Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Investigating the performance of an ion luminescence probe as a multichannel fast-ion energy spectrometer using pulse height analysis

We investigate the capability of a fast-ion luminescent probe to operate as a pulse height ion energy analyzer. An existing high sensitivity system has been reconfigured as a single channel ion detector with an amplifier to give a bandwidth comparable to the phosphor response time. A digital pulse processing method has been developed to determine pulse heights from the detector signal so as to obtain time-resolved information on the ion energy distribution of the plasma ions lost to the wall of the TJ-II stellarator. Finally, the potential of this approach for magnetic confined fusion plasmas is evaluated by studying representative TJ-II discharges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A heavy ion beam probe system for investigation of a modified Penning discharge

An ion beam probe diagnostic system can measure time- and space-resolved profiles of plasma space potential and electron density. In combination with a computer iterative technique, the ion beam probe can determine both the space potential profile in plasmas containing strong electric fields and potentials comparable in magnitude to the energy of the probing ion beam. During ion beam probing of a modified Penning discharge, several groups of secondary ions were observed coming from the plasma with a fixed primary beam energy and momentum. The energies of these ions were within 10 percent of the values predicted by a computer-generated model of the potential profile in the plasma. The mechanical and electronic components of the system are described, with particular emphasis on those features required to probe plasma potentials comparable in magnitude to the ion beam energy.

Kambic, G. X.↗

Development of the scintillator-based probe for fast-ion losses in the HL-2A tokamak

A new scintillator-based lost fast-ion probe (SLIP) has been developed and operated in the HL-2A tokamak [L. W. Yan, X. R. Duan, X. T. Ding, J. Q. Dong, Q. W. Yang, Yi Liu, X. L. Zou, D. Q. Liu, W. M. Xuan, L. Y. Chen, J. Rao, X. M. Song, Y. Huang, W. C. Mao, Q. M. Wang, Q. Li, Z. Cao, B. Li, J. Y. Cao, G. J. Lei, J. H. Zhang, X. D. Li, W. Chen, J. Chen, C. H. Cui, Z. Y. Cui, Z. C. Deng, Y. B. Dong, B. B. Feng, Q. D. Gao, X. Y. Han, W. Y. Hong, M. Huang, X. Q. Ji, Z. H. Kang, D. F. Kong, T. Lan, G. S. Li, H. J. Li, Qing Li, W. Li, Y. G. Li, A. D. Liu, Z. T. Liu, C. W. Luo, X. H. Mao, Y. D. Pan, J. F. Peng, Z. B. Shi, S. D. Song, X. Y. Song, H. J. Sun, A. K. Wang, M. X. Wang, Y. Q. Wang, W. W. Xiao, Y. F. Xie, L. H. Yao, D. L. Yu, B. S. Yuan, K. J. Zhao, G. W. Zhong, J. Zhou, J. C. Yan, C. X. Yu, C. H. Pan, Y. Liu, and the HL-2A Team , Nucl. Fusion 51, 094016 (2011)] to measure the losses of neutral beam ions. The design of the probe is based on the concept of the α-particle detectors on Tokamak Fusion Test Reactor (TFTR) using scintillator plates. The probe is capable of traveling across an equatorial plane port and sweeping the aperture angle rotationally with respect to the axis of the probe shaft by two step motors, in order to optimize the radial position and the collimator angle. The energy and the pitch angle of the lost fast ions can be simultaneously measured if the two-dimensional image of scintillation light intensity due to the impact of the lost fast ions is detected. Measurements of the fast-ion losses using the probe have been performed during HL-2A neutral beam injection discharges. The clear experimental evidence of enhanced losses of beam ions during disruptions has been obtained by means of the SLIP system. A detailed description of the probe system and the first experimental results are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of ion and electron temperatures in plasma blobs by using an improved ion sensitive probe system and statistical analysis methods

We have measured ion temperature as well as electron temperature in plasma blobs observed in a linear plasma device by using an improved ion sensitive probe. Current-voltage characteristics of the ion sensitive probe inside and outside plasma blobs were re-constructed with a conditional sampling method. It is clearly found that both ion and electron temperatures in plasma blobs decrease more slowly in a cross-field direction than those in a bulk plasma without plasma blobs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2D electron density profile measurement in tokamak by laser-accelerated ion-beam probe

A new concept of Heavy Ion Beam Probe (HIBP) diagnostic has been proposed, of which the key is to replace the electrostatic accelerator of traditional HIBP by a laser-driven ion accelerator. Due to the large energy spread of ions, the laser-accelerated HIBP can measure the two-dimensional (2D) electron density profile of tokamak plasma. In a preliminary simulation, a 2D density profile was reconstructed with a spatial resolution of about 2 cm, and with the error below 15% in the core region. Diagnostics of 2D density fluctuation is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interpretation and implementation of an ion sensitive probe as a plasma potential diagnostic

