Energy efficiency for the growing South Carolina manufacturing industries. Final Report

The overall goals of the proposed project were to establish a DOE Industrial Assessment Center with Clemson University as the main center and to cement the Clemson IAC as the "go to" resource for energy efficiency expertise and assistance to manufacturing businesses in the state of South Carolina. The Clemson IAC included a satellite support center through partnership with the SCE&G Energy Innovation Center at the Clemson University Restoration Institute (CURI) in North Charleston, SC. The Clemson IAC was the first IAC based in the state with the goal to serve the entire state. The Clemson IAC provided SMEs with no-cost energy assessments, trained the next generation of energy-savvy engineers, and provided outreach to non-participating SMEs. Project objectives were structured into five 12-month Budget Periods. In the first Budget Period, the primary objective was to establish methods and materials for Clemson IAC assessments, training, and outreach. In the remaining Budget Periods, the primary objectives were to perform assessments, train students, and pursue outreach to hard-to-reach SMEs that did not participate in energy assessments. Expected outcomes in the first Budget Period included the development of standard procedures for performing energy assessments, including data acquisition, processing, and communication both within the team and in assessment reports prepared for SMEs. Outcomes related to student training in the first Budget Period included detailed curriculum and internship plans for students pursuing the DOE IAC Certificate and energy-related Clemson University certificates. Outcomes in the first Budget Period also included the development of outreach materials and plans for outreach events. In Budget Periods 2 through 5, major expected outcomes are trained students and completed energy assessments and reports for SMEs. Decision points and Go-No Go criteria for the end of each Budget Period, presented in more detail below, are based on the number of students in training and the number of energy assessments performed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Technical Report for Industrial Assessment Center at West Virginia University

The Industrial Assessment Center (IAC) program at West Virginia University (WVU), which is funded by the Industrial Technologies Program (ITP) in the U.S. Department of Energy’s (DOE) Office of Energy Efficiency and Renewable Energy (EERE), has provided a unique opportunity to enhance efficient energy utilization in small to medium-sized manufacturers. It has also provided training to engineering students in the identification and analysis of efficient energy use in each aspect of the manufacturing process and associated supporting elements. The outcomes of the IAC Program at WVU have assisted the manufacturers and the students in having a heightened sensitivity to industrial energy conservation, waste reduction, and productivity improvement, as well as a better understanding of the technical aspects of manufacturing processes and the supporting elements through which efficient energy utilization can be enhanced. The IAC at WVU has conducted 101 energy assessments from 2002 until 2006. The focus of the industrial assessments has been on energy savings. It has been the IAC’s interest to strongly focus on energy savings and on waste minimization and productivity improvements that strictly have an impact on energy. The IAC at WVU was selected as the Center of the year in 2005 from amongst 26 centers and has obtained a ranking within the top 5 in the previous few years. From 2002 to 2006, the total recommended energy savings produced by the IAC at WVU is 1,214,414 MMBtu, of which the electricity accounts for 93,826,067 kWh (equivalent to 320,226 MMBtu) and natural gas for 871,743 MMBtu. The balance is accounted for in savings in other fuels, mainly coal and wood. This results in an average recommended energy savings of 928,971 kWh from electricity and 8,631 MMBtu from natural gas per facility. The total CO2 emissions saved from 2002 to 2006 is 154,462 tons, with an average of 1,529.3 tons per facility. The average recommended energy cost savings per facility is $135,036. The overall implementation rate of the assessment recommendations is 60.6% for the 101 industrial assessments conducted since 2002. The implemented recommendations resulted in total energy savings of 62,328,006 kWh from electricity, 295,241 MMBtu from natural gas, and 43,593 MMBtu from other fuels, totaling 551,557 MMBtu. The average implemented energy savings per industrial facility is 5,461 MMBtu and the average implemented energy cost savings is $ 59,879. The average implemented energy and productivity cost savings exceeds the program average of $ 60,000 per assessment. The IAC at WVU has produced a variety of energy efficiency recommendations in areas of industrial energy consumption such as Boilers and Steam systems (19), Air Compressors (15), HVAC (4), Chillers (12), Furnaces and Ovens (17), Motors (8), Lighting (20), Insulation (3), CHP and Cogeneration (4), and Process Equipment (7). The project has benefited the public by enabling the reduction of CO2 emissions by 89,726 tons due to the implemented energy saving recommendations at 101 small and medium sized manufacturing facilities. Since CO2 is a green house gas, its reduction will improve the quality of the environment significantly. The reduction in operating costs for the manufacturing facilities in terms of energy cost savings will increase the manufacturing facilities’ profits and improve their competitive edge, thus causing possible expansion in the manufacturing activities, leading to increase in good paying jobs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detection of Candida DNA in peritoneal fluids by PCR assay optimizing the diagnosis and treatment for intra-abdominal candidiasis in high-risk ICU patients: A prospective cohort study

Background Intra-abdominal candidiasis (IAC) is the predominant type of invasive candidiasis with high mortality in critically ill patients. This study aimed to investigate whether the polymerase chain reaction (PCR) assay for detecting Candida DNA in peritoneal fluids (PF) is useful in diagnosing and management of IAC in high-risk patients in intensive care unit (ICU). Methods A prospective single-center cohort study of surgical patients at high risk for IAC was conducted in the ICU. PF was collected from the abdominal drainage tubes (within 24 h) or by percutaneous puncture. Direct PF smear microscopy, PF culture, blood culture, and serum (1–3)-β-D-glucan were performed in all patients. For Candida PCR assay, the ITS1/ITS4 primers that targeted the ITS1-5.8 s-ITS2 regions were used for PCR, and sequencing analysis was used to identify the pathogen at the species level. IAC was defined according to the 2013 European consensus criteria. Results Among 83 patients at high risk for IAC, the IAC criteria were present in 17 (20.5%). The sensitivity and specificity of the Candida PCR assay were 64.7 and 89.4%, respectively, and the area under the receiver operating characteristic curve was 0.77 (95% CI: 0.63–0.91). In this cohort, the positive predictive value and negative predictive value were 90.8% (95% CI: 80.3–96.2%) and 61.1% (95% CI: 36.1–81.7%), respectively. Diagnostic consistency was moderate (kappa 0.529, p < 0.001) according to the 2013 European consensus criteria. Conclusion Detection of Candida DNA in PF using PCR can be considered an adjunct to existing routine diagnostic tools which may optimize the diagnosis and antifungal treatment of IAC in high-risk patients in the ICU.

Xie, Min↗

Colorado State University Extension Industrial Assessment Center

Since its inception in 1984, the Colorado State University Industrial Assessment Center has performed industrial assessments at more than 720 manufacturing facilities in Colorado, Montana, Nebraska, Nevada, New Mexico, North Dakota, South Dakota, Utah, and Wyoming. From 2017 to 2019 there was a funding gap and the IAC shutdown. In 2020 through DOE extension funding the University relaunched the IAC as an extension center in order to provide assessments to underserved areas. Under this award, the CSU Industrial Assessment Center (IAC) was rebuilt with the help of student employees and the director. The CSU team experienced difficulty as the program was in the process of being restarted right as the 2020 pandemic hit. Nonetheless, the CSU IAC was instrumental in providing energy assessments to manufacturers in Colorado and Wyoming during the period of performance of 09/2019 – 12/2022. The Department of Energy's Industrial Assessment Centers (IACs) provide a valuable service to small and medium-sized manufacturers seeking to optimize their operations. These university-based centers offer no-cost, on-site assessments conducted by engineering faculty and students, analyzing energy consumption, production processes, and waste streams. They utilize advanced data acquisition systems to record operational data, and then use the data to create assessment recommendations. These recommendations form the foundation of the comprehensive energy report. The comprehensive report delivers actionable recommendations for enhancing energy efficiency, reducing waste, and reducing greenhouse gas emissions and improving productivity, often identifying significant cost savings. Furthermore, IACs facilitate access to implementation grants, enabling the businesses to readily adopt these improvements. This program not only strengthens individual businesses but also contributes to national goals of training the next generation of energy experts, as well as increasing industrial competitiveness and reduced environmental impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Extension Industrial Assessment Center in Eastern Great Lakes Region

The extension IAC at CWRU is funded for 3 years to conduct 10 assessments of small and medium-sized manufacturing facilities each year in Eastern Great Lakes region. Total 30 assessments was proposed in the SOPO but due to the Covid-19 pandemic, the IAC program was suspended for 1.5 years. A total of 20 assessments was contracted to the extension IAC at CWRU which have been successfully accomplished. In the proposal, we proposed to train 18 students in the extension IAC program, and actually we selected and trained 19 students even though the IAC project was suspended during half of its project period.

42 ENGINEERING↗

Formation of gradient microstructure and mechanical properties of hot-pressed W-20 wt% Cu composites after sliding friction severe deformation

Highlights: • W particles of composites were refined during sliding friction treatment (SFD). • Dislocation, dislocation tangles and boundary clearly exist in deformed W particle. • YS and UTS of SFDed sample are 308.74 MPa and 553.60 MPa owing to the refinement. • Electrical conductivity of SFDed sample decreased from 33 IACS% to 28.5 IACS%. • Fracture mode changing from inter-granular mode to trans-granular. - Abstract: W-based alloys are currently considered promising candidates for high heat flux components in future fusion reactors. In this paper, hot pressed W-20 wt%Cu composites were treated at room temperature using a sliding friction severe deformation (SFD) process, with a moving speed of 0.2 m/s and an applied load of 500 N. Microstructural evolution of composites after the SFD treatment was evaluated and compared with that of the untreated composites. Results showed that there was a gradient structure generated and an obvious refinement in tungsten particles size in the surface layer after the SFD process. The average particle size of tungsten in the SFD treated composites was 2.60 μm, whereas it was 4.5 μm for tungsten in the untreated composites. Fracture surfaces of the composites indicated that the SFD treatment destroyed the W skeleton and changed fracture mode from predominant inter-granular one to trans-granular one due to the decrease in contact area of W-W inter-particles. Yield strength and ultimate tensile strength of composites after the SFD treatment were 308 MPa and 553 MPa, respectively. The treated composites exhibited micro-hardness values with an average reading of about 308 HV. Analysis of the facture microstructures clearly suggested that the tungsten particles in the treated composites are consisted of dislocations and boundaries as well as dislocation tangles. The electrical conductivity of the composites was decreased from 33 IACS% to 28.5 IACS% after the SFD treatment, mainly due to loss or squeezing of copper into the inner surface.

36 MATERIALS SCIENCE↗

Intubation Containment System for Improved Protection From Aerosolized Particles During Airway Management

Worldwide efforts to protect front line providers performing endotracheal intubation during the COVID-19 pandemic have led to innovative devices. Authors evaluated the aerosol containment effectiveness of a novel intubation aerosol containment system (IACS) compared with a recently promoted intubation box and no protective barrier. In a simulation center at the authors’ university, the IACS was compared to no protective barrier and an intubation box. Aerosolization was simulated using a commercial fog machine and leakage of aerosolize mist was visually assessed. The IACS appeared to contain the aerosolized mist, while the intubation box allowed for mist to contact the laryngoscopist and contaminate the clinical space through arm port holes and the open caudal end. Both devices protected the laryngoscopist better than no protective barrier. The IACS with integrated sleeves and plastic drape appears to offer superior protection for the laryngoscopist and assistant providers from aerosolized particles.

aerosols↗

Opportunities for Using the Industrial Assessment Center Database for Industrial Water Use Analysis

The manufacturing sector accounted for approximately 5–6% of total U.S. water use in 2015. Of that amount, 75–80% is self supplied withdrawal from surface-water and groundwater sources and the remainder is from public water supplies. Although manufacturing facilities commonly locate in water-scarce areas, water scarcity still poses a great risk to the manufacturing sector. Reliable water is necessary for any facility that relies on it for process and comfort cooling, cleaning, employee use, and steam generation. One of these barriers to water efficiency is the lack of reliable data on overall U.S. industrial water use—how it is used and the quantities required for each sector. If a facility cannot be easily compared with a facility of similar size and sector, knowing if it is effectively using water conservation best practices is difficult. One potential source of industrial water use data is the U.S. Department of Energy (DOE)–sponsored Industrial Assessment Centers (IACs). IACs are university-based organizations that provide free audits to small- and medium-sized manufacturing facilities to identify productivity improvement and waste and energy reduction opportunities. The IACs also maintain a database of all the audits conducted, which currently holds more than 19,267 assessments and 145,000 recommendations (as of July 24, 2020). This database also contains energy utility (electricity, natural gas, and other fuels) and water utility data, making it a potential data source for industrial water use. This report attempts to create regression models to predict a small- or medium-sized industrial facility’s annual water use or cost based on its industrial subsector and several possible relevant variables. Using data collected by IAC assessments, models for several industrial subsectors were generated via stepwise regression techniques to determine which variables (annual sales, number of employees, facility/plant area, annual production hours, and a water stress metric) are relevant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Industrial Assessment Center – integration of education and practice. Final progress report

The goal of the DOE’s Industrial Assessment Center (IAC) program is twofold: first, to help US manufacturing competitiveness by providing assessments and recommendations for small and medium-sized enterprises (SMEs) on energy efficiency, productivity, sustainability and competitiveness – including measuring the impacts of these recommendations on reducing greenhouse gas emissions; and second, to address a growing shortage of engineering professionals with applied energy and manufacturing-related skills by training a diverse cross-section of engineering students through hands-on involvement in these assessments. IUPUI has an IAC, which was established in 2011, in the Department of Mechanical and Energy Engineering, Purdue School of Engineering and Technology, IUPUI. The IAC has won the awards twice. We have built the center that has the expertise and infrastructure for quality energy assessments to manufactures and commercial building owners and aligned our current research and teaching activities to the DOE’ training mission with programs to train the next generation of industrial energy efficiency experts, with theory and hands-on experience in conducting energy assessment for small and median manufacturing enterprises. We have made recommendations that have the potential to save about $20M annually. We also initiated research projects to meet DOE priorities, specifically in the areas of smart manufacturing and cybersecurity. On the energy assessment side, the Center has provided energy assessments to 144 qualified companies, primarily located in Indiana. On the training side, the center has trained students in various programs, such as the department’s Bachelor of Science (BS) programs in Mechanical Engineering (ME) and BS in Energy Engineering (EEN), both are ABET accredited engineering programs, as well as a graduate level Energy Management and Assessment certificate program. At the present, the center has trained 95 students, 43 or them received the DOE issued certificates. Research projects were developed within the center to advance energy efficiency related technologies, which provided excellent opportunities for our trainees. The center has also been building a professional network with utilities, Manufacturing Extension Partnership (MEP), government agencies, and manufacturing companies, to increase our client base and promote collaborations. The center received the 2019 Center of Excellence of the Year Award and three students received the “Outstanding Achievement in Energy Engineering by an IAC Student” awards in the past five years.

42 ENGINEERING↗

South Texas Industrial Assessment Center (Final Report)

The South Texas Industrial Assessment Center (ST-IAC) provides small to mid-size manufacturing companies and water treatment plants in the Rio Grande Valley of Texas, free energy assessments to help them reduce costs and stay competitive for sustainable development. The ST-IAC operates within the University of Texas Rio Grande Valley (UTRGV), and is the largest Hispanic-serving IAC in the U.S. Created in 2016, the ST-IAC, situated in the most economically disadvantaged region in the country, has been successful in training students and assessing local industries served by a predominantly Hispanic population. UTRGV, now the second largest Hispanic Serving Institution (HSI) of higher education in the U.S., has a student population of 32,000, of which 90% is Hispanic. While Covid-19 had a negative impact to our program during Budget Periods (BP) 4 and 5, the center still managed to provide opportunities for individuals, manufacturing and water industries in the local region. The program developed an energy engineering program in the region and further advanced national priorities. Those include resilience and sustainability of operations by implementing energy efficiency processes, renewable energy sources, decarbonization, battery storage, and cybersecurity in south Texas.

