Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image analysis.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

SU-F-R-18: Updates to the Computational Environment for Radiological Research for Image Analysis

Purpose: To present new tools in CERR for Texture Analysis and Visualization. Method: (1) Quantitative Image Analysis: We added the ability to compute Haralick texture features based on local neighbourhood. The Texture features depend on many parameters used in their derivation. For example: (a) directionality, (b) quantization of image, (c) patch-size for the neighborhood, (d) handling of the edge voxels within the region of interest, (e) Averaging co-occurance matrix vs texture features for different directions etc. A graphical user interface was built to set these parameters and then visualize their impact on the resulting texture maps. The entire functionality was written in Matlab. Array indexing was used to speed up the texture calculation. The computation speed is very competitive with the ITK library. Moreover, our implementation works with multiple CPUs and the computation time can be further reduced by using multiple processor threads. In order to reduce the Haralick texture maps into scalar features, we propose the use of Texture Volume Histograms. This lets users make use of the entire distribution of texture values within the region of interest rather than using just the mean and the standard deviations. (2) Qualitative/Visualization tools: The derived texture maps are stored as a new scan (derived) within CERR’s planC data structure. A display that compares various scans was built to show the raw image and the derived texture maps side-by-side. These images are positionally linked and can be navigated together. CERR’s graphics handling was updated and sped-up to be compatible with the newer Matlab versions. As a result, the users can use (a) different window levels and colormaps for different viewports, (b) click-and-drag or use mouse scroll-wheel to navigate slices. Results: The new features and updates are available via https://www.github.com/adityaapte/cerr . Conclusion: Features added to CERR increase its utility in Radiomics and Outcomes modeling.

60 APPLIED LIFE SCIENCES↗

Neutron imaging analysis using jupyter Python notebook

Abstract Independently of the image modality (x-rays, neutrons, etc), image data analysis requires normalization, a preprocessing step. While the normalization can sometimes easily be generalized, the analysis is, in most cases, specific to an experiment and a sample. Although many tools (MATLAB, ImageJ, VG Studio…) offer a large collection of pre-programmed image analysis tools, they usually require a learning step that can be lengthy depending on the skills of the end user. We have implemented Jupyter Python notebooks to allow easy and straightforward data analysis, along with live interaction with the data. Jupyter notebooks require little programming knowledge and the steep learning curve is bypassed. Most importantly, each notebook can be tailored to a specific experiment and sample with minimized effort. Here, we present the pros and cons of the main methods to analyse data and show the reason why we have found that Jupyter Python notebooks are well suited for imaging data processing, visualization and analysis.

Bilheux, Jean-Christophe (ORCID:0000000321726487)↗

MedNAS: Multiscale Training-Free Neural Architecture Search for Medical Image Analysis

Deep neural networks have demonstrated impressive results in medical image analysis, but designing suitable architectures for each specific task is expertise dependent and time consuming. Neural architecture search (NAS) offers an effective means of discovering architectures. It has been highly successful in numerous applications, particularly in natural image classification. Yet, medical images possess unique characteristics, such as small regions and a wide variety of lesion sizes, that differentiate them from natural images. Furthermore, most current NAS methods struggle with high computational costs, especially when dealing with high-resolution image datasets. In this article, we present a novel evolutionary NAS method called multiscale training-free neural architecture search (MSTF-NAS) to address these challenges. Specifically, to accommodate the broad range of lesion region sizes in disease diagnosis, we develop a new reduction cell search space that enables the search algorithm to explicitly identify the optimal scale combination for multiscale feature extraction. Further, to overcome the issue of high computational costs, we utilize training-free indicators as performance measures for candidate architectures, which allows us to search for the optimal architecture more efficiently. More specifically, by considering the capability and simplicity of various networks, we formulate a multiobjective optimization problem that involves two training-free indicators and model complexity for candidate architectures. Extensive experiments on a large medical image benchmark and a publicly available breast cancer detection dataset are conducted. The empirical results demonstrate that our MSTF-NAS outperforms both human-designed architectures and current state-of-the-art NAS algorithms on both datasets, indicating the effectiveness of our proposed method.

