Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENTS - STRAIN GAUGES - TUCKERMAN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Measurements of DSD Second Moment Based on Laser Extinction

Using a technique recently developed for estimating the density of surface dust dispersed during a rocket landing, measuring the extinction of a laser passing through rain (or dust in the rocket case) yields an estimate of the 2nd moment of the particle cloud, and rainfall drop size distribution (DSD) in the terrestrial meteorological case. With the exception of disdrometers, instruments that measure rainfall make in direct measurements of the DSD. Most common of these instruments are the rainfall rate gauge measuring the 1 1/3 th moment, (when using a D(exp 2/3) dependency on terminal velocity). Instruments that scatter microwaves off of hydrometeors, such as the WSR-880, vertical wind profilers, and microwave disdrometers, measure the 6th moment of the DSD. By projecting a laser onto a target, changes in brightness of the laser spot against the target background during rain, yield a measurement of the DSD 2nd moment, using the Beer-Lambert law. In order to detect the laser attenuation within the 8-bit resolution of most camera image arrays, a minimum path length is required, depending on the intensity of the rainfall rate. For moderate to heavy rainfall, a laser path length of 100 m is sufficient to measure variations in optical extinction using a digital camera. A photo-detector could replace the camera, for automated installations. In order to spatially correlate the 2nd moment measurements to a collocated disdrometer or tipping bucket, the laser's beam path can be reflected multiple times using mirrors to restrict the spatial extent of the measurement. In cases where a disdrometer is not available, complete DSD estimates can be produced by parametric fitting of DSD model to the 2nd moment data in conjunction with tipping bucket data. In cases where a disdrometer is collocated, the laser extinction technique may yield a significant improvement to insitu disdrometer validation and calibration strategies

Lane, John E.↗

Description of Cloud Characterization and Icing Test for a 3D Heated Test Article at the NASA Icing Research Tunnel

This paper describes the cloud characterization and icing tests conducted with a 3D heated test article in Winter/Spring 2022 at the NASA Icing Research Tunnel. The intent is to present analyzed results from these recently conducted tests in a future technical paper. The test article, whose geometry is representative of an inter-compressor duct and strut region of a turbofan engine, has been designed and constructed to study the physics of supercooled water icing and ice crystal icing. The surfaces of the Simulated Inter-compressor Duct Research Model (SIDRM) can be heated to simulate the warm surfaces of the turbofan inter-compressor duct. The test article is instrumented with heaters, heat flux gauges, and thermocouples, while a 3D laser scanner, cameras, a scale to measure ice mass, and other instruments will aid in characterizing the icing behavior. The aim of these tests is to generate ice accretions on the SIDRM test article under well-characterized conditions. To that end, a suite of instruments was utilized to characterize the ice crystal clouds at the test section in a separate test series. The icing measurements collected during the SIDRM model tests will be used to develop and validate 3D computational engine icing tools, such as GlennICE, that predictively assess the onset and growth of ice. One of the goals of the sponsoring NASA project is to develop simulation models and tools that can assist in the design and certification of engines for flight in icing conditions in a cost effective way.

Ice crystal icing↗

Description of Cloud Characterization and Icing Tests for a 3D Heated Test Article at the NASA Icing Research Tunnel

This paper describes the cloud characterization and icing tests conducted with a 3D heated test article in Winter/Spring 2022 at the NASA Icing Research Tunnel. The intent is to present analyzed results from these recently conducted tests in a future technical paper. The test article, whose geometry is representative of an inter-compressor duct and strut region of a turbofan engine, has been designed and constructed to study the physics of supercooled water icing and ice crystal icing. The surfaces of the Simulated Inter-compressor Duct Research Model (SIDRM) can be heated to simulate the warm surfaces of the turbofan inter-compressor duct. The test article is instrumented with heaters, heat flux gauges, and thermocouples, while a 3D laser scanner, cameras, a scale to measure ice mass, and other instruments will aid in characterizing the icing behavior. The aim of these tests is to generate ice accretions on the SIDRM test article under well-characterized conditions. To that end, a suite of instruments was utilized to characterize the ice crystal clouds at the test section in a separate test series. The icing measurements collected during the SIDRM model tests will be used to develop and validate 3D computational engine icing tools, such as GlennICE, that predictively assess the onset and growth of ice. One of the goals of the sponsoring NASA project is to develop simulation models and tools that can assist in the design and certification of engines for flight in icing conditions in a cost effective way.

