Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTEGRATION STUDY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The North American Renewable Integration Study (NARIS): A Canadian Perspective

The North American electric power system is undergoing significant change, with renewable resources now contributing more generation than ever before. This transformation is poised to continue given decreasing technology costs and ambitious decarbonization goals at the federal, state, local, corporate, and consumer levels. The North American Renewable Integration Study (NARIS) aims to inform grid planners, utilities, industry, policymakers, and other stakeholders about challenges and opportunities for continental system integration of large amounts of wind, solar, and hydropower to support a low-carbon future grid. The National Renewable Energy Laboratory (NREL) conducted a detailed, continent-wide analysis with planning scenarios of transmission, generation, and demand to reach 80%–92% carbon reductions (from 2005) for the Canadian electric power system, and up to 80% reductions continent-wide. We used a suite of models to study future scenarios and gain insights, including potential impacts on costs, emissions, resource adequacy, and the specific technologies that help enable the transition to a low-carbon grid. Our analysis had a particular focus on the potential role of cooperation among the three North American countries and between regions within each country, and how transmission can support sharing of supply and demand diversity. The NARIS project began in 2016. This report describes a Canadian perspective in coordination with the Natural Resources Canada, and a companion report describes a U.S. perspective in coordination with the U.S. Department of Energy. NARIS was an extension of a previous body of work, including the Western Wind and Solar Integration Study, the Eastern Renewable Generation Integration Study, Interconnections Seam Study, and the Pan Canadian Wind Integration Study. NARIS analyzed the entire continent in detail while studying higher renewable generation than previous studies. The scenarios in NARIS were informed by the goals in the Mid-Century Strategies for the Paris Agreement in each country.

14 SOLAR ENERGY↗

Conceptual Integration Studies of Localized Active Flow Control on the Wing of a Commercial Aircraft

A study of conceptual integration and performance of localized active flow control technology onto wings of short-to-medium-range project passenger airplanes is summarized. Using predicted aerodynamic performance improvement opportunities on a computational fluid dynamics reference aircraft, this paper presents the estimated performance opportunities for conceptual implementation of studied wing localized active flow control technology for low-speed (takeoff and landing) application on a Project Research Aircraft configuration. Using conceptual active flow control systems and structural integration weight penalties for studied concepts, potential relevant net performance benefits can be obtained with reliable active flow control in takeoff and landing. The conceptual integration study identifies potential localized wing active flow control application opportunities for high-lift conditions using energy sources available on modern aircraft. Material benefits are estimated for takeoff and landing configurations for selected localized wing active flow control applications. The study concluded that substantial low-speed Maximum Lift and Lift/Drag related performance improvements may be possible with localized wing high-lift active flow control systems powered by auxiliary power unit, engine bleed, or electrical compressors - with due consideration of integration and weight impacts as well as availability requirements of such systems.

drag reduction↗

Low-Speed Performance Enhancement using Localized Active Flow Control: Integration Study of Localized Active Flow Control on a Performance Reference Aircraft (3/4)

A study of conceptual integration and performance aspects of localized active flow control (AFC) technology onto wings of short-to-medium-range project passenger airplanes is summarized. Using predicted aerodynamic performance improvement opportunities on the CFD Reference Aircraft, estimated benefit opportunities for conceptual implementation of studied wing localized active flow control (AFC) technology for low-speed (take-off and landing) application on a Performance Reference Aircraft configuration are presented. Using conceptual AFC systems and structural integration weight penalties for studied concepts, potential relevant net performance benefits can be obtained with reliable AFC in takeoff and landing. The conceptual integration study identifies potential promising localized wing AFC application opportunities for high-lift conditions using energy sources for modern aircraft. Material benefits are estimated for take-off and landing configurations for selected localized AFC applications. Next steps to refine and expand results of investigated topics, as well as possible other local AFC wing applications, are suggested.

