Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE CONVERTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High-resolution Giant Metrewave Radio Telescope H I 21 cm Imaging of the Host Galaxy of FRB 20250316A

We report Giant Metrewave Radio Telescope (GMRT) H I 21 cm imaging of NGC 4141, the host galaxy of FRB 20250316A at z = 0.0063. Our GMRT H I 21 cm images have spatial resolutions, at z ≈ 0.0063, of ≈0.48–8.0 kpc, and provide evidence for (i) a companion galaxy, LEDA 2582852, to the southwest, (ii) a nearby (27 kpc distant) H i cloud to the southwest, (iii) disturbances in the H I distributions of both NGC 4141 and LEDA 2582852, and (iv) high H I column densities in the southwestern outskirts of NGC 4141. A Sloan Digital Sky Survey spectrum yields a low metallicity and a high star formation rate (SFR) surface density in the southwestern disk of NGC 4141, and an Hα-based SFR estimate that is significantly higher than that at the same location from the Galaxy Evolution Explorer near-ultraviolet image, indicating a recent burst of star formation. The total SFR of NGC 4141 is also found to be higher via the Hα line than from the 1.4 GHz radio continuum. The above evidence indicates that NGC 4141 has recently (within the last ≈3 Myr) acquired metal-poor gas, via either a merger or accretion, that resulted in the southwestern starburst and that may also have triggered large-scale star-formation activity in NGC 4141, resulting in the formation of the stellar progenitor of FRB 20250316A and the other transients. Our highest-resolution (480 pc) GMRT H I 21 cm image finds no H I 21 cm emission from the location of FRB 20250316A or the nearby star-forming region, suggesting that most of the H I here has been either ionized or converted into the molecular phase. Our nondetection of continuum emission at the location of FRB 20250316A yields the 3σ upper limit νL 1.38 GHz < 4.4 × 10 34 erg s −1 on the 1.38 GHz radio luminosity of a putative persistent radio source associated with FRB 20250316A, one of the strongest constraints on the radio luminosity of such an associated persistent radio source.

Kaur, Balpreet [Pune University (India)] (ORCID:00↗

Collision Tracking in OpenMC: Methods and Applications in Neutron Noise, Neutron Imaging, Time-of-Flight, and Multiplicity Counting

We present the development and application of a collision tracking feature within the OpenMC Monte Carlo particle transport code, designed for diverse applications such as neutron spectroscopy, scatter camera system, neutron noise, and multiplicity counting simulations. This feature enables the tracking of individual particle collisions, with potential applications in nuclear nonproliferation, reactor physics, and nuclear security. Additionally, the feature holds potential for the calibration of neutron detectors, specifically in converting light output into energy deposited within the detectors. The implementation consists of a set of filters—such as reaction type, energy, cell, and material—that constrain the set of collisions that are tracked, extensions to the Python API to enable simple input specification, and support for writing either OpenMC’s native HDF5-based format or the Monte Carlo particle list format. This feature was added to the official OpenMC release in version 0.15.3. In this work, the feature will be applied to showcase scenarios such as time-of-flight simulations, scatter-camera imaging for neutron source localization, neutron-noise analysis to extract integral kinetic parameters such as the prompt decay constant α, and multiplicity counting to estimate the mass of special nuclear materials. Ultimately, this feature aims to expand the application scope of open-source Monte Carlo particle transport codes such as OpenMC.

