Error analysis of a satellite interferometer navigation system

An error analysis is performed for a global positioning and navigation system which relies on an orthogonal array of interferometry baselines on board a geostationary satellite. The error analysis involves linearization of a mathematical model which is based on the relationship between the measured phase differences, the known transmitter positions, and other systematic error parameters. According to the error analysis, position accuracy is critically dependent on the baseline length and the magnitude of the random component of the measuring errors. It is shown that a satellite interferometry system with baselines of about 50 m can yield position accuracies on the order of 20 m.

Gopalapillai, G. S.

Observation of Upper and Middle Tropospheric Clouds

The goal of this research has been to identify and describe the properties of climatically important cloud systems critically important to understanding their effects upon satellite remote sensing and the global climate. These goals have been pursued along several different but complementary lines of investigation: the design, construction, testing and application of instrumentation; the collection of data sets during Intensive Field Observation periods; the reduction and analysis of data collected during IFO's; and completion of research projects specifically designed to address important and timely research objectives. In the first year covered by this research proposal, three papers were authored in the refereed literature which reported completed analyses of FIRE 1 IFO studies initiated under the previous NASA funding of this topic area. microphysical and radiative properties of marine stratocumulus cloud systems deduced from tethered balloon observations were reported from the San Nicolas Island site of the first FIRE marine stratocumulus experiment. Likewise, in situ observations of radiation and dynamic properties of a cirrus cloud layer were reported from first FIRE cirrus IFO based from Madison, Wisconsin. In addition, application techniques were under development for monitoring cirrus cloud systems using a 403 MHz Doppler wind profiler system adapted with a RASS (Radio Acoustic Sounding System) and an infrared interferometer system; these instrument systems were used in subsequent deployments for the FIRE 2 Parsons, Kansas and FIRE 2 Porto Santo, ASTEX expeditions. In November 1991 and in June 1992, these two systems along with a complete complement of surface radiation and meteorology measurements were deployed to the two sites noted above as anchor points for the respective IFO'S. Subsequent research activity concentrated on the interpretation and integration of the IFO analyses in the context of the radiative properties of cloud systems and our ability to remotely observe radiative, thermodynamic and dynamic properties of these cloud systems.

Cox, Stephen K.

NASA geodetic applications of the Mark 3 VLBI system

The Mark 3 very long baseline interferometer system was used in monitoring the following geodetic phenomena: the regional deformation and strain accumulation related to large earthquakes in the plate boundary region of the western United States; contemporary relative plate tectonic motions of the North American, Pacific, South American, Eurasian, and Australian Plates; the internal deformation of continental and oceanic lithospheric plates with particular emphasis on North America and the Pacific; the rotational dynamics of the Earth and their possible correlation to earthquakes, plate motions, and other geophysical phenomena; and motions and deformation occurring in regions of high earthquake activity.

Coates, R.

An interferometer tracking radar system

Fine tuning acquisition and tracking interferometer radar system uses a first antenna array of at least three receiving antennas. Array includes a reference antenna, a coarse tuning antenna, and a fine tuning antenna aligned on a receiving axis. Short range rendezvous system provides increased position accuracy.

Broderick, R. F.

A real time interferometry system for unsteady flow measurements

A simple real-time interferometer system was developed for use in dynamic stall and other unsteady flow research at compressible flow speeds. A conventional schlieren system was modified to operate as a point diffraction interferometer. The implementation of this interferometer is discussed, and results of trials with different point diffractors are presented in this paper. The performance of the interferometer under various flow conditions was investigated. Results are presented which show the effects of the interferometer parameters such as pinhole size and pinhole-plate optical density on the performance of the system.

Brock, N. J.

Operating manual holographic interferometry system for 2 x 2 foot transonic wind tunnel

A holographic interferometer system was installed in a 2X2 foot transonic wind tunnel. The system incorporates a modern, 10 pps, Nd:YAG pulsed laser which provides reliable operation and is easy to align. The spatial filtering requirements of the unstable resonator beam are described as well as the integration of the system into the existing Schieren system. A two plate holographic interferometer is used to reconstruct flow field data. For static wind tunnel models the single exposure holograms are recorded in the usual manner; however, for dynamic models such as oscillating airfoils, synchronous laser hologram recording is used.

Craig, J. E.