Ice crystal icing, heated test article, engine ici↗

KAZRARSCL-c0-Cloud Boundaries subset

The KAZR-ARSCL VAP provides cloud boundaries and best-estimate time-height fields of radar moments. The VAP merges corrected, but uncalibrated, KAZR moments from all active radar modes with cloud base and cloud mask observations from the micropulse lidar (MPL), cloud base from the ceilometer, as well information from soundings, rain gauge, and microwave radiometer instruments to produce two data streams, one with best-estimate cloud base and cloud layer boundaries, and another which also includes best-estimate time-height fields of radar moments. This DOI is for the data stream that contain cloud layer boundaries only. Please note that the reflectivity used in this level c0 product is uncalibrated.

54 ENVIRONMENTAL SCIENCES↗

Benchmark Wall Heat Flux Data for a GO2/GH2 Single Element Combustor

Wall heat flux measurements in a 1.5 in. diameter circular cross-section rocket chamber for a uni-element shear coaxial injector element operating on gaseous oxygen (GOz)/gaseous hydrogen (GH,) propellants are presented. The wall heat flux measurements were made using arrays of Gardon type heat flux gauges and coaxial thermocouple instrumentation. Wall heat flux measurements were made for two cases. For the first case, GOZ/GHz oxidizer-rich (O/F=l65) and fuel-rich preburners (O/F=1.09) integrated with the main chamber were utilized to provide vitiated hot fuel and oxidizer to the study shear coaxial injector element. For the second case, the preburners were removed and ambient temperature gaseous oxygen/gaseous hydrogen propellants were supplied to the study injector. Experiments were conducted at four chamber pressures of 750, 600, 450 and 300psia for each case. The overall mixture ratio for the preburner case was 6.6, whereas for the ambient propellant case, the mixture ratio was 6.0. Total propellant flow was nominally 0.27-0.29 Ibm/s for the 750 psia case with flowrates scaled down linearly for lower chamber pressures. The axial heat flux profile results for both the preburner and ambient propellant cases show peak heat flux levels a t axial locations between 2.0 and 3.0 in. from the injector face. The maximum heat flux level was about two times greater for the preburner case. This is attributed to the higher injector fuel-to-oxidizer momentum flux ratio that promotes mixing and higher initial propellant temperature for the preburner case which results in a shorter reaction zone. The axial heat flux profiles were also scaled with respect to the chamber pressure to the power 0.8. The results at the four chamber pressures for both cases collapsed to a single profile indicating that at least to first approximation, the basic fluid dynamic structures in the flow field are pressure independent as long as the chamber/njector/nozzle geometry and injection velocities remain the same.

Marshall, William M.↗

The Dynamics of Shock Dispersion and Interactions in Supersonic Freestreams with Counterflowing Jets

An active flow control concept using counterflowing jets to significantly modify the external flowfields and strongly weaken or disperse the shock-waves of supersonic and hypersonic vehicles to reduce the aerothermal loads and wave drag was investigated. Experiments were conducted in a trisonic blow-down wind-tunnel, complemented by pre-test computational fluid dynamics (CFD) analysis of a 2.6% scale model of Apollo capsule, with and without counterflowing jets, in Mach 3.48 and 4.0 freestreams, to assess the potential aerothermal and aerodynamic benefits of this concept. The model was instrumented with heat flux gauges, thermocouples and pressure taps, and employed five counterflowing jet nozzles (three sonic and other two supersonic with design Mach numbers of 2.44 and 2.94) and nozzle exit diameters ranging from 0.25 to 0.5 inch. Schlieren data show that at low jet flow rates of 0.05 and 0.1lb(sub m)/sec, the interactions result in a long penetration mode (LPM) jet, while the short penetration mode (SPM) jet is observed at flow rates greater than 0.1 lb(sub m)/sec., consistent with the pre-test CFD predictions. For the LPM, the jet appears to be nearly fully-expanded, resulting in a very unsteady and oscillatory flow structure in which the bow shock becomes highly dispersed such that it is no longer discernable. Higher speed camera Schlieren data reveal the shock to be dispersed into striations of compression waves, which suddenly coalesce to a weaker bow shock with a larger standoff distance as the flow rate reached a critical value. The pronounced shock dispersion could significantly impact the aerodynamic performance (L/D) and heat flux reduction of spacecraft in atmospheric entry and re-entry, and could also attenuate the entropy layer in hypersonic blunt body flows. For heat transfer, the results show significant reduction in heat flux, even giving negative heat flux for some of the SPM interactions, indicating that the flow wetting the model is cooling, instead of heating the model, which could significantly impact the requirements and design of thermal protection system. These findings strongly suggest that the application of counterflowing jets as active flow control could have strong impact on supersonic and hypersonic vehicle design and performance.