60 APPLIED LIFE SCIENCES↗

Testing the LSST Difference Image Analysis Pipeline Using Synthetic Source Injection Analysis

Abstract We evaluate the performance of the Legacy Survey of Space and Time Science Pipelines Difference Image Analysis (DIA) on simulated images. By adding synthetic sources to galaxies on images, we trace the recovery of injected synthetic sources to evaluate the pipeline on images from the Dark Energy Science Collaboration Data Challenge 2. The pipeline performs well, with efficiency and flux accuracy consistent with the signal-to-noise ratio of the input images. We explore different spatial degrees of freedom for the Alard–Lupton polynomial-Gaussian image subtraction kernel and analyze for trade-offs in efficiency versus artifact rate. Increasing the kernel spatial degrees of freedom reduces the artifact rate without loss of efficiency. The flux measurements with different kernel spatial degrees of freedom are consistent. We also here provide a set of DIA flags that substantially filter out artifacts from the DIA source table. We explore the morphology and possible origins of the observed remaining subtraction artifacts and suggest that given the complexity of these artifact origins, a convolution kernel with a set of flexible bases with spatial variation may be needed to yield further improvements.

Liu, S. (ORCID:0000000244612143)↗

Characterization of gold nanoparticle films: Rutherford backscattering spectroscopy, scanning electron microscopy with image analysis, and atomic force microscopy

Gold nanoparticle films are of interest in several branches of science and technology, and accurate sample characterization is needed but technically demanding. We prepared such films by DC magnetron sputtering and recorded their mass thickness by Rutherford backscattering spectroscopy. The geometric thickness d{sub g}—from the substrate to the tops of the nanoparticles—was obtained by scanning electron microscopy (SEM) combined with image analysis as well as by atomic force microscopy (AFM). The various techniques yielded an internally consistent characterization of the films. In particular, very similar results for d{sub g} were obtained by SEM with image analysis and by AFM.

36 MATERIALS SCIENCE↗

Large-Scale Image Analysis for Investigating Spatio-Temporal Changes in Nuclear DNA Damage Caused by Nitrogen Atmospheric Pressure Plasma Jets

The effective clinical application of atmospheric pressure plasma jet (APPJ) treatments requires a well-founded methodology that can describe the interactions between the plasma jet and a treated sample and the temporal and spatial changes that result from the treatment. In this study, we developed a large-scale image analysis method to identify the cell-cycle stage and quantify damage to nuclear DNA in single cells. The method was then tested and used to examine spatio-temporal distributions of nuclear DNA damage in two cell lines from the same anatomic location, namely the oral cavity, after treatment with a nitrogen APPJ. One cell line was malignant, and the other, nonmalignant. The results showed that DNA damage in cancer cells was maximized at the plasma jet treatment region, where the APPJ directly contacted the sample, and declined radially outward. As incubation continued, DNA damage in cancer cells decreased slightly over the first 4 h before rapidly decreasing by approximately 60% at 8 h post-treatment. In nonmalignant cells, no damage was observed within 1 h after treatment, but damage was detected 2 h after treatment. Notably, the damage was 5-fold less than that detected in irradiated cancer cells. Moreover, examining damage with respect to the cell cycle showed that S phase cells were more susceptible to DNA damage than either G1 or G2 phase cells. The proposed methodology for large-scale image analysis is not limited to APPJ post-treatment applications and can be utilized to evaluate biological samples affected by any type of radiation, and, more so, the cell-cycle classification can be used on any cell type with any nuclear DNA staining.

