Search NASA⌕ Search

SEARCH · Search NASA

Results for “ICCING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Reliability of a Test Battery Designed for Quickly and Safely Assessing Diverse Indices of Neuromuscular Function

Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National

Spiering, Barry A.↗

Reader agreement and accuracy of ultrasound features for hepatic steatosis

Purpose: The purpose of the study is to assess the reader agreement and accuracy of eight ultrasound imaging features for classifying hepatic steatosis in adults with known or suspected hepatic steatosis. Methods: This was an IRB-approved, HIPAA-compliant prospective study of adult patients with known or suspected hepatic steatosis. All patients signed written informed consent. Ultrasound images (Siemens S3000, 6C1HD, and 4C1 transducers) were acquired by experienced sonographers following a standard protocol. Eight readers independently graded eight features and their overall impression of hepatic steatosis on ordinal scales using an electronic case report form. Duplicated images from the 6C1HD transducer were read twice to assess intra-reader agreement. Intra-reader, inter-transducer, and inter-reader agreement were assessed using intraclass correlation coefficients (ICC). Features with the highest intra-reader agreement were selected as predictors for dichotomized histological steatosis using Classification and Regression Tree (CART) analysis, and the accuracy of the decision rule was compared to the accuracy of the radiologists’ overall impression. Results: 45 patients (18 males, 27 females; mean age 56 ± 12 years) scanned from September 2015 to July 2016 were included. Mean intra-reader ICCs ranged from 0.430 to 0.777, inter-transducer ICCs ranged from 0.228 to 0.640, and inter-reader ICCs ranged from 0.014 to 0.561. The CART decision rule selected only large hepatic vein blurring and achieved similar accuracy to the overall impression (74% to 75% and 68% to 72%, respectively). Conclusions: Large hepatic vein blurring, liver–kidney contrast, and overall impression provided the highest reader agreement. Large hepatic vein blurring may provide the highest classification accuracy for dichotomized grading of hepatic steatosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inter-reader agreement of magnetic resonance imaging proton density fat fraction and its longitudinal change in a clinical trial of adults with nonalcoholic steatohepatitis

Purpose: To determine the inter-reader agreement of magnetic resonance imaging proton density fat fraction (PDFF) and its longitudinal change in a clinical trial of adults with nonalcoholic steatohepatitis (NASH). Study type: We performed a secondary analysis of a placebo-controlled randomized clinical trial of a bile acid sequestrant in 45 adults with NASH. A six-echo spoiled gradient-recalled-echo magnitude-based fat quantification technique was performed at 3 T. Three independent readers measured MRI-PDFF by placing one primary and two additional regions of interest (ROIs) in each segment at both time points. Cross-sectional agreement between the three readers was evaluated using intra-class correlation coefficients (ICCs) and coefficients of variation (CV). Additionally, we used Bland–Altman analyses to examine pairwise agreement between the three readers at baseline, end of treatment (EOT), and for longitudinal change. Results: Using all ROIs by all readers, mean PDFF at baseline, at EOT, and mean change in PDFF was 16.1%, 16.0%, and 0.07%, respectively. The 27-ROI PDFF measurements had 0.998 ICC and 1.8% CV at baseline, 0.998 ICC and 1.8% CV at EOT, and 0.997 ICC for longitudinal change. The 9-ROI PDFF measurements had corresponding values of 0.997 and 2.6%, 0.996 and 2.4%, and 0.994. Using 27 ROIs, the magnitude of the bias between readers for whole-liver PDFF measurement ranged from 0.03% to 0.06% points at baseline, 0.01% to 0.07% points at EOT, and 0.01% to 0.02% points for longitudinal change. Conclusion: Inter-reader agreement for measuring whole-liver PDFF and its longitudinal change is high. 9-ROI measurements have only slightly lower agreement than 27-ROI measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Opportunistic bone density screening for the abdominal radiologist using colored CT images: a pilot retrospective study

