Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image Comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Summary: SEE4GEO

The seismoelectric effects technique (SEE) is a new and innovative approach for geothermal subsurface imaging and monitoring at reservoir scale. The objective of this project is to assess SEE in terms of data acquisition, cost and quality, and to determine its capability in comparison with classical imaging and monitoring techniques, particularly decoupled seismic and electromagnetic methods. This will be achieved by (1) development of a fast, true 3D numerical package, handling SEE imaging and subsurface properties characterization, including resistivity and permeability, (2) laboratory experiments performed in a controlled environment to define optimal deployment design, data quality, and inform field deployment, and (3) field surveys to ultimately test and draw lessons for practical use of SEE technology. There is a relatively extensive body of work in the literature on SEE, and members of this consortium have been involved in theoretical and numerical development of SEE modeling as well as laboratory experiments. Nevertheless, to our knowledge few, if any, documented efforts have been specifically targeting the use of SEE for geothermal subsurface imaging and monitoring. The strength and originality of our proposal rely on an integrated approach leveraging numerical, laboratory and field experiments, to properly document the practical use of SEE. Through this process, SEE in-hand technology for the geothermal industry will be able to progress from a TRL 1 to TRL 3.

58 GEOSCIENCES↗

Seismoelectric Effects for Geothermal Resources Assessment and Monitoring (SEE4GEO)

The seismoelectric effects technique (SEE) is a new and innovative approach for geothermal subsurface imaging and monitoring at reservoir scale. The objective of this project is to assess SEE in terms of data acquisition, cost and quality, and to determine its capability in comparison with classical imaging and monitoring techniques, particularly decoupled seismic and electromagnetic methods. This will be achieved by (1) development of a fast, true 3D numerical package, handling SEE imaging and subsurface properties characterization, including resistivity and permeability, (2) laboratory experiments performed in a controlled environment to define optimal deployment design, data quality, and inform field deployment, and (3) field surveys to ultimately test and draw lessons for practical use of SEE technology. There is a relatively extensive body of work in the literature on SEE, and members of this consortium have been involved in theoretical and numerical development of SEE modeling as well as laboratory experiments. Nevertheless, to our knowledge few, if any, documented efforts have been specifically targeting the use of SEE for geothermal subsurface imaging and monitoring. The strength and originality of our proposal rely on an integrated approach leveraging numerical, laboratory and field experiments, to properly document the practical use of SEE. Through this process, SEE in-hand technology for the geothermal industry will be able to progress from a TRL 1 to TRL 3.

58 GEOSCIENCES↗

Accuracy of Tau Positron Emission Tomography as a Prognostic Marker in Preclinical and Prodromal Alzheimer Disease: A Head-to-Head Comparison Against Amyloid Positron Emission Tomography and Magnetic Resonance Imaging

Importance: Tau positron emission tomography (PET) tracers have proven useful for the differential diagnosis of dementia, but their utility for predicting cognitive change is unclear. Objective: To examine the prognostic accuracy of baseline fluorine 18 ( 18 F)-flortaucipir and [18F]RO948 (tau) PET in individuals across the Alzheimer disease (AD) clinical spectrum and to perform a head-to-head comparison against established magnetic resonance imaging (MRI) and amyloid PET markers. Design, setting, and participants: This prognostic study collected data from 8 cohorts in South Korea, Sweden, and the US from June 1, 2014, to February 28, 2021, with a mean (SD) follow-up of 1.9 (0.8) years. A total of 1431 participants were recruited from memory clinics, clinical trials, or cohort studies; 673 were cognitively unimpaired (CU group; 253 [37.6%] positive for amyloid-β [Aβ]), 443 had mild cognitive impairment (MCI group; 271 [61.2%] positive for Aβ), and 315 had a clinical diagnosis of AD dementia (315 [100%] positive for Aβ). Exposures: [ 18 F]Flortaucipir PET in the discovery cohort (n = 1135) or [ 18 F]RO948 PET in the replication cohort (n = 296), T1-weighted MRI (n = 1431), and amyloid PET (n = 1329) at baseline and repeated Mini-Mental State Examination (MMSE) evaluation. Main outcomes and measures: Baseline [ 18 F]flortaucipir/[ 18 F]RO948 PET retention within a temporal region of interest, MRI-based AD-signature cortical thickness, and amyloid PET Centiloids were used to predict changes in MMSE using linear mixed-effects models adjusted for age, sex, education, and cohort. Mediation/interaction analyses tested whether associations between baseline tau PET and cognitive change were mediated by baseline MRI measures and whether age, sex, and APOE genotype modified these associations. Results: Among 1431 participants, the mean (SD) age was 71.2 (8.8) years; 751 (52.5%) were male. Findings for [ 18 F]flortaucipir PET predicted longitudinal changes in MMSE, and effect sizes were stronger than for AD-signature cortical thickness and amyloid PET across all participants (R 2 , 0.35 [tau PET] vs 0.24 [MRI] vs 0.17 [amyloid PET]; P < .001, bootstrapped for difference) in the Aβ-positive MCI group (R2, 0.25 [tau PET] vs 0.15 [MRI] vs 0.07 [amyloid PET]; P < .001, bootstrapped for difference) and in the Aβ-positive CU group (R 2 , 0.16 [tau PET] vs 0.08 [MRI] vs 0.08 [amyloid PET]; P < .001, bootstrapped for difference). These findings were replicated in the [ 18 F]RO948 PET cohort. MRI mediated the association between [ 18 F]flortaucipir PET and MMSE in the groups with AD dementia (33.4% [95% CI, 15.5%-60.0%] of the total effect) and Aβ-positive MCI (13.6% [95% CI, 0.0%-28.0%] of the total effect), but not the Aβ-positive CU group (3.7% [95% CI, -17.5% to 39.0%]; P = .71). Age (t = -2.28; P = .02), but not sex (t = 0.92; P = .36) or APOE genotype (t = 1.06; P = .29) modified the association between baseline [ 18 F]flortaucipir PET and cognitive change, such that older individuals showed faster cognitive decline at similar tau PET levels. Conclusions and relevance: The findings of this prognostic study suggest that tau PET is a promising tool for predicting cognitive change that is superior to amyloid PET and MRI and may support the prognostic process in preclinical and prodromal stages of AD.