cellular imaging↗

SU-F-T-302: Implementation of the RadCalc Image Analysis Tool for IMRT QA

Purpose: To assess RadCalc as a means for analyzing fluence maps of IMRT QA patient plans. Eclipse generated fluence maps were compared to RadCalc fluence maps generated from both Eclipse parameters and from dynalog trajectory files. Methods: Six IMRT plans consisting of fifty individual fields were compared both field-by-field and as composite plans. These plans were exported from Eclipse to RadCalc. Each plan was then delivered in QA mode on a Varian Clinac iX, while recording and saving the dynalog trajectory files. These files were then imported into RadCalc, providing three sources of generating fluence maps: Eclipse, RadCalc, and dynalog files. Using the image analysis tool in RadCalc, a gamma analysis was then performed as a point-by-point comparison for each IMRT field. The Eclipse fluence map was used as the baseline for each comparison. Results: Based on the manufacturer’s recommendations, all fields were normalized to the maximum pixel value within each Eclipse field. All data was analyzed using a gamma index of 3mm/3% with passing criteria of 90%. For both dynalog analysis and RadCalc fluence analysis, 48/50 created fluence maps passed at greater than 90% when compared with the Eclipse baseline. In analyzing the composite of each of the six patients’ plans, all plans passed over 90%. Conclusion: Using the dynalog trajectory files in combination with RadCalc Version 6.3 image analysis is a promising metric for verifying IMRT QA passing rates. Notably, if a field failed, it did so for both dynalog and RadCalc compared to Eclipse. This suggests RadCalc can accurately simulate fluence maps, with similar results to dynalog comparisons. Limitations within the RadCalc software were discovered in the analytical process such as pixel resolution and the inability to set minimum threshold values. Comparisons could be extended to include dose map and distance to agreement analysis by expanding software capabilities.

60 APPLIED LIFE SCIENCES↗

Catalyst-Vision (PEM Catalyst Layer Image Analysis Tool) [SWR-25-100]

Catalyst-Vision (PEM Catalyst Layer Image Analysis Tool) provides an advanced Python-based tool, primarily designed for use in a Jupyter/Colab notebook, for the quantitative morphological analysis of pre-segmented shapes. While developed for analyzing PEM catalyst layers from microscopy, its methodology is suitable for characterizing any grayscale object provided on a uniform white background. The tool uses a robust computer vision pipeline based on the Euclidean Distance Transform and skeletonization to accurately measure local thickness and tortuosity, providing a comprehensive characterization of an object's geometry and internal texture. If you find this code useful, please cite our preprint as: Chan, Ai-Lin and Hayden, Steven and Harvey, Steven P. and Smeaton, Michelle and Okrucky, Caleb and Watt, John and Ulična, Soňa and Spurgeon, Steven and Jungjohann, Katherine and Alia, Shaun, Mechanism-informed breakdown: understanding degradation by controlling voltage hold patterns in PEM water electrolyzers. Preprint (2025).

Spurgeon, Steven [National Laboratory of the Rocki↗

Automated Image Analysis Corrosion Working Group Update: February 1, 2018

These are slides for the automated image analysis corrosion working group update. The overall goals were: automate the detection and quantification of features in images (faster, more accurate), how to do this (obtain data, analyze data), focus on Laser Scanning Confocal Microscope (LCM) data (laser intensity, laser height/depth, optical RGB, optical plus laser RGB).

47 OTHER INSTRUMENTATION↗

Nuclear stockpile stewardship and Bayesian image analysis (DARHT and the BIE)

Since the end of nuclear testing, the reliability of our nation's nuclear weapon stockpile has been performed using sub-critical hydrodynamic testing. These tests involve some pretty 'extreme' radiography. We will be discussing the challenges and solutions to these problems provided by DARHT (the world's premiere hydrodynamic testing facility) and the BIE or Bayesian Inference Engine (a powerful radiography analysis software tool). We will discuss the application of Bayesian image analysis techniques to this important and difficult problem.

42 ENGINEERING↗

SU-F-J-177: A Novel Image Analysis Technique (center Pixel Method) to Quantify End-To-End Tests

