Anti-Icing Formulas Prevent Train Delays

In the winter of 2009, Washington, DC, workers faced the prospect of a difficult commute due to record-setting snowfalls. But thousands of the city's Metrorail riders found the public transportation system fully functional, thanks in part to a NASA technology invented years before. Just like trains, an airplane must be snow- and ice-free to ensure safe travel. Traditionally, fluids containing a compound called ethylene glycol have been used to inhibit ice on planes. In 1992, however, the US Air Force banned its purchase of this ingredient due to toxicity concerns. According to the Centers for Disease Control, exposure to large amounts of ethylene glycol through air or water can damage the kidneys, nervous system, lungs, and heart. Urine samples from airport deicing workers have contained traces of the substance. At the time of the Air Force s ban, Robert Lockyer was working at NASA s Ames Research Center in the Advanced Composites Model Development Branch, where he says "we decided to pick up the gauntlet and began researching existing fluid compositions and the processes used in deicing aircraft." Along with Lockyer, in 1997 Ames researchers Leonard Haslim and John Zuk devised a nontoxic, biodegradable, and cost effective substitute for ethylene glycol. When applied to a dry surface before a snow or ice event, the solution prevented ice from forming a bond with the surface. This made it easy to wipe away any accumulation.

Source record↗

"We Freeze to Please": A History of NASA's Icing Research Tunnel and the Quest for Flight Safety

The formation of ice on wings and other control surfaces of airplanes is one of the oldest and most vexing problems that aircraft engineers and scientists continue to face. While no easy, comprehensive answers exist, the staff at NASAs Icing Research Tunnel (IRT) at the Glenn Research Center in Cleveland has done pioneering work to make flight safer for experimental, commercial, and military customers. The National Advisory Committee for Aeronautics (NACA) initiated government research on aircraft icing in the 1930s at its Langley facility in Virginia. Icing research shifted to the NACA's Cleveland facility in the 1940s. Initially there was little focus on icing at either location, as these facilities were more concerned with aerodynamics and engine development. With several high-profile fatal crashes of air mail carriers, however, the NACA soon realized the need for a leading research facility devoted to icing prevention and removal. The IRT began operation in 1944 and, despite renovations and periodic attempts to shut it down, has continued to function productively for almost 60 years. In part because icing has proved so problematic over time, IRT researchers have been unusually open-minded in experimenting with a wide variety of substances, devices, and techniques. Early icing prevention experiments involved grease, pumping hot engine exhaust onto the wings, glycerin soap, mechanical and inflatable "boots," and even corn syrup. The IRT staff also looked abroad for ideas and later tried a German and Soviet technique of electromagnetism, to no avail. More recently, European polymer fluids have been more promising. The IRT even periodically had "amateur nights" in which a dentist's coating for children's teeth proved unequal to the demands of super-cooled water droplets blown at 100 miles per hour. Despite many research dead-ends, IRT researchers have achieved great success over the years. They have developed important computer models, such as the LEWICE software, and made significant contributions to prevent ice buildup on turbine-powered commercial aircraft, helicopters, and military planes.

Leary, William M.↗

An Investigation of the Prevention of Ice on the Airplane Windshield

An investigation of three methods for the prevention and the removal of ice on an airplane windshield has been completed. The methods were: electric heating; hot-air heating; and an alcohol-dispensing, rotating wiper blade. The results showed that vision through the airplane windshield could be maintained during severe icing conditions by the use of heat. When put in operation prior to the formation of ice on the windshield the rotating wiper blade prevented the formation of ice. A combination of heated air and a rotating wiper blade would appear to protect against formation of ice on the windshield exterior, to prevent frost on the interior and to provide for the removal of rainfall.

Rodert, Lewis A↗

An Investigation of the Prevention of Ice on the Airplane Windshield

An investigation has been completed on several methods for the prevention and removal of ice on an airplane windshield. Tests were made on the use of electric heating, hot-air heating, and an alcohol-dispensing, rotating wiper blade. The results showed that vision through the airplane windshield could be maintained during severe icing conditions by the use of heat. When put in operation prior to the formation of ice on the windshield, the rotating wiper blade prevented the formation of ice. A combination system that employs the use of heated air and a rotating wiper blade would appear to give protection against the formation of ice on the windshield exterior, prevent frost on the interior, and provide for the removal of rainfall.

Rodert, Lewis A.↗

A Preliminary Study of the Prevention of Ice on Aircraft by the Use of Engine-exhaust Heat

An investigation was made in the N.A.C.A. ice tunnel at air temperatures from 20 degrees to 28 degrees Fahrenheit and at a velocity of 80 miles per hour to determine whether ice formations on a model wing could be prevented by the use of the heat from the engine-exhaust gas. Various spanwise duct systems were tested in a 6-foot-chord N.A.C.A. 23012 wing model. The formation of ice over the entire wing chord was prevented by the direct heating of the forward 10 percent of the wing by hot air, which was passed through leading-edge ducts. Under dry conditions, enough heat to maintain the temperature of the forward 10 percent of the wing at about 200 degrees Fahrenheit above that of the ambient air was required for the prevention of ice formation. The air temperature in the ducts that was necessary to produce these skin temperatures varied from 360 degrees to 834 degrees Fahrenheit; the corresponding air velocities in the duct were 152 and 45 feet per second. Ice formations at the leading edge were locally prevented by air that passed over the interior of the wing surface at a velocity of 30 feet per second and a temperature of 122 degrees Fahrenheit.

