Search NASASearch

SEARCH · Search NASA

Results for “ISS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

46 records · Page 3

Erosion Results of the MISSE 9-15 Polymers and Composites Experiment 1-4 (PCE 1-4)

Polymers and other oxidizable materials on the exterior of spacecraft in the low Earth orbit (LEO) space environment can be eroded from reaction with atomic oxygen (AO). Therefore, in order to design durable spacecraft it is important to know the extent of erosion that will occur during a mission. This can be determined by knowing the LEO AO erosion yield, E y (volume loss per incident oxygen atom), of materials susceptible to AO reaction. In addition, recent flight experiments have shown that the AO E y can vary with the AO fluence and/or solar exposure. Therefore, obtaining AO E y data for materials flown on various spaceflight missions is important. NASA Glenn Research Center has flown numerous experiments as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS) to characterize the LEO E y of polymers, composites, protective coatings, and other spacecraft materials. Recently, four Glenn experiments with 365 flight (F) samples were flown on ISS’s MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 flown as part of the MISSE-12 and MISSE-15 missions, and the PCE-4 flown as part of the MISSE-13 mission. Although each experiment had numerous sample objectives, the primary objective was to determine the LEO AO E y of various spacecraft materials as a function of solar irradiation and AO fluence. This paper provides a summary of the erosion data for the PCE 1-4 AO E y samples. The AO E y for 150 samples flown in either the LEO ram, wake, zenith or nadir directions are provided. The AO ram fluence varied from 2.97×10 20 atoms/cm 2 after 0.89 years of direct space exposure (with relatively high levels of Si contamination) on MISSE 12 to 3.93×10 20 atoms/cm 2 after 1.17 years of direct space exposure on MISSE-10. The ram AO E y values for uncoated polymers range from 3.81×10 –25 cm 3 /atom for polytetrafluoroethylene (M9R-C20 F) exposed to an AO fluence of 3.44×10 20 atoms/cm 2 on MISSE-9 to 4.43×10 –23 cm 3 /atom for AO etched low density polyimide aerogel (M12R-C21 F) exposed to an AO fluence of 2.97×10 21 atoms/cm 2 on MISSE-12. Because of the low AO fluence and relatively high Si contamination, a number of PCE-3 wake samples experienced mass gain. Thus, AO E y values are not provided for these samples. Although there are calculated AO E y values for the zenith, wake and nadir samples, the ram AO E y for a particular material is a more reliable value in terms of AO exposure because the zenith, wake and nadir directions were exposed to either no or very little AO fluence and thus other space environmental factors (i.e. vacuum, thermal extremes and thermal cycling, and/or various types of radiation) are responsible for the mass loss.

Erosion yield

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

drinking water

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

iodine

Mass Economy Evaluation for Integrated ECLSS and Propulsion Architecture

As missions in Low Earth Orbit (LEO) lengthen and extend to deep space, minimizing resupply needs becomes vital for sustaining crewed operations. Traditional life support systems depend on consumables resupplied from Earth, a method that is increasingly impractical for missions beyond LEO, such as lunar outposts or Mars transit. Long-duration missions require more efficient, autonomous systems that can recycle essential resources, particularly water and oxygen, to minimize the frequency and mass of resupply missions. The Environmental Control and Life Support System (ECLSS) is essential to such missions, with the International Space Station (ISS) serving as a testbed for advanced water recovery and partial oxygen recycling via physico-chemical methods. Yet, ECLSS and propulsion subsystems generally operate independently, despite overlapping requirements and potential areas for synergy. For instance, ECLSS byproducts, water, CO₂, and hydrogen, could be repurposed for propulsion, potentially reducing dedicated propellant mass and increasing overall system efficiency. One promising approach is to develop shared-resource architectures that integrate ECLSS with propulsion systems. This study examines the potential of such integration through the Sabatier CO₂ reduction process, focusing on water management as a key factor in system mass trade-offs. The Sabatier reaction produces water and methane from metabolic CO₂ and electrolytic hydrogen, partially closing the life support loop and providing methane, which could serve as a propellant. This integration could minimize waste, reduce resupply requirements, and enhance mission mass efficiency. A dynamic modeling framework will be used to simulate resource flows over long missions, capturing interactions between life support and propulsion. By comparing integrated versus separate system configurations, the study aims to quantify mass benefits and penalties, informing future habitat designs and trade studies for missions prioritizing autonomy and mass efficiency.