Daso, Endwell O.↗

Measuring Pressure Has a New Standard

The Force-Balanced Piston Gauge (FPG) tests and calibrates instrumentation operating in the low pressure range. The system provides a traceable, primary calibration standard for measuring pressures in the range of near 0 to 15 kPa (2.2 psi) in both gauge and absolute measurement modes. The hardware combines a large area piston-cylinder with a load cell measuring the force resulting from pressures across the piston. The mass of the piston can be tared out, allowing measurement to start from zero. A pressure higher than the measured pressure, which keeps the piston centered, lubricates an innovative conical gap located between the piston and the cylinder, eliminating the need for piston rotation. A pressure controller based on the control of low gas flow automates the pressure control. DHI markets the FPG as an automated primary standard for very low-gauge and absolute pressures. DHI is selling the FPG to high-end metrology laboratories on a case by case basis, with a full commercial release to follow.

Source record↗

A Dynamic Optimization Technique for Siting the NASA-Clark Atlanta Urban Rain Gauge Network (NCURN)

NASA satellites and ground instruments have indicated that cities like Atlanta, Georgia may create or alter rainfall. Scientists speculate that the urban heat island caused by man-made surfaces in cities impact the heat and wind patterns that form clouds and rainfall. However, more conclusive evidence is required to substantiate findings from satellites. NASA, along with scientists at Clark Atlanta University, are implementing a dense, urban rain gauge network in the metropolitan Atlanta area to support a satellite validation program called Studies of PRecipitation Anomalies from Widespread Urban Landuse (SPRAWL). SPRAWL will be conducted during the summer of 2003 to further identify and understand the impact of urban Atlanta on precipitation variability. The paper provides an. overview of SPRAWL, which represents one of the more comprehensive efforts in recent years to focus exclusively on urban-impacted rainfall. The paper also introduces a novel technique for deploying rain gauges for SPRAWL. The deployment of the dense Atlanta network is unique because it utilizes Geographic Information Systems (GIS) and Decision Support Systems (DSS) to optimize deployment of the rain gauges. These computer aided systems consider access to roads, drainage systems, tree cover, and other factors in guiding the deployment of the gauge network. GIS and DSS also provide decision-makers with additional resources and flexibility to make informed decisions while considering numerous factors. Also, the new Atlanta network and SPRAWL provide a unique opportunity to merge the high-resolution, urban rain gauge network with satellite-derived rainfall products to understand how cities are changing rainfall patterns, and possibly climate.

Shepherd, J. Marshall↗

Analytical and Experimental Studies of Leak Location and Environment Characterization for the International Space Station

The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to detect NH3 coolant leaks in the ISS thermal control system.An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations (directionality).The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lbmyr. to about 1 lbmday. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ramwake flows and structural shadowing within low Earth orbit.

Leak Locator↗

Analytical and Experimental Studies of Leak Location and Environment Characterization for the International Space Station

The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to detect NH3 coolant leaks in the ISS thermal control system. An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations ("directionality"). The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lb-mass/yr. to about 1 lb-mass/day. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ram/wake flows and structural shadowing within low Earth orbit.

000000↗

Instrument for measuring thin-film belt lengths

Instrument consists of base, vernier height gauge, sliding block, and balance-beam assembly with tension weight. Pulley bracket is provided with three pulley mounting holes, 4 inches apart, to accommodate widely different belt lengths. Instrument is accurate to within 0.001 inch and is suitable for commercial production.