Monte Carlo code↗

Microbial spies and bloggers: programming cells to convert environmental information into discernible signals

Microbes regulate their dynamic behaviors using the chemical and physical characteristics of their environment. The ability of microbes to continuously convert this physicochemical information into biochemical information and to use organic matter in the environment as a power source makes these organisms attractive as chassis for building sensors. However, most biosensors have severe limitations when considering applications in hard-to-image settings like soils, sediments, and wastewater. Emerging technologies at the interface of biomolecular design, microbiome engineering, and synthetic biology offer new tools to program cells and communities as biosensors for these settings. Here, in this review, we describe innovations in biosensor outputs that are enabling new applications in complex environments, including reporters that are read out using electrochemical, gas chromatography, hyperspectral imaging, and next-generation sequencing methods. We also discuss computational advances that are accelerating the diversification of sensing components by mining metagenomics data for new transcriptional regulators and by designing allosteric protein switches that directly regulate reporter outputs using analytes. We highlight emerging opportunities for programming undomesticated microbes in communities to function as distributed sensors in the environment. Finally, we discuss the need for responsible biosensor development and to modernize regulatory frameworks to support evidence-based assessment of environmental biosensors.

analyte↗

Data for Yield from Iowa’s first commercial miscanthus fields: implications of spatial variability for productivity and sustainability beyond research plots

This dataset contains biomass yield measurements and associated vegetation index data collected from commercial Miscanthus × giganteus fields in eastern Iowa during the 2022–2023 growing seasons. The data support the analyses presented in the article: “Yield From Iowa's First Commercial Miscanthus Fields: Implications of Spatial Variability for Productivity and Sustainability Beyond Research Plots.” We collected 105 ground-truth biomass samples from four mature commercial fields (>4 years old) covering 92.81 ha. Samples were taken from 3 m² quadrats that were hand-harvested in alignment with commercial harvest timing. Stem biomass (excluding leaves) was weighed, moisture-corrected, and converted to dry-matter yield expressed in Mg DM ha⁻¹. Sampling locations were selected to capture spatial variability visible in aerial imagery and were recorded using RTK GPS. Each biomass observation was paired with vegetation indices derived from high-resolution PlanetScope satellite imagery (3 m resolution). Images were acquired throughout the growing season, and indices were calculated to evaluate their ability to predict end-of-season biomass yield. Statistical and machine learning approaches were used to identify key predictors, and a linear regression model based on end-of-July Green Normalized Difference Vegetation Index (GNDVI) was developed and evaluated. This repository includes the data used in that modeling workflow. Management practices, economic data, full imagery time series, and additional methodological details are described in the associated publication and are not included here. The dataset consists of three comma-separated value (CSV) files: 1. Combine_Groundtruth_Yield_VI_22_23.csv This file contains ground-truth biomass yield measurements and associated key vegetation index values collected during the 2022 and 2023 growing seasons. Rows: 105 observations Columns: Year — Year of observation (2022 or 2023) Field — Field location identifier Sample_number — Unique sample identifier GNDVI_End_Jul — Green Normalized Difference Vegetation Index calculated at end of July GNDVI_End_Aug — Green Normalized Difference Vegetation Index calculated at end of August NDRE_End_Aug — Normalized Difference Red Edge index calculated at end of August Biomass_Stem_Yield_MgDM/ha — Measured stem biomass yield (megagrams dry matter per hectare) 2. trainData_GNDVI.csv This file contains the subset of observations used to train the predictive relationship between July GNDVI and biomass yield. Rows: 76 observations Columns: Unnamed: 0 — Row index retained from the original data processing workflow GNDVI_End_Jul — GNDVI at end of July Stem_Yield_MgDM/ha — Observed stem biomass yield (Mg DM ha⁻¹) 3. testData_GNDVI.csv This file contains the test dataset used to evaluate model performance. Rows: 29 observations Columns: Unnamed: 0 — Row index retained from the original data processing workflow GNDVI_End_Jul — GNDVI at end of July Predicted_Yield_MgDM/ha — Model-predicted stem biomass yield (Mg DM ha⁻¹) Observed_Yield_MgDM/ha — Measured stem biomass yield (Mg DM ha⁻¹)

Potential yield, yield gap, in-field management, y↗

Boron-Based Neutron Scintillator Screen Characterization with X-Rays and Neutrons

