Corrosion Behavior of Wire Electrical Discharge Machined Surfaces of P91 Steel

The extensive usage of P91 steel in certain reactor components requires its precision fabrication by wire electrical discharge machining (WEDM). The WEDM cut surfaces consist of primarily re-melted and solidified layer (recast layer) of 2-8 µm. The recast layer is a result of fast removal of heat by unaffected metallic substrate and dielectric medium leading to rapid cooling. The WEDM surface is expected to affect the component performance in terms of its corrosion properties. The microstructural changes taking place due to EDM cutting of P91 steel bring about a drastic change in the electrochemical response of surface as compared to that for bulk P91 steel. The surface microstructure is shown to alter the passivation behavior and resistance to localized corrosion. Electrochemical polarization studies were done to evaluate passivation, pitting and intergranular corrosion (IGC) behavior and field emission gun—scanning electron microscopy was used for microstructural characterization of P91 steel surfaces. The passivation behavior for P91 steel WEDM cut surfaces was better than that for diamond polished surface. But pitting corrosion resistance decreased for the P91 steel WEDM surface which is a result of inhomogeneities in the microstructure of recast layer. The IGC resistance though increased due to the decreased grain size in the surface layer.

36 MATERIALS SCIENCE↗

Corrosion Behavior of Candidate Materials Used for Urea Hydrolysis Equipment in Coal-Fired Selective Catalytic Reduction Units

Corrosion tests were performed in the laboratory in order to assess the corrosion resistance of candidate materials used in urea hydrolysis equipment. The materials to be evaluated were exposed at 145 °C for 1000 h. Alloys 316L, 316L Mod., HR3C, Inconel 718, and TC4 were evaluated. Additionally, aluminide and chromate coatings applied to a 316L substrate were examined. After exposure, the mass changes in the test samples were measured by a discontinuous weighing method, and the morphologies, compositions, and phases of the corrosion products were analyzed using scanning electron microscopy, energy-dispersive spectroscopy, and x-ray diffraction. Results indicated that continuous pitting and dissolution corrosion were the main failure modes for 316L stainless steel. 316L Mod. and HR3C alloy showed better corrosion resistance than 316L due to their relatively high Cr contents, but HR3C exhibited a strong tendency toward intergranular corrosion. Inconel 718, TC4, and aluminide and chromate coating samples showed similar corrosion processes: only depositions formed by hydrothermal reactions were observed. Based on these results, a possible corrosion process in the urea hydrolysis environment was discussed for these candidate materials and questions to be clarified were proposed.

36 MATERIALS SCIENCE↗

Atomistic Mechanisms of Stress-Dependent Molten Salt Corrosion in NiCr Alloys

Ni-based structural alloys in molten salt environments often experience simultaneous mechanical loading and corrosive attack, yet the mechanisms governing stress-corrosion interactions remain unclear. Prior studies largely emphasize tensile stress, while the role of compressive stress has received limited attention. Here, reactive molecular dynamics simulations are used to investigate the coupled effects of applied strain and corrosion in Ni 0.75 Cr 0.25 exposed to molten FLiNaK at 800 °C. A Σ5(210) grain boundary model is subjected to tensile (+4%) to compressive (−4%) uniaxial strains, and corrosion behavior is evaluated through fluorine adsorption, charge redistribution, and grain boundary evolution. Tensile strain accelerates intergranular corrosion susceptibility by reducing local atomic packing through elastic dilation and increasing excess free volume at the grain boundary, which enhances atomic mobility and salt infiltration. In contrast, compressive strain can suppress corrosion by promoting the formation of a ridge-like surface layer along the grain boundary, limiting salt access to the underlying alloy. These results provide atomistic insight into how stress states influence grain boundary corrosion in molten salts.