Casad, T. A.↗

Stability and Heat Transfer Characteristics of Condensing Films

The overall objective of this research is to investigate the fundamental physics of film condensation in reduced gravity. The condensation of vapor on a cool surface is important in many engineering problems,including spacecraft thermal control and also the behavior of condensate films that may form on the interior surfaces of spacecraft. To examine the effects of body force on condensing films, two different geometries have been tested in the laboratory: (1) a stabilizing gravitational body force (+1g, or condensing surface facing 'upwards') and (2) de-stabilizing gravitational body force (-1g, or 'downwards'). For each geometry, different fluid configurations are employed to help isolate the fluid mechanical and thermal mechanisms operative in condensing films. The fluid configurations are (a) a condensing film, and (b) a non-condensing film with film growth by mass addition by through the plate surface. Condensation experiments are conducted in a test cell containing a cooled copper or brass plate with an exposed diameter of 12.7 cm. The metal surface is polished to allow for double-pass shadowgraph imaging, and the test surface is instrumented with imbedded heat transfer gauges and thermocouples. Representative shadowgraph images of a condensing, unstable (-1g) n-pentane film are shown. The interfacial disturbances associated with the de-stabilizing body force leading to droplet formation and break-off can be clearly seen. The heat transfer coefficient associated with the condensing film is shown. The heat transfer coefficient is seen to initially decrease, consistent with the increased thermal resistance due to layer growth. For sufficiently long time, a steady value of heat transfer is observed, accompanied by continuous droplet formation and break-off. The non-condensing cell consists of a stack of thin stainless steel disks 10 cm in diameter mounted in a brass enclosure. The disks are perforated with a regular pattern of 361 holes each 0.25 mm in diameter. Non-condensing experiments in -1g have employed 50 cSt and 125 cSt silicone oil pumped through the perforated disks at a specified rate by a syringe micropump. The time to droplet break-off and the disturbance wavelengths appear to decrease with increasing pumping rate. The ability to reliably perform multi-point, ultrasonic measurements of the film thickness has been demonstrated. A linear array of eight transducers of 6 mm diameter (with a beam footprint of comparable size) are pulsed with a square-wave signal at a frequency of 5 MHz and a pulse duration of approximately 0.3 s. For thin films (60 m to 2-3 mm in thickness) the layer thickness is determined by frequency analysis, where the received ultrasound pulse is Fourier transformed and the spacing between the peaks in the frequency spectrum is analyzed. For thicker layers (up to at least 1 cm in thickness), time-domain analysis is performed of the received ultrasound pulses to generate directly the layer thickness. A time-trace of the film thickness at a point using a single transducer in the linear array is shown for the case of an unstable (-1g) n-pentane film. The oscillations in film thickness are evidently due to the passage and/or shedding of droplets from the cooled plate surface. The entire transducer array was used to measure the changes in film thickness resulting from the passage of gravity waves generated either by an oscillating wall or the impact of a single droplet on the free surface of a film. The enclosure in both cases was 14 cm square and the transducer spacing was 12 mm. Best results were obtained using as test fluid a mixture of 50% glycerol and 50% water with a fluid layer thickness of 3-5 mm. In both cases the measured wavelengths and wave propagation speeds using the ultrasound technique compared reasonably well with those observed by optical imaging. Additional information can be found in the original extended abstract.

Hermanson, J. C.↗

CFD Code Validation of Wall HeatFluxes for a GO2/GH2 Single Combustor

Computational Fluid Dynamics (CFD) is becoming an important component of injector design in the rocket industry. Injector designers who use CFD in the design process need to understand the accuracy level of the particular code being used for certain aspects of the design. This paper represents a recent effort to demonstrate the accuracy of two CFD codes to calculate the wall heat flux for a single element injector. The FDNS and Loci- CHEM codes currently in use at NASA Marshall Space Flight Center were evaluated. The test case was a single shear coaxial element with gaseous oxygen and hydrogen in a chamber instrumented with coaxial heat flux gauges on the chamber wall down the axis. The data were taken at Penn State University. Measured wall temperatures were used as boundary conditions for the CFD calculations. Calculations were compared to experimental data at chamber pressures of 300,450 600, and 750 psia. The accuracy level of both codes was assessed.