ECLSS

Mass Economy Evaluation for Integrated ECLSS and Propulsion Architecture

As missions in low Earth orbit (LEO) lengthen and extend to deep space, minimizing resupply needs becomes vital for sustaining crewed operations. Traditional life support systems depend on consumables resupplied from Earth, a method that is increasingly impractical for missions beyond LEO, such as lunar outposts or Mars transit. Long-duration missions require more efficient, autonomous systems that can recycle essential resources, particularly water and oxygen, to minimize the frequency and mass of resupply missions. The Environmental Control and Life Support System (ECLSS) is essential to such missions, with the International Space Station (ISS) serving as a testbed for advanced water recovery and partial oxygen recycling via physico-chemical methods. Yet, ECLSS and propulsion subsystems generally operate independently, despite overlapping requirements and potential areas for synergy. For instance, ECLSS byproducts, water, CO 2 , and hydrogen, could be repurposed for propulsion, potentially reducing dedicated propellant mass and increasing overall system efficiency. One promising approach is to develop shared-resource architectures that integrate ECLSS with propulsion systems. This study examines the potential of such integration through the Sabatier CO₂ reduction process, focusing on water management as a key factor in system mass trade-offs. The Sabatier reaction produces water and methane from metabolic CO 2 and electrolytic hydrogen, partially closing the life support loop and providing methane, which could serve as a propellant. This integration could minimize waste, reduce resupply requirements, and enhance mission mass efficiency. A dynamic modeling framework will be used to simulate resource flows over long missions, capturing interactions between life support and propulsion. By comparing integrated versus separate system configurations, the study aims to quantify mass benefits and penalties, informing future habitat designs and trade studies for missions prioritizing autonomy and mass efficiency.

ECLSS

Evaluation of Low-Energy Hydrogen Separation Method Using Metal-Organic Frameworks (MOFs) for Closed-Loop ECLSS Air Revitalization (CLEAR)

The State-of-the-Art (SOA) air revitalization architecture onboard the International Space Station (ISS) recovered approximately 50% of the oxygen (O 2 ) from metabolic carbon dioxide (CO 2 ) via the Sabatier process from 2011 to 2017. O 2 recovery is currently constrained by the limited availability of reactant hydrogen (H 2 ) preventing complete conversion of CO 2 to H 2 O. Increasing O 2 recovery within Closed-Loop ECLSS is essential to reducing resupply mass for long-duration manned missions; specifically focusing on water (H 2 O) which supplies H 2 for Sabatier via water electrolysis. Past ground test endeavors at Marshall Space Flight Center (MSFC) have attempted to recover H 2 from Sabatier-produced CH 4 using technologies such as carbon vapor deposition (CVD) and plasma pyrolysis. The byproducts of these technologies can act as a catalyst poison or reactor deadload to the Sabatier reactor. Hydrogen separation techniques must be utilized to maintain the Sabatier catalyst during gas recycling and must be scalable, non-energy intensive, and safe to operate in a habitation setting. Research indicated that metal-organic frameworks (MOFs) could meet these criteria and were tested for their capability to capture the various carbon-based gaseous products of CVD and plasma pyrolysis such as acetylene (C 2 H 2 ), ethylene (C 2 H 4 ), ethane (C 2 H 6 ), and carbon monoxide (CO) which would purify the hydrogen gas stream passing through the MOF. A sub-scale adsorption column was developed by Marshall Space Flight Center to test three MOF candidates against a synthetic gas mixture comprised of process-relevant carbonous gases and hydrogen to evaluate the separation capability of the MOFs. The results of the hydrogen separation capability, isothermal desorption capability, and demonstrated cyclic reuse of the MOF are presented in this paper.

Kagen Crawford

Improvement of Odor Control for the UWMS Hard-Sided Fecal Canister and the Alternate Fecal Canister

On longer range exploration missions, the mass and volume of critical hardware and consumables required to support crew will pose a big stowage challenge. This includes the hardware for the collection and storage of human metabolic solid waste. The amount of stowage needed for this hardware both before (empty) and after (full) use will be a significant burden on the overall spacecraft habitable volume, layout, and design. To help with this challenge, the National Aeronautics and Space Administration (NASA) Mars Campaign Office (MCO) Logistics Reduction (LR) Portfolio has developed a collapsible canister for the collection and containment of fecal deposits. The Alternate Fecal Canister (AFC) is a collapsible alternative to the exploration toilet Hard-sided Fecal Canister (HFC). The AFC in its empty state has a volumetric benefit to smaller vehicles on longer missions. The current designs for HFC and AFC were tested with human fecal material for odor containment at White Sands Test Facility (WSTF) where the tests on both were unsuccessful. The source of the lack of containment was isolated to a gasket used on both HFC and AFC. The gasket used was found to be open cell in design. This paper provides a summary of the materials selection and testing process to identify a replacement gasket material with the intention to replace the gaskets on both existing units as well as incorporate it into the designs going forward for future builds for exploration. Details will be provided on the design of the canisters interface with the odor bacteria lid which led to the selection of the thickness of the desired replacement. Finally, the paper will provide an update on the testing in advance of a return to WSTF for final testing and detail plans to complete testing and perform a demonstration on ISS with UWMS.