14 SOLAR ENERGY↗

DISTRIBUTION OF ION-EXCHANGEABLE RARE EARTH ELEMENTS AND CRITICAL MINERALS IN COAL-HOSTED CLAYS OF THE POWDER RIVER BASIN, WY

Increasing demand for a more robust domestic supply of rare earth elements (REE) and critical minerals (CM) has led to significant investigation into unconventional sources. Coal and coal byproducts from the Powder River Basin (PRB) of Wyoming are potential sources of REE but lack complete characterization of mineral hosts including ion-adsorption clays (IACs). IACs, which provide a substantial portion of the global REE supply, form when hydrated REE complexes are physiosorbed to negatively charged sites on clay surfaces. Typical IAC minerals include kaolinite, illite, and smectite. REE complexes are easily leached from IACs via ion exchange, making them economically attractive. However, research regarding the partitioning behaviors of strategic metals into PRB coal-hosted clays is limited. This project aims to quantify the modes of occurrence and distribution of REE and CM in clay minerals derived from PRB coals. Strategic metals investigated in this project have historic production or promising deposits within the PRB and/or high anticipated supply risk, and include: REE (lanthanides and Y), V, Ti, platinum group elements (PGE; Pt, Pd, Rh, Ru, Ir, Os), Al, Co, Ga, Zr, and W. Semi-quantitative compositional data from portable x-ray fluorescence spectroscopy (pXRF) on coal core from the PRB is consistent with the known correlation between REE and Al content, suggesting increased REE abundance will be found in clay-rich units. pXRF data also identifies elevated V, Ti, Co, and Zr correlated with Al. Preliminary x-ray diffraction (XRD) data indicates kaolinite, illite, and dickite are abundant minerals in overburden and clay-rich partings. Quantitative analysis via inductively coupled plasma mass spectrometry (ICP-MS) provides insights into REE and CM fractionation in coals as we compare trace metal occurrence to variations in mineralogy. Additionally, we apply scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS) data to correlate clay size and morphology to trace metal occurrence. Our findings supplement a broader effort to couple REE and CM extraction with existing domestic coal production and contribute to the fundamental understanding of adsorption processes that occur in low-temperature basin environments.

Stuart, Sophia↗

University of Dayton Industrial Assessment Center

The University of Dayton Industrial Assessment Center (UD-IAC) was established in 1981. Since then, the UD-IAC has completed 1,050 industrial energy assessments for the Department of Energy. The UD-IAC is committed to an ethic of continuous improvement, building upon the enormous knowledge and commitment it has developed over the past four decades and developing strong links to educational, research, and DOE initiatives. We feel lucky to be part of this great IAC program and pledge our best and most sustained efforts toward its continued success.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Industrial Assessment Center Technical Field Manager

The work to be performed involves managing Industrial Assessment Centers through a portfolio of activities. The core activities to be performed are in the general areas of; quality assurance of IAC operations, enhancement of the student IAC experience, program development for improving assessments and implementing smart manufacturing projects, program outreach to carry assessment successes beyond the program, and program integration with other DOE/manufacturing assistance programs. The IAC Technical Field Management Organization (FMO) works in close collaboration with DOE and provides technical management for the IAC program working under policy guidelines established by DOE.

42 ENGINEERING↗

Industrial Assessment Center Program

The work described in this report was performed under the direction of the Industrial Assessment Center (IAC) at University of Texas at Arlington. The IAC at The University of Texas at Arlington is managed by Rutgers University under agreement with the United States Department of Energy Office of Industrial Technology, which financially supports the program. The objective of the IAC is to identify, evaluate, and recommend, through analysis of an industrial plant’s operations, opportunities to conserve energy and prevent pollution, thereby reducing the associated costs. IAC team members visit and survey the plant. Based upon observations made in the plant, preventive/corrective actions are recommended. At all times we try to offer specific and quantitative recommendations of cost savings, energy conservation, and pollution prevention to the plants we serve.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Industrial Assessment Centers - Small Manufacturers Reduce Energy & Increase Productivity

Since 1976, the Industrial Assessment Centers (IACs), administered by the US Department of Energy, have supported small and medium-sized American manufacturers to reduce energy use and increase their productivity and competitiveness. The 24 IACs, located at premier engineering universities around the country (see below), send faculty and engineering students to local small and medium-sized manufacturers to provide no-cost assessments of energy use, process performance and waste and water flows. Under the direction of experienced professors, IAC engineering students analyze the manufacturer’s facilities, energy bills and energy, waste and water systems, including compressed air, motors/pumps, lighting, process heat and steam. The IACs then follow up with written energy-saving and productivity improvement recommendations, with estimates of related costs and payback periods.

