Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging calorimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Prototype Magnetic Calorimeter Arrays with Buried Wiring for the Lynx X-Ray Microcalorimeter

Metallic magnetic calorimeter (MMC) technology is a leading contender for detectors for the Lynx X-ray Microcalorimeter, which is an imaging spectrometer consisting of an array of greater than 100,000 pixels. The fabrication of such large arrays presents a challenge when attempting to route the superconducting wiring from the pixels to the multiplexed readout. If the wiring is designed to be planar, then an aggressive, submicron scale wiring pitch has to be employed, which is technically challenging to design and fabricate on account of the requirements of low inductance, low cross-talk, high critical currents and high yield. An alternative way to achieve large scale, high density wiring is through the use of multiple buried metal layers, planarized by Chemical Mechanical Planarization. This approach is well-suited for connecting thousands of pixels on a large focal plane to readout chips, and also for fabricating sensor meander coils with narrow line widths, which helps in increasing the sensor inductance and thus alleviates stray inductance issues associated with the wiring in large size arrays. In this work we describe the fabrication of high sensor inductance MMC arrays implementing Lynx concepts and incorporating multiple layers of buried Nb wiring. The detector array is composed of three sub-arrays with pixels optimized to meet the different science driven performance requirements of Lynx. In two of the sub-arrays we adopt a thermal multiplexing scheme to read out pixels by coupling 25 absorbers to a single sensor through thermal links of varied thermal conductance. We demonstrate the successful fabrication of multi-absorber MMCs with fine pitch pixels in very large size arrays.

Solid-State Physics↗

The comet rendezvous asteroid flyby mission

The Comet Rendezvous Asteroid Flyby Mission (CRAF) is described. After gravity assists from Venus and Earth, the spacecraft will fly by the asteroid 46 Hestia en route to a rendezvous with P/Tempel 2 in Nov. 1996, when the comet is near aphelion. The scientific experiments for the CRAF mission are: an imaging system; a visual and infrared mapping spectrometer; an infrared radiometer; a penetrator carrying a gamma-ray spectrometer, a scanning differential calorimeter and evolved gas analyzer, accelerometers, and temperature probes; a neutral gas and thermal ion mass spectrometer; a secondary ion mass spectrometer for analyzing dust, gas, and thermal ions; a scanning electron microscope and particle analyzer; an X-ray fluorescence and gas chromatographic analyzer for collected dust and ice samples; a dust counter and velocity analyzer; a retarding potential ion mass spectrometer; a supra-thermal ion mass spectrometer and electron analyzer; a magnetometer; and a coordinated radio, electron, and plasma wave analyzer.

Neugebauer, M.↗

First Peek of ASTRO-H Soft X-Ray Telescope (SXT) In-Orbit Performance

ASTRO-H (Hitomi) is a Japanese X-ray astrophysics satellite just launched in February, 2016, from Tanegashima, Japan by a JAXA's H-IIA launch vehicle. It has two Soft X-ray Telescopes (SXTs), among other instruments, that were developed by the NASA Goddard Space Flight Center in collaboration with ISAS/JAXA and Nagoya University. One is for an X-ray micro-calorimeter instrument (Soft X-ray Spectrometer, SXS) and the other for an X-ray CCD camera (Soft X-ray Imager, SXI), both covering the X-ray energy band up to 15 keV. The two SXTs were fully characterized at the 30-m X-ray beam line at ISAS/JAXA. The combined SXT+SXS system effective area is about 250 and 300 cm(exp 2) at 1 and 6 keV, respectively, although observations were performed with the gate valve at the dewar entrance closed, which blocks most of low energy X-rays and some of high energy ones. The angular resolution for SXS is 1.2 arcmin (Half Power Diameter, HPD). The combined SXT+SXI system effective area is about 370 and 350 cm (exp 2) at 1 and 6 keV, respectively. The angular resolution for SXI is 1.3 arcmin (HPD). The both SXTs have a field of view of about 16 arcmin (FWHM of their vignetting functions).The SXT+SXS field of view is limited to 3 x 3 arcmin by the SXS array size. In-flight data available to the SXT team was limited at the time of this conference and a point-like source data is not available for the SXT+SXS. Although due to lack of attitude information we were unable to reconstruct a point spread function of SXT+SXI, according to RXJ1856.5-3754 data, the SXT seems to be working as expected in terms of imaging capability. As for the overall effective area response for both SXT+SXS and SXT+SXI, consistent spectral model fitting parameters with the previous measurements were obtained for Crab and G21.5-0.9 data. On the other hand, their 2-10 keV fluxes differ by about 20% at this point. Calibration work is still under progress. The SXT is the latest version of the aluminum foil X-ray mirror, which is extremely light-weight and very low cost, yet produces large effective area over a wide energy-band. Its area-mass ratio is the largest, 16 cm(exp 2)/kg, among ASTRO-H, Chandra, and XMM-Newton mirrors. The aluminum foil mirror is a still compelling technology depending on the mission science goal.

