Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ignition probability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A new metric of the low-mode asymmetry for ignition target designs

In the deuterium-tritium inertial confinement fusion implosion experiments on the National Ignition Facility, the measured neutron yield and hot spot pressure are significantly lower than simulations. Understanding the underlying physics of the deficit is essential to achieving ignition. This paper investigates the low-mode areal density asymmetry in the main fuel of ignition capsule. It is shown that the areal density asymmetry breaks up the compressed shell and significantly reduces the conversion of implosion kinetic energy to hot spot internal energy, leading to the calculated hot spot pressure and neutron yield quite close to the experimental data. This indicates that the low-mode shell areal density asymmetry can explain part of the large discrepancy between simulations and experiments. Since only using the hot spot shape term could not adequately characterize the effects of the shell areal density asymmetry on implosion performance, a new metric of the low-mode asymmetry is developed to accurately measure the probability of ignition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Verification of Material Flammability in Space

The flammability in microgravity of three US-furnished materials, Delrin, polymethylmethacrylate (PMMA), and high-density polyethylene, was determined using a Russian-developed combustion tunnel on Mir. Four 4.5-mm-diameter cylindrical samples of each plastic were ignited under concurrent airflow (in the direction of flame spread) with velocities from no flow to 8.5 cm/s. The test results identify a limiting air-flow velocity V(sub lim) for each material, below which combustion ceases. Nominal values are V(sub lim) < 0.3 cm/s for Delrin, 0.5 cm/s for PMMA, and 0.3 to 0.5 cm/s for polyethylene. These values are lower than those obtained in prior ground testing. Nevertheless, they demonstrate that flow shutoff is effective for extinguishment in the microgravity environment of spacecraft. Microgravity test results also show that the plastic materials maintain a stable melt ball within the spreading flame zone. In general, as the concurrent flow velocity V decreases, the flame-spread rate V(sub F) decreases, from an average (for all three materials) of V(sub F)= 0.5-0.75 mm/s at V = 8.5 cm/s to V(sub F)= 0.05-0.01 mm/s at V = 0.3-0.5 cm/s. Also, as V decreases, the flames become less visible but expand, increasing the probability of igniting an adjacent surface.

Ivanov, A. V.↗

EVIDENCE FOR ASYMMETRIC DISTRIBUTION OF CIRCUMSTELLAR MATERIAL AROUND TYPE Ia SUPERNOVAE

We study the properties of low-velocity material in the line of sight toward nearby Type Ia supernovae (SNe Ia) that have measured late phase nebular velocity shifts (v{sub neb}), thought to be an environment-independent observable. We have found that the distribution of equivalent widths of narrow blended Na I D1 and D2 and Ca II H and K absorption lines differs significantly between those SNe Ia with negative and positive v{sub neb}, with generally stronger absorption for SNe Ia with v{sub neb} {>=} 0. A similar result had been found previously for the distribution of colors of SNe Ia, which was interpreted as a dependence of the temperature of the ejecta with viewing angle. Our work suggests that (1) a significant part of these differences in color should be attributed to extinction, (2) this extinction is caused by an asymmetric distribution of circumstellar material (CSM), and (3) the CSM absorption is generally stronger on the side of the ejecta opposite to where the ignition occurs. Since it is difficult to explain (3) via any known physical processes that occur before explosion, we argue that the asymmetry of the CSM is originated after explosion by a stronger ionizing flux on the side of the ejecta where ignition occurs, probably due to a stronger shock breakout and/or more exposed radioactive material on one side of the ejecta. This result has important implications for both progenitor and explosion models.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of Surface Skidding Response of PBX 9501 and PBX 9502

Introduction: Assess the hazards of handling polymer bonder explosives(PBX) for the case of skidding with grit particles in the frictional interface. High explosive (HE) materials tested: PBX 9501 and 9502. High melting point materials at the skidding interface between HE and a substrate is known to increase the probability of ignition by creating hot spots not subject to reduced heating from the melting of HE material. Skidding occurred at peak forces of 6-26 kN normal force, and 0.6-3.4 kN of frictional force. Velocities for skidding range from 5-30 m/s, see figure 7. Sparse amounts of 300 μm silica grit is applied loosely to the HE surface before testing. Previous works have tested ignition by grit. Testing parameters include angle of impact, drop height, grit size, grit density, substrate material. This study focuses on pre ignition conditions and detailed thermal imaging of the frictional interface. Conclusions: Temperature hot spots were observed at high points in HE surface topology. These high points may be created by grit particles. Since these points impact first high frictional work is concentrated and quickly increases temperature. Small amounts of grit do not affect the overall frictional force but do concentrate the frictional work to create hot spots.