59 BASIC BIOLOGICAL SCIENCES↗

Real-time damage characterization for GFRCs using high-speed synchrotron X-ray phase contrast imaging

Here, we report the application of high-speed synchrotron X-ray phase contrast imaging (PCI) in real-time damage characterization for glass fiber reinforced composites (GFRCs) subjected to dynamic loading. Dynamic single-edge notched bending (DSENB) experiments on pre-notched S-2 GFRCs were performed on a modified Kolsky compression bar. During loading, the synchrotron X-ray beam penetrated through the composite specimen from the side to detect damage evolution inside the material. Entire dynamic events were recorded by a high-speed camera as image sequences.0° and 90° unidirectional and cross-ply composites were investigated. An optical imaging technique was also employed to capture similar dynamic events in comparison with the radiographic imaging. It is demonstrated that high-speed X-ray PCI had sufficient phase contrast to characterize a crack initiation at a 20-μm spatial resolution within 920 ns and track the crack geometry during propagation, thereby providing reliable data to quantify the dynamic damage resistance of GFRCs. Furthermore, being capable of recognizing microscopic damage-related features at a sub-10-μm resolution, high-speed X-ray PCI provided fundamental material failure mechanisms to reveal the essential of macroscale structural failure of composites. It can also track the damage evolution inside and between individual plies of laminated composites. However, current high-speed X-ray PCI technique only supports in-situ observation and the high timing and spatial resolutions are limited within a field of view of ~2.5 mm in square, preventing its application in the three-dimensional and larger-area damage detection for GFRC structures.

42 ENGINEERING↗

Insights into the relation between vertical cloud structure and dynamics of three polar lows: Observations from COMBLE

The vertical structure of three polar lows is described using profiling radar, lidar, and passive remote sensors deployed at a coastal site in northern Norway. The data were collected as part of the Cold-air Outbreaks in the Marine Boundary Layer Experiment (COMBLE). These data are examined in the context of satellite imagery, operational weather radar reflectivity imagery, and output from the AROME-Arctic model. A comparison to satellite images shows that AROME-Arctic captured the polar lows well. All three polar lows form in marine cold-air outbreaks and are surrounded by open-cellular convection typical of such outbreaks. Two of the lows form in a forward shear environment, and one under reverse shear. Initially, the three polar lows are comma-shaped; two of them transition to be more spirali-form at their mature stage and have mostly cloud-free warm cores. The warm cores are the result of a warm-seclusion process. All three lows have stratiform precipitation bands, marked by little cloud liquid water, and rather high surface precipitation rate. The vertical drafts and turbulence in these stratiform clouds are generally weak. In conclusion, all three lows also have convective clouds, which have stronger vertical drafts, stronger turbulence, and pockets of high liquid water content.