An ion sensitive probe (ISP) is developed as a robust diagnostic for measuring plasma potentials ({Phi}{sub P}) in magnetized plasmas. The ISP relies on the large difference between the ion and electron gyroradii ({rho}{sub i}/{rho}{sub e}{approx}60) to reduce the electron collection at a collector recessed behind a separately biased wall distance {approx}{rho}{sub i}. We develop a new ISP method to measure the plasma potential that is independent of the precise position and shape of the collector. {Phi}{sub P} is found as the wall potential when charged current to the probe collector vanishes during the voltage sweep. The plasma potentials obtained from the ISP match {Phi}{sub P} measured with an emissive probe over a wide range of plasma conditions in a small magnetized plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scanning ion sensitive probe for plasma profile measurements in the boundary of the Alcator C-Mod tokamak

A new Ion Sensitive Probe head has been created for the outer-midplane scanning probe system on the Alcator C-Mod tokamak. The new probe head contains three elements: an ion sensitive probe to measure ion temperature and plasma potential, a Langmuir probe to measure electron temperature, density, and floating potential, and a second Langmuir probe to measure ion saturation current and the density fluctuations arising from ''blob'' events. The ion sensitive probe current is normalized to this measurement to reduced deleterious effects of the strong fluctuations. Design of the high heat flux probe (>100 MW/m{sup 2}) and initial results are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pure ion current collection in ion sensitive probe measurement with a metal mesh guard electrode for evaluation of ion temperature in magnetized plasma

This paper presents a new design of ion sensitive probe (ISP) that enables collection of pure ion current for accurate measurement of the perpendicular ion temperature in magnetized plasmas. The new type of ISP resolves a longstanding issue widely observed in ISP type measurements, namely, that the current-voltage characteristic is smeared by an unexpected electron current in the standard ISP model. The new ISP is equipped with a fine scale metal mesh on the sensor entrance to prevent electrons from flowing to the sensor, a phenomenon considered to be caused by the space-charge effect. The new ISP successfully measured the ion temperature of electron cyclotron resonance plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Potential measurements with heavy ion beam probe system on LHD

The heavy ion beam probe system in the Large Helical Device (LHD) was improved as follows. At first, the additional new sweeper was installed into the diagnostic port to extend the observable region. By using this sweeper, the potential profile was measured in a wider minor radius range than in previous experiments, in the case of outward shifted magnetic configuration of LHD. Next, the real time control system was installed to control the probe beam orbit for measuring the potential in plasma with large plasma current. In this system, a digital signal processor was used to control the probe beam in real time. The system worked well in the fixed position observation mode. In the sweeping mode for profile measurement, this control system became unstable. The details of this system and the experimental results are reported in this article.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heavy ion beam probe coordinate mapping and calibration at WEGA stellarator

The heavy ion beam probe (HIBP) is an established nonperturbing diagnostic for high spatially and temporary resolved measurements of magnetically confined plasma parameters such as potential, density, and temperature. These quantities can be determined from the change in the ion beam parameters (charge, intensity, and trajectory) passing through a plasma volume due to collisions with electrons and interaction with the confining magnetic field. One of the problems that should be solved during HIBP installation and tuning is the coordinate matching. Conventionally the coordinate mapping of the HIBP measurement point is provided by ray tracing calculations of the ion beam in the magnetic field. However, it is very difficult to include all physical effects and uncertainties in the model. Thus, the result of the calculations may differ from the real probing position. In order to improve the mapping precision of the HIBP installed at the WEGA stellarator an additional measurement of the beam position is provided using a primary beam detector array inside the vacuum vessel. This allows comparing the measured and calculated ion beam positions in order to prove the calculated coordinate precision and include adjustments in the calculation code if necessary. The principle and the results of this calibration, which is not specific to WEGA but could be adapted to other experiments as well, are presented in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing the Failure Mechanism of SnO{sub 2} Nanowires for Sodium-Ion Batteries

Nonlithium metals such as sodium have attracted wide attention as a potential charge carrying ion for rechargeable batteries. Using in situ transmission electron microscopy in combination with density functional theory calculations, we probed the structural and chemical evolution of SnO{sub 2} nanowire anodes in Na-ion batteries and compared them quantitatively with results from Li-ion batteries (Huang, J. Y.; et al. Science 2010, 330, 1515-1520). Upon Na insertion into SnO{sub 2}, a displacement reaction occurs, leading to the formation of amorphous Na{sub x}Sn nanoparticles dispersed in Na{sub 2}O matrix. With further Na insertion, the Na{sub x}Sn crystallized into Na{sub 15}Sn{sub 4} (x = 3.75). Upon extraction of Na (desodiation), the Na{sub x}Sn transforms to Sn nanoparticles. Associated with the dealloying, pores are found to form, leading to a structure of Sn particles confined in a hollow matrix of Na{sub 2}O. These pores greatly increase electrical impedance, therefore accounting for the poor cyclability of SnO{sub 2}. DFT calculations indicate that Na{sup +} diffuses 30 times slower than Li{sup +} in SnO{sub 2}, in agreement with in situ TEM measurement. Insertion of Na can chemomechanically soften the reaction product to a greater extent than in lithiation. Therefore, in contrast to the lithiation of SnO{sub 2} significantly less dislocation plasticity was seen ahead of the sodiation front. This direct comparison of the results from Na and Li highlights the critical role of ionic size and electronic structure of different ionic species on the charge/discharge rate and failure mechanisms in these batteries.

