Optical devices to increase photocathode quantum efficiency
Optical devices for enhancement of semitransparent photocathode quantum efficiency applied to TV camera tubes, image intensifiers and other imaging detectors
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Optical devices for enhancement of semitransparent photocathode quantum efficiency applied to TV camera tubes, image intensifiers and other imaging detectors
Flight qualification of ion thrusters typically requires testing on the order of 10,000 hours. Extensive knowledge of wear mechanisms and rates is necessary to establish design confidence prior to long duration tests. Consequently, real-time erosion rate measurements offer the potential both to reduce development costs and to enhance knowledge of the dependency of component wear on operating conditions. Several previous studies have used laser induced fluorescence (LIF) to measure real-time, in situ erosion rates of ion thruster accelerator grids. Those studies provided only relative measurements of the erosion rate. In the present investigation, a molybdenum tube was resistively heated such that the evaporation rate yielded densities within the tube on the order of those expected from accelerator grid erosion. A pulsed UV laser was used to pump the ground state molybdenum at 345.64nm, and the non-resonant fluorescence at 550-nm was collected using a bandpass filter and a photomultiplier tube or intensified CCD array. The sensitivity of the fluorescence was evaluated to determine the limitations of the calibration technique. The suitability of the diagnostic calibration technique was assessed for application to ion engine erosion rate measurements.
Definitions, test schemes, and analyses used to provide variable magnification in the image section of the television sensor for large space telescopes are outlined. Experimental results show a definite form of magnetic field distribution is necessary to achieve magnification in the range 3X to 4X. Coil systems to establish the required field shapes were built, and both image intensifiers and camera tubes were operated at high magnification. The experiments confirm that such operation is practical and can provide satisfactory image quality. The main problem with such a system was identified as heating of the photocathode due to concentration of coil power dissipation in that vicinity. Suggestions for overcoming this disadvantage are included.
Developing electrostatic image inverters, image intensifiers, and camera tubes
Papers are presented on the picosecond electronic framing camera, photogrammetric techniques using high-speed cineradiography, picosecond semiconductor lasers for characterizing high-speed image shutters, the measurement of dynamic strain by high-speed moire photography, the fast framing camera with independent frame adjustments, design considerations for a data recording system, and nanosecond optical shutters. Consideration is given to boundary-layer transition detectors, holographic imaging, laser holographic interferometry in wind tunnels, heterodyne holographic interferometry, a multispectral video imaging and analysis system, a gated intensified camera, a charge-injection-device profile camera, a gated silicon-intensified-target streak tube and nanosecond-gated photoemissive shutter tubes. Topics discussed include high time-space resolved photography of lasers, time-resolved X-ray spectrographic instrumentation for laser studies, a time-resolving X-ray spectrometer, a femtosecond streak camera, streak tubes and cameras, and a short pulse X-ray diagnostic development facility.
Specially built intensified CCD (ICCD) detector tubes were purchased and the performance of the electron bombardment process was investigated. In addition to studying the signal characteristics of the photoevents, there was interest in demonstrating that back-illuminated chips were not susceptible to radiation damage to their clocking electrodes. How to perform a centroid analysis for a 2-dimensional Gaussian distribution of charge is described. Measurement of the projection (along columns or rows) of the average charge spread profile is discussed. The development and flight of the Interstellar Medium Absorption Profile Spectrograph (IMAPS) is discussed.
High-spatial-resolution OH planar laser-induced fluorescence was measured for a premixed ethylene-air turbulent flame in an electrically-heated Mach 2 continuous-flow facility (University of Virginia Supersonic Combustion Facility, Configuration E.) The facility comprised a Mach 2 nozzle, an isolator with flush-wall fuel injectors, a combustor with optical access, and an extender. The flame was anchored at a cavity flameholder with a backward-facing step of height 9 mm. The temperature-insensitive Q1(8) transition of OH was excited using laser light of wavelength 283.55 nm. A spatial filter was used to create a laser sheet approximately 25 microns thick based on full-width at half maximum (FWHM). Extension tubes increased the magnification of an intensified camera system, achieving in-plane resolution of 40 microns based on a 50% modulation transfer function (MTF). The facility was tested with total temperature 1200 K, total pressure 300 kPa, local fuel/air equivalence ratios of approximately 0.4, and local Mach number of approximately 0.73 in the combustor. A test case with reduced total temperature and another with reduced equivalence ratio were also tested. PLIF images were acquired along a streamwise plane bisecting the cavity flameholder, from the backward facing step to 120 mm downstream of the step. The smallest observed features in the flow had width of approximately 110 microns. Flame surface density was calculated for OH PLIF images.
Future instruments for the 100-10,000 A UV-wavelength region will require detectors with greater quantum efficiency, smaller picture elements, a greater wavelength range, and greater active area than those currently available. After assessing the development status and performance characteristics of vidicons, image tubes, electronographic cameras, digicons, silicon arrays and microchannel plate intensifiers presently employed by astronomical spacecraft, attention is given to such next-generation detectors as the Mosaicked Optical Self-scanned Array Imaging Camera, which consists of a photocathode deposited on the input side of a microchannel plate intensifier. The problems posed by the signal processing and data analysis requirements of the devices foreseen for the 21st century are noted.
The results are presented of a program to design, fabricate, and test CCD arrays suitable for operation in an electron-bombarded mode. These intensified charge coupled devices have potential application to astronomy as photon-counting arrays. The objectives of this program were to deliver arrays of 250 lines of 400 pixels each and some associated electronics. Some arrays were delivered on tube-compatible headers and some were delivered after incorporation in vacuum tubes. Delivery of these devices required considerable improvements to be made in the processing associated with intensified operation. These improvements resulted in a high yield in the thinning process, reproducible results in the accumulation process, elimination of a dark current source in the accumulation process, solution of a number of header related problems, and the identification of a remaining major source of dark current. Two systematic failure modes were identified and protective measures established. The effects of tube processing on the arrays in the delivered ICCDs were determined and are reported along with the characterization data on the arrays.
The atmospheric emissions photometric imaging experiment was flown on Spacelab 1 to study faint natural and artificial atmospheric emission phenomena. The instrument imaged optical emission in the region 2000 to 7500 angstroms with a television system consisting of two optical channels, one wide-angle and one telephoto. A third optical channel imaged onto the photocathode of a microchannel plate photomultiplier tube that has 100 discrete anodes. A hand-held image intensifier camera with an objective grating permitted spectral analysis of the earth's airglow and the Shuttle glow. Preliminary data show magnesium ion emission features in the lower ionosphere as well as the spacecraft glow spectrum.
A multichannel detector system is described in which the positions of individual photon events in a high-gain image intensifier are decoded in the output of a video detector. The high-gain intensifier consists of a pair of three-stage electrostatic image-tube assemblies each containing three fiber-optically-coupled tubes potted in a rugged package with an internal high-voltage supply. Operation of the electrooptical system is discussed along with the pulse-detection process and the operation of the spectrograph in which the image-tube assembly is mounted. It is noted that the spectrometer detects 1.0 count/sec per A for an object of magnitude 13.0 at the peak of its response in the visual band when no light is lost on the slit, that a 10% coincidence correction is reached at an overall count rate of 860 per sec, and that the response follows an exponential law up to count rates of about 4000 per sec. The measured spectrum of the Seyfert galaxy NGC 5548 is provided as an example of the raw data produced by the instrument on a 1.5 meter telescope.
A description is presented of a television detector system which has been designed to accommodate a wide range of applications. It is currently being developed for use in X-ray diffraction, X-ray astrophysics, and electron microscopy, but it is also well suited for astronomical observations. The image can be integrated in a large, high-speed memory system, in the memory of a computer system, or the target of the TV tube or CCD array. The detector system consists of a continuously scanned, intensified SIT vidicon with scan and processing electronics which generate a digital image that is integrated in the detector memory. Attention is given to details regarding the camera system, scan control and image processing electronics, the memory system, and aspects of detector performance.
X-ray intensifying screen may make possible radiographic procedures where detection speed and X-ray tube power have been the limiting factors. Device will reduce total population exposure to harmful radiation in the United States.
Various beam imaging and/or sheet forming optics delivered light at 1064 nm from a pulsed Nd:YAG laser for use either as a beam of 3 mm radius or as a laser sheet. Imaging measurements were performed with a grated intensified array camera equipped with an ultraviolet f4.5 lens and a 40 mm extension tube. Point measurements were performed using an ultraviolet 250 mm focal length lens to collect and focus the laser induced incandescence (LII) signal into a 1 meter long quartz optical fiber which directed the LII signal to a 1/4 meter monochromator. An aperture preceding the lens restricted the signal collection region to 1 cm along the laser beam at the center of the gravimetric chimney. Signals from the PMT were processed by a boxcar integrator whereas the images were captured digitally using a frame-grabber with 16 MByte of on-board memory. Both 'point' and planar measurements were made with detector gates of 250 ns to minimize possible morphology bias in collection of the LII signal. Additionally, the imaging measurements were performed with broadband spectral collection of the LII signal to maximize the signal and again minimize any potential effects of morphology dependent heating and/or cooling rates. Digital delay generators controlled the firing of he laser, detector gates and data acquisition. Neutral density filters were used for both sets of measurements to maintain signal levels within linear dynamic ranges of the detectors, the range being determined prior to experiments.
The Space Telescope, planned for orbiting in the early 1980s, is described, with emphasis on its electro-optical image sensing capability. Relative advantages of image tubes and solid state arrays as image detectors are summarized; image tube technology is well characterized, but preference may be given to a more versatile tandem solid state array consisting of one module with high silicon response covering most of the spectrum, and a second intensified array with ultraviolet sensitivity and low noise readout. The classical 'photoelectron noise limit' calculation is reviewed, and a detailed calculation of sensitivity limits adaptable to analysis of image tube or solid state array detectors is also given. In particular, characteristics of a filter to optimize the signal to noise ratio is determined. Typical sensitivity calculations for an image tube detector show that with an exposure of one orbital night (approximately 2000 seconds), 10% photometry may be done to a low limit of visual magnitude.
Intensified CCDs (ICCDs) were built and operated. These ICCDs were electrostatically and magnetically-focussed image tubes which use CCDs as anodes. The ICCDs detected single photoelectrons, and have electron gain very near that which was predicted. The first single-pixel pulse-height distributions were presented, and the leakage current was shown to increase as a function of photoelectron irradiation. The advantages and disadvantages of front- and rear-illuminated designs were discussed in light of differing applications requirements.
Three different types of X-ray fluoroscopic TV chains were investigated: two standard clinical units, one with a vidicon camera tube, the other with a plumbicon camera tube; and the third was a large flat-screen unit. In each an X-ray beam generated at 100 kVp was passed through 10 cm of H2O before aluminum absorbers of varying thickness were introduced. Five video recordings were made at each absorber thickness. The video image was digitized directly from the disk recording and quantized into 128 gray levels. The five recordings were averaged on a point-to-point basis, and the central 900 averaged points were again averaged to yield a value for the gray level assigned to each particular image. This 30 by 30 matrix of points corresponds to input screen areas of 29, 8.2, and 3.6 sq cm for the three units investigated.
Actual and projected performance of an intensified charge coupled device (ICCD) to be used as a photon counting imager will be presented. Effects of tube processing on such important CCD parameters as charge transfer efficiency and dark current are discussed.