54 ENVIRONMENTAL SCIENCES↗

Topologically derived dislocation theory for twist and stretch moiré superlattices in bilayer graphene

In this work, we develop a continuum dislocation description of twist and stretch moiré superlattices in two-dimensional material bilayers. The continuum formulation is based on the topological constraints introduced by the periodic dislocation network associated with the moiré structure. The approach is based on solving analytically for the structural distortion and displacement fields that satisfy the topological constraints and that minimize the total energy. The total energy is described by both the strain energy of each individual distorted layer and a Peierls-Nabarro-like interfacial contribution arising from stacking disregistry. The dislocation core emerges naturally within the formalism as a result of the competition between the two contributions. The approach presented here captures the structure and energetics of twist and stretch moiré superlattices of dislocations with arbitrary direction and character, without assuming an analytical solution a priori and while accounting naturally for dislocation-dislocation image interactions. In comparisons to atomistic simulations using classical potentials, the maximum structure deviation is 6%, while the maximum line energy deviation is 0.019 eV/Å. Several applications of our model are shown, including predicting the variation of structure with twist angle and describing dislocation line tension and junction energies.

36 MATERIALS SCIENCE↗

Cross-section SEM-EDS Analysis of Corroded 316 Steel Samples Using JEOL 6610 SEM

Comparison of SEM images obtained for samples 316H-1, 5, 7, and 10 revealed that samples 1 and 5 were subjected to more corrosion than the other two samples. Pores of an average of 1µm size were also observed scattered near the edge of each sample. Corrosion layer thickness was measured from edge of the corroded surface to the pore region. It was found that 316H-1 and 316H-5 had more corrosion damage with 82.40µm and 100µm respectively. Sample 316H-5 posed a challenge in measuring the corrosion layer thickness due to it breaking off from the parent sample during polishing. Samples 316H-7 and 316H-10 are less corroded with 26.57µm and 39.94µm thickness respectively.

36 - MATERIALS SCIENCE↗

Stereo-DIC Challenge 1.0 – Rigid Body Motion of a Complex Shape

Background Stereo-DIC is a widely used optical measurement technique that provides a dense full-field 3D measurement of the shape, displacement, and strain of a solid sample. When compared with 2D-DIC, Stereo-DIC provides greater flexibility and expands its use beyond flat, planar specimens. Furthermore, the widespread availability of commercial systems has led to the adoption of the technique throughout industry, academia, and government research labs. Objective Even though some research has been done to understand the effects of different experimental and stereo-DIC parameters, no reference is available to benchmark and compare the performance of current stereo-DIC algorithms to each other. Methods This paper provides the description and analysis of a carefully controlled 3D experiment and associated images used to compare the results from five subset based DIC software packages. Both the images and analysis codes used in this paper to compare the results are described here and are available for download and use for continued research. Results We show that over a very large range of motion, the 3D errors are very small, less than 80μm over a travel of ±20 mm out-of-plane and ±20 mm in-plane. While all codes performed similarly, there are important differences noted in the paper. Conclusion The image sets and results comparison software are hosted by the International DIC Society (www.iDICs.org) and are freely available for download and analysis for comparison with results in this paper. Furthermore, it is hoped that this set of images can be used for future research in improving stereo-DIC by future authors.

Algorithms comparison↗

Electron image contrast analysis of mosaicity in rutile nanocrystals using direct electron detection

Direct electron detection provides high detective quantum efficiency, significantly improved point spread function and fast read-out which have revolutionized the field of cryogenic electron microscopy. However, these benefits for high-resolution electron microscopy (HREM) are much less exploited, especially for in situ study where major impacts on crystallographic structural studies could be made. By using direct detection in electron counting mode, rutile nanocrystals have been imaged at high temperature inside an environmental transmission electron microscope. The improvements in image contrast are quantified by comparison with a charge-coupled device (CCD) camera and by image matching with simulations using an automated approach based on template matching. Together, these approaches enable a direct measurement of 3D shape and mosaicity (~1°) of a vacuum-reduced TiO 2 nanocrystal about 50 nm in size. Thus, this work demonstrates the possibility of quantitative HREM image analysis based on direct electron detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lensing without borders – I. A blind comparison of the amplitude of galaxy–galaxy lensing between independent imaging surveys