Purpose: The purpose of the study was to develop an accurate and reproducible method for detecting low spinal bone density on abdominal CT images. Methods: For this IRB-approved HIPAA-compliant single-center retrospective study, nonenhanced CT images of the lower abdomen were obtained in 631 African-American participants. Mean attenuation of L3/L4 was associated with quantitative CT bone density (QCT) in a randomly selected training cohort (N = 511), and receiver operating characteristics analysis was used to identify the optimal mean attenuation threshold for differentiating normal from low bone density. Custom image processing software was used to generate grayscale and colored CT images of the midline spine, with green for normal and red for low bone density. Five radiologists independently assessed bone density at L3/L4 in a validation cohort (N = 120) using various methods: QCT, visual assessment of sagittal grayscale images (Grayscale), quantitative measurement of mean attenuation on a midline sagittal image (Attenuation), and visual assessment of a midline sagittal colored image (Color). Accuracy was calculated using the average QCT bone density as a reference standard. Inter-observer agreement was assessed using intraclass correlation coefficient (ICC). Results: The optimal mean attenuation threshold for differentiating normal from low bone density at L3/L4 was 145 Hounsfield Units. The average accuracy of Grayscale, Attenuation, and Color methods was 58, 87, and 91% (p < 0.001), respectively. Inter-observer agreement was poor for Grayscale (ICC: 0.20; 95% CI 0.12, 0.28) and excellent for both Attenuation (ICC: 0.85; 95% CI 0.73, 0.91) and Color methods (ICC: 0.87; 95% CI 0.83, 0.90). Conclusion: Detection of low spinal bone density using colored abdominal CT images was highly accurate and reproducible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Hepatic Yttrium-90 Radioembolization in Patients with Unresectable Intrahepatic Cholangiocarcinoma: Factors Associated with Prolonged Survival

Introduction: In unresectable intrahepatic cholangiocarcinoma (ICC), systemic chemotherapy often is viewed as the only option, although efficacy is limited. Radioembolization (RE) using yttrium-90 ({sup 90}Y) microspheres is an accepted therapy for patients with hepatocellular-carcinoma or metastatic liver tumors. However, there are limited data on the value of RE in patients with ICC and few data on factors influencing prognosis. The purpose of our retrospective analysis was to establish which factors influenced time-to-progression (TTP) and overall survival (OS). Methods: Patients with unresectable ICC were treated with {sup 90}Y resin-microspheres and assessed at 3-monthly intervals. Radiologic response was evaluated by using Response Criteria in Solid Tumors (RECIST). Baseline characteristics, biochemical/clinical toxicities, and response were examined for impact on TTP and OS. Results: Thirty-four treatments were administered to 33 patients without major complications. By RECIST, 12 patients had a partial response, 17 had stable disease, and 5 had progressive disease after 3 months. The median OS was 22 months posttreatment and 43.7 months postdiagnosis. Median TTP was 9.8 months. Survival and TTP were significantly prolonged in patients with ECOG 0 (vs. ECOG 1 or 2; median OS: 29.4, 10, and 5.1 months; TTP: 17.5, 6.9, and 2.4 months), tumor burden {<=}25% (OS: 26.7 vs. 6 months; TTP: 17.5 vs. 2.3 months), or tumor response (PR or SD vs. PD; OS: 35.5, 17.7 vs. 5.7 months; TTP: 31.9, 9.8 vs. 2.5 months), respectively (P < 0.001). Conclusions: Radioembolization is an effective and safe option for patients with unresectable ICC. Predictors for prolonged survival are performance status, tumor burden, and RECIST response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Radiofrequency Ablation of Unresectable Intrahepatic Cholangiocarcinomas: A Retrospective Study

Purpose: To evaluate treatment effects, complications, and outcome of percutaneous stereotactic radiofrequency ablation (SRFA) of intrahepatic cholangiocarcinoma (ICC). Patients and Methods: Eleven consecutive patients (nine men and two women) with a total of 36 inoperable ICCs (18 initial lesions, 16 lesions newly detected during follow-up, and two local recurrences) underwent SRFA between December 2004 and June 2010. Two different radiofrequency ablation (RFA) devices with internally cooled electrodes were used. Tumor diameters ranged from 0.5 to 10 cm (median 3.0 cm). A total of 23 SRFA sessions were performed. The efficacy of SRFA was evaluated by contrast-enhanced computed tomography or magnetic resonance imaging 1 month after treatment and then every 3 months. Results: Primary technical effectiveness rate was 92%. Further follow-up every 3 months revealed three local recurrences (8%), two of which were successfully retreated, resulting in a secondary technical effectiveness rate of 98%. After a total of 23 RFA sessions, three major complications occurred (13%) that could be managed interventionally. Mean follow-up time was 35 months (range 12-81 months). One- and 3-year overall survival rates were 91 and 71%, respectively. The median overall survival was 60 months (according to the life table method). Eight (73%) of 11 patients were still alive at the end of follow-up. Conclusion: SRFA is effective in the treatment of unresectable ICC even if the tumor is large and located close to major vessels. SRFA shows a survival benefit compared to other palliative treatment options and may also be considered as the first-line local treatment of ICCs in selected patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bayesian optimal experimental design for constitutive model calibration

Computational simulation is increasingly relied upon for high/consequence engineering decisions, which necessitates a high confidence in the calibration of and predictions from complex material models. However, the calibration and validation of material models is often a discrete, multi-stage process that is decoupled from material characterization activities, which means the data collected does not always align with the data that is needed. To address this issue, an integrated workflow for delivering an enhanced characterization and calibration procedure—Interlaced Characterization and Calibration (ICC)—is introduced and demonstrated. Further, this framework leverages Bayesian optimal experimental design (BOED), which creates a line of communication between model calibration needs and data collection capabilities in order to optimize the information content gathered from the experiments for model calibration. Eventually, the ICC framework will be used in quasi real-time to actively control experiments of complex specimens for the calibration of a high-fidelity material model. This work presents the critical first piece of algorithm development and a demonstration in determining the optimal load path of a cruciform specimen with simulated data. Calibration results, obtained via Bayesian inference, from the integrated ICC approach are compared to calibrations performed by choosing the load path a priori based on human intuition, as is traditionally done. The calibration results are communicated through parameter uncertainties which are propagated to the model output space (i.e. stress–strain). In these exemplar problems, data generated within the ICC framework resulted in calibrated model parameters with reduced measures of uncertainty compared to the traditional approaches.

42 ENGINEERING↗

Reproducibility of 'Intelligent' Contouring of Gross Tumor Volume in Non-Small-Cell Lung Cancer on PET/CT Images Using a Standardized Visual Method

Purpose: Positron emission tomography/computed tomography (PET/CT) is increasingly used for delineating gross tumor volume (GTV) in non-small-cell lung cancer (NSCLC). The methodology for contouring tumor margins remains controversial. We developed a rigorous visual protocol for contouring GTV that uses all available clinical information and studied its reproducibility in patients from a prospective PET/CT planning trial. Methods and Materials: Planning PET/CT scans from 6 consecutive patients were selected. Six 'observers' (two radiation oncologists, two nuclear medicine physicians, and two radiologists) contoured GTVs for each patient using a predefined protocol and subsequently recontoured 2 patients. For the estimated GTVs and axial distances, least-squares means for each observer and for each case were calculated and compared, using the F test and pairwise t-tests. In five cases, tumor margins were also autocontoured using standardized uptake value (SUV) cutoffs of 2.5 and 3.5 and 40% SUV{sub max}. Results: The magnitude of variation between observers was small relative to the mean (coefficient of variation [CV] = 3%), and the total variation (intraclass correlation coefficient [ICC] = 3%). For estimation of superior/inferior (SI), left/right (LR), and anterior/posterior (AP) borders of the GTV, differences between observers were also small (AP, CV = 2%, ICC = 0.4%; LR, CV = 6%, ICC = 2%; SI, CV 4%, ICC = 2%). GTVs autocontoured generated using SUV 2.5, 3.5, and 40% SUV{sub max} differed widely in each case. An SUV contour of 2.5 was most closely correlated with the mean GTV defined by the human observers. Conclusions: Observer variation contributed little to total variation in the GTV and axial distances. A visual contouring protocol gave reproducible results for contouring GTV in NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional tori and Arnold tongues