AFC↗

Western Wind and Solar Integration Study Phase 2

The electric grid is a highly complex, interconnected machine, and changing one part of the grid can have consequences elsewhere. Adding wind and solar affects the operation of the other power plants and adding high penetrations can induce cycling of fossil-fueled generators. Cycling leads to wear-and-tear costs and changes in emissions. Phase 2 of the Western Wind and Solar Integration Study(WWSIS-2) evaluated these costs and emissions and simulated grid operations for a year to investigate the detailed impact of wind and solar on the fossil-fueled fleet. This built on Phase 1, one of the largest wind and solar integration studies ever conducted, which examined operational impacts of high wind and solar penetrations in the West.

14 SOLAR ENERGY↗

Liquid rocket booster integration study. Volume 4: Reviews and presentation material

Liquid rocket booster integration study is presented. Volume 4 contains materials presented at the MSFC/JSC/KSC Integrated Reviews and Working Group Sessions, and the Progress Reviews presented to the KSC Study Manager. The following subject areas are covered: initial impact assessment; conflicts with the on-going STS mission; access to the LRB at the PAD; the activation schedule; transition requirements; cost methodology; cost modelling approach; and initial life cycle cost.

Source record↗

Eastern Renewable Generation Integration Study

This presentation provides a high-level overview of the Eastern Renewable Generation Integration Study process, scenarios, tools, goals, and a teaser of preliminary results.

14 SOLAR ENERGY↗

Western Wind and Solar Integration Study Phase 2: Preprint

The Western Wind and Solar Integration Study (WWSIS) investigates the impacts of high penetrations of wind and solar power into the Western Interconnection of the United States. WWSIS2 builds on the Phase 1 study but with far greater refinement in the level of data inputs and production simulation. It considers the differences between wind and solar power on systems operations. It considersmitigation options to accommodate wind and solar when full costs of wear-and-tear and full impacts of emissions rates are taken into account. It determines wear-and-tear costs and emissions impacts. New data sets were created for WWSIS2, and WWSIS1 data sets were refined to improve realism of plant output and forecasts. Four scenarios were defined for WWSIS2 that examine the differences betweenwind and solar and penetration level. Transmission was built out to bring resources to load. Statistical analysis was conducted to investigate wind and solar impacts at timescales ranging from seasonal down to 5 minutes.

14 SOLAR ENERGY↗

Market-Based Indian Grid Integration Study Options: Preprint

The Indian state of Gujarat is forecasting solar and wind generation expansion from 16% to 32% of installed generation capacity by 2015. Some states in India are already experiencing heavy wind power curtailment. Understanding how to integrate variable generation (VG) into the grid is of great interest to local transmission companies and India's Ministry of New and Renewable Energy. This paperdescribes the nature of a market-based integration study and how this approach, while new to Indian grid operation and planning, is necessary to understand how to operate and expand the grid to best accommodate the expansion of VG. Second, it discusses options in defining a study's scope, such as data granularity, generation modeling, and geographic scope. The paper also explores how Gujarat'smethod of grid operation and current system reliability will affect how an integration study can be performed.

14 SOLAR ENERGY↗

Western Wind and Solar Integration Study Phase 3A: Low Levels of Synchronous Generation

The stability of the North American electric power grids under conditions of high penetrations of wind and solar is a significant concern and possible impediment to reaching renewable energy goals. The 33% wind and solar annual energy penetration considered in this study results in substantial changes to the characteristics of the bulk power system. This includes different power flow patterns, different commitment and dispatch of existing synchronous generation, and different dynamic behavior from wind and solar generation. The Western Wind and Solar Integration Study (WWSIS), sponsored by the U.S. Department of Energy, is one of the largest regional solar and wind integration studies to date. In multiple phases, it has explored different aspects of the question: Can we integrate large amounts of wind and solar energy into the electric power system of the West? The work reported here focused on the impact of low levels of synchronous generation on the transient stability performance in one part of the region in which wind generation has displaced synchronous thermal generation under highly stressed, weak system conditions. It is essentially an extension of WWSIS-3. Transient stability, the ability of the power system to maintain synchronism among all elements following disturbances, is a major constraint on operations in many grids, including the western U.S. and Texas systems. These constraints primarily concern the performance of the large-scale bulk power system. But grid-wide stability concerns with high penetrations of wind and solar are still not thoroughly understood. This work focuses on 'traditional' fundamental frequency stability issues, such as maintaining synchronism, frequency, and voltage. The objectives of this study are to better understand the implications of low levels of synchronous generation and a weak grid on overall system performance by: 1) Investigating the Western Interconnection under conditions of both high renewable generation (e.g., wind and solar) and low synchronous generation (e.g., significant coal power plant decommitment or retirement); and 2) Analyzing both the large-scale stability of the Western Interconnection and regional stability issues driven by more geographically dispersed renewable generation interacting with a transmission grid that evolved with large, central station plants at key nodes. As noted above, the work reported here is an extension of the research performed in WWSIS-3.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Short-Term Load Forecasting Error Distributions and Implications for Renewable Integration Studies: Preprint