ABSTRACT Lensing without borders is a cross-survey collaboration created to assess the consistency of galaxy–galaxy lensing signals (ΔΣ) across different data sets and to carry out end-to-end tests of systematic errors. We perform a blind comparison of the amplitude of ΔΣ using lens samples from BOSS and six independent lensing surveys. We find good agreement between empirically estimated and reported systematic errors which agree to better than 2.3σ in four lens bins and three radial ranges. For lenses with zL > 0.43 and considering statistical errors, we detect a 3–4σ correlation between lensing amplitude and survey depth. This correlation could arise from the increasing impact at higher redshift of unrecognized galaxy blends on shear calibration and imperfections in photometric redshift calibration. At zL > 0.54, amplitudes may additionally correlate with foreground stellar density. The amplitude of these trends is within survey-defined systematic error budgets that are designed to include known shear and redshift calibration uncertainty. Using a fully empirical and conservative method, we do not find evidence for large unknown systematics. Systematic errors greater than 15 per cent (25 per cent) ruled out in three lens bins at 68 per cent (95 per cent) confidence at z < 0.54. Differences with respect to predictions based on clustering are observed to be at the 20–30 per cent level. Our results therefore suggest that lensing systematics alone are unlikely to fully explain the ‘lensing is low’ effect at z < 0.54. This analysis demonstrates the power of cross-survey comparisons and provides a promising path for identifying and reducing systematics in future lensing analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-frame x-ray radiography and image tracking for quantification of expansion in laser-driven tin ejecta microjets

One regime of experimental particle-laden flow study involves ejecta microjets—often defined as a stream of micrometer-scale particles generated through shock interaction with a non-uniform surface and generally travel above 1 km/s. In order to capture the change in characteristics as a function of propagation time, we apply a multi-frame x-ray radiography platform to observe and track the jet transport dynamics. A synchrotron x-ray source allows us to perform quantitative analyses and comparisons between the eight images captured by the imaging system. Observation of a single jet through time allows the use of a cross correlation algorithm to independently track various regions within the jet and quantify the jet expansion over time using normalized area and normalized areal density values. Through a comparison with the calculated values of ballistic transport, these findings show less expansion than expected for ballistically transporting particles. In conclusion, this work combines multi-frame synchrotron radiography with image tracking to establish a foundation for future studies on jet transport and particle interaction dynamics.

Sun, Yuchen [Lawrence Livermore National Laborator↗

Segmentation method comparison for residual fiber length measurement across tiled microscopy images

Fiber length distribution (FLD), in part, governs mechanical properties in discontinuous fiber composites, yet manual measurement methods limit the high-throughput characterization needed for materials design optimization. This study compares deep learning segmentation approaches for automated FLD measurement in large-field microscopy, evaluating how method choice affects the microstructural descriptors used in structure-property-processing relationships. A critical challenge is that high-resolution microscopy images (10,000×10,000 pixels) must be tiled for deep learning analysis, fragmenting fibers at boundaries. We demonstrate that segmentation method proves crucial for measurement accuracy. For example, instance segmentation with Slicing Aided Hyper Inference (SAHI) preserves individual fiber integrity across tiles while semantic segmentation prioritizes speed. Comparing against manual measurement of extracted carbon fibers, YOLOv11-SAHI matched manual ground truth (238 μm weighted mean) with 40x speedup (4.5 vs 167 minutes per image). U-Net provides rapid quantification although it is at the cost of reduced accuracy due only reliably measuring stand-alone fibers. Our comparative analysis reveals that instance segmentation with SAHI better preserves length measurements while semantic segmentation prioritizes speed, providing empirical guidance for method selection. The characterization provides essential inputs for mechanical property prediction models and inverse design workflows, accelerating composite materials development cycles.

Additive manufacturing↗

Fluctuation cepstral scanning transmission electron microscopy of mixed-phase amorphous materials

Four-dimensional scanning transmission electron microscopy (4D-STEM) is a versatile analytical tool for characterizing materials structural properties. However, extending such analysis to disordered materials is challenging, especially in technologically important samples with mixed ordered and disordered phases. Here, in this work, we present a new 4D-STEM method, called fluctuation cepstral STEM (FC-STEM), based on the fluctuation analysis of cepstral transform of diffraction patterns. The peaks in the associated transformation relate to inter-atomic distances in a thin sample. By varying the real-space range over which fluctuations are calculated, distinct ordered and disordered phases can be mapped in a diffractive image reconstruction. We demonstrate the principles of FC-STEM by characterizing a silicon anode, harvested from a cycled lithium-ion battery. A mixture of amorphous and nanocrystalline silicon, graphitic carbon, and electrolyte by-products is identified and mapped. Comparisons with conventional electron imaging and energy-dispersive X-ray spectroscopy show that FC-STEM is highly effective for the structure determination of mixed-phase amorphous materials.