36 - MATERIALS SCIENCE↗

Mechanical Properties and Corrosion Behavior of Spray-Formed 7075 Alloy with One-Stage Aging

The mechanical properties, corrosion resistance and microstructure of the spray-formed 7075 alloy after one-stage aging treatments were studied by using a tensile tester, hardness tester, slow strain rate test, electrical test, intergranular corrosion test, electrochemical corrosion test, scanning electron microscope and transmission electron microscope. The results show that the strength and hardness of the alloy have double peaks with the one-stage aging treatments. With aging at 120 °C for 24 h (first peak), abundant tiny η′ phases and η phases precipitate in the matrix. The tensile strength of the alloy increases to 760 MPa, and the elongation is 4.8%. After aging at 120 °C for 132 h (second peak), blocky η phases appear. The tensile strength and elongation of the alloy are 757 MPa and 5.9%, respectively. The grain boundary precipitates dissociate, and the precipitate-free zones are widened. The corrosion resistance of the alloy increases.

36 MATERIALS SCIENCE↗

Microstructure and Corrosion Properties of Laser-Welded SAF 2507 Super Duplex Stainless Steel Joints

SAF 2507 super duplex stainless steel has been welded using laser beam (LB) welding and laser/gas metal arc hybrid (LGH) welding processes. The pitting and intergranular corrosion properties of the welding joints have been tested using electrochemical testing and microstructure observations. The volume fraction of the ferrite phase reaches 70% in the weld zone of the LB welding joint, while the volume fraction of the ferrite phase is 60% for the welding joint of LGH due to the introduction of Ni from welding wire. The pitting corrosion resistance of the welding joint for LB is better than that of LGH. The pitting corrosion is easily conceived in the heat-affected zone (HAZ) because of the formation of Cr{sub 2}N in the HAZ during welding.

36 MATERIALS SCIENCE↗

Study on Corrosion Behavior of 7075 Aluminum Alloy with Retrogression and Reaging Using Taguchi Method

The corrosion resistance and mechanical properties of 7075 aluminum alloy are improved by retrogression and reaging (RRA) heat treatment. Due to the complex process of RRA heat treatment, a Taguchi L25 orthogonal array is designed to optimize the process parameters of RRA heat treatment. In this work, analysis of variance was performed to find out the significant heat treatment parameters. Microstructure, mechanical properties, intergranular corrosion, exfoliation corrosion and stress corrosion cracking behaviors of 7075 aluminum alloy after RRA heat treatment were investigated by tensile test, slow strain rate test, transmission electron microscope and scanning electron microscope. Results showed that the RRA treatment involving preaging at 120 °C for 16 h, retrogression at 200 °C for 8 min and reaging at 120 °C for 24 h resulted in a desired combination of corrosion resistance and mechanical properties.

36 MATERIALS SCIENCE↗

Effect of Low-Temperature Sensitization on the Corrosion Behavior of AISI Type 304L SS Weld Metal in Simulated Groundwater

The manuscript presents the investigations carried out on the effect of low-temperature sensitization (LTS) of 304L SS weld metal on its corrosion behavior in simulated groundwater, for its application as a canister material for long-term storage of nuclear vitrified high-level waste in geological repositories. AISI type 304L SS weld pad was fabricated by multipass gas tungsten arc welding process using 308L SS filler wire. The as-welded specimens were subsequently subjected to carbide nucleation and further to LTS at 500 °C for 11 days to simulate a temperature of 300 °C for 100-year life of the canister in geological repositories. Delta ferrite (δ-ferrite) content of the 304L SS weld metal substantially decreased on carbide nucleation treatment and further only a marginal decrease occurred on LTS treatment. The microstructure of the as-welded consisted of δ-ferrite as a minor phase distributed in austenite matrix. The δ-ferrite appeared fragmented in the carbide-nucleated and LTS-treated weld metal. The degree of sensitization measured by double-loop electrochemical potentokinetic reactivation method indicated an increase in carbide nucleation treatment when compared to the as-welded specimens, and further increase occurred on LTS treatment. Potentiodynamic anodic polarization investigations in simulated groundwater indicated a substantial decrease in the localized corrosion resistance of the carbide-nucleated and LTS 304L SS weld metals, when compared to the as-welded specimens. Post-experimental micrographs indicated pitting as the primary mode of attack in the as-welded, while pitting and intergranular corrosion (IGC) occurred in the carbide-nucleated weld metal. LTS-treated weld metal predominantly underwent IGC attack. The decrease in the localized corrosion resistance of the weld metal after LTS treatment was found to have a direct correlation with the degree of sensitization and the weld microstructure. The results are detailed in the manuscript.

