Measurements of the 239 Pu(n,f)/ 235 U(n,f) and 238 U(n,f)/ 235 U(n,f) Cross-Section Ratios Using Quasi-Monoenergetic Neutron Beams

Neutron-induced fission cross-section ratio measurements were carried out at Triangle Universities Nuclear Laboratory (TUNL) over multiple experiment campaigns from 2021-2023. The total beam time for these measurements across all the experimental campaigns was approximately three weeks. This work was intended to serve as an independent validation of the fissionTPC cross-section ratio measurements. In contrast to the white spectrum neutron source and time-projection chamber utilized in the fissionTPC, these measurements utilized pulsed, quasi-monoenergetic neutron beams and fission ionization chambers. Therefore, this work has different sources of systematic error and can be used as a complementary measurement. In this report we describe our fission cross-section ratio measurements, analysis, results and provide a detailed uncertainty budget.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Relativistic rise measurement for heavy cosmic rays in xenon

Potential advantages of the use of the relativistic rise of energy loss in gas-filled counters for cosmic ray energy measurement have been noted by Tueller et al. (1979) and Gregory and Parnell (1979). Gregory and Parnell have reported measurements on the relativistic rise for cosmic ray iron nuclei in parallel plate ionization chambers 8.4 cm thick filled with a xenon and methane mixture. The present investigation is concerned with the observed rise and ionization signal fluctuations for a sample of elements from carbon through iron in the cosmic rays. The results are compared with a calculation of the energy deposit within the ion chamber.

Gregory, J. C.

A study of the scintillation light induced in liquid xenon by electrons and alpha particles

The time dependence and the intensity of the primary scintillation light in liquid Xe excited by Am-241 alpha particles and Bi-207 internal-conversion electrons were measured at different electric-field strengths. High-purity liquid Xe was used to fill a parallel-plate ionization chamber equipped with a CaF2 window coupled to a UV-sensitive photomultiplier tube. The effect of the specific ionization density on the scintillation light and the time correlation between the light signal and the charge signal is reported. It is demonstrated that the fast scintillation signal produced in liquid Xe by an ionizing particle provides an ideal trigger in a detector aiming at a complete three-dimensional event reconstruction with an excellent background rejection capability.

Aprile, Elena

Relative abundances of elements (20 or = Z or = 28) at energies up to 70 GeV/amu using relativistic rise in ion chambers

The results of a new balloon borne cosmic ray detector flown from Palestine, TX in Sept., 1982 are discussed. The exposure of 62 square meter-ster-hr is sufficient to prove the concept of using gas ionization chambers as energy measuring devices in the relativistic rise region. The abundances, relative Fe-26, of the pure secondaries Cr-22 and Ti-24, the pure primary Ni26, and the mixed primary and secondary Ca-20 between 6 and 70GeV/amu were measured.

Barthelmy, S. D.

Proton and Electron Threshold Energy Measurements for Extravehicular Activity Space Suits

Construction of ISS will require more than 1000 hours of EVA. Outside of ISS during EVA, astronauts and cosmonauts are likely to be exposed to a large fluence of electrons and protons. Development of radiation protection guidelines requires the determination of the minimum energy of electrons and protons that penetrate the suits at various locations. Measurements of the water-equivalent thickness of both US. and Russian EVA suits were obtained by performing CT scans. Specific regions of interest of the suits were further evaluated using a differential range shift technique. This technique involved measuring thickness ionization curves for 6-MeV electron and 155-MeV proton beams with ionization chambers using a constant source-to-detector distance. The thicknesses were obtained by stacking polystyrene slabs immediately upstream of the detector. The thicknesses of the 50% ionizations relative to the maximum ionizations were determined. The detectors were then placed within the suit and the stack thickness adjusted until the 50% ionization was reestablished. The difference in thickness between the 50% thicknesses was then used with standard range-energy tables to determine the threshold energy for penetration. This report provides a detailed description of the experimental arrangement and results.

Moyers, M. F.

On the interpretation of observed data from C-dE/dx detectors

The paper describes a Cerenkov detector system designed to obtain abundances and energy spectra of cosmic ray nuclei above charge 12 and above 350 MeV/nucleon. The detector system consists of three pulse ionization chambers, a Lucite Cerenkov counter and a plastic scintillation-counter hodoscope. The data analysis follows from the standard dE/dx-C technique. It is shown that by using the relativistic ionization rise, the resolution and pulse height corresponding to charged particles of Beta ? 1 in Cerenkov detectors can be determined. Least-squares-fit procedures are used to obtain area and time variations of detector response from flight data and to extract elemental abundances from data with charge resolution of roughly 0.3 charge units.

Benegas, J. C.

The heavy nuclei experiment on HEAO-3

The HEAO-3 experiment to study the heavy and ultraheavy nuclei in cosmic radiation is described. The array is double-ended and consists of three main elements. Two pressure chambers, filled with an argon-methane mixture at about 850 torr, each contain two x-y hodoscopes made of wires spaced 1 cm apart and three parallel plate ionization chambers. Between the pressure chambers is mounted a Cerenkov counter composed of two layers of Pilot 425 radiator looked at by eight photomultipliers. The instrument is designed to achieve a charge resolution of 0.3 charge units over the charge range 17-120, which requires a measurement accurate to 0.6 percent at Z = 100. Examination of selected data shows that the instrument has the intrinsic resolution needed.

Binns, W. R.

Ultraheavy cosmic rays - HEAO-3 results

The instrumentation and results from the Heavy Nuclei experiment on the HEAO 3 satellite are described. Six independently analyzed dual-gap ionization chambers measured the energy loss of the cosmic rays while a Cerenkov counter with 8 independently analyzed photomultipliers viewed two sheets of Pilot 425 plastic in a white box. Trajectories of the cosmic ray nuclei were determined in multiwire ionization hodoscopes. Variations in abundances were observed to be imperfectly ordered in terms of the first ionization potential, and volatility was also ruled out as the controlling factor. A predicted drop in abundance after Ba-56 was found, along with another sharp fall above Pb-82. Only one actinide-type event was detected during the 14 mos of viewing, a result consistent with other findings but which testifies against r-process formation.

Israel, M. H.

Liquid xenon time projection chamber for gamma rays in the MeV region: Development status

The feasibility of a large volume Liquid Xenon Time Projection Chamber (LXe-TPC) for three dimensional imaging and spectroscopy of cosmic gamma ray sources, was tested with a 3.5 liter prototype. The observation of induction signals produced by MeV gamma rays in liquid xenon is reported, with a good signal-to-noise ratio. The results represent the first experimental demonstration with a liquid xenon ionization chamber of a nondestructive readout of the electron image produced by point-like charges, using a sense wire configuration of the type originally proposed in 1970 by Gatti et al. An energy resolution as good as that previously measured by the millimeter size chambers, was achieved with the large prototype of 4.4 cm drift gap.

Aprile, E.

Energy spectra of elements with 18 less than or equal to Z less than or equal to 28 between 10 and 300 GeV/amu

The HEAO-3 Heavy Nuclei Experiment is composed of ionization chambers above and below a plastic Cherenkov counter. The energy dependence of the abundances of elements with atomic number, Z, between 18 and 28 were measured at very high energies where they are rare and thus need the large area x time of this experiment. The measurements of the Danish-French HEAO-3 experiment were extended to higher energies, using the relativistic rise of ionization signal as a measure of energy, and determine source abundances for Ar and Ca.

Jones, M. D.

Energy spectra of elements with 18 or = Z or = 28 between 10 and 300 GeV/amu

The HEAO-3 Heavy Nuclei Experiment is composed of ionization chambers above and below a plastic Cerenkov counter. The energy dependence of the abundances of elements with atomic number, Z, between 18 and 28 at very high energies where they are rare and thus need the large area x time are measured. The measurements of the Danish-French HEAO-3 experiment (Englemann,, et al., 1983) are extended to higher energies, using the relativistic rise of ionization signal as a measure of energy. Source abundances for Ar and Ca were determined.

Jones, M. D.

Photoabsorption cross section of acetylene in the EUV region

The measurement of the absolute photoabsorption cross sections of C2H2 in the 175-740 A region by means of a double ionization chamber is reported. The continuum background source is the synchrotron radiation emitted by the Wisconsin 240 MeV electron storage ring. It is found that the cross sections range from 2 to a maximum of 36 Mb. Two new Rydberg series are identified and the cross section data are applied in the analysis of various sum rules. From the rules, it is shown that the data of C2H2 in the 580-1088 A range may be too low, while the measured ionization transition moment may be too high.

Wu, C. Y. R.

Decomposition of Electron Ionization Mass Spectra for Space Application Using a Monte-Carlo approach

Rationale: Quadrupole mass spectrometers equipped with an electron ionization (EI) sources have been widely used in space exploration to investigate the composition of planetary surfaces and atmospheres. However, the complexity of the samples and the minimal calibration for the fragmentation of molecules in the ionization chambers have prevented the deconvolution of the majority of the mass spectra obtained at different targets, thus limiting the determination of the exact composition of the samples analyzed. We propose a Monte‐Carlo approach to solve this issue mathematically. Methods: We decomposed simulated mass spectra of mixtures acquired with unit resolving power mass spectrometers and EI sources into the sum of the single components fragmentation patterns weighted by their relative concentration using interior‐point least‐square fitting. To fit compounds with poorly known fragmentation patterns, we used a Monte‐Carlo method to vary the intensity of individual fragment ions. We then decomposed the spectrum thousands of times to obtain a statistical distribution. Results: By performing the deconvolution on a mixture of seven different molecules with interfering fragmentation patterns (H2O, O2, CH4, Ar, N2, C2H4, and C2H6) we show that this approach retrieves the mixing ratio of the individual components more accurately than regular mass spectra decomposition methods that rely on fragmentation patterns from general databases. It also provides the probability density function for each species's mixing ratio. Conclusions: By removing the solution degeneracy in the decomposition of mass spectra, the method described herein could significantly increase the scientific retrieval from archived space flight mass spectrometry data, where calibration of the ionization source is no longer an option.

Thomas Gautier

Energy dependence of chain fission product yields from neutron-induced fission of 235 U, 238 U, and 239 Pu

The lack of completeness and systematic studies of cumulative fission product yield (FPY) from the three major actinides of 235 U, 238 U, and 239 Pu, over a broad energy range, was the primary motivation for the LLNL-LANL-TUNL collaboration. Given the focus on resolving FPY behavior around fission spectrum neutron energies, our 2016 data provides FPY measurements in fine energy steps in the range of 0.5–5.5 MeV and an additional anchor point at 14.8 MeV. Recently, our collaboration filled the gap between second chance fission and 14.8 MeV, providing a comprehensive study at eleven incident neutron energies from 0.5 to 14.8 MeV. However, during the course of the last measurements, it was found that the reported masses of the actinide deposits in the fission ionization chambers, which were used to measure the number of fissions, were not consistent with the complementary tests. Therefore, some corrections to the old data are needed. The purpose of this paper is to summarize all of the high-yield FPY data obtained for 235 U, 238 U, and 239 Pu isotopes using quasi-monoenergetic neutron beams at 11 incident energies ranging from E n = 0.5 to 14.8 MeV.

Tonchev, A. P. [Lawrence Livermore National Labora

Classification of events from α -induced reactions in the MUSIC detector via statistical and ML methods

The Multi-Sampling Ionization Chamber (MUSIC) detector is typically used to measure nuclear reaction cross sections relevant for nuclear astrophysics, fusion studies, and other applications. From the MUSIC data produced in one experiment scientists carefully extract an order of 10 3 events of interest from about 10 9 total events, where each event can be represented by an 18-dimensional vector. However, the standard data classification process is based on expert driven, manually intensive data analysis techniques that require several months to identify patterns and classify the relevant events from the collected data. Here, to address this issue, we present a method for the classification of events originating from specific α-induced reactions by combining statistical and machine learning methods that require significantly less input from the domain scientist, relative to the standard technique. Here, we applied the new method to two experimental data sets and compared our results with those obtained using traditional methods. With few exceptions, the number of events classified by our method agrees within ±20% with the results obtained using traditional methods. With the present method, which is the first of its kind for the MUSIC data, we have established the foundation for the automated extraction of physical events of interest from experiments using the MUSIC detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Constraining the impact of chlorine as a neutron absorber in next-gen fast reactor designs

The role of chlorine as a neutron poison and as a seed for producing radioactive waste in nuclear systems has driven a renewed interest to improve its nuclear data uncertainties. Additionally, basic and applied science programs that use CLYC (Cs 2 LiYCl 6 :Ce) detectors for neutron spectroscopy and monitoring are also very sensitive to any change in chlorine nuclear data for simulations of the detector response. In this work, sensitivities relevant for these different applications are addressed through simulations of the efficiency of CLYC detectors in a fast fission spectrum when applying new chlorine nuclear data as input. These simulations are validated by an experimental measurement using CLYC detectors coupled to an ionization chamber loaded with a 252 Cf spontaneous fission source. The results are then used to obtain the first reliable direct measurement of the 35 Cl(n,p 0 ) and summed Cl(n,p+n,α) fission spectrum average cross sections, found to be 54.7(32) and 105.0(98) mb, respectively. The results are within uncertainty of calculated fission spectrum averaged cross sections based on recently re-evaluated chlorine nuclear data, which confirm recent impact studies performed for the Molten Chloride Reactor Experiment. Meanwhile, there currently exists only one published criticality benchmark experiment that is sufficiently sensitive to chlorine nuclear data. Discrepancies are found with this set of criticality safety benchmarks, which are more sensitive to thermal and epithermal neutron energies than the energies, above 100 keV, tested in this current work. Hence, there is still a need to re-evaluate the chlorine nuclear data at lower energies to assess these discrepancies. Interpretation of the data from future “faster” criticality benchmarks, which are needed for next-gen fast reactor designs, benefit from the improved constraints on the chlorine nuclear data validated in this work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS