Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Shock-induced metallization of polystyrene along the principal Hugoniot investigated by advanced thermal density functionals

To date, none of the ab-initio molecular dynamics simulations of polystyrene, often used as an ablator material in inertial confinement fusion targets, with the standard ground-state exchange-correlation (XC) functional in density-functional theory can satisfactorily agree with experiments in terms of reflectivity measurements. Here, we use recently developed thermal strongly constrained and appropriately normed Laplacian dependent meta-generalized gradient approximation XC density functional (T-SCAN-L) and thermal hybrid XC density functional (KDT0) to show that the inclusion of thermal and inhomogeneity effects is crucial for accurate prediction of structural evolution and corresponding insulator-metal transition (IMT) during shock compression. Optical reflectivity calculated as an indicator of IMT is in perfect accord with experimental data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of Models and Measurements to Estimate Solar Radiation for 1-Axis Tracking Modules at NREL’s SRRL

Solar radiation reaching photovoltaic (PV) modules on a 1-axis tracking system can be measured by reference cells or thermopiles. The former is often biased due to the reflection of solar radiation by the glass cover of the PV. The uncertainty can be moderated by applying a correction factor, as a function of solar incident angle and the refractive index of the glass, to the measurement. On the other hand, solar radiation on the inclined PV panels can be computed by transposition models using global horizontal irradiance (GHI) observations from thermopiles. This study examines the models and measurements to estimate solar radiation for 1-axis tracking modules at the National Renewable Energy Laboratory’s (NREL’s) Solar Radiation Research Laboratory (SRRL). The 1-minute plane-of-array (POA) irradiances from 2019 are computed using the observed GHIs and a transposition model developed by Perez et al. The POA irradiances are compared with the observation by an IMT reference cell and a Kipp & Zonen CM Pyranometer 22 (CMP22) thermopile. For the SRRL’s 1-axis tracking system with an annual solar energy of 2323.9 kWh/m 2 , the POA irradiance is overestimated by ~70 kWh/m 2 using the transposition model. This bias is reduced by more than 50% using the IMT measurements calibrated by a correction factor for a PV surface of antireflection coated glass.

POA irradiance↗

Bifacial PV test-bed irradiance measurements

Data for 2 front-facing and 4 rear-facing IMT irradiance sensors placed on a scaled-down setup that replicate a PV array in a highly-reflective rooftop. The test-bed consist of 3 rows of 20x2ft aluminum sheets (the “panels”), supported by a Unistrut structure, with 6 irradiance sensors (IMT) measuring front and rear irradiance in the center module of the center row. High quality weather-station data available

14 SOLAR ENERGY↗

Modal Test of the NASA Mobile Launcher at Kennedy Space Center

The NASA Mobile Launcher (ML), located at Kennedy Space Center (KSC), has recently been modified to support the launch of the new NASA Space Launch System (SLS). The ML is a massive structure—consisting of a 345-foot tall tower attached to a two-story base, weighing approximately 10.5 million pounds—that will secure the SLS vehicle as it rolls to the launch pad on a Crawler Transporter, as well as provide a launch platform at the pad. The ML will also provide the boundary condition for an upcoming SLS Integrated Modal Test (IMT). To help correlate the ML math models prior to this modal test, and allow focus to remain on updating SLS vehicle models during the IMT, a ML-only experimental modal test was performed in June 2019. Excitation of the tower and platform was provided by five uniquely-designed test fixtures, each enclosing a hydraulic shaker, capable of exerting thousands of pounds of force into the structure. For modes not that were not sufficiently excited by the test fixture shakers, a specially-designed mobile drop tower provided impact excitation at additional locations of interest. The response of the ML was measured with a total of 361 accelerometers. Following the random vibration, sine sweep vibration, and modal impact testing, frequency response functions were calculated and modes were extracted for three different configurations of the ML in 0 Hz to 12 Hz frequency range. This paper will provide a case study in performing modal tests on large structures by discussing the Mobile Launcher, the test strategy, an overview of the test results, and recommendations for meeting a tight test schedule for a large-scale modal test.

Hydraulic shakers↗

TPSAS-NF1676L-31853-DND

Risk that Orion arrives later than Space Launch System (SLS). MSO mitigates this risk by using a mass simulator for SLS’ tests. An Orion simulator for the Integrated Modal Test (IMT) and Umbilical Release and Retraction Tests (URRT) mitigates schedule risk by significant timeframe. A clean sheet alternate being pursued - analysis shows matching modal characteristics unnecessary; rigid simulator is acceptable wrt existing SLS accelerometer locations and shaker placement/size. Key Simulator Requirements: Representative mass, CG, rigid modal characteristics, high fidelity interface at MSA. Pre-test analyses show that MSO vertical CG could be up to 40” low without affecting IMT.

Steve Cutright↗

Integrated Modal Test of the Artmis I Launch Vehicle

The dynamic testing campaign for the Artemis I launch vehicle culminated in the Integrated Modal Test (IMT). The IMT consisted of the Space Launch System with a mass simulator of Orion (MSO) on top of the SLS stack, which rested on the deck of the mobile launcher (ML) and mount mechanisms. The modal testing met the goal to capture a set of target modes under 7Hz, in two test configurations, using 298 accelerometer locations and 472 accelerometer channels. Overall the model of the test matched very well with the data without tuning the model with the exception of the first torsion mode, which was measured at a much lower frequency than predicted at when excited at higher levels.