Nd:YAG holographic interferometer for aerodynamic research

A holographic interferometer system has been installed in the NASA Ames 2- by 2-Foot Transonic Wind Tunnel. The system incorporates a modern 10 pps, Nd:YAG pulsed laser which provides reliable operation and is easy to align. The spatial filtering requirements of the unstable resonator beam are described, as well as the integration of the system into the existing schlieren system. A two-plate holographic interferometer is used to reconstruct flow field data. For static wind tunnel models, the single exposure holograms are recorded in the usual manner; however, for dynamic models such as oscillating airfoils, synchronous laser hologram recording is used.

Craig, J. E.

Interferometer Development for Study of Interactions between Flames on Parallel Solid Surfaces

The interactions between flames spreading over parallel solid sheets of paper are being studied in normal gravity and in microgravity. This geometry provides interesting opportunities to study the interaction of radiative and diffusive transport mechanisms on the spread process. These transport mechanisms are changed when the flame interacts with other flames. Most practical heterogeneous combustion processes involve interacting discrete burning fuel elements, consequently, the study of these interactions is of practical significance. Owing largely to this practical importance, flame interactions have been an area of active research, however microgravity research has been largely limited to droplets. Consideration of flame spread over parallel solid surfaces has been limited to 1-g studies. To study the conductive transport in these flames, an interferometer system has been developed for use in the drop tower. The system takes advantage of a single beam interferometer: Point Diffraction Interferometry (PDI) which uses a portion of the light through the test section to provide the reference beam. Like other interferometric and Schlieren systems, it is a line of sight measurement and is subject to the usual edge and concentration effects. The advantage over Schlieren and shearing interferometry systems is that the fringes are lines of constant index of refraction rather than of its gradient so the images are more readily interpreted. The disadvantage is that it is less able to accommodate a range of temperature gradients.

Goldmeer, J. S.

Mars Observer Propulsion and Pyrotechnics Corrective Actions Test Program Status-1999

An extensive propulsion and pyrotechnic test program has been in progress at the NASA White Sands Test Facility since 1995. This program created the capabilities to: accurately measure and characterize pyrovalve combustion product blow-by into propellant systems; characterize valve operation using a Velocity Interferometer System for Any Reflector (VISAR); and evaluate hydrazine and monomethylhydrazine thermal decomposition initiated by blow-by. These capabilities were further utilized and refined this year. Low blow-by pyrovalves manufactured by Conax Florida Corporation continued to be evaluated as a potential corrective measure for blow-by induced propellant explosions. Development and testing of various advanced pyrovalves and investigation of explosion mechanisms also continued. Current and near-term testing includes: evaluation of 3/8 in. Conax pyrovalves and other commercially available valves; development and testing of advanced pyrovalve subcomponent technologies including a zero blow-by pyrovalve ram, composite overwrapped ram cylinder, and a zero particulate generating poppet; investigation of non-destructive evaluation techniques to evaluate pyrovalve ram seals; and testing and modeling of pyrotechnically induced explosive hydrazine decomposition. Evaluation of 3/8 in. Conax valves will include operational margin testing to be accomplished at NASA Langley Research Center. The test program also seeks to compile and format significant amounts of data from this and other pyrovalve test programs to generate a pyrovalve applications handbook. The handbook will facilitate formation of standards that ensure safe spacecraft applications. Current data and future plans are discussed, and community interaction is encouraged.