X-rays↗

Analysis of SOFCAL calibration data

Ionization calorimeters determine the total energy of a particle by absorbing, within the mass of the calorimeter, the entire energy of the particle or a significant (and determinable) fraction of it. The JACEE group has used passive ionization calorimetery, which employs photographic emulsions as the detector medium, to measure the charge composition and energy spectrum of cosmic rays up to, and exceeding, 10(exp 14)eV. The SOFIC approach depends similarly on the use of three-dimensional nuclear-electromagnetic shower theory to relate the ionization deposits obtained during a shower to the energy of the particle causing the shower. Bundles of thousands of scintillating optical fibers are read out using image-intensified CCD's. Such an event may be triggered by a fast shower detector placed under the instrument or if only heavy particles are of interest, from a fast primary Cerention detector placed above the calorimeter. In the first study, fast Hammatsu photomultiplier tubes were purchased and tested for possible application for a triggering purpose. In the second study, some refinements have been made to the theoretical treatment of hadronic interactions in the central collision region. These will be helpful in improving the simulations necessary for observations of high energy cosmic ray nuclei with a SOFIC.

Gregory, John C.↗

Planetary exploration sensor systems

Most of the instruments that have been used in planetary exploration have been either spectrometers or imaging devices. Instruments of these types are being developed for the Galileo and VOIR (Venus Orbiting Imaging Radar) missions. Galileo will take advantage of new CCD (charge-coupled device) technology, and VOIR will use techniques of synthetic aperture radar developed for Seasat. For determining the macrostructure of mineral resources, the best approach is believed to involve acoustic imaging, essentially a seismic data processing technique. Determinations of microstructure would require a light microscope and an electron microscope. For determining the nature and form of volatiles, a differential scanning calorimeter could be used. To determine the mineral composition, an electron beam microprobe with X-ray fluorescence and spectroscopy would be used.

Saunders, R. S.↗

X-Ray Missions Based on LTD Technologies

Microcalorimeter arrays used as imaging spectrometers will enable ground-breaking science in X-ray astrophysics. Their development has been one of the driving applications of the low temperature detector community since the early 1980s. While their application in space remains in relative infancy, we are on the verge of an era in which microcalorimeter spectrometers are likely to dominate instrumentation for high-energy astrophysics missions. NASA sounding rocket experiments such as the X-ray Quantum Calorimeter (XQC) and Micro-X have now paved the way for orbital observatories. JAXA’s Astro-H gave us a glimpse of this fantastic new capability before its unfortunate demise. The launch of XRISM later this year should finally demonstrate the sort of large suite of observations that X-ray microcalorimeter arrays will make major contributions to. In the mid-2030s, we will see the launch of ESA’s flagship Athena mission, that will further advance the imaging and spectroscopic capabilities for the high-energy X-ray community enormously. Numerous other potential new mission concepts using X-ray microcalorimeters have been studied in detail such as NASA’s Lynx and the Light Element Mapper (LEM), JAXA’s Super-DIOS, and China’s Hot Universe Baryon Surveyor (HUBS). In the first half of this presentation, I will review the development and desired requirements of the X-ray microcalorimeter missions and concepts, and describe the current progress and status missions being implemented and proposed. In the second half of this presentation, I will focus on The Line Emission Mapper (LEM) which is a probe-class mission concept under study by NASA that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight X-ray optic with 10” angular resolution and a large-format microcalorimeter array with a 15” pixel pitch over a 29’ field of view (FOV). The main microcalorimeter array and readout design takes advantage of mature technology that has been developed for Athena X-IFU. The central 7’ region of the array consists of ~ 800 transition-edge sensors (TESs), optimized for a bandpass of 0.3-2 keV and with an energy resolution of 1.2 eV at 1 keV. The rest of the FOV is covered by 4-pixel TES hydras with 2.5 eV energy resolution at 1 keV. Hydras are position-sensitive (‘thermally multiplexed’) detectors that enable extremely large numbers of effective pixels in an array, without a commensurate increase in the number of wires, bias circuit, and readout components. In total the array will have ~ 4k TESs with ~ 14k imaging elements on a 290 micron-pitch. The array will be read out with state-of-the-art time-division multiplexing (TDM), implement with 59 pixels (and 1 dark pixel) in each of the 69 TDM columns. Here we present a detailed overview of the baseline microcalorimeter detector design and present first results from both single pixel TESs and 4-pixel hydras. Our prototype LEM pixels utilize 15um x 50um Mo/Au TESs with a transition temperature of around 58 mK. These pixels incorporate high-fill-factor Au absorbers of thickness 0.54um. We have demonstrated an energy resolution of 0.90+/-0.02 eV and 1.90 +/-0.02 eV at 1.5 keV for single pixel and 4-pixel hydras, respectively, meeting the performance requirements of LEM. We show how the position discrimination in the hydra pixels can be achieved, down to energies of a few 100 eV, using the measured pulse rise-times. Finally, we will show that the properties of the LEM pixels are well optimized for the proposed TDM read out architecture.