25 ENERGY STORAGE↗

Probing the failure mechanism of nanoscale LiFePO{sub 4} for Li-ion batteries

LiFePO{sub 4} is a high power rate cathode material for lithium ion battery and shows remarkable capacity retention, featuring a 91% capacity retention after 3300 cycles. In this work, we use high-resolution transmission electron microscopy and electron energy loss spectroscopy to study the gradual capacity fading mechanism of LiFePO{sub 4} materials. We found that upon prolonged electrochemical cycling of the battery, the LiFePO{sub 4} cathode shows surface amorphization and loss of oxygen species, which directly contribute to the gradual capacity fading of the battery. The finding can guide the design and improvement of LiFePO{sub 4} cathode for high-energy and high-power rechargeable battery for electric transportation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heavy ion beam probe operation in time varying equilibria of improved confinement reversed field pinch discharges

Operation of a heavy ion beam probe (HIBP) on a reversed field pinch is unique from other toroidal applications because the magnetic field is more temporal and largely produced by plasma current. Improved confinement, produced through the transient application of a poloidal electric field which leads to a reduction of dynamo activity, exhibits gradual changes in equilibrium plasma quantities. A consequence of this is sweeping of the HIBP trajectories by the dynamic magnetic field, resulting in motion of the sample volume. In addition, the plasma potential evolves with the magnetic equilibrium. Measurement of the potential as a function of time is thus a combination of temporal changes of the equilibrium and motion of the sample volume. A frequent additional complication is a nonideal balance of ion current on the detectors resulting from changes in the beam trajectory (magnetic field) and energy (plasma potential). This necessitates use of data selection criteria. Nevertheless, the HIBP on the Madison Symmetric Torus has acquired measurements as a function of time throughout improved confinement. A technique developed to infer the potential in the improved confinement reversed field pinch from HIBP data in light of the time varying plasma equilibrium will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heavy ion beam probe measurements of radial potential profiles in the Modified Penning discharge

The reported measurements were conducted with the primary beam of an ion beam probe in a plasma discharge in which the space potential represents a large fraction of the primary beam energy. A Lewis ion beam probe similar to the device employed by Jobes et al. (1969) was used in the investigation. The apparatus used in the experiments is discussed along with the experimental procedure. The approximate radial potential profile was obtained by observing the effect of the plasma on the trajectory of the primary beam.

Kambic, G. X.↗

Heavy ion beam probe measurements of radial potential profiles in the modified Penning discharge

A heavy ion beam probe was used to examine the radial potential profile of a plasma in the modified Penning discharge. The plasma has strong (approximately kV) electrostatic potentials near the anode ring which can be a large fraction of the injected ion beam energy. A primary (singly ionized) thallium ion beam is injected through the plasma in the midplane of a double Penning anode ring. After passage through the plasma, primary and secondary (doubly ionized) ions are detected with either a set of flat probes or an electrostatic energy analyzer. A calculation of the primary orbit through the plasma is performed to obtain an approximation to the measured primary beam trajectory. As the real radial potential profile is unknown, an adjustable model is used in the computer program. The adjustable potential profile is varied until the best agreement between measured and calculated trajectories is obtained. Secondary orbits are also predicted using the best fitting adjustable profile. The calculations indicate that secondary beams originating at more than one point in the plasma can be simultaneously observed at the electrostatic analyzer with certain primary beam initial conditions.

Kambic, G. X.↗

2D potential measurements by applying automatic beam adjustment system to heavy ion beam probe diagnostic on the Large Helical Device

Two-dimensional potential profiles in the Large Helical Device (LHD) were measured with heavy ion beam probe (HIBP). To measure the two-dimensional profile, the probe beam energy has to be changed. However, this task is not easy, because the beam transport line of LHD-HIBP system is very long (∼20 m), and the required beam adjustment consumes much time. To reduce the probe beam energy adjustment time, an automatic beam adjustment system has been developed. Using this system, required time to change the probe beam energy is dramatically reduced, such that two-dimensional potential profiles were able to be successfully measured with HIBP by changing the probe beam energy shot to shot.

43 PARTICLE ACCELERATORS↗