36 MATERIALS SCIENCE↗

Combustion Processes in the Aerospace Environment

The aerospace environment introduces new and enhanced fire hazards because the special atmosphere employed may increase the frequency and intensity of fires, because the confinement associated with aerospace systems adversely affects the dynamics of fire development and control, and because the hostile external environments limit fire control and rescue operations. Oxygen enriched atmospheres contribute to the fire hazard in aerospace systems by extending the list of combustible fuels, increasing the probability of ignition, and increasing the rates of fire spread and energy release. A system for classifying atmospheres according to the degree of fire hazard, based on the heat capacity of the atmosphere per mole of oxygen, is suggested. A brief exploration of the dynamics of chamber fires shows that such fires will exhibit an exponential growth rate and may grow to dangerous size in a very short time. Relatively small quantities of fuel and oxygen can produce a catastrophic fire in a closed chamber.

Huggett, Clayton↗

Temporally resolved planar measurements of transient phenomena in a partially pre-mixed swirl flame in a gas turbine model combustor

This paper presents observations and analysis of the time-dependent behavior of a 10 kW partially pre-mixed, swirl-stabilized methane-air flame exhibiting self-excited thermo-acoustic oscillations. This analysis is based on a series of measurements wherein particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF) of the OH radical were performed simultaneously at 5 kHz repetition rate over durations of 0.8 s. Chemiluminescence imaging of the OH{sup *} radical was performed separately, also at 5 kHz over 0.8 s acquisition runs. These measurements were of sufficient sampling frequency and duration to extract usable spatial and temporal frequency information on the medium to large-scale flow-field and heat-release characteristics of the flame. This analysis is used to more fully characterize the interaction between the self-excited thermo-acoustic oscillations and the dominant flow-field structure of this flame, a precessing vortex core (PVC) present in the inner recirculation zone. Interpretation of individual measurement sequences yielded insight into various physical phenomena and the underlying mechanisms driving flame dynamics. It is observed for this flame that location of the reaction zone tracks large-scale fluctuations in axial velocity and also conforms to the passage of large-scale vortical structures through the flow-field. Local extinction of the reaction zone in regions of persistently high principal compressive strain is observed. Such extinctions, however, are seen to be self healing and thus do not induce blowout. Indications of auto-ignition in regions of unburned gas near the exit are also observed. Probable auto-ignition events are frequently observed coincident with the centers of large-scale vortical structures, suggesting the phenomenon is linked to the enhanced mixing and longer residence times associated with fluid at the core of the PVC as it moves through the flame. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrodynamic instabilities in beryllium targets for the National Ignition Facility

Beryllium ablators offer higher ablation velocity, rate, and pressure than their carbon-based counterparts, with the potential to increase the probability of achieving ignition at the National Ignition Facility (NIF) [E. I. Moses et al., Phys. Plasmas 16, 041006 (2009)]. We present here a detailed hydrodynamic stability analysis of low (NIF Revision 6.1) and high adiabat NIF beryllium target designs. Our targets are optimized to fully utilize the advantages of beryllium in order to suppress the growth of hydrodynamic instabilities. This results in an implosion that resists breakup of the capsule, and simultaneously minimizes the amount of ablator material mixed into the fuel. We quantify the improvement in stability of beryllium targets relative to plastic ones, and show that a low adiabat beryllium capsule can be at least as stable at the ablation front as a high adiabat plastic target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Auto-ignition during instationary jet evolution of dimethyl ether (DME) in a high-pressure atmosphere