Toilet

Improvement of Odor Control for the UWMS Hard-Sided Fecal Canister and the Alternate Fecal Canister

On longer range exploration missions, the mass and volume of critical hardware and consumables required to support crew will pose a big stowage challenge. This includes the hardware for the collection and storage of human metabolic solid waste. The amount of stowage needed for this hardware both before (empty) and after (full) use will be a significant burden on the overall spacecraft habitable volume, layout, and design. To help with this challenge, the National Aeronautics and Space Administration (NASA) Mars Campaign Office (MCO) Logistics Reduction (LR) Portfolio has developed a collapsible canister for the collection and containment of fecal deposits. The Alternate Fecal Canister (AFC) is a collapsible alternative to the exploration toilet Hard-sided Fecal Canister (HFC). The AFC in its empty state has a volumetric benefit to smaller vehicles on longer missions. The current designs for HFC and AFC were tested with human fecal material for odor containment at White Sands Test Facility (WSTF) where the tests on both were unsuccessful. The source of the lack of containment was isolated to a gasket used on both HFC and AFC. The gasket used was found to be open cell in design. This paper provides a summary of the materials selection and testing process to identify a replacement gasket material with the intention to replace the gaskets on both existing units as well as incorporate it into the designs going forward for future builds for exploration. Details will be provided on the design of the canisters interface with the odor bacteria lid which led to the selection of the thickness of the desired replacement. Finally, the paper will provide an update on the testing in advance of a return to WSTF for final testing and detail plans to complete testing and perform a demonstration on ISS with UWMS.

ECLSS

Final Report Document: Microgravity Medical Eyewash B

Senior Capstone Design Team 15 has been commissioned by the National Aeronautics and Space Administration (NASA) to redesign the current microgravity eye wash station. The current design exhibits four primary limitations: single-use operation, excessive mass and volume, operational complexity requiring coordination with external systems, and dependence on frequent Earth resupply missions. Our updated eyewash design will be deployed on long-range space missions that could last multiple years. Based on these and other requirements from our customer, we have developed our updated eyewash design. Our compact, single-eye system uses capillary-driven flow and a free-floating water ball. This design allows us to eliminate pumps and bulky tubing, decreasing the mass and volume of the overall system. The containment eyecup is held to the astronaut's face with a strap, and a silicone seal prevents leakage while improving user comfort. Contaminated water is contained within a disposal bag containing wicking material to pull it back out of the eyecup after washing the eye. This system is reusable, efficient, and easy to activate quickly. We evaluated our design through calculations, microfluidic testing, and user try-on testing to verify our requirements. Our work demonstrated that steady-state flow was capable with our capillary framework, achieving 1.31 L/min. The prototype construction confirmed mass and volume reductions, and try-on-testing evaluated the ability to put on the system quickly. Almost all major design requirements were achieved, and water loss could be validated by testing in microgravity. Our design went through a number of iterations to reach the final solution presented in this report. These changes were driven by our testing and collaboration from each member of the team. Updated models optimized tube placement and geometry of the eyecup to better direct flow as it pools across the eye. Changes to our tubing bends improved capillary efficiency and increased the flow rate we were capable of achieving. And improved bracket placements adjusted the fit, comfort, and seal of the eyecup to the astronaut's face. Our capillary-based eyewash system is technically feasible and has been theoretically validated to operate effectively in microgravity conditions. Testing and analysis indicate that it can meet or exceed the required performance metrics, including flow rate and safety constraints. Overall, the design represents a viable alternative to current ISS-dependent eyewash systems for future space missions.

Jeffrey Allen

Investigation of Bipropellant Plume-Induced Contamination Effects on Coverglass Materials

Contamination and degradation of external spacecraft materials by unburned and partially combusted species from bipropellant thruster plumes has long been observed as a key component of the induced space environment. Space shuttle flight experiments and returned flight hardware from the International Space Station (ISS) have both experienced microscopic impact features induced by high-velocity thruster plume droplets. Analytical results have shown that droplet impingement angle relative to a receiving surface plays a key role in the surface damage. Although impacts with normal impingement angles contribute more severely to surface degradation than highly oblique angles, surface effects at higher impingement angles should not be dismissed. Thruster plume-induced materials degradation is a complex phenomenon that depends on a variety of parameters, including but not limited to material type, system temperature and pressure, plume composition, and thruster firing specifications such as number of pulses, pulse duration, and sample distance from the thruster. For space applications, attaining the vacuum pressure and temperature conditions necessary for flight-like plume expansion and exposure conditions is not a trivial task. The German Aerospace Center (Deutsches Zentrum für Luft- und Raumfahrt, DLR) is a facility uniquely capable of simulating such conditions. Test coupons were exposed to bipropellant thruster firings under high vacuum at the DLR facility. Percent area coverage (PAC) and droplet size distributions were evaluated for the uncoated and coated solar array coverglass materials over a range of impingement angles (0̊ to 75̊). A post-test imaging workflow was developed that aimed to quantify changes in sample surface morphology obtained from scanning electron microscopy (SEM) images using the Image Processing and Analysis in Java (ImageJ) tool; an opensource image processing software. The goal was to create a framework through which to evaluate the effect of bipropellant-induced PAC and droplet size distribution on solar array coverglass optical transmission losses. Understanding this relationship is important because optical transmission losses are known to lead to current reduction in solar power generation systems. In addition to the development of surface characterization workflows, valuable lessons learned as they pertain to future investigations and experiments will be discussed. The authors hope that sharing these lessons will facilitate more utilization of DLR’s unique capabilities as well as open the conversation for how best to address experimental characterization of flight-like plume expansion and its impacts on materials surface degradation effects.

Gateway