Recent work on boron-based neutron scintillator screens suggests these screens can offer superior performance when compared to commonly used screens. Borated neutron scintillator screens perform well in terms of light output (5-6 times greater than a standard Gadox screen) and detection effi-ciency (larger than standard LiF+ZnS screens). However, previously manu-factured boron-based screens have exhibited non-uniform surface coating and a poor mixture between phosphor and converter particles. The objective of this work was to evaluate newly fabricated scintillator screens to deter-mine if enhanced fabrication methods produced a more homogeneous distribution between neutron converter and scintillation phosphor particles. Uniformity of scintillator material deposition was also inspected. This new iteration of screens appeared more uniform than previous generations with the new coating method improving surface chemistry and scintillator material homogeneity. Additionally, a new methodology for screen characterization, involving the correlation of a neutron image taken with a borated scintillator screen to X-ray computed tomography of that same screen, was demonstrated to elucidate a relationship between scintillator screen thickness and relative light output of the screen under neutron exposure. This method suggested that the ideal thickness of scintillator material was ~150 µm to maximize light output of the screen.

36 - MATERIALS SCIENCE↗

Oxide nucleation via threshold-driven volume instability in Ni oxidation

Oxide nucleation dictates the onset of metal oxidation, yet the atomistic pathways bridging initial oxygen adsorption to bulk phase transformation remain elusive. Here, we utilize in-situ atomic-resolution imaging to directly capture the nucleation of nickel oxide, revealing a threshold-driven, cooperative transformation of Ni into NiO. Our observations identify a distinct incubation period during which oxygen progressively accumulates in subsurface layers. Once a critical concentration and penetration depth are reached, a collective lattice reconfiguration is triggered, abruptly converting multiple Ni layers into NiO. Atomistic simulations corroborate this mechanism, identifying a cooperative lattice instability induced by subsurface oxygen saturation. These results establish subsurface oxygen incorporation as the missing mechanistic link between surface adsorption and three-dimensional oxide formation, providing an atomistic framework to understand and control reactive phase transformations in materials synthesis, catalysis, and degradation.

36 MATERIALS SCIENCE↗

Using Fiducial Markers for Pose Estimation of an OSWEC in a Wave Tank: Preprint

In this study, we consider a novel method of sensing the motion of a wave energy converter during testing in a wave flume under the influence of incoming waves. The wave energy converter considered in our research is an oscillating surge wave energy converter, which is a hinged paddle that responds to incoming waves. Motion sensing is normally done with inertial sensors, which can hinder the motion due to suspended cables that carry power and transmit signals. Our proposed method is contactless and can be implemented economically. A camera is used to record different marker patterns affixed to the moving paddle and the motion deduced by pose estimation algorithms. Fiducial markers are commonly used for robot localization and in augmented reality. There are many types of fiducial markers, including ArUco-type markers which are accurate, fast and robust. The system consists of markers attached to the paddle element and recorded using a machine vision camera. A pose estimation algorithm is then applied to the detected markers to estimate the tilt of the paddle. In this work, we examine the challenges of image acquisition and calibration for underwater targets, compare the motion obtained by this new system with a calibrated tilt sensor and identify areas where the new system may be superior.

computer vision↗

Simultaneous on-chip generation of violet, blue, cyan, green, yellow, orange, and red light from an octave-spanning infrared frequency comb

An integrated, multi-spectral visible-light source could significantly benefit technologies such as displays, medical imaging, spectroscopy, visible-light communications, and astrophysics. However, despite recent advances in chip-scale visible lasers, simultaneously generating light of all colors in a single chip has been challenging. Existing solutions are either not suitable for full chip-scale integration, or are fundamentally difficult to scale. Here we demonstrate the simultaneous on-chip generation of infrared, red, orange, yellow, green, cyan, blue, and violet light. Leveraging the low loss, low dispersion, and high density of modes of an adiabatic multimode silicon nitride (SiN) microresonator, we use a single infrared pump of moderate power (~130 mW) to produce an octave-spanning infrared frequency comb that is then converted to different portions of the visible spectrum. We measure non-mode-locked combs and soliton steps corresponding to mode-locked states, making our comb generator suitable for applications that demand either low or high coherence. Since the required pump power is compatible with high-power lasers demonstrated in the same SiN platform, our multi-octave light generator can be fully integrated in a chip-scale form factor. We envision that such a light source will be a catalyst for the development and deployment of miniaturized multi-spectral technologies for quantum systems, medical imaging, displays, and spectroscopy.