The auto-ignition process during transient injection of gaseous dimethyl ether (DME) in a constant high-pressure atmosphere is studied experimentally by laser-optical methods and compared with numerical calculations. With different non-intrusive measurement techniques jet properties and auto-ignition are investigated at high temporal and spatial resolution. The open jet penetrates a constant pressure oxidative atmosphere of up to 4 MPa. During the transient evolution, the fuel jet entrains air at up to 720 K. The subsequent auto-ignition of the ignitable part of the jet occurs simultaneously over a wide spatial extension. The ignition delay times are not affected by variation of the nozzle exit velocity. Thus, the low-temperature oxidation is slow compared with the shorter time scales of mixing, so that chemical kinetics is dominating the process. The typical two-stage ignition is resolved optically with high-speed shadowgraphy at a sampling rate of 10 kHz. The 2D fields of jet velocity and transient mixture fraction are measured phase-coupled with Particle Image Velocimetry (PIV) and Tracer Laser Induced Fluorescence (LIF) during the time-frame of ignition. The instationary Probability Density Functions (PDF) of mixture fraction are described very well by Beta functions within the complete area of the open jet. Additional 1D flamelet simulations of the auto-ignition process are computed with a detailed reaction mechanism for DME [S. Fischer, F. Dryer, H. Curran, Int. J. Chem. Kinet. 32 (12) (2000) 713-740; H. Curran, S. Fischer, F. Dryer, Int. J. Chem. Kinet. 32 (12) (2000) 741-759]. Calculated ignition delay times are in very good agreement with the measured mean ignition delay times of 3 ms. Supplemental flamelet simulations address the influence of DME and air temperature, pressure and strain. Underneath a critical strain rate the air temperature is identified to be the most sensitive factor on ignition delay time. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Investigation to Improve Quality Evaluations of Primers and Propellant for 20mm Munitions

To reduce the frequency of electrically initiated, 20mm munition hangfires (delayed ignitions), a joint Army/NASA investigation was conducted to recommend quality evaluation improvements for acceptance of both primers and gun propellant. This effort focused only on evaluating ignition and combustion performance as potential causes of hangfires: poor electrical initiation of the primer, low output performance of the primer, low ignition sensitivity of the gun propellant, and the effects of cold temperature. The goal was to determine the "best" of the Army and NASA test methods to assess the functional performance of primers and gun propellants. The approach was to evaluate the performance of both high-quality and deliberately defective primers to challenge the sensitivity of test methods. In addition, the ignition sensitivity of different manufacturing batches of gun propellants was evaluated. The results of the investigation revealed that improvements can be made in functional evaluations that can assist in identifying and reducing ignition and performance variations. The "best" functional evaluation of primers and propellant is achieved through a combination of both Army and NASA test methods. Incorporating the recommendations offered in this report may provide for considerable savings in reducing the number of cartridge firings, while significantly lowering the rejection rate of primer, propellant and cartridge lots. The most probable causes for ignition and combustion-related hangfires were the lack of calcium silicide in the primer mix, a low output performance of primers, and finally, poor ignition sensitivity of gun propellant. Cold temperatures further reduce propellant ignition sensitivity, as well as reducing burn rate and chamber pressures.

Bement, L. J.↗

On The Deflagration to Detonation Transition in 1.65 g cm -3 Pentaerythritol Tetranitrate

The LANL Weapons Response Group is charged with making determinations for a wide range of scenarios regarding the probability that inadvertent ignition of the high explosive (HE) components might cause nuclear yield, or dispersal of special nuclear material, during assembly/disassembly operations at the Pantex Plant. These scenarios are categorized based on the nature of the ignition causing stimulus, i.e. impact, electrostatic discharge, pressure-shear, etc. However, for all of these scenarios, regardless of how ignition is achieved, there must also be a credible path for the burning HE to transition to detonation for yield or dispersal to occur. If it can be determined that there is no feasible path for deflagration-to-detonation transition (DDT), the scenario space that requires mitigative action is greatly reduced. The strategy to support Weapons Response determinations is to use experimentation and observation to evaluate HE response in severe “overtest” configurations. To increase with confidence in the margins of HE response, these overtests are designed, by controlling parameters known to enhance HE response violence, to be more severe than what is ever encountered in the actual operations environment at the Plant. This study is focused on DDT in pentaerythritol tetranitrate (PETN), a high explosive that is used in LANL’s detonators. PETN is known to be able to DDT at certain densities, and this represents a safety concern. The PETN in LANL’s detonators is commonly a density of 1.65 g cm -3 . However, DDT has never been observed at this density in PETN. In this work, we studied the DDT reaction in 1.65 g cm -3 PETN to determine whether DDT is possible at this density, and if so, what length of PETN is required for the transition to occur. In any of the tests conducted, we did not observe DDT in 1.65 g cm -3 PETN. It is possible that the DDT length for 1.65 g cm -3 PETN is greater than 6” (the available run length in the experiments), but this length is simply not available in a detonator, and is therefore not a concern.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Pyrotechnic hazards classification and evaluation program. Phase 2, segment 3: Test plan for determining hazards associated with pyrotechnic manufacturing processes