This study analyzes an Arnold resonance web, which includes complicated quasi-periodic bifurcations, by conducting a Lyapunov analysis for a coupled delayed logistic map. The map can exhibit a two-dimensional invariant torus (IT), which corresponds to a three-dimensional torus in vector fields. Numerous one-dimensional invariant closed curves (ICCs), which correspond to two-dimensional tori in vector fields, exist in a very complicated but reasonable manner inside an IT-generating region. Periodic solutions emerge at the intersections of two different thin ICC-generating regions, which we call ICC-Arnold tongues, because all three independent-frequency components of the IT become rational at the intersections. Additionally, we observe a significant bifurcation structure where conventional Arnold tongues transit to ICC-Arnold tongues through a Neimark-Sacker bifurcation in the neighborhood of a quasi-periodic Hopf bifurcation (or a quasi-periodic Neimark-Sacker bifurcation) boundary.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EDITORIAL HPJ SPECIAL ISSUE INTRODUCTION

Radioecology is the study of the fate and transport and potential effects of radionuclides and associated contaminants in the environment. In short, it is the science that describes the fundamental connection between environmental health and human health risks. As such, radioecology can and has provided the credible, consistent and defensible basis for the successful and cost-effective environmental cleanup and closure of nuclear production and waste sites. In addition, radioecology also provides the technical basis for making timely and reliable decisions on cleanup in the aftermath of nuclear incidents such as Chernobyl and Fukushima. The 1986 Chernobyl Nuclear Power Plant (ChNPP) accident resulted in catastrophic health, social, and economic consequences in many countries, predominantly, Ukraine, Belarus, and Russia. The extent of radioactive contamination, levels and forms of contamination, and diversity of the ecosystems affected by the accident did not have any precedent and provided unique opportunities for environmental scientists around the world. Following the natural course of their development, populations of species and their communities found themselves in conditions of chronic radiation exposure that exceeded the natural background by factors of hundreds and thousands. Anything similar would have been extremely difficult if not impossible to recreate in a scientific laboratory. Consequently, since the first few years after the accident, many teams of scientists have visited the Chernobyl Exclusion Zone (ChEZ). The knowledge gained by studying the consequences of this accident has tremendous importance. The concept of an international research and technical center to address the problems involving nuclear and radiological accidents became a reality with the establishment of the International Chernobyl Center (ICC). In May 1995, the US and Ukraine signed a Protocol of Intent on establishment of the ICC, and the government of Ukraine appealed to the international scientific community to support ICC and join its activities (Chernobyl Center 2006). In December 1995, a memorandum of understanding (MOU) on the ChNPP closure was signed by the government of Ukraine, all of the G7 governments, and the European Commission. The ICC foundation was considered critical to ensure the safe decommissioning of the ChNPP reactor units and improvement of the safety of the Chernobyl Containment Shelter. On the 10th anniversary of the Chernobyl accident (26 April 1996), Mr. Viktor Yushchenko, the President of Ukraine, issued a decree to establish the Chernobyl Center for Nuclear Safety, Radioactive Waste and Radioecology (Chernobyl Center). On the same day, a MOU involving the US participation in Chernobyl Center activities was signed by the US and Ukraine (Chernobyl Center 2006). In July 1998, the US and Ukraine signed an agreement to establish the International Radioecology Laboratory (IRL) as part of the Chernobyl Center. The creation of IRL was a logical continuation of previous programs to conduct scientific research in radioecology and provide Ukraine and the rest of the world with the necessary infrastructure and scientific basis to conduct research in radioecology, radiobiology, dosimetry, and environmental protection in the ChEZ (Chernobyl Center 2006). A recent collaborative effort with IRL has been implemented through a project titled 'Long-term impacts from radiation/contamination within the Chernobyl Exclusion Zone' (Farfan et al. 2008; Gerdes et al. 2009; Marra et al. 2010). This collaboration had the following objectives: (1) Assess the long-term impacts to the environment from radiation exposure within the ChEZ; (2) Provide information on remediation guidelines and ecological risk assessment within radioactively contaminated territories based on the results of long-term field monitoring, analytical measurements, and numerical modeling of soils and groundwater radioactive contamination; and (3) Recommend the development and testing of effective cleanup technologies to reduce environmental and health risks. Based on this work, a large amount of data are now available for publication, some of which are presented in this Special Issue of the Health Physics Journal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-D-207B-01: Radiomics Feature Reproducibility From Repeat CT Scans of Patients with Rectal Cancer

Purpose: To evaluate the reproducibility of radiomics features by repeating computed tomographic (CT) scans in rectal cancer. To choose stable radiomics features for rectal cancer. Methods: 40 rectal cancer patients were enrolled in this study, each of whom underwent two CT scans within average 8.7 days (5 days to 17 days), before any treatment was delivered. The rectal gross tumor volume (GTV) was distinguished and segmented by an experienced oncologist in both CTs. Totally, more than 2000 radiomics features were defined in this study, which were divided into four groups (I: GLCM, II: GLRLM III: Wavelet GLCM and IV: Wavelet GLRLM). For each group, five types of features were extracted (Max slice: features from the largest slice of target images, Max value: features from all slices of target images and choose the maximum value, Min value: minimum value of features for all slices, Average value: average value of features for all slices, Matrix sum: all slices of target images translate into GLCM and GLRLM matrices and superpose all matrices, then extract features from the superposed matrix). Meanwhile a LOG (Laplace of Gauss) filter with different parameters was applied to these images. Concordance correlation coefficients (CCC) and inter-class correlation coefficients (ICC) were calculated to assess the reproducibility. Results: 403 radiomics features were extracted from each type of patients’ medical images. Features of average type are the most reproducible. Different filters have little effect for radiomics features. For the average type features, 253 out of 403 features (62.8%) showed high reproducibility (ICC≥0.8), 133 out of 403 features (33.0%) showed medium reproducibility (0.8≥ICC≥0.5) and 17 out of 403 features (4.2%) showed low reproducibility (ICC≥0.5). Conclusion: The average type radiomics features are the most stable features in rectal cancer. Further analysis of these features of rectal cancer can be warranted for treatment monitoring and prognosis prediction.

60 APPLIED LIFE SCIENCES↗

Day-to-day reliability of basal heart rate and short-term and ultra short-term heart rate variability assessment by the Equivital eq02+ LifeMonitor in US Army soldiers

Introduction The present study determined the (1) day-to-day reliability of basal heart rate (HR) and HR variability (HRV) measured by the Equivital eq02+ LifeMonitor and (2) agreement of ultra short-term HRV compared with short-term HRV. Methods Twenty-three active-duty US Army Soldiers (5 females, 18 males) completed two experimental visits separated by >48 hours with restrictions consistent with basal monitoring (eg, exercise, dietary), with measurements after supine rest at minutes 20–21 (ultra short-term) and minutes 20–25 (short-term). HRV was assessed as the SD of R–R intervals (SDNN) and the square root of the mean squared differences between consecutive R–R intervals (RMSSD). Results The day-to-day reliability (intraclass correlation coefficient (ICC)) using linear-mixed model approach was good for HR (0.849, 95% CI: 0.689 to 0.933) and RMSSD (ICC: 0.823, 95% CI: 0.623 to 0.920). SDNN had moderate day-to-day reliability with greater variation (ICC: 0.689, 95% CI: 0.428 to 0.858). The reliability of RMSSD was slightly improved when considering the effect of respiration (ICC: 0.821, 95% CI: 0.672 to 0.944). There was no bias for HR measured for 1 min versus 5 min (p=0.511). For 1 min measurements versus 5 min, there was a very modest mean bias of −4 ms for SDNN and −1 ms for RMSSD (p≤0.023). Conclusion When preceded by a 20 min stabilisation period using restrictions consistent with basal monitoring and measuring respiration, military personnel can rely on the eq02+ for basal HR and RMSSD monitoring but should be more cautious using SDNN. These data also support using ultra short-term measurements when following these procedures.

General & Internal Medicine↗

Illinois Distributed Generation Rebate - Preliminary Stakeholder Input and Calculation Considerations

What is the value of distributed generation to the distribution system and how do we assign that value to a rebate? This white paper is an update to Illinois Distributed Generation Rebate Calculation Considerations (PNNL-27569) and provides a preliminary look at potential distributed generation valuation methodologies and compensation options for Illinois by taking into consideration data needs and availability, stakeholder comments, and Illinois Public Utilities Act language. Pacific Northwest National Laboratory (PNNL) is supporting the Illinois Commerce Commission (ICC) with initial stakeholder engagement to advance the conversation around distributed generation valuation in Illinois. PNNL’s educational support will help set the stage for a productive formal process as the ICC will be called upon, in relatively short order, to start formal distributed generation valuation proceedings in response to Illinois Public Act 99-0906, also known as the Future Energy Jobs Act (FEJA), and codified in Illinois Public Utilities Act Section 16-107.6. This white paper does not represent the ICC’s formal investigation of distributed generation rebate valuation and is not intended to characterize or prejudge any decisions on behalf of the ICC.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CO2 Capture from Biofuels Production and Storage into the Mt Simon Sandstone

Advanced carbon capture and storage (CCS) technologies offer significant potential for reducing anthropogenic carbon dioxide (CO2) emissions, while minimizing the cost of employing these technologies. Under the Industrial Carbon Capture and Storage (ICCS) Program, the U.S. Department of Energy (DOE) collaborated with industry in cost-sharing arrangements to demonstrate technologies that captured CO2 emissions from industrial sources and either stored or beneficially re-use them. The technologies included in the ICCS program progressed beyond the research and development stage to a scale that can be deployed into commercial practice within the industry. The Illinois Industrial Carbon Capture and Storage (IL-ICCS) project sought to demonstrate the ability of the Mt. Simon Sandstone to accept and retain industrial-scale volumes of carbon dioxide (CO2) from an anthropogenic source for permanent geologic sequestration. The project was a collaboration of Archer Daniels Midland (ADM) Company, the Illinois State Geological Survey (ISGS), Schlumberger Carbon Services (SCS), and Richland Community College (RCC), and had average annual injection rate of between 1,500 and 2,400 metric tons per day (MTPD) or 0.5 to 0.7 million metric tons (MMT) annually. The project site is in Decatur, Illinois on the property of ADM and RCC (Fig 1) and is directly adjacent to the Illinois Basin – Decatur Project (IBDP), a large scale pilot project of the Midwest Geological Sequestration Consortium (MGSC), which collected and injected CO2 from the ADM fuel ethanol production unit, where high purity biogenic CO2 is produced during the anaerobic fermentation of sugars to alcohol. The IL-ICCS project had an operational period of approximately six (6) years, in which 3.5 MMT of CO2 was captured, compressed, injected, and permanently stored in the Mt Simon Sandstone.

01 COAL, LIGNITE, AND PEAT↗

Integrated Communication and Control Systems. III - Nonidentical sensor and controller sampling

Networking in Integrated Communication and Control Systems (ICCS) introduces randomly varying delays which degrade the system dynamic performance and are a source of potential instability. In Part I of this sequence of papers, a discrete-time, finite-dimensional model of the delayed control system for analysis and design of ICCS was developed where the sensor and controller have identical sampling rates. In Part II, two alternate approaches for ICCS design, namely, identical and nonidentical sampling rates for sensor and controller were proposed. This Part III presents extended modeling of ICCS for nonidentical sensor and controller sampling rates. This model is also suitable for analyzing tracking problems, i.e., control systems with time-dependent reference inputs.