Success, Alumni, Sign Up, Industrial, Assessment, ↗

Feature‐shared adaptive‐boost deep learning for invasiveness classification of pulmonary subsolid nodules in CT images

Purpose In clinical practice, invasiveness is an important reference indicator for differentiating the malignant degree of subsolid pulmonary nodules. These nodules can be classified as atypical adenomatous hyperplasia (AAH), adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), or invasive adenocarcinoma (IAC). The automatic determination of a nodule's invasiveness based on chest CT scans can guide treatment planning. However, it is challenging, owing to the insufficiency of training data and their interclass similarity and intraclass variation. To address these challenges, we propose a two‐stage deep learning strategy for this task: prior‐feature learning followed by adaptive‐boost deep learning. Methods The adaptive‐boost deep learning is proposed to train a strong classifier for invasiveness classification of subsolid nodules in chest CT images, using multiple 3D convolutional neural network (CNN)‐based weak classifiers. Because ensembles of multiple deep 3D CNN models have a huge number of parameters and require large computing resources along with more training and testing time, the prior‐feature learning is proposed to reduce the computations by sharing the CNN layers between all weak classifiers. Using this strategy, all weak classifiers can be integrated into a single network. Results Tenfold cross validation of binary classification was conducted on a total of 1357 nodules, including 765 noninvasive (AAH and AIS) and 592 invasive nodules (MIA and IAC). Ablation experimental results indicated that the proposed binary classifier achieved an accuracy of with an AUC of 81.3 . These results are superior compared to those achieved by three experienced chest imaging specialists who achieved an accuracy of , , and , respectively. About 200 additional nodules were also collected. These nodules covered 50 cases for each category (AAH, AIS, MIA, and IAC, respectively). Both binary and multiple classifications were performed on these data and the results demonstrated that the proposed method definitely achieves better performance than the performance achieved by nonensemble deep learning methods. Conclusions It can be concluded that the proposed adaptive‐boost deep learning can significantly improve the performance of invasiveness classification of pulmonary subsolid nodules in CT images, while the prior‐feature learning can significantly reduce the total size of deep models. The promising results on clinical data show that the trained models can be used as an effective lung cancer screening tool in hospitals. Moreover, the proposed strategy can be easily extended to other similar classification tasks in 3D medical images.

Wang, Jun↗

Cu-7Cr-0.1Ag Microcomposites Optimized for High Strength and High Condutivity

This paper (i) investigated how the microstructure, conductivity, and mechanical properties of Cu-7Cr-0.1Ag microcomposites were changed by cold drawing and subsequent heat treatment, and (ii) produced the Cu-7Cr-0.1Ag microcomposite with an optimum combination of strength and conductivity. The figure of merit Z (combining strength and conductivity) of the Cu-7Cr-0.1Ag microcomposite was larger than that of the microcomposite without silver for each heat treatment. The value of Z of the Cu-7Cr-0.1Ag microcomposite was a maximum after heat treatment for 1 h at 600 °C, indicating that this was the optimum intermediate heat treatment. The following combinations of conductivity, strength and ductility (measured as elongation to fracture) were obtained by the Cu-7Cr-0.1Ag microcomposite with η = 8: (i) 77.9% IACS (International Annealed Copper Standard), 920 MPa and 3.1%; (ii) 79.3% IACS, 880 MPa and 3.3%; and (iii) 79.9% IACS, 798 MPa and 3.5%. These values for the Cu-7Cr-0.1Ag microcomposite were larger than those of the Cu-7Cr microcomposite.

36 MATERIALS SCIENCE↗

Positron program at the Idaho Accelerator Center

Positron physics is an important part of the research activities at the Idaho Accelerator Center (IAC). With positron annihilation spectroscopy, maps of nanodefects in materials have been obtained. For this purpose, positrons are generated by radioactive decay, photoactivation, or pair production. Preliminary tests of positron sources in the MeV range based on electron linacs have also been carried out at the IAC, and an expansion of this program is planned. A similar positron beam at Jefferson Lab would greatly improve our knowledge of the inner structure of the proton. In this paper, research with positrons at the IAC is reviewed. After a description of the Center's facilities, results from positron annihilation spectroscopy are discussed, together with future plans for testing a prototype positron source for CEBAF.

43 PARTICLE ACCELERATORS↗