Rodert, Lewis A↗

New Fluid Prevents Railway Ice

Through a licensing agreement between NASA's Ames Research Center and Midwest Industrial Supply, Inc. (MIS), two MIS products have been enhanced with NASA's anti-icing fluid technology. MIS offers the new fluid in two commercial products, the Zero Gravity(TM) Third Rail Anti-Icer/Deicer and the Ice Free Switch(R). Using NASA's fluid technology, these products form a protective-coating barrier that prevents the buildup of ice and snow. Applying the fluid to the railway components prior to ice or snowstorm works as an anti-icing fluid, remaining in place to melt precipitation as it hits the surface. It also functions as a deicing fluid. If applied to an already frozen switch or rail, it will quickly melt the ice, free the frozen parts, and then remain in place to prevent refreezing. Additional benefits include the ability to cling to vertical rail surfaces and resist the effects of rain and wind. With the Ice Free Switch, it takes only five minutes to treat the switch by spraying, brushing, or pouring on the product. Ice Free Switch requires as little as one gallon per switch whereas other deicing fluids require five to ten gallons of liquid to effectively melt ice. Zero Gravity serves the same anti-icing/deicing purposes but applies fluid to the third rail through a system that is easily installed onto mass transit cars. A tank of fluid and a dispensing system are placed underneath the train car and the fluid is applied as the train runs its route.

Source record↗

The Prevention of Ice Formation on Gasoline Tank Vents

This investigation was conducted in the refrigerated wind tunnel at the Langley Memorial Aeronautical Laboratory, Langley Field, Va., to determine a suitable method for preventing the formation of ice on the vents of airplane gasoline tanks. Tests were made on a variety of vent forms arranged in a number of different orientations relative to the direction of the air stream. Both the size of the tube and its orientation were found to be of great importance. Small tubes, under equal circumstances, were found to freeze over far more rapidly than large ones. Tubes pointing downstream, or shielded in other ways, appear to be perfectly immune against this hazard. A tube 3/4 inch in diameter with the opening pointing downstream is finally recommended as being the safest choice of gas tank vent.

Theodorsen, Theodore↗

Aerodynamic heating and the deflection of drops by an obstacle in an air stream in relation to aircraft icing

Two topics of interest to persons attempting to apply the heat method of preventing ice formation on aircraft are considered. Surfaces moving through air at high speed are shown, both theoretically and experimentally, to be subject to important aerodynamic heating effects that will materially reduce the heat required to prevent ice. Numerical calculations of the path of water drops in an air stream around a circular cylinder are given. From these calculations, information is obtained on the percentage of the swept area cleared of drops.

Kantrowitz, Arthur↗

Expandable Purge Chambers Would Protect Cryogenic Fittings

Expandable ice-prevention and cleanliness-preservation (EIP-CP) chambers have been proposed to prevent the accumulation of ice or airborne particles on quick-disconnect (QD) fittings, or on ducts or tubes that contain cryogenic fluids. In the original application for which the EIP-CP chambers were conceived, there is a requirement to be able to disconnect and reconnect the QD fittings in rapid succession. If ice were to form on the fittings by condensation and freezing of airborne water vapor on the cold fitting surfaces, the ice could interfere with proper mating of the fittings, making it necessary to wait an unacceptably long time for the ice to thaw before attempting reconnection. By keeping water vapor away from the cold fitting surfaces, the EIP-CP chambers would prevent accumulation of ice, preserving the ability to reconnect as soon as required. Basically, the role of an EIP-CP chamber would be to serve as an enclosure for a flow of dry nitrogen gas that would keep ambient air away from QD cryogenic fittings. An EIP-CP chamber would be an inflatable device made of a fabriclike material. The chamber would be attached to an umbilical plate holding a cryogenic QD fitting.