47 OTHER INSTRUMENTATION↗

Using X-ray spectrum imaging to quantify fission gas in high-burnup UO2 fuel

Analysis of fission gas bubbles (FGBs) in light-water reactor (LWR) fuel is needed to improve the understanding and predictive capability of fuel evolution under normal- and transient conditions. One of the most important parameters of a FGB is the pressure of the gas, primarily Xe, inside it. Bubble volume and location (inter- vs. intragranular) are important considerations as well. However, experimental analysis of such bubbles is challenging due to their small size and embedded nature, and usefulness of the data requires large numbers be analyzed. This paper proposes a method to measure the pressure of Xe bubbles using X-ray spectrum imaging (XSI) in scanning transmission electron microscopy (STEM). From X-ray generation and instrumental parameters, the number of Xe atoms yielding a given number of Xe L-series X-ray counts is estimated, and then from the estimated volume of the bubble the Xe density is estimated, which can then be converted to pressure via an equation-of-state. We apply the method to XSI datasets from high burnup (HBu) fuel from North Anna 1 reactor in as-irradiated and post-LOCA-test conditions and find Xe pressures in the FGBs clustered around 1 GPa.

Parish, Chad [ORNL] (ORCID:0000000312097439)↗

Large area position sensitive detector for thermal neutrons

Large area thermal neutron detectors are applied in many fields including industrial imaging, nuclear safeguarding, neutron scattering, and fundamental science. Historically, these detectors were based on 3 He gas proportional counters despite the limitations of 3 He detectors such as high cost, limited supply, non-uniform spatial resolution, and depth of absorption problems. Two alternatives to 3 He detectors are 6 Li-loaded glass scintillators, and powdered ZnS(Ag) scintillators mixed with 6LiF neutron converters. The 6 LiF/ZnS(Ag) scintillator has advantages over 6 Li glass as it is less expensive and can be produced in larger areas, although its self-absorption presents a problem. In this work, we developed a large area thermal neutron detector based on 6 LiF/ZnS(Ag) scintillator coupled with wavelength shifting fibers. The detector uses resistive charge divider-based position encoding. We further modified and improved the method by 2D segmentation of the detector using modular multichannel readout electronics. This segmentation approach allows for a combination of large detector area, improved spatial resolution, and increased count rate. Furthermore, spatial resolution can be variable across the detector area by adjusting the segment size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and Application of In Situ Nanocharacterization to Photocatalytic Materials for Solar Fuel Generation

Photocatalytic materials offer an attractive approach for converting solar energy into chemical energy but the performance of the current generation of materials is insufficient to make a technology viable. To address this deficiency, it is necessary to develop a fundamental atomic level understanding of the functioning of such materials so that strategies can be developed to improve performance. This project was undertaken to explore the fundamental structure and properties of photocatalytic materials using atomic resolution imaging and spectroscopy techniques available on advanced transmission electron microscopy. Specifically, there is a need to develop an understanding of how atomic structures/defects and nanoparticle configurations regulate electronic, optical, and catalytic properties to facilitate the design of next generation photocatalysts for solar fuel production. The work focused on fundamental materials information that can be gained from advanced transmission electron microscopy study on novel and existing photocatalytic systems with an emphasis on the hydrogen evolution reaction (HER). Throughout the project, new instrumentation and microscopy characterization tools were developed. Two focus areas were: developing in situ TEM methods and advanced electron energy-loss spectroscopic for nanoscale analysis of catalysts. The work spanned a period of 12 years and for convenience, the report is divided into four phases, approximately corresponding to the four funding periods of the program. Most of the significant results are reported in archival journal publications.