Dan Lazor↗

Evaluation of Models and Measurements to Estimate Solar Radiation for 1-Axis Tracking Modules at NREL's SRRL: Preprint

Solar radiation reaching photovoltaic (PV) modules on a 1-axis tracking system can be measured by reference cells or thermopiles. The former is often biased due to the reflection of solar radiation by the glass cover of the PV. The uncertainty can be moderated by applying a correction factor, as a function of solar incident angle and the refractive index of the glass, to the measurement. On the other hand, solar radiation on the inclined PV panels can be computed by transposition models using global horizontal irradiance (GHI) observations from thermopiles. This study examines the models and measurements to estimate solar radiation for 1-axis tracking modules at National Renewable Energy Laboratory’s (NREL’s) Solar Radiation Research Laboratory (SRRL). The 1-minute plane-of-array (POA) irradiances in 2019 are computed using the observed GHIs and a transposition model developed by Perez et al. The POA irradiances are compared with the observation by an IMT reference cell and a Kipp & Zonen CM Pyranometer 22 (CMP22) thermopile. For SRRL’s 1-axis tracking system with the annual solar energy of 2323.9 kWh/m2, the POA irradiance is overestimated by ~70 kWh/m2 using the transposition model. This bias is reduced by more than 50% using the IMT measurements calibrated by a correction factor for a PV surface of antireflection coated glass.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Reconfigurable Cascaded Thermal Neuristors for Neuromorphic Computing

While the complementary metal-oxide semiconductor (CMOS) technology is the mainstream for the hardware implementation of neural networks, an alternative route is explored based on a new class of spiking oscillators called “thermal neuristors”, which operate and interact solely via thermal processes. Utilizing the insulator-to-metal transition (IMT) in vanadium dioxide, a wide variety of reconfigurable electrical dynamics mirroring biological neurons is demonstrated. Notably, inhibitory functionality is achieved just in a single oxide device, and cascaded information flow is realized exclusively through thermal interactions. To elucidate the underlying mechanisms of the neuristors, a detailed theoretical model is developed, which accurately reflects the experimental results. In conclusion, this study establishes the foundation for scalable and energy-efficient thermal neural networks, fostering progress in brain-inspired computing.

36 MATERIALS SCIENCE↗

Temperature-dependent optical constants of vanadium dioxide thin films deposited on polar dielectrics

Coating polar dielectrics with thin film vanadium dioxide (VO 2 ) enables one to exploit the temperature-dependent phase transition within VO 2 to actively tune and modulate surface phonon polaritons at mid-infrared. However, controlling the behavior of such systems requires intimate knowledge of the temperature-dependent optical constants of VO 2 , which depend greatly on the growth conditions and substrate material. Here, in this work, we accurately determine the complex optical constants of VO 2 on polar dielectrics across the insulator-to-metal phase transition (IMT) using only normal incident reflectance spectra by analyzing the reflectance with Kramers–Kronig relations and thin film Fresnel equations. This non-ellipsometry technique offers an advantage in determining the refractive index using a standard infrared spectrometer.

36 MATERIALS SCIENCE↗

The “Fresnel Equations” for Diffuse radiation on Inclined photovoltaic Surfaces (FEDIS)

Here the well-known Fresnel equations solve for the reflection and transmission of light for precise incident angles. The transmission of diffuse radiation incident on a planar or domed surface is often needed for real-world applications. Due to the complexity of the Fresnel equations, the analytical solution of the integration has hitherto been unobtainable over the last centuries. Therefore, this problem was numerically solved by integrating the angular transmittances in space often leading to substantial computing burden and bias in the results. To efficiently estimate the solar energy resource for a glass-covered photovoltaic (PV) module, we derive an analytical solution of diffuse transmission based on the rigorous integration of an alternate form of the Fresnel equations. The approach leads to a simple yet accurate relative transmittance model that reconciles the solar energy sensed by pyranometers and PV panels. With limited and clearly stated approximations, the complex mathematical derivation resulted in an elegant solution. An experiment using 1-year of data at the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) shows that the new model dramatically decreases the disparity between the solar radiation measurements by a Kipp and Zonen CM Pyranometer 22 (CMP22) and an IMT reference cell on a 1-axis tracking system. The solution in this paper can be widely used in scientific and engineering research, development, and applications wherever the Fresnel equations are used.

14 SOLAR ENERGY↗

Improved field evaluation of reference cells using spectral measurements

Output from an IMT reference solar cell mounted on a one-axis tracking surface is investigated using spectral measurements covering the 350–1650 nm range for selected days throughout the year. Comparisons are made to a Class-A pyranometer also mounted on the one-axis tracking surface. Systematic biases over the day and year are observed in the ratio of the reference cell’s measurements to reference pyranometer measurements. This systematic bias is associated with the spectral, temperature, and angle-of-incident effects that differ between the reference cell and the reference pyranometer. The comparison is done for selected clear and totally cloudy days to determine the magnitude of the effects and to characterize the influence of these effects on the reference cell measurements. A model to calculate the reference cell output based on spectral irradiance and reference cell temperature is introduced.