Townsend, Ivan I., III↗

A Flight Investigation of Exhaust-Heat De-Icing, Special Report

The National Advisory Committee for Aeronautics has conducted exhaust-heat de-icing tests inflight t o provide data needed in the application of this method of ice prevention. Thc capacity to extract heat from the exhaust gas for de-icing purposes, the quantity of heat required, and other factors were examined. The results indicate that a wing-heating system employing a spanwise exhaust tube within the leading edge of the wing will make available for de-icing purposes between 30 and 35 percent of the exhaust-gas heat. Data are given by which the heat required for ice prevention can be calculated. Sample calculations have been made, on a basis of existing engine power over wing area ratios, to show that sufficient heating can be obtained for ice protection on modern transport airplanes,

Rodert, Lewis A.↗

Computational Modeling Approaches to Multiscale Design of Icephobic Surfaces

To aid in the design of surfaces that prevent icing, a model and computational simulation of impact ice formation at the single droplet scale was implemented. The nucleation of a single supercooled droplet impacting on a substrate, in rime ice conditions, was simulated. Open source computational fluid dynamics (CFD) software was used for the simulation. To aid in the design of surfaces that prevent icing, a model of impact ice formation at the single droplet scale was proposed•No existing model simulates simultaneous impact and freezing of a single super-cooled water droplet•For the 10-week project, a low-fidelity feasibility study was the goal.

adhesion↗

Coating Reduces Ice Adhesion

The Shuttle Ice Liberation Coating (SILC) has been developed to reduce the adhesion of ice to surfaces on the space shuttle. SILC, when coated on a surface (foam, metal, epoxy primer, polymer surfaces), will reduce the adhesion of ice by as much as 90 percent as compared to the corresponding uncoated surface. This innovation is a durable coating that can withstand several cycles of ice growth and removal without loss of anti-adhesion properties. SILC is made of a binder composed of varying weight percents of siloxane(s), ethyl alcohol, ethyl sulfate, isopropyl alcohol, and of fine-particle polytetrafluoroethylene (PTFE). The combination of these components produces a coating with significantly improved weathering characteristics over the siloxane system alone. In some cases, the coating will delay ice formation and can reduce the amount of ice formed. SILC is not an ice prevention coating, but the very high water contact angle (greater than 140 ) causes water to readily run off the surface. This coating was designed for use at temperatures near -170 F (-112 C). Ice adhesion tests performed at temperatures from -170 to 20 F (-112 to -7 C) show that SILC is a very effective ice release coating. SILC can be left as applied (opaque) or buffed off until the surface appears clear. Energy dispersive spectroscopy (EDS) and x-ray photoelectron spectroscopy (XPS) data show that the coating is still present after buffing to transparency. This means SILC can be used to prevent ice adhesion even when coating windows or other objects, or items that require transmission of optical light. Car windshields are kept cleaner and SILC effectively mitigates rain and snow under driving conditions.

Smith, Trent↗

Thermal environment around the Space Shuttle with hot-gas jets for ice suppression

To prevent prelaunch ice formation on the external tank of the Space Shuttle, the final selected approach is to heat the surrounding air with vertical hot-gas jets located at the launch pad. This approach was considerably more cost-effective than other ice suppression methods considered, although its feasibility was not easily discernible due to the complex flowfield interactions. This paper describes how the use of vertical jets was first evaluated with the aid of a computational fluid dynamics (CFD) technique. An existing general-purpose CFD program (PHOENICS) was used to predict the thermal environment around the Shuttle under various jet configurations and wind conditions. The program accounts for effects of buoyancy, turbulence, and structural obstructions in the flowfield. The computed results showed physically plausible and consistent trends. The wind wake effects were found to be significant, and normally resulted in higher temperatures on the leeward side of the tank. High wind conditions were found to be more severe than calm wind conditions. The use of four jets with two different temperatures was identified as a promising option in which the air temperatures were raised sufficiently to prevent ice formation on the external tank, without excessive increase in Orbiter surface temperature. The use of the numerical model also facilitated the selection of test configurations and a test matrix for verifying the approach. Selected results of an experimental verification (by using a 2 percent scale model in a wind tunnel) are also presented.

Singhal, A. K.↗

The Prevention of the Ice Hazard on Airplanes

A review of various methods to prevent ice formation and adhesion to aircraft surfaces is given. It was concluded that the adhesion of ice to a surface may be reduced somewhat by the application of certain waxes and varnishes. In the experiments described, the varnishes containing calcium stearate and calcium oleate gave the best results. In wind tunnel tests, the adhesion was further reduced by the application of these waxes and varnishes to a thin, heat insulating layer of rubber. The adhesion of ice is greatly reduced when the surface consists of a vehicle which carries an oil in sufficient quantity so that the surface of the vehicle is self lubricating. Ice may be removed from wings, struts, wires and other parts of an airplane during flight by the inflation of properly constructed pneumatic rubber members, providing that these members have been previously treated with a suitable low adhesion oil.

Geer, William C↗

Icing tunnel tests of a glycol-exuding porous leading edge ice protection system on a general aviation airfoil

A glycol-exuding porous leading edge ice protection system was tested. Results show that the system is very effective in preventing ice accretion (anti-ice mode) or removing ice from an airfoil. Minimum glycol flow rates required for anti-icing are a function of velocity, liquid water content in the air, ambient temperature, and droplet size. Large ice caps were removed in only a few minutes using anti-ice flow rates. It was found that the shed time is a function of the type of ice, size of the ice cap, angle of attack, and glycol flow rate. Wake survey measurements show that there is no significant drag penalty for the installation or operation of the system tested.

Kohlman, D. L.↗