36 MATERIALS SCIENCE↗

Structural Complexities in Sodium Ion Conductive Antiperovskite Revealed by Cryogenic Transmission Electron Microscopy

Here we use low-dose cryogenic transmission electron microscopy (cryo-TEM) to investigate the atomic-scale structure of antiperovskite Na 2 NH 2 BH 4 crystals by preserving the room-temperature cubic phase and carefully monitoring the electron dose. Via quantitative analysis of electron beam damage using selected area electron diffraction, we find cryogenic imaging provides 6-fold improvement in beam stability for this solid electrolyte. Cryo-TEM images obtained from flat crystals revealed the presence of a new, long-range-ordered supercell with a cubic phase. The supercell exhibits doubled unit cell dimensions of 9.4 Å × 9.4 Å as compared to the cubic lattice structure revealed by X-ray crystallography of 4.7 Å × 4.7 Å. The comparison between the experimental image and simulated potential map indicates the origin of the supercell is a vacancy ordering of sodium atoms. This work demonstrates the potential of using cryo-TEM imaging to study the atomic-scale structure of air- and electron-beam-sensitive antiperovskite-type solid electrolytes.

36 MATERIALS SCIENCE↗

Optimizing automatic morphological classification of galaxies with machine learning and deep learning using Dark Energy Survey imaging

There are several supervised machine learning methods used for the application of automated morphological classification of galaxies; however, there has not yet been a clear comparison of these different methods using imaging data, or an investigation for maximizing their effectiveness. We carry out a comparison between several common machine learning methods for galaxy classification [Convolutional Neural Network (CNN), K-nearest neighbour, logistic regression, Support Vector Machine, Random Forest, and Neural Networks] by using Dark Energy Survey (DES) data combined with visual classifications from the Galaxy Zoo 1 project (GZ1). Our goal is to determine the optimal machine learning methods when using imaging data for galaxy classification. We show that CNN is the most successful method of these ten methods in our study. Using a sample of ~2800 galaxies with visual classification from GZ1, we reach an accuracy of ~0.99 for the morphological classification of ellipticals and spirals. The further investigation of the galaxies that have a different ML and visual classification but with high predicted probabilities in our CNN usually reveals the incorrect classification provided by GZ1. We further find the galaxies having a low probability of being either spirals or ellipticals are visually lenticulars (S0), demonstrating that supervised learning is able to rediscover that this class of galaxy is distinct from both ellipticals and spirals. We confirm that ~2.5 percent galaxies are misclassified by GZ1 in our study. After correcting these galaxies’ labels, we improve our CNN performance to an average accuracy of over 0.99 (accuracy of 0.994 is our best result).

79 ASTRONOMY AND ASTROPHYSICS↗

STEM Characterization of Dislocation Loops in Irradiated FCC Alloys

In this study, we demonstrate the methodology systematically developed for dislocation loop (perfect and faulted loops) imaging and analysis in irradiated face-centered-cubic (FCC) alloys using scanning transmission electron microscopy (STEM). On-zone [001] STEM imaging was identified as the preferred choice for its accuracy and effectiveness based on the comparison with other dislocation loop imaging techniques including: (i) on-zone STEM imaging using other major low-index zone axes, (ii) kinematic two-beam conditions bright field imaging near the [001] zone axis in conventional TEM (CTEM) mode, and (iii) Rel-Rod CTEM dark-field (DF) imaging near the [011] zone axis. The effect of STEM collection angle on the contrast formation of dislocation loops was also investigated. The developed method was confirmed by imaging all populations of perfect and faulted loops of types a/2$\langle$110$\rangle${110} and a/3$\langle$111$\rangle${111} found in an ion irradiated Ni40Fe40Cr20 alloy. The proposed STEM-based technique can easily identify said loops with a size greater than 10 nm without any assumptions such as those commonly made using the conventional Rel-Rod CTEM-DF technique. The recommended methodology in this study is developed as a quick and convenient tool that can be generally applied to irradiated FCC-based materials due to their common crystallography.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitivity calibration of a Carestream HPX-1 image plate scanner

There is a need to measure the sensitivity of the image plate scanners used to scan Z shot data. The Carestream HPX-1 image plate scanner was tested, and its performance was characterized to determine the system sensitivity in terms of signal per incident photon as a function of x-ray energy. A Manson source was used to simultaneously expose an Amptek x-ray multi-channel analyzer and image plates, allowing for a comparison of the counts as a function of energy to the signal recorded on the image plates. NIST-certified radioactive sources were used to assign an absolute sensitivity. Results indicate that the HPX-1 scanner response matches the shape of the modeled response, allowing for absolute scaling using NIST-certified radioisotope sources. The HPX-1 scanner shows a stable response with measurements taken over one week. In contrast, the sensitivity of the DITABIS scanner was characterized using the same approach, but it exhibits changes in its response that varied by more than 50% over the span of 4 days.

42 ENGINEERING↗