Simon Richard Bandler↗

Applications of Gas Imaging Micro-Well Detectors to an Advanced Compton Telescope

We present a concept for an Advanced Compton Telescope (ACT) based on the use of pixelized gas micro-well detectors to form a three-dimensional electron track imager. A micro-well detector consists of an array of individual micro-patterned proportional counters opposite a planar drift electrode. When combined with thin film transistor array readouts, large gas volumes may be imaged with very good spatial and energy resolution at reasonable cost. The third dimension is determined by timing the drift of the ionization electrons. The primary advantage of this approach is the excellent tracking of the Compton recoil electron that is possible in a gas volume. Such good electron tracking allows us to reduce the point spread function of a single incident photon dramatically, greatly improving the imaging capability and sensitivity. The polarization sensitivity, which relies on events with large Compton scattering angles, is particularly enhanced. We describe a possible ACT implementation of this technique, in which the gas tracking volume is surrounded by a CsI calorimeter, and present our plans to build and test a small prototype over the next three years.

Bloser, P. F.↗

The Orbiting Wide-Angle Light Collectors (OWL) Mission for Charged-Particle Astronomy

The space-based OWL mission is designed to perform high-statistics measurements of ultra-high-energy cosmic rays (UHECR) using the Earth's atmosphere as a vast particle calorimeter, furthering the field of charged-particle astronomy. OWL has been developed in formal NASA instrument and mission studies and is comprised of two large telescopes separated by approx.600 km in 1000 km, near-equatorial orbits to stereoscopically image the near-UV air fluorescence emitted by UHECR-induced particle cascades. The High Resolution Fly's Eye (HiRes) Collaboration, and subsequently the Pierre Auger Observatory, recently reported confirmation of the expected Greisen-Zatsepin-Kuzmin (GZK) suppression of the UHECR flux above a few times 10(exp 19) eV. This observation is consistent with the majority of UHECR originating in astrophysical objects and reduces the need to invoke exotic physical processes. Particles observed above the GZK threshold energy must have come from sources within about 100 Mpc from the Earth. The small particle deflection angles expected at UHECR energies, with standard assumptions of extragalactic magnetic fields, are on the order of 1 degree. Thus by observing particles above the GZK threshold with sufficient exposure, there is the potential of identifying and characterizing individual UHECR sources. Auger has reported significant anisotropy in the arrival directions of UHECR at energies above about 6 10(exp 19) eV observed in the South, and a correlation to AGN in the 12th VCV catalog, suggesting that the sources of UHECR are traced by the distribution of luminous matter in the Universe. However, with similar statistics and the same event selection criteria, HiRes observations in the North are consistent with isotropy. Extended observations by Auger-South, by Telescope Array in the North, and possibly by the proposed Auger-North, will further these investigations. However, much greater exposures will be required to fully identify individual sources and measure their cosmic ray spectra. A five-year OWL mission would deliver approximately 10(exp 6)sq km/sr/yr of exposure with full aperture reached at approx. 10(exp 19) eV. The baseline 3 m optical aperture OWL telescopes with 45 degree full field-of-view are easily accomodated on a single conventional launch vehicle. On orbit, the simultaneous viewing of the same volume of atmosphere allows for precise stereo event reconstruction, which is nearly independent of the inclination of the particle track and tolerant of atmospheric conditions. The availability of monocular operation provides increased reliability or can be employed to increase the instantaneous aperture. In stereo mode, OWL is also capable of fully reconstructing horizontal or upward-moving showers and so has unmatched sensitivity to neutrino-induced events. The details of the OWL mission will he presented and its science capabilities will be discussed.

Mitchell, John↗

EPE The Extreme Physics Explorer

The Extreme Physics Explorer (EPE) is a mission concept that will address fundamental and timely questions in astrophysics which are primary science objectives of IXO. The reach of EPE to the areas outlined in NASA RFI NNH11ZDA018L is shown as a table. The dark green indicates areas in which EPE can do the basic IXO science, and the light green areas where EPE can contribute but will not reach the full IXO capability. To address these science questions, EPE will trace orbits close to the event horizon of black holes, measure black hole spin in active galactic nuclei (AGN), use spectroscopy to characterize outflows and the environment of AGN, map bulk motions and turbulence in galaxy clusters, and observe the process of cosmic feedback where black holes inject energy on galactic and intergalactic scales. EPE gives up the high resolution imaging of IXO in return for lightweight, high TRL foil mirrors which will provide >20 times the effective area of ASTRO-H and similar spatial resolution, with a beam sufficient to study point sources and nearby galaxies and clusters. Advances in micro-calorimeters allow improved performance at high rates with twice the energy resolution of ASTRO-H. A lower TRL option would provide 200 times the area of ASTRO-H using a micro-channel plate optic (MCPO) and a deployable optical bench. Both options are in the middle range of RFI missions at between $600M and $1000M. The EPE foil optic has direct heritage to ASTRO-H, allowing robust cost estimates. The spacecraft is entirely off the shelf and introduces no difficult requirements. The mission could be started and launched in this decade to an L2 orbit, with a three-year lifetime and consumables for 5 years. While ASTRO-H will give us the first taste of high-resolution, non-dispersive X-ray spectroscopy, it will be limited to small numbers of objects in many categories. EPE will give us the first statistically significant samples in each of these categories.

Garcia, Michael↗

Simple, Compact, High-Resolution Monochromatic X-Ray Source for Characterization of X-Ray Calorimeter Arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

M A Leutenegger↗

Design and Performance of the Hitomi/XRISM Adiabatic Demagnetization Refrigerator Controller

The Resolve instrument in the recently launched X-ray Imaging and Spectroscopy Mission (XRISM) is a rebuild of the Soft X-ray Spectrometer (SXS) in Hitomi (aka Astro-H which had an unfortunately brief mission life in 2016). It is a high-resolution non-dispersive soft x-ray spectrometer from nominally 0.3 keV to 12 keV based on a calorimeter detector array operating at 50 mK with a resolution better than 7 eV FWHM at 6 keV. For such sensitive cryogenic instruments, temperature stability has a strong impact on the detector’s performance. The Adiabatic Demagnetization Refrigerator Controller (ADRC) in the XRISM Resolve instrument is an electronics box responsible for high-precision sub-K temperature readout and control of the multi-stage adiabatic demagnetization refrigerator subsystem to achieve a thermal stability better than 2.5 uK RMS (over a 10-minute interval) for the calorimeter detectors in both cryogen (liquid helium) and cryo-free modes. It has direct telemetry/command and power interfaces with the spacecraft. It also provides sensor read-out and heater circuits for decontamination of the filters in the cold aperture. As a part of the discussion on the design and performance of the ADRC, this paper will also include an overall view of the 50 mK temperature control, plus monitor and control of the aperture filter temperature for de-contamination purpose.