Purpose: To implement a novel image analysis technique, “center pixel method”, to quantify end-to-end tests accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy was determined by delivering radiation to an end-to-end prototype phantom. The phantom was scanned with 0.8 mm slice thickness. The treatment isocenter was placed at the center of the phantom. In the treatment room, CBCT images of the phantom (kVp=77, mAs=1022, slice thickness 1 mm) were acquired to register to the reference CT images. 6D couch correction were applied based on the registration results. Electronic Portal Imaging Device (EPID)-based Winston Lutz (WL) tests were performed to quantify the errors of the targeting accuracy of the system at 15 combinations of gantry, collimator and couch positions. The images were analyzed using two different methods. a) The classic method. The deviation was calculated by measuring the radial distance between the center of the central BB and the full width at half maximum of the radiation field. b) The center pixel method. Since the imager projection offset from the treatment isocenter was known from the IsoCal calibration, the deviation was determined between the center of the BB and the central pixel of the imager panel. Results: Using the automatic registration method to localize the phantom and the classic method of measuring the deviation of the BB center, the mean and standard deviation of the radial distance was 0.44 ± 0.25, 0.47 ± 0.26, and 0.43 ± 0.13 mm for the jaw, MLC and cone defined field sizes respectively. When the center pixel method was used, the mean and standard deviation was 0.32 ± 0.18, 0.32 ± 0.17, and 0.32 ± 0.19 mm respectively. Conclusion: Our results demonstrated that the center pixel method accurately analyzes the WL images to evaluate the targeting accuracy of the radiosurgery system. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the American Cancer Society.

60 APPLIED LIFE SCIENCES↗

Data Mining – Image Analysis of Radiography for Zr Redistribution

The research effort described in this report represents a first attempt to investigate the radial redistribution of Zr in ternary fuel alloys U-xPu-10Zr (x = 0, 8, 19) irradiated in the in-reactor fuel experiments during the operation of the U.S. Department of Energy’s (DOE’s) Experimental Breeder Reactor II (EBR-II) at Idaho National Laboratory (INL) using methods of image processing on post-irradiation neutron radiographs. Approximately 130,000 metal fuel pins were irradiated in EBR-II during its 30 years of operation to develop and characterize existing and prospective fuels. For many of the metal fuel irradiation experiments, neutron radiography imaging was performed historically now allowing application of modern image analysis techniques to characterize fuel behavior, such as fuel swelling, fluff formation, and now, fuel alloy constituent redistribution. The redistribution of fuel components depends on the temperature field, radially, within the fuel. Specifically, Zr is expected to redistribute radially towards the center of the pin, as well as towards the outer zones. Currently, direct imaging of a pin cross-section through optical methods or scanning electron microscopy (SEM) is used to study the constituents’ redistribution, which is very time-consuming and can only be applied to a limited number of pins. An automated image processing technique allowing for the investigation of fuel radial redistribution zones would significantly accelerate data analysis. In general, if the fuel temperature is hot enough, three redistribution zones are expected, corresponding to the main fuel components (e.g., U, Pu, Zr). While more assessment will be performed in fiscal year (FY)-2023, it seems possible to differentiate the pins according to their fuel composition using image analysis techniques on neutron radiographs of metallic fuel pins based on the analysis to date.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integrating Flow Imaging Analysis and Single-Particle ICP-TOFMS for Comprehensive Micro- and Nanoplastic Characterization

Flow imaging analysis (FIA), provides composition-agnostic morphological characterization. These measurements of particle size and shape are valuable to mass-based analysis, such as single particle inductively coupled plasma time-of-flight mass spectrometry (sp-ICP-TOFMS), which provides quantitative data on elements within particles. Using these two methods together enables informed use of geometric assumptions required by sp-ICP-TOFMS, as particle mass is typically converted to a particle diameter using assumed-spherical geometry. To validate this concept, parallel measurements to determine particle diameters were performed by FIA and sp-ICP-TOFMS on four particle suspensions: 300 nm polystyrene Eu-doped nanoparticles, 1 μm Fe-rich beads, 3 μm four element calibration polystyrene beads and 5 μm polystyrene beads. The Fe-particles obtained the highest percent difference from the manufacturer’s nominal diameter, as the mean diameter obtained by FIA was overestimated by 21% and sp-ICP-TOFMS underestimated the mean diameter by 20.7%. Two types of particles were selected to test the effect of varying the particle number concentrations (PNC) on sizing accuracy, and both methods accurately sized each particle population at the PNC expected. Single particle analysis of carbon has continued to be a popular research topic, with direct applications to environmental pollutants in terms of nano- and micro- plastics. Real-world plastic particles were studied, and FIA’s measured circularity values demonstrated that the particles deviated from spherical geometries, therefore sp-ICP-TOFMS data should be interpreted as mass-based rather than size-based. Combining these techniques enables improved interpretation of particle populations and evaluation of particle sizes.