Saulsberry, Regor

Measurement Via Optical Near-Nulling and Subaperture Stitching

A subaperture stitching interferometer system provides near-nulling of a subaperture wavefront reflected from an object of interest over a portion of a surface of the object. A variable optical element located in the radiation path adjustably provides near-nulling to facilitate stitching of subaperture interferograms, creating an interferogram representative of the entire surface of interest. This enables testing of aspheric surfaces without null optics customized for each surface prescription. The surface shapes of objects such as lenses and other precision components are often measured with interferometry. However, interferometers have a limited capture range, and thus the test wavefront cannot be too different from the reference or the interference cannot be analyzed. Furthermore, the performance of the interferometer is usually best when the test and reference wavefronts are nearly identical (referred to as a null condition). Thus, it is necessary when performing such measurements to correct for known variations in shape to ensure that unintended variations are within the capture range of the interferometer and accurately measured. This invention is a system for nearnulling within a subaperture stitching interferometer, although in principle, the concept can be employed by wavefront measuring gauges other than interferometers. The system employs a light source for providing coherent radiation of a subaperture extent. An object of interest is placed to modify the radiation (e.g., to reflect or pass the radiation), and a variable optical element is located to interact with, and nearly null, the affected radiation. A detector or imaging device is situated to obtain interference patterns in the modified radiation. Multiple subaperture interferograms are taken and are stitched, or joined, to provide an interferogram representative of the entire surface of the object of interest. The primary aspect of the invention is the use of adjustable corrective optics in the context of subaperture stitching near-nulling interferometry, wherein a complex surface is analyzed via multiple, separate, overlapping interferograms. For complex surfaces, the problem of managing the identification and placement of corrective optics becomes even more pronounced, to the extent that in most cases the null corrector optics are specific to the particular asphere prescription and no others (i.e. another asphere requires completely different null correction optics). In principle, the near-nulling technique does not require subaperture stitching at all. Building a near-null system that is practically useful relies on two key features: simplicity and universality. If the system is too complex, it will be difficult to calibrate and model its manufacturing errors, rendering it useless as a precision metrology tool and/or prohibitively expensive. If the system is not applicable to a wide range of test parts, then it does not provide significant value over conventional null-correction technology. Subaperture stitching enables simpler and more universal near-null systems to be effective, because a fraction of a surface is necessarily less complex than the whole surface (excepting the extreme case of a fractal surface description). The technique of near-nulling can significantly enhance aspheric subaperture stitching capability by allowing the interferometer to capture a wider range of aspheres. More over, subaperture stitching is essential to a truly effective near-nulling system, since looking at a fraction of the surface keeps the wavefront complexity within the capability of a relatively simple nearnull apparatus. Furthermore, by reducing the subaperture size, the complexity of the measured wavefront can be reduced until it is within the capability of the near-null design.

Forbes, Greg

Polarized-interferometer feasibility study

The feasibility of using a polarized-interferometer system as a rendezvous and docking sensor for two cooperating spacecraft was studied. The polarized interferometer is a radio frequency system for long range, real time determination of relative position and attitude. Range is determined by round trip signal timing. Direction is determined by radio interferometry. Relative roll is determined from signal polarization. Each spacecraft is equipped with a transponder and an antenna array. The antenna arrays consist of four crossed dipoles that can transmit or receive either circularly or linearly polarized signals. The active spacecraft is equipped with a sophisticated transponder and makes all measurements. The transponder on the passive spacecraft is a relatively simple repeater. An initialization algorithm is developed to estimate position and attitude without any a priori information. A tracking algorithm based upon minimum variance linear estimators is also developed. Techniques to simplify the transponder on the passive spacecraft are investigated and a suitable configuration is determined. A multiple carrier CW signal format is selected. The dependence of range accuracy and ambiguity resolution error probability are derived and used to design a candidate system. The validity of the design and the feasibility of the polarized interferometer concept are verified by simulation.

Raab, F. H.

Truncated nonlinear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input port that receives an optical beam and a non-linear amplifier that amplifies the optical beam with a pump beam and renders a probe beam and a conjugate beam. The system's local oscillators have a relationship with the respective beams. The system includes a sensor that transduces an input with the probe beam and the conjugate beam or their respective local oscillators. It includes one or more phase-sensitive detectors that detect a phase modulation between the respective local oscillators and the probe beam and the conjugate beam. Output from the phase-sensitive-detectors is based on the detected phase modulation. The phase-sensor-detectors include measurement circuitry that measure the phase signals. The measurement is the sum or difference of the phase signals in which the measured combination exhibit a quantum noise reduction in an intensity difference or a phase sum or an amplitude difference quadrature.

Pooser, Raphael C.

Theoferometer for High Accuracy Optical Alignment and Metrology

The accurate measurement of the orientation of optical parts and systems is a pressing problem for upcoming space missions, such as stellar interferometers, requiring the knowledge and maintenance of positions to the sub-arcsecond level. Theodolites, the devices commonly used to make these measurements, cannot provide the needed level of accuracy. This paper describes the design, construction, and testing of an interferometer system to fill the widening gap between future requirements and current capabilities. A Twyman-Green interferometer mounted on a 2 degree of freedom rotation stage is able to obtain sub-arcsecond, gravity-referenced tilt measurements of a sample alignment cube. Dubbed a 'theoferometer,' this device offers greater ease-of-use, accuracy, and repeatability than conventional methods, making it a suitable 21st-century replacement for the theodolite.

Toland, Ronald

Microwave interferometer controls cutting depth of plastics

Microwave interferometer system controls the cutting of plastic materials to a prescribed depth. The interferometer is mounted on a carriage with a spindle and cutting tool. A cross slide, mounted on the carriage, allows the interferometer and cutter to move toward or away from the plastic workpiece.

Heisman, R. M.