36 MATERIALS SCIENCE↗

Characterization of texture and grain boundary character distributions of selective laser melted Inconel 625 alloy

Highlights: • <110> texture along layer build direction was generated in as-SLMed Inconel 625. • The stress relief process dominates texture and GBCD evolution. • SLMed IN 625 alloy can be GBEed via suitable post annealing. - Abstract: Select laser melting (SLM) is one of the practical metal additive manufacturing processes to fabricate complex structures. The inhomogeneous microstructure and high residual stress are typically resulted from a non-uniform melting and rapid solidification during a SLM process, which has the significant impact on part dimensional instability, corrosion resistance, and mechanical properties. The bulk of current research is limited to the general characterization of grain size, texture, and mechanical properties. However, grain boundary character distribution (GBCD) and its relationship with texture are yet to be understood. This study has shown that the preferred <110> along building direction and <100> along laser scanning direction were produced. The high density of low angle grain boundary (LAGB) can be an indicator of residual stress levels in the as-SLMed samples. The newly-developed ∑3, ∑9 and ∑27 grain boundaries were heavily populated, and the cluster of grains interfaced by ∑3{sup n} (n = 0, 1, 2…) was introduced at the expense of LAGB only at high recrystallization annealing (1150°C or over). The research results suggest that GBCD optimization be possible in the SLMed Inconel 625 alloy via suitable post annealing, which allows improving intergranular corrosion resistance and enhancing mechanical properties.

36 MATERIALS SCIENCE↗

Microstructure and in-service degradation of baffle former bolts – in-core components of light water reactors

This report presents a microstructure evaluation of the baffle former bolt, a commercial pressurized water reactor component. Using SEM, EDS, and EBSD analysis the material was identified as AISI 316 steel with an annealed austenite microstructure. Findings include abnormal grain growth in a fraction of the grains and the absence of retained ferrite. Notable observations include an overlapping of pre- and post-irradiation deformation, including defect-free channel formation as an active deformation mechanism in the near-surface layer of BFB. Specimen surfaces, exposed to high-temperature, high-pressure water, exhibited signs of in-service corrosion degradation. EBSD and EDS analyses highlighted intergranular corrosion, possible grain boundary oxidation with depths less than 3 µm, and, unexpectedly, short cracks filled with Cr-rich oxides measuring around 5-6 µm. The presence of defect-free channels from EBSD data suggests episodes of high mechanical stresses during service. The specimens provide a potentially unique insight into the in-service degradation of NPP components, strain localization, and crack initiation processes. An intact corrosion layer reveals a complex component's in-service history. Further research is underway for a detailed analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensitization of 316L Stainless Steel made by Laser Powder Bed Fusion Additive Manufacturing

Additively manufactured (AM) 316L stainless steel (SS) manufactured by laser powder bed fusion (L-PBF) and wrought 316L SS were subjected to sensitization heat treatments at 700°C up to 100 h. Using two evaluation methods, double-loop electrochemical potentiokinetic reactivation (DL-EPR) and ditching tests, degree of sensitization (DOS) and intergranular corrosion (IGC) susceptibility was evaluated. It was found that the wrought samples showed slightly lower IGC susceptibility compared to their AM counterpart. DOS and IGC attacks increased with sensitization time for all samples. Dislocation cellular structures were found to have little to no impact on DOS and IGC for the AM samples. Sensitized at 100 h, the AM sample showed significant Cr depletion along high-angle grain boundaries (12.35 wt% on average) and exhibited Cr carbide precipitation. Mo-rich particles along grain boundaries were also observed. The DL-EPR test attacks the surface oxide film and grain boundaries while the ditching test attacks the melt pool boundaries and grain boundaries (IGC and pitting). Changes to the DL-EPR and ditching standards for AM application have been proposed in this work.

