be analyzed per Section 5.2 of the Effluent Treatment Project (ETP) Waste Compliance Plan (WCP) and the Waste Acceptance Criteria (WAC). This report presents the average characterization results for the September 2023 3H evaporator overhead sample. The sample was clear and colorless with no visible solids. The results provide measurements for cesium-137 ( 137 Cs), strontium-90 ( 90 Sr), and iodine-129 ( 129 I) with the radionuclide concentration limits specified by the WAC. These analyses were performed in duplicate, and all three measured radionuclide concentrations were within ETP WAC limits. A summary of the analytical results for this 3H evaporator overhead sample includes the following: The measured cesium-137 activity in the 3H evaporator overhead sample averaged 5.70E+01 dpm/mL, which is below the ETP WAC limit of 1.30E+03 dpm/mL. As seen through historical results, Cs-137 continues to present a decreasing activity since 2020. The strontium-90 activity in the 3H evaporator overhead sample averaged <2.16E00 dpm/mL, which is below the ETP WAC limit of 1.76E+02 dpm/mL. The iodine-129 activity in the 3H evaporator overhead sample averaged <9.08E-02 dpm/mL, which is below the ETP WAC limit of 1.00E+00 dpm/mL

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Results for the October 2024 Tank Farm 3H Evaporator Overhead Sample

On an annual basis, Savannah River Mission Completion (SRMC) provides 2H and 3H evaporator overhead samples to Savannah River National Lab (SRNL) to be analyzed per Section 5.2 of the Effluent Treatment Project (ETP) Waste Compliance Plan (WCP) and the Waste Acceptance Criteria (WAC). This report presents characterization results for the October 2024 3H evaporator overhead sample. The sample was clear and colorless with no visible solids. The results provide measurements for cesium-137 (137Cs), strontium-90 (90Sr), and iodine-129 (129I) with the radionuclide concentration limits specified by the WAC. These analyses were performed in duplicate, and a summary of the analytical results for this 3H evaporator overhead sample includes the following: The measured cesium-137 activity in the 3H evaporator overhead sample averaged 6.72E+01 dpm/mL, (3.90E+00 %RSD), which is below the ETP WAC limit of 1.30E+03 dpm/mL. The strontium-90 activity in the 3H evaporator overhead sample averaged <2.72E+00 dpm/mL, which is below the ETP WAC limit of 1.76E+02 dpm/mL. The iodine-129 activity in the 3H evaporator overhead sample averaged <1.63E-01 dpm/mL, which is below the ETP WAC limit of 1.00E+00 dpm/mL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Spent Purolite A530E Resin with Implications for Long-Term Radioactive Contaminant Removal

Direct removal of pertechnetate anion (TcO4-) from the subsurface contaminated plumes at legacy nuclear weapons production sites, is effective remediation strategy to prevent their spread to adjacent aquifers but is also challenging because TcO4- is a trace component of the contaminated groundwater typically containing large access of other anionic constituents, such nitrate, sulfate, chloride and others. It can be achieved through ion exchange treatment using Purolite A530E resin which to date however has only been evaluated under laboratory conditions and many questions regarding its long-term operational performance remain. To address this need, here we report comprehensive characterization of the spent Purolite A530E resin which processed over 5.38x109 L of contaminated groundwater and successfully removed about 3.78 Ci of Tc-99 during four years of operation at the 200 West Pump & Treat facility at the US DOE Hanford site. This Tc-99 loading constitutes however only about 0.034% of the theoretical capacity of the resin which retained significant amounts of sulfate. Among other radioactive contaminants, small quantities of U-238, Co-60, and I-129 were retained by the resin. The total loading of iodine (combined 1-127 and I-129) on the spent resin exceeded that of Tc-99. To elucidate the mechanism of iodine retention, ion exchange behavior of iodide and iodate was investigated. Purolite A530E resin exhibited highly efficient uptake of iodide and only moderate affinity for iodate in accord with their Gibbs energy of hydration. Sorption isotherms for both anions obeyed Freundlich model.

Levitskaia, Tatiana G.↗

Using Radioiodine Speciation to Address Environmental Remediation and Waste Stream Sequestration Problems at the Fukushima Daiichi Nuclear Power Plant and a DOE Site

Iodine-129 ( 129 I), with a half-life of half-life of 16 million years, is commonly considered the single greatest risk driver in high-level and low-level nuclear repositories. This risk stems from several basic properties of 129 I, and under many geochemical conditions, it can move as an anion at nearly the rate of water through the subsurface environment. 129 I is also extremely radiologically toxic because over 90% of body burden accumulates in the thyroid, which weighs only about 14g in an adult. There is also a large worldwide inventory of radioiodine as a result of its high fission yield and this inventory is rapidly increasing as a result of nuclear energy production. Radioiodine is produced at a rate of 40 GBq (1 Ci) per gigawatt of electricity produced by nuclear power. To illustrate how the properties of 129 I magnify its risk, 129 I accounts for only 0.00002% of the radiation released from the Savannah River Site in Aiken, South Carolina, but contributes 13% of the population dose, a six orders of magnitude magnification of risk with respect to its radioactivity. The currently favored solid phase for LLW immobilization is cement, while HLW immobilization is the incorporation of waste into glass (vitrification). However, so far, the incorporation into cement and subsequent leaching of only iodide has been seriously investigated. The major problem with this approach is that it ignores the complex speciation of iodine, i.e., it ignores iodate and organo-iodine which have different chemistries. Most of the past research was devoted to the mechanism of iodide uptake in cement hydrate phases that is sorption and/or incorporation. Very few data exist on iodate and organo-iodine incorporation in cement, even though large quantities of liquid waste containing also radioiodine have already been solidified in cement Iodine-129 from low-level waste is commonly disposed of in cementitious materials. Grout, a dense cementitious fluid, mixed with a reducing slag, is often used to immobilize radionuclides. However, the reducing environment might not be conducive to immobilize iodine. For example, the silver based immobilization technologies (e.g., AgCl, Ag-impregnated granular activated carbon, Ag-mordenite) remove iodine from the aqueous phase by promoting the formation of Ag-iodide precipitates. The solubility of AgI is eight orders of magnitude lower than it is for AgIO 3 . Similarly, coprecipitation of iodine into calcium carbonate phases occurs only with IO 3 - and not with I - and org-I. If one would want to immobilize iodine more effectively, different engineering approaches would need to be used to promote binding of I - , IO 3 - , or organo-I. Using laboratory experiments with grout, slag, and silver-based adsorbents, and GC-MS and I K-edge XANES and EXAFS and C K-edge XANES spectroscopy for identifying iodine speciation, the major problems with these methods have been identified as focused too much on just one of the iodine species for immobilization, while others, especially organo-I, remained mobile. Finally, we established that most of the adsorbents that are used contain sufficient amounts of organic matter to create organo-I . It is anticipated that increased attention directed at understanding and quantifying the speciation of radioiodine, as opposed to simply total radioiodine, will lead to improved remediation results to be used for long-term radioiodine disposal in cementitious waste forms.

129-Iodine↗

Vadose Zone Model for B-63 Area for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort; carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP1) simulator, officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP), is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the P2R model. The rates will be summed over the 100 by 100 m P2R grid cells that fall within the vadose zone model source domain.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose Zone Model for REDOX Area for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort: carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP1) simulator, officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP), is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the P2R model. The rates will be summed over the 100 by 100 m P2R grid cells that fall within the vadose zone model source domain.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose Zone Model for U Plant Area for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort: carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP1) simulator, officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP), is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the P2R model. The rates will be summed over the 100 by 100 m P2R grid cells that fall within the vadose zone model source domain.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