A comprehensive test plan for determining the hazards associated with pyrotechnic manufacturing processes is presented. The rationale for each test is based on a systematic analysis of historical accounts of accidents and a detailed study of the characteristics of each manufacturing process. The most hazardous manufacturing operations have been determined to be pressing, mixing, reaming, and filling. The hazard potential of a given situation is evaluated in terms of the probabilities of initiation, communication, and transition to detonation (ICT). The characteristics which affect the ICT probabilities include the ignition mechanisms which are present either in normal or abnormal operation, the condition and properties of the pyrotechnic material, and the configuration of the processing equipment. Analytic expressions are derived which describe the physical conditions of the system, thus permitting a variety of processes to be evaluated in terms of a small number of experiments.

Source record↗

Probability density function treatment of turbulence/chemistry interactions during the ignition of a temperature-stratified mixture for application to HCCI engine modeling

Homogeneous charge compression ignition (HCCI) engine technology promises to reduce NO{sub x} and soot emissions while achieving high thermal efficiency. Temperature and mixture stratification are regarded as effective means of controlling the start of combustion and reducing the abrupt pressure rise at high loads. Probability density function methods are currently being pursued as a viable approach to modeling the effects of turbulent mixing and mixture stratification on HCCI ignition. In this paper we present an assessment of the merits of three widely used mixing models in reproducing the moments of reactive scalars during the ignition of a lean hydrogen/air mixture ({phi}=0.1, p=41atm, and T=1070 K) under increasing temperature stratification and subject to decaying turbulence. The results from the solution of the evolution equation for a spatially homogeneous joint PDF of the reactive scalars are compared with available direct numerical simulation (DNS) data [E.R. Hawkes, R. Sankaran, P.P. Pebay, J.H. Chen, Combust. Flame 145 (1-2) (2006) 145-159]. The mixing models are found able to quantitatively reproduce the time history of the heat release rate, first and second moments of temperature, and hydroxyl radical mass fraction from the DNS results. Most importantly, the dependence of the heat release rate on the extent of the initial temperature stratification in the charge is also well captured. (author)

33 ADVANCED PROPULSION SYSTEMS↗

IGNITION AND FRONTIER SCIENCE ON THE NATIONAL IGNITION FACILITY

The National Ignition Facility (NIF), the world's largest and most powerful laser system for inertial confinement fusion (ICF) and experiments studying high-energy-density (HED) science, is now operational at Lawrence Livermore National Laboratory (LLNL). The NIF construction Project was certified by the Department of Energy as complete on March 30, 2009. NIF, a 192-beam Nd-glass laser facility, will produce 1.8 MJ, 500 TW of light at the third-harmonic, ultraviolet light of 351 nm. On March 10, 2009, a total 192-beam energy of 1.1 MJ was demonstrated; this is approximately 30 times more energy than ever produced in an ICF laser system. The principal goal of NIF is to achieve ignition of a deuterium-tritium (DT) fuel capsule and provide access to HED physics regimes needed for experiments related to national security, fusion energy and for broader frontier scientific exploration. NIF experiments in support of indirect drive ignition will begin in FY2009. These first experiments represent the next phase of the National Ignition Campaign (NIC). The NIC is a 1.7 billion dollar national effort to achieve fusion ignition and is coordinated through a detailed execution plan that includes the science, technology, and equipment. Equipment required for ignition experiments include diagnostics, cryogenic target manipulator, and user optics. Participants in this effort include LLNL, General Atomics (GA), Los Alamos National Laboratory (LANL), Sandia National Laboratory (SNL), and the University of Rochester Laboratory for Energetics (LLE). The primary goal for NIC is to have all of the equipment operational and integrated into the facility and be ready to begin a credible ignition campaign in 2010. With NIF now operational, the long-sought goal of achieving self-sustained nuclear fusion and energy gain in the laboratory is much closer to realization. Successful demonstration of ignition and net energy gain on NIF will be a major step towards demonstrating the feasibility of Inertial Fusion Energy (IFE) and will likely focus the world's attention on the possibility of an ICF energy option. NIF experiments to demonstrate ignition and gain will use central-hot-spot (CHS) ignition, where a spherical fuel capsule is simultaneously compressed and ignited. The scientific basis for CHS has been intensively developed and has high probability of success. Achieving ignition with CHS will open the door for other advanced concepts, such as the use of high-yield pulses of visible wavelength rather than ultraviolet and Fast Ignition concepts. Moreover, NIF will have important scientific applications in such diverse fields as astrophysics, nuclear physics and materials science. The NIC will develop the full set of capabilities required to operate NIF as a major national and international user facility. A solicitation for NIF frontier science experiments to be conducted by the academic community is planned for summer 2009. This paper summarizes the design, performance, and status of NIF, experimental plans for NIC, and will present a brief discussion of the unparalleled opportunities to explore frontier basic science that will be available on the NIF.