316L stainless steel↗

Influence of quenching agent on microstructure, properties and thermal stress of SiC{sub p}/2009 composites

15% vol. SiC{sub p}/2009 composites prepared by powder metallurgy were quenched in room temperature water and 20% polyethylene glycol (PEG) solution respectively, then aged naturally. The influence of quenching agent on microstructure, properties and thermal stress of SiC{sub p}/2009 composites were investigated by means of scanning/transmission electron microscope, hardness and tensile test. The results showed that the number of precipitated phase in water quenched composites increased, with much finer in size and more homogeneous in distribution compared with 20% PEG quenched one. Meanwhile, the density of dislocation in composites by water quenching was also much higher. Intergranular corrosion did not occur with the two quenching agents. The 20% PEG quenched composites exhibited slight lower hardness and higher electrical conductivity than that of water quenched one. The two quenched composites showed same level in tensile strength, but the yield strength of water-quenched composites was higher (8 MPa, 3%). The usage of 20% PEG reduced thermal stress and minimized warping deformation of the parts, it is a more suitable quenching agent for SiC{sub p}/2009 composites in engineering application fields. - Highlights: •SiC{sub p}/2009 composites quenched by water and 20% PEG solution were investigated. •Aging precipitation behavior of SiC{sub p}/2009 composites is sensitive to quenchant. •Influence of quenching agent on properties of SiC{sub p}/2009 composites are minimal. •Quenching with 20% PEG reduces thermal stress of SiC{sub p}/2009 composites remarkably. •20% PEG is a more suitable quenching agent for SiC{sub p}/2009 composites than water.

36 MATERIALS SCIENCE↗

Corrosion of alloys in a chloride molten salt (NaCl-LiCl) for solar thermal technologies

Next-generation solar power conversion systems in concentrating solar power (CSP) applications require high-temperature advanced fluids in the range of 600–800 °C. Current commercial CSP plants use molten nitrate salt mixtures as the heat transfer fluid and the thermal energy storage (TES) media while operating with multiple hours of energy capacity and at temperatures lower than 565 °C. At higher temperatures, the nitrates cannot be used because they decompose. Molten chloride salts are candidates for CSP applications because of their high decomposition temperatures and good thermal properties; but they can be corrosive to common alloys used in vessels, heat exchangers, and piping at these elevated temperatures. In this article, we present the results of the corrosion evaluations of several alloys in eutectic 34.42 wt% NaCl – 65.58 wt% LiCl at 650–700 °C in nitrogen atmosphere. Electrochemical evaluations were performed using open-circuit potential followed by a potentiodynamic polarization sweep. Corrosion rates were determined using Tafel slopes and Faraday's law. A temperature increase of as little as 50 °C more than doubled the corrosion rate of AISI stainless steel 310 and Incoloy 800H compared to the initial 650 °C test. These alloys exhibited localized corrosion. Inconel 625 was the most corrosion-resistant alloy with a corrosion rate of 2.80±0.38 mm/year. For TES applications, corrosion rates with magnitudes of a few millimeters per year are not acceptable because of economic considerations. Additionally, localized corrosion (intergranular or pitting) can be catastrophic. Furthermore, corrosion-mitigation approaches are required for advanced CSP plants to be commercially viable.

47 OTHER INSTRUMENTATION↗

Mechanistic transition of stainless steel 304L corrosion in MgCl 2 phase change material under thermal cycling

Magnesium chloride (MgCl 2 )-based molten salt phase change materials (PCMs) are promising candidates for thermal energy storage (TES) owing to their advantageous thermophysical properties, however, their high corrosivity in the molten state limits material compatibility. In this study, the corrosion behavior of 304?L stainless steel (SS304L) exposed to MgCl2 PCM was investigated as a function of thermal cycling (up to 9000 cycles) relevant to PCM-based TES systems. Microstructural changes and elemental redistribution at the alloy-salt interface under thermal cycling conditions were characterized using synchrotron-based X-ray fluorescence (XRF) and scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM-EDS). Results show that corrosion is governed by selective Cr-dissolution and elemental diffusion near the interface and grain boundaries. A clear transition in the dominant corrosion mechanism is observed with increasing thermal cycles. Surface corrosion is the dominant mechanism up to 1000 cycles, whereas intergranular corrosion becomes the primary degradation mode beyond 2000 cycles. These mechanistic changes are interpreted in terms of evolving interfacial chemistry, microstructure and the diffusion-driven redistribution of alloying elements.

36 MATERIALS SCIENCE↗

Characterization of Al-Mg Alloy Aged at Low Temperatures

For this research, long-term aged [343 K (70 °C) for 30 months and natural exposure for over 10 years] Al 5456 H116 samples were characterized using electron backscatter diffraction (EBSD), scanning transmission electron microscopy (STEM), state-of-the-art energy-dispersive X-ray spectroscopy (EDS) systems, and small-angle neutron scattering (SANS). ASTM G-67 mass loss tests of the sensitized Al 5456 alloy samples were conducted. Intragranular Mg-rich precipitates, such as Guinier–Preston (GP) zones, were confirmed in Al 5456 H116 aged at 343 K (70 °C) for 30 months, and the volume of these precipitates is 1.39 pct. β' phase is identified at the grain boundary of a navy ship sample, while high-resolution STEM results reveal no intragranular precipitates. Intergranular corrosion (IGC) of Al 5456 was found to be related to the continuity of intergranular precipitates.

36 MATERIALS SCIENCE↗

Synergistic Effects of Molten Salt Corrosion and Proton Irradiation on Grain Boundary Strength in Ni-20Cr

Nickel-based alloys are leading contenders for use as structural materials in molten salt reactors. While there have been extensive studies on the impact of fluoride/chloride-based molten salt corrosion on the microstructural evolution of various nickel-based alloys, the effects of simultaneous molten salt corrosion and radiation on the mechanical integrity of grain boundaries (GBs) remain underexplored. In this study, we use a Ni-20Cr model alloy to investigate this issue, subjecting it to simultaneous molten fluoride salt corrosion and proton irradiation. We performed cross-sectional and chemically-sensitive electron microscopy characterization of the microstructures of these materials, identifying the characteristic corrosion-induced microstructure and local chemical heterogeneity near GBs. After developing a sample preparation method for reliable characterization of GB strength, we assess the mechanical degradation of GBs using in situ push-to-pull micro tensile tests. Our findings reveal that voids induced by corrosion are the primary influence on the failure mode of GBs, regardless of whether proton irradiation is present. For materials that exhibit ductile fracture, those subjected to simultaneous corrosion and radiation exhibit lower yield strengths than those exposed to corrosion alone, which may be linked to the previously observed phenomenon of proton irradiation-decelerated intergranular corrosion in molten salt.

36 - MATERIALS SCIENCE↗

Advanced heat exchanger development for molten salts

This study addresses present work concerned with advanced heat exchanger development for molten salt in nuclear and non nuclear thermal systems. The molten salt systems discussed herein use alloys, such as Hastelloy N and 242, which show corrosion resistance to molten salt at nominal operating temperatures up to 700°C. These alloys were diffusion welded, and the corresponding information is presented. Test specimens were prepared for exposing diffusion welds to molten salt environments. Hastelloy N and 242 were found to be weldable by diffusion welding, with ultimate tensile strengths about 90% of base metal values. Both diffusion welds and sheet material in Hastelloy N were corrosion tested in?58 mol% KF and 42 mol% ZrF4 at 650, 700, and 850°C for 200, 500, and 1,000 hours. Corrosion rates found were similar between welded and nonwelded materials, typically <10 mils per year. For materials of construction, nickel and alloys with dense nickel coatings are effectively inert to corrosion in fluorides, but not so in chlorides. Hence, additional testing of selected alloys for resistance to intergranular corrosion is needed, as is a determination of corrosion rate as a function of contaminant type and alloy composition with respect to chromium and carbon to better define the optimal chromium and carbon composition, independent of galvanic or differential solubility effects. Also presented is the division of the nuclear reactor and high temperature components per ASME standards, along with design requirements for a subcritical Rankine power cycle heat exchanger that has to overcome pressure difference of about 17 MPa.

42 ENGINEERING↗

Filler Wire Development for 2195 Aluminum-Lithium

The objective of the research was to determine the susceptibility of submitted welded 2195 plate in an AI (Alternate Immersion) environment. Forty-day AI exposure was completed on 8 welded 2195 stress corrosion samples. No stress corrosion cracking (SCC) was found on any of the samples tested. All 8 samples experienced exfoliation corrosion attack in the heat-affected zone (HAZ) adjacent to the weld. All samples were examined metallographically and showed varying degrees of intergranular corrosion (IG). The filler metal on all samples showed moderate to heavy pitting.

Bjorkman, Gerald W.↗