TRW plasma wave experiment for the IMP-H mission
The IMP-H plasma wave experiment is designed to extend knowledge of wave-particle interactions in the disturbed cislunar region, the distant geomagnetic tail, the upstream solar wind, and the flanks of the magnetosheath-shock interface. It is expected to identify plasma instabilities, study particle acceleration and heating at collisionless shocks and other discontinuities, analyze turbulent conductivity and field line merging, and provide new information on dissipation processes for suprathermal particles. Instrumentation for the plasma wave experiment is designed to measure local electric and magnetic field oscillations over the frequency range 10 Hz to 100 kHz. A 24 inch electric dipole, a 7 inch diameter air core search coil, and the associated preamplifiers are mounted on a spacecraft counterweight boom. The frequency range of 10 Hz to 100 kHz for both E and B is processed using an eight-channel spectrum analyzer located in the instrument main-body package (a standard IMP trapezoidal module, 3 inches high). Electric fields as small as 10-100 microvolts/meter and magnetic signals as small as 1-3 milligamma will be detected.