42 ENGINEERING↗

The relative influence of climate and housing development on current and projected future fire patterns and structure loss across three California landscapes

Climate and land use patterns are expected to change dramatically in the coming century, raising concern about their effects on wildfire patterns and subsequent impacts to human communities. The relative influence of climate versus land use on fires and their impacts, however, remains unclear, particularly given the substantial geographical variability in fire-prone places like California. Here, we developed a modeling framework to compare the importance of climatic and human variables for explaining fire patterns and structure loss for three diverse California landscapes, then projected future large fire and structure loss probability under two different climate (hot-dry or warm-wet) and two different land use (rural or urban residential growth) scenarios. The relative importance of climate and housing pattern varied across regions and according to fire size or whether the model was for large fires or structure loss. The differing strengths of these relationships, in addition to differences in the nature and magnitude of projected climate or land use change, dictated the extent to which large fires or structure loss were projected to change in the future. Despite this variability, housing and human infrastructure were consistently more responsible for explaining fire ignitions and structure loss probability, whereas climate, topography, and fuel variables were more important for explaining large fire patterns. For all study areas, most structure loss occurred in areas with low housing density (from 0.08 to 2.01 units/ha), and expansion of rural residential land use increased structure loss probability in the future. Regardless of future climate scenario, large fire probability was only projected to increase in the northern and interior parts of the state, whereas climate change had no projected impact on fire probability in southern California. Given the variation in fire-climate relationships and land use effects, policy and management decision-making should be customized for specific geographical regions.

54 ENVIRONMENTAL SCIENCES↗

Predicting fusion ignition at the National Ignition Facility with physics-informed deep learning

Here, an inertial confinement fusion experiment, carried out at the National Ignition Facility, has achieved ignition by generating fusion energy exceeding the laser energy that drove the experiment. Prior to the experiment, a generative machine learning model that combines radiation hydrodynamics simulations, deep learning, experimental data, and Bayesian statistics was used to predict, with a probability greater than 70%, that ignition was the most likely outcome for this shot.

Spears, Brian K. [Lawrence Livermore National Labo↗

Rarefied xenon flow in orificed hollow cathodes

A parametric study is conducted to quantify the effect of the keeper electrode geometry on the xenon neutral flow quantities within orificed hollow cathodes, prior to ignition. The keeper impinges directly on the flow out of the cathode orifice and its geometry influences the product between the pressure in the orifice–keeper region and the cathode-to-keeper distance. A representative cathode is simulated using the Direct Simulation Monte Carlo method. The numerical model is first validated with computational results from the literature. A parametric study is then conducted. Parameters include the cathode pressure–diameter in the range of 1–5 Torr cm and the following geometric ratios (and ranges): cathode orifice-to-inner radii (0.1–0.7), keeper orifice-to-cathode orifice radii (1–5), and keeper distance-to-cathode-orifice diameter (0.5–10). It is found that, if both keeper and cathode have identical orifice radii, the flow remains subsonic in the orifice-to-keeper region. In most cases, however, the flow becomes underexpanded and supersonic, and the static pressure within the orifice-to-keeper region is, on average, 4% that of the upstream pressure value. The orifice–keeper region pressure increases with either a decrease in the keeper orifice diameter or an increase in the distance between cathode and keeper, in agreement with literature data. Both trends are explained through conservation laws. A statistical study of numerical results reveals that the ratio of ignition-to-nominal mass flow rates has a most probable value of 50, which suggests that heaterless cathode ignition at a minimum DC voltage may be achieved by increasing the input mass flow rate by a factor of 50.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