ADRC↗

Design and Performance of the Hitomi/XRISM Adiabatic Demagnetization Refrigerator Controller

The Resolve instrument in the recently launched X-ray Imaging and Spectroscopy Mission (XRISM) is a rebuild of the Soft X-ray Spectrometer (SXS) in Hitomi (aka Astro-H which had an unfortunately brief mission life in 2016). It is a high-resolution non-dispersive soft x-ray spectrometer from nominally 0.3 keV to 12 keV based on a calorimeter detector array operating at 50 mK with a resolution better than 7 eV FWHM at 6 keV. For such sensitive cryogenic instruments, temperature stability has a strong impact on the detector’s performance. The Adiabatic Demagnetization Refrigerator Controller (ADRC) in the XRISM Resolve instrument is an electronics box responsible for high-precision sub-K temperature readout and control of the multi-stage adiabatic demagnetization refrigerator subsystem to achieve a thermal stability better than 2.5 uK RMS (over a 10-minute interval) for the calorimeter detectors in both cryogen (liquid helium) and cryo-free modes. It has direct telemetry/command and power interfaces with the spacecraft. It also provides sensor read-out and heater circuits for decontamination of the filters in the cold aperture. As a part of the discussion on the design and performance of the ADRC, this paper will also include an overall view of the 50 mK temperature control, plus monitor and control of the aperture filter temperature for de-contamination purpose.

ADRC↗

TES-Based X-Ray Microcalorimeter Performances Under AC Bias and FDM for Athena

Athena is a European X-ray observatory, scheduled for launch in 2028. Athena will employ a high-resolution imaging spectrometer called X-ray integral field unit (X-IFU), consisting of an array of 4000 transition edge sensor (TES) microcalorimeter pixels. For the readout of X-IFU, we are developing frequency domain multiplexing, which is the baseline readout system. In this paper, we report on the performance of a TES X-ray calorimeter array fabricated at Goddard Space Flight Center (GSFC) at MHz frequencies for the baseline of X-IFU detector. During single-pixel AC bias characterization, we measured X-ray energy resolutions (at 6 keV) of about 2.9 eV at both 2.3 and 3.7 MHz. Furthermore, in the multiplexing mode, we measured X-ray energy resolutions of about 2.9 eV at 1.3 and 1.7 MHz.

Transition edge sensors X-ray microcalorimeter Fre↗

AXSIO and the NASA X-ray Mission Concept Study

The Advanced X-ray Spectroscopy and Imaging Observatory (AXSIO) focuses on the IXO science objectives ranked highly by the Decadal Survey: tracing orbits near 5MBH event horizons, measuring BH spin, characterizing outflows and the environment of AGN, observing 5MBH to z=6, mapping gas motion in clusters, finding the missing baryons, and observing cosmic feedback. AXSIO's streamlining of IXO includes reduction in the instrument complement to a calorimeter and a grating spectrometer, and relaxation of the angular resolution to 10". With 0.9 m2 effective area at 1.25 keV, AXSIO delivers a 30-fold performance increase over current missions for high-resolution spectroscopy and spectroscopic timing. NASA has also undertaken a study of notional missions to determine lower cost approaches to accomplishing IXO objectives over the next decade. Three concepts were studied; which as a group encompass the full range of IXO science. The capabilities and architecture of these missions are summarized.

Petre, Robert↗

NASA Tech Briefs, July 2011

Topics covered include: 1) Collaborative Clustering for Sensor Networks; 2) Teleoperated Marsupial Mobile Sensor Platform Pair for Telepresence Insertion Into Challenging Structures; 3) Automated Verification of Spatial Resolution in Remotely Sensed Imagery; 4) Electrical Connector Mechanical Seating Sensor; 5) In Situ Aerosol Detector; 6) Multi-Parameter Aerosol Scattering Sensor; 7) MOSFET Switching Circuit Protects Shape Memory Alloy Actuators; 8) Optimized FPGA Implementation of Multi-Rate FIR Filters Through Thread Decomposition; 9) Circuit for Communication Over Power Lines; 10) High-Efficiency Ka-Band Waveguide Two-Way Asymmetric Power Combiner; 11) 10-100 Gbps Offload NIC for WAN, NLR, and Grid Computing; 12) Pulsed Laser System to Simulate Effects of Cosmic Rays in Semiconductor Devices; 13) Flight Planning in the Cloud; 14) MPS Editor; 15) Object-Oriented Multi Disciplinary Design, Analysis, and Optimization Tool; 16) Cryogenic-Compatible Winchester Connector Mount and Retaining System for Composite Tubes; 17) Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy; 18) Planar Rotary Piezoelectric Motor Using Ultrasonic Horns; 19) Self-Rupturing Hermetic Valve; 20) Explosive Bolt Dual-Initiated from One Side; 21) Dampers for Stationary Labyrinth Seals; 22) Two-Arm