Szakas, Sarah [ORNL] (ORCID:0000000241332197)↗

Cross-correlation image analysis for real-time single particle tracking

Accurately measuring the translations of objects between images is essential in many fields, including biology, medicine, chemistry, and physics. One important application is tracking one or more particles by measuring their apparent displacements in a series of images. Popular methods, such as the center of mass, often require idealized scenarios to reach the shot noise limit of particle tracking and, therefore, are not generally applicable to multiple image types. More general methods, such as maximum likelihood estimation, reliably approach the shot noise limit, but are too computationally intense for use in real-time applications. These limitations are significant, as real-time, shot-noise-limited particle tracking is of paramount importance for feedback control systems. To fill this gap, we introduce a new cross-correlation-based algorithm that approaches shot-noise-limited displacement detection and a graphics processing unit-based implementation for real-time image analysis of a single particle.

Instruments & Instrumentation↗

Two worlds collide: Image analysis methods for quantifying structural variation in cluster molecular dynamics

Inspired by methods of remote sensing image analysis, we analyze structural variation in cluster molecular dynamics (MD) simulations through a unique application of the principal component analysis (PCA) and Pearson Correlation Coefficient (PCC). The PCA analysis characterizes the geometric shape of the cluster structure at each time step, yielding a detailed and quantitative measure of structural stability and variation at finite temperature. Our PCC analysis captures bond structure variation in MD, which can be used to both supplement the PCA analysis as well as compare bond patterns between different cluster sizes. Relying only on atomic position data, without requirement for a priori structural input, PCA and PCC can be used to analyze both classical and ab initio MD simulations for any cluster composition or electronic configuration. Taken together, these statistical tools represent powerful new techniques for quantitative structural characterization and isomer identification in cluster MD.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-performance data management for whole slide image analysis in digital pathology

When dealing with giga-pixel digital pathology in whole-slide imaging, a notable proportion of data records holds relevance during each analysis operation. For instance, when deploying an image analysis algorithm on whole-slide images (WSI), the computational bottleneck often lies in the input-output (I/O) system. This is particularly notable as patch-level processing introduces a considerable I/O load onto the computer system. However, this data management process could be further paralleled, given the typical independence of patch-level image processes across different patches. This paper details our endeavors in tackling this data access challenge by implementing the Adaptable IO System version 2 (ADIOS2). Our focus has been constructing and releasing a digital pathology-centric pipeline using ADIOS2, which facilitates streamlined data management across WSIs. Additionally, we’ve developed strategies aimed at curtailing data retrieval times. The performance evaluation encompasses two key scenarios: (1) a pure CPU-based image analysis scenario (“CPU scenario”), and (2) a GPU-based deep learning framework scenario (“GPU scenario”). Our findings reveal noteworthy outcomes. Under the CPU scenario, ADIOS2 showcases an impressive two-fold speed-up compared to the brute-force approach. In the GPU scenario, its performance stands on par with the cutting-edge GPU I/O acceleration framework, NVIDIA Magnum IO GPU Direct Storage (GDS). From what we know, this appears to be among the initial instances, if any, of utilizing ADIOS2 within the field of digital pathology. The source code has been made publicly available at https://github.com/hrlblab/adios.

Wang, Xiao↗

In situ liquid SEM imaging analysis revealing particle dispersity in aqueous solutions

A quantitative description on dispersity of boehmite (γ-AlOOH) particles, a key component for waste slurry at Hanford sites, can provide useful knowledge for understanding various physicochemical nature of the waste. In this work, in situ liquid scanning electron microscopy (SEM) was used to evaluate the dispersity of particles in aqueous conditions using a microfluidic sample holder, System for Analysis at Liquid Vacuum Interface (SALVI). Secondary electron (SE) images and image analyses were performed to determine particle centroid locations and the distance to the nearest neighbour particle centroid, providing reliable rescaled interparticle distances as a function of ionic strength in acidic and basic conditions. Our finding of the particle dispersity is consistent with physical insights from corresponding particle interactions under physicochemical conditions, demonstrating delicate changes in dispersity of boehmite particles based on novel in situ liquid SEM imaging and analysis.

47 OTHER INSTRUMENTATION↗