36 MATERIALS SCIENCE↗

Integrating Flow Imaging Analysis and Single-Particle ICP-TOFMS for Comprehensive Micro- and Nanoplastic Characterization

Flow imaging analysis (FIA), provides composition-agnostic morphological characterization. These measurements of particle size and shape are valuable to mass-based analysis, such as single particle inductively coupled plasma time-of-flight mass spectrometry (sp-ICP-TOFMS), which provides quantitative data on elements within particles. Using these two methods together enables informed use of geometric assumptions required by sp-ICP-TOFMS, as particle mass is typically converted to a particle diameter using assumed-spherical geometry. To validate this concept, parallel measurements to determine particle diameters were performed by FIA and sp-ICP-TOFMS on four particle suspensions: 300 nm polystyrene Eu-doped nanoparticles, 1 μm Fe-rich beads, 3 μm four element calibration polystyrene beads and 5 μm polystyrene beads. The Fe-particles obtained the highest percent difference from the manufacturer’s nominal diameter, as the mean diameter obtained by FIA was overestimated by 21% and sp-ICP-TOFMS underestimated the mean diameter by 20.7%. Two types of particles were selected to test the effect of varying the particle number concentrations (PNC) on sizing accuracy, and both methods accurately sized each particle population at the PNC expected. Single particle analysis of carbon has continued to be a popular research topic, with direct applications to environmental pollutants in terms of nano- and micro- plastics. Real-world plastic particles were studied, and FIA’s measured circularity values demonstrated that the particles deviated from spherical geometries, therefore sp-ICP-TOFMS data should be interpreted as mass-based rather than size-based. Combining these techniques enables improved interpretation of particle populations and evaluation of particle sizes.

Szakas, Sarah [ORNL] (ORCID:0000000241332197)↗

Infrared Cloud Imager Instrument Intercomparison Report

The Infrared Cloud Imager Instrument Intercomparison was a guest instrument deployment by NWB Sensors to the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) User Facility observatory on the Southern Great Plains (SGP) between May 18 and December 12, 2023. NWB Sensors is a company that has developed a commercially available infrared cloud imager (ICI). The ICI provides radiometrically calibrated, full-sky images of the downwelling infrared radiance in the 7.3-14 µm band. In addition, it provides cloud radiance as the residual between the observed radiance and the modeled cloud-free radiance as well as derived cloud products. The instrument is used in applications that require consistent detection of clouds across day and night. For more information, consult the instrument's webpage. The primary goal of the deployment was to validate the radiometric accuracy of the ICI. The ICI uses a proprietary calibration method to convert the raw data from its infrared camera into downwelling radiance. Unlike similar instruments, the system does not have an onboard blackbody calibration standard. Instead, NWB Sensors characterizes each ICI camera individually in an environmental chamber while looking at a blackbody standard. The resulting (proprietary) calibration is used operationally in the instrument and has been demonstrated to be stable over long periods. To validate the radiometric products from the ICI, an intercomparison between the ICI data products and those from ARM’s atmospheric emitted radiance interferometer (AERI) was made. The AERI is a best-in-class instrument for measuring downwelling infrared radiance (Gero et al. 2025). A weighted integration of the AERI’s spectral radiances across the ICI’s camera response was performed. The resulting radiance (herein called the AERI radiance) was directly compared to the zenith radiance concurrently observed by the ICI. The results of these comparisons are reported in the next section of this report.