Liou, Luen-Woei↗

An intelligent automated command and control system for spacecraft mission operations

The Intelligent Command and Control (ICC) System research project is intended to provide the technology base necessary for producing an intelligent automated command and control (C&C) system capable of performing all the ground control C&C functions currently performed by Mission Operations Center (MOC) project Flight Operations Team (FOT). The ICC research accomplishments to date, details of the ICC, and the planned outcome of the ICC research, mentioned above, are discussed in detail.

Stoffel, A. William↗

Reliability of Maximal Strength Testing in Novice Weightlifters

The one repetition maximum (1RM) is a criterion measure of muscle strength. However, the reliability of 1RM testing in novice subjects has received little attention. Understanding this information is crucial to accurately interpret changes in muscle strength. To evaluate the test-retest reliability of a squat (SQ), heel raise (HR), and deadlift (DL) 1RM in novice subjects. Twenty healthy males (31 plus or minus 5 y, 179.1 plus or minus 6.1 cm, 81.4 plus or minus 10.6 kg) with no weight training experience in the previous six months participated in four 1RM testing sessions, with each session separated by 5-7 days. SQ and HR 1RM were conducted using a smith machine; DL 1RM was assessed using free weights. Session 1 was considered a familiarization and was not included in the statistical analyses. Repeated measures analysis of variance with Tukey fs post-hoc tests were used to detect between-session differences in 1RM (p.0.05). Test-retest reliability was evaluated by intraclass correlation coefficients (ICC). During Session 2, the SQ and DL 1RM (SQ: 90.2 }4.3, DL: 75.9 }3.3 kg) were less than Session 3 (SQ: 95.3 }4.1, DL: 81.5 plus or minus 3.5 kg) and Session 4 (SQ: 96.6 }4.0, DL: 82.4 }3.9 kg), but there were no differences between Session 3 and Session 4. HR 1RM measured during Session 2 (150.1 }3.7 kg) and Session 3 (152.5 }3.9 kg) were not different from one another, but both were less than Session 4 (157.5 }3.8 kg). The reliability (ICC) of 1RM measures for Sessions 2-4 were 0.88, 0.83, and 0.87, for SQ, HR, and DL, respectively. When considering only Sessions 3 and 4, the reliability was 0.93, 0.91, and 0.86 for SQ, HR, and DL, respectively. One familiarization session and 2 test sessions (for SQ and DL) were required to obtain excellent reliability (ICC greater than or equal to 0.90) in 1RM values with novice subjects. We were unable to attain this level of reliability following 3 HR testing sessions therefore additional sessions may be required to obtain an ICC of greater than or equal to 0.90. Future resistive exercise studies should consider the reliability of specific measures to ensure that changes in strength with training are attributable to training and not learning effects associated with 1RM testing.

Loehr, James A.↗

Radiation detector device for rejecting and excluding incomplete charge collection events

A radiation detector device is provided that is capable of distinguishing between full charge collection (FCC) events and incomplete charge collection (ICC) events based upon a correlation value comparison algorithm that compares correlation values calculated for individually sensed radiation detection events with a calibrated FCC event correlation function. The calibrated FCC event correlation function serves as a reference curve utilized by a correlation value comparison algorithm to determine whether a sensed radiation detection event fits the profile of the FCC event correlation function within the noise tolerances of the radiation detector device. If the radiation detection event is determined to be an ICC event, then the spectrum for the ICC event is rejected and excluded from inclusion in the radiation detector device spectral analyses. The radiation detector device also can calculate a performance factor to determine the efficacy of distinguishing between FCC and ICC events.

36 MATERIALS SCIENCE↗