Load forecasting in the day-ahead timescale is a critical aspect of power system operations that is used in the unit commitment process. It is also an important factor in renewable energy integration studies, where the combination of load and wind or solar forecasting techniques create the net load uncertainty that must be managed by the economic dispatch process or with suitable reserves. An understanding of that load forecasting errors that may be expected in this process can lead to better decisions about the amount of reserves necessary to compensate errors. In this work, we performed a statistical analysis of the day-ahead (and two-day-ahead) load forecasting errors observed in two independent system operators for a one-year period. Comparisons were made with the normal distribution commonly assumed in power system operation simulations used for renewable power integration studies. Further analysis identified time periods when the load is more likely to be under- or overforecast.

17 WIND ENERGY↗

The Eastern Renewable Generation Integration Study: Insights on System Stress: Preprint

The Eastern Renewable Generation Integration Study (ERGIS) explores the operational impacts of the wide spread adoption of wind and solar photovoltaics (PV) resources in North America's Eastern and Quebec Interconnections. We explore the impact of large scale adoption of wind and solar generation on the unit commitment and economic dispatch of the largest coordinated power system in the world by simulating hourly and five-minute operations. Using NREL's high-performance computing capabilities and new methodologies to model operations, we found that the modeled system, as simulated with evolutionary change in 2026, could balance the variability and uncertainty of wind and solar PV at a five-minute level under a variety of conditions. Our simulations achieve instantaneous penetrations that exceed 50% of load while meeting an annual penetration of 30% on an energy basis. The system meets balanced load and supply in all intervals, with modest curtailment, using technologies and practices that are widely available today. However, a variety of the conditions present in these simulations deviate substantially from historical practice. In this work, we analyze potentially stressful system conditions that occur in the simulations and identify opportunities for innovation, regulatory reform, and changes in operating practices that require further analysis to enable the transition to a system with more wind and solar PV.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Western Wind and Solar Integration Study Phase 2 (Executive Summary)

The electric grid is a highly complex, interconnected machine, and changing one part of the grid can have consequences elsewhere. Adding wind and solar affects the operation of the other power plants and adding high penetrations can induce cycling of fossil-fueled generators. Cycling leads to wear-and-tear costs and changes in emissions. Phase 2 of the Western Wind and Solar Integration Study (WWSIS-2) evaluated these costs and emissions and simulated grid operations for a year to investigate the detailed impact of wind and solar on the fossil-fueled fleet. This built on Phase 1, one of the largest wind and solar integration studies ever conducted, which examined operational impacts of high wind and solar penetrations in the West(GE Energy 2010).

14 SOLAR ENERGY↗

The Western Wind and Solar Integration Study Phase 2

The electric grid is a highly complex, interconnected machine, and changing one part of the grid can have consequences elsewhere. Adding wind and solar affects the operation of the other power plants and adding high penetrations can induce cycling of fossil-fueled generators. Cycling leads to wear-and-tear costs and changes in emissions. Phase 2 of the Western Wind and Solar Integration Study (WWSIS-2) evaluated these costs and emissions and simulated grid operations for a year to investigate the detailed impact of wind and solar on the fossil-fueled fleet. This built on Phase 1, one of the largest wind and solar integration studies ever conducted, which examined operational impacts of high wind and solar penetrations in the West(GE Energy 2010).

14 SOLAR ENERGY↗