54 ENVIRONMENTAL SCIENCES↗

Measurement of directional muon beams generated at the Berkeley Lab Laser Accelerator

We present the detection of directional muon beams produced using a PW laser facility at the Lawrence Berkeley National Laboratory. The muon source is a multi-GeV electron beam generated in a laser-plasma accelerator interacting with a high- converter target. The GeV photons resulting from the interaction are converted into a high-flux, directional muon beam via pair production. By employing scintillators to capture delayed events, we were able to identify the produced muons and characterize the source. Using theoretical knowledge of the muon production process combined with simulations that are in excellent agreement with the experiments, we demonstrate that laser-plasma accelerators have the capability of generating electron beams with characteristics suitable to produce GeV-scale muons that offer unique advantages with respect to the cosmic background. Laser-plasma-accelerator-based muon sources can therefore enhance muon imaging applications thanks to their compactness, directionality, and high yields, which reduce the exposure time by orders of magnitude compared to cosmic ray muons. Using the eant4-based simulation code we developed to gain insight into the experimental results, we can design future experiments and applications based on LPA-generated muons.

Terzani, Davide↗

High average-flux laser-driven neutron source

Laser-driven neutron generation is an attractive alternative to more established methods for compact, short-pulse-duration neutron sources with applications in medical science, material science and imaging. Despite extensive investigation of various techniques, achieving performance comparable to nuclear reactors or conventional accelerators remains challenging. In this work, we generate a stable, high-repetition-rate laser-driven neutron source reaching a record average flux of 7.8 × 10 7 n/sr/s, improving on other existing laser-based sources by more than one order of magnitude. Our approach is based on a two-step process where electrons are accelerated to relativistic energies via laser wakefield acceleration (LWFA), and subsequently generate neutrons through Bremsstrahlung emission followed by photonuclear reactions in a tungsten converter. Experimental results, supported by Monte Carlo simulations, show a neutron flux of 3.0 × 10 7 n/cm 2 /s near the target, on par with some compact accelerator-based neutron sources. Additionally, a direct comparison with the target-normal sheath acceleration (TNSA) pitcher-catcher scheme, performed on the same laser system, reveals a significantly higher total neutron yield of 3.9 × 10 8 neutrons per shot, outperforming the TNSA scheme by several orders of magnitude. These findings represent a significant advancement towards the development of practical laser-driven neutron sources and highlight the advantages of LWFA-based neutron generation for future applications.

Vallières, Simon [Institut National de la Recherch↗

Dosimetric and biological impact of activity extravasation of radiopharmaceuticals in PET imaging

The increasing use of nuclear medicine and PET imaging has intensified scrutiny of radiotracer extravasation. To our knowledge, this topic is understudied but holds great potential for enhancing our understanding of extravasation in clinical PET imaging. This work aims to (1) quantify the absorbed doses from radiotracer extravasation in PET imaging, both locally at the site of extravasation and with the extravasation location as a source of exposure to bodily organs and (2) assess the biological ramifications within the injection site at the cellular level. A radiation dosimetry simulation was performed using a whole-body 4D Extended Cardiac-Torso (XCAT) phantom embedded in the GATE Monte Carlo platform. A 10-mCi dose of 18 F-FDG was chosen to simulate a typical clinical PET scan scenario, with 10% of the activity extravasated in the antecubital fossa of the right arm of the phantom. The extravasation volume was modeled as a 5.5 mL rectangle in the hypodermal layer of skin. Absorbed dose contributions were calculated for the first two half-lives, assuming biological clearance thereafter. Dose calculations were performed as absorbed doses at the organ and skin levels. Energy deposition was simulated both at the local extravasation site and in multiple organs of interest and converted to absorbed doses based on their respective masses. Each simulation was repeated ten times to estimate Monte Carlo uncertainties. Biological impacts on cells within the extravasated volume were evaluated by randomizing cells and exposing them to a uniform radiation source of 18 F and 68 Ga. Particle types, their energies, and direction cosines were recorded in phase space files using a separate Geant4 simulation to characterize their entry into the nucleus of the cellular volume. Subsequently, the phase space files were imported into the TOPAS-nBio simulation to assess the extent of DNA damage, including double-strand breaks (DSBs) and single-strand breaks (SSBs). Organ-level dosimetric estimations are presented for 18 F and 68 Ga radionuclides in various organs of interest. With 10% extravasation, the hypodermal layer of the skin received the highest absorbed dose of 1.32 ± 0.01 Gy for 18 F and 0.99 ± 0.01 Gy for 68 Ga. The epidermal and dermal layers received absorbed doses of 0.07 ± 0.01 Gy and 0.13 ± 0.01 Gy for 18 F, and 0.14 ± 0.01 Gy and 0.29 ± 0.01 Gy for 68 Ga, respectively. In the extravasated volume, 18 F caused an average absorbed dose per nucleus of 0.17 ± 0.01 Gy, estimated to result in 10.58 ± 0.50 DSBs and 268.11 ± 12.43 SSBs per nucleus. For 68 Ga, the absorbed dose per nucleus was 0.11 ± 0.01 Gy, leading to an estimated 6.49 ± 0.34 DSBs and 161.24 ± 8.12 SSBs per nucleus. Absorbed doses in other organs were on the order of micro-gray (µGy). The likelihood of epidermal erythema resulting from extravasation during PET imaging is low, as the simulated absorbed doses to the epidermis remain below the thresholds that trigger such effects. Moreover, the organ-level absorbed doses were found to be clinically insignificant across various simulated organs. The minimal DNA damage at the extravasation site suggests that long-term harm, such as radiation-induced carcinogenesis, is highly unlikely.

DNA strand breaks↗

Optical galaxy cluster mock catalogs with realistic projection effects: Validations with the SDSS clusters

Galaxy clusters identified in optical imaging surveys suffer from projection effects: Physically unassociated galaxies along a cluster’s line of sight can be counted as its members and boost the observed richness (the number of cluster members). To model the impact of projection on cluster cosmology analyses, we apply a halo occupation distribution model to 𝑁-body simulations to simulate the red galaxies contributing to cluster members, and we use the number of galaxies in a cylinder along the line of sight (counts in cylinders) to model the impact of projection on cluster richness. We compare three projection models: uniform, quadratic, and Gaussian, and we convert between them by matching their effective cylinder volumes. We validate our mock catalogs using SDSS redMaPPer clusters’ data vectors, including counts vs richness, stacked lensing signal, spectroscopic redshift distribution of member galaxies, and richness remeasured on a redshift grid. We find the former two are insensitive to the projection model, while the latter two favor a quadratic projection model with a width of ≈180 ℎ −1 Mpc (equivalent to the volume of a uniform model with a width of 100 ℎ −1 Mpc and a Gaussian model with a width of 110 ℎ −1 Mpc, or a Gaussian redshift error of 0.04). Furthermore, our framework provides an efficient and flexible way to model optical cluster data vectors, paving the way for a simulation-based joint analysis for clusters, galaxies, and shear.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative local state of charge mapping by operando electrochemical fluorescence microscopy in porous electrodes

We introduce operando quantitative electrochemical fluorescence state of charge mapping (QEFSM), a non-invasive technique to study operating electrochemical systems along with a new design of optically transparent microfluidic redox flow cells compatible with the most demanding optical requirements. QEFSM allows quantitative mappings of the concentration of a particular oxidation state of a redox-active species within a porous electrode during its operation. In this study, we used confocal microscopy to map the fluorescence signal of the reduced form of 2,7-anthraquinone disulfonate (AQDS) in a set of multistep-chronoamperometry experiments. Calibrating these images and incorporating an analytical model of quinhydrone heterodimer formation with no free parameters, and accounting for the emission of each species involved, we determined the local molecular concentration and the state of charge (SOC) fields within a commercial porous electrode during operation. With this method, electrochemical conversion and species advection, reaction and diffusion can be monitored at heretofore unprecedented transverse and axial resolution (1 μm and 25 μm, respectively) at frame rates of 0.5 Hz, opening new routes to understanding local electrochemical processes in porous electrodes. Here, we observed pore-scale SOC inhomogeneities appearing when the fraction of electroactive species converted in a single pass through the electrode becomes large.

42 ENGINEERING↗