14 SOLAR ENERGY↗

Switching Dynamics in Vanadium Dioxide-Based Stochastic Thermal Neurons

We report on switching dynamics of individual and coupled vanadium dioxide (VO 2 ) devices subject to voltage pulses as the temperature is systematically varied from room temperature spanning the insulator–metal transition (IMT) temperature. The switching voltage of single devices has a strong relationship with both temperature and voltage pulsewidth. Two-step switching in connected VO 2 devices has been noted in current transient plots and was found to depend on temperature, pulsewidth, and pulse amplitude. Experimental switching behavior measured from VO 2 artificial neurons was implemented into a spiking neural network (SNN). During training, modulating the switching voltage via temperature affords a novel method to implement homeostasis with the coupled devices. Simulation results show the efficacy of the stochastic neuronal characteristics and the proposed homeostasis mechanism on a standard digit recognition task. As a result, these studies contribute to ongoing efforts in neuromorphic computing exploiting collective phase transitions.

42 ENGINEERING↗

Very High Efficiency Dedicated Outdoor Air System Field Site Re-Evaluation

The study reported here evaluated the long-term performance of Very High Efficiency (VHE) Dedicated Outside Air Systems (DOASs) installed at eight sites that participated in field evaluation studies performed by the Northwest Energy Efficiency Alliance (NEEA) and Institute for Market Transformation (IMT) from 2015 through 2020. The study compared the energy performance of the systems in 2021-2022 to the findings of the original evaluation. It also evaluated the indoor environmental quality (IEQ) as perceived by occupants and building operator feedback before and after the system conversion. The findings of the study are important for building owners and managers who are considering adopting VHE DOASs. The study found that the systems: (1) consistently saved energy over the long term, (2) improved occupant comfort, and (3) received positive feedback from building operators. All of the sites had similar or improved energy savings over the pre-conversion system compared to the original evaluation savings, and only one site had a small reduction in energy savings. The sites averaged 48 percent whole site energy savings compared to the pre-conversion system. The continued energy performance of these sites provides strong evidence that the energy savings achieved by VHE DOAS retrofits will be sustained long term. The study also investigated the changes in occupant comfort resulting from the VHE DOAS retrofit. Responses to a survey sent to the sites’ occupants revealed that the conversion resulted in a better indoor environment for the occupants. Most respondents reported that their satisfaction increased, and dissatisfaction decreased post-conversion. Overall occupants were 43 percent more satisfied and 30 percent less dissatisfied post-conversion compared to pre-conversion. The study's findings suggest that a VHE DOAS can be a solution to improve the energy efficiency, reduce energy costs, and increase occupant comfort in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pressure-Induced Insulator–Metal Transition in Two-Dimensional Mott Insulator NiPS 3

The pressure-induced insulator to metal transition (IMT) of layered magnetic nickel phosphorous tri-sulfide NiPS 3 was studied in-situ under quasi-uniaxial conditions by means of electrical resistance (R) and X-ray diffraction (XRD) measurements. This sluggish transition is shown to occur at 35 GPa. Transport measurements show no evidence of superconductivity to the lowest measured temperature (~2 K). The structure results presented here differ from earlier in-situ work that subjected the sample to a different pressure state, suggesting that in NiPS 3 the phase stability fields are highly dependent on strain. Furthermore, it is suggested that careful control of the strain is essential when studying the electronic and magnetic properties of layered van der Waals solids.

36 MATERIALS SCIENCE↗

System and method for improving ultrasound image acquisition and replication for repeatable measurements of vascular structures

High resolution B-mode ultrasound images of the common carotid artery are obtained with an ultrasound transducer using a standardized methodology. Subjects are supine with the head counter-rotated 45 degrees using a head pillow. The jugular vein and carotid artery are located and positioned in a vertical stacked orientation. The transducer is rotated 90 degrees around the centerline of the transverse image of the stacked structure to obtain a longitudinal image while maintaining the vessels in a stacked position. A computerized methodology assists operators to accurately replicate images obtained over several spaced-apart examinations. The methodology utilizes a split-screen display in which the arterial ultrasound image from an earlier examination is displayed on one side of the screen while a real-time live ultrasound image from a current examination is displayed next to the earlier image on the opposite side of the screen. By viewing both images, whether simultaneously or alternately, while manually adjusting the ultrasound transducer, an operator is able to bring into view the real-time image that best matches a selected image from the earlier ultrasound examination. Utilizing this methodology, measurement of vascular dimensions such as carotid arterial IMT and diameter, the coefficient of variation is substantially reduced to values approximating from about 1.0% to about 1.25%. All images contain anatomical landmarks for reproducing probe angulation, including visualization of the carotid bulb, stacking of the jugular vein above the carotid artery, and initial instrumentation settings, used at a baseline measurement are maintained during all follow-up examinations.

Selzer, Robert H.↗