Lin, Jeff↗

Characterization of Radiative Heating Anomaly in High Enthalpy Shock Tunnels

Surface heating measurements in shock tunnels operating at high enthalpy have previously showed anomalously high heating, the mechanisms for which have been the subject of much speculation. However, recent tests in JAXA’s High Enthalpy Shock Tunnel (HIEST) have presented compelling evidence that the heating anomaly is due to radiation from the shock layer, produced by impurities within the shock. This paper describes a test series performed with an Apollo capsule model at angle of attack. The purpose of the test is nominally to study transition over the capsule model at high enthalpy, however data is confounded by the presence of this radiative heating. The model is thus instrumented with thermocouple heat flux gauges and spectrometer-coupled fiber optics to characterize the spectrum of radiative heating simultaneous to the heat flux measurements. Analyses of the spectra, estimates of radiative heating corrections, and comparison to computational fluid dynamic simulation of the shock tunnel are presented.

Brett A Cruden↗

Plans for Ice Crystal Icing Tests Using a 3D Heated Test Article at the NASA Icing Research Tunnel

This presentation describes the plans for ice crystal icing and supercooled water icing tests to be conducted in Fall/Winter 2021 at the NASA Icing Research Tunnel. A test article, whose geometry is representative of an inter-compressor duct and strut region of a turbofan engine, has been designed and fabricated for the study of ice crystal icing physics tests. The Simulated Inter-compressor Duct Research Model (SIDRM) will have the ability to heat surfaces to simulate the warm surfaces of the inter-compressor duct within an engine. The test article is instrumented with heaters, heat flux gauges, thermocouples, and pressure taps to measure icing behavior. The aim of these tests is to generate ice shapes on the SIDRM test article under well-characterized conditions. The results of the testing with the SIDRM model will be used to provide icing physics and validation data for development of the engine icing simulation capabilities in GlennICE, the 3D ice prediction tool. This is intended to be a presentation only, and does not have an accompanying paper.

ice-crystal icing↗

Turbine blade and vane heat flux sensor development, phase 2

The development of heat flux sensors for gas turbine blades and vanes and the demonstration of heat transfer measurement methods are reported. The performance of the heat flux sensors was evaluated in a cylinder in cross flow experiment and compared with two other heat flux measurement methods, the slug calorimeter and a dynamic method based on fluctuating gas and surface temperature. Two cylinders, each instrumented with an embedded thermocouple sensor, a Gardon gauge, and a slug calorimeter, were fabricated. Each sensor type was calibrated using a quartz lamp bank facility. The instrumented cylinders were then tested in an atmospheric pressure combustor rig at conditions up to gas stream temperatures of 1700K and velocities to Mach 0.74. The test data are compared to other measurements and analytical prediction.

Atkinson, W. H.↗

Standard Reference Rainfall Products Used in the TRMM Ground Efforts

The Primary goal of the Tropical Rainfall Measuring Mission (TRMM) Ground Validation (GV) effort is to provide basic validation of satellite-derived precipitation measurements over monthly climatologies. To this end, the Joint Center for Earth Systems Technology (JCET) at the University of Maryland, Baltimore County produces monthly rainfall accumulation reference products for each of the four primary TRMM GV sites. These products, standard methodology for deriving monthly, gauge-adjusted rainfall products, are utilized for each primary site. The monthly rainfall GV reference products are developed in discrete, modular steps with distinct intermediate products. These developmental steps, which will be fully discussed, include: (1) extracting radar data over locations of rain gauges, (2) merging rain gauge and radar data in time and space with user-defined options, (3) quality control of radar and gauge merged data by tracking accumulations from each instrument, and (4) deriving Z_R relationship from quality-controlled merged data over monthly time scales. A summary of all gauge statistics and GV rainfall reference products available for TRMM science users will be presented. Basic reference product results and trends involving monthly accumulation, Z-R relationship, and gauge statistics for primary GV site will be discussed. Finally, the sample impact on monthly rainfall reference products, through varying the time interval between intermediate rainfall accumulations, will be analyzed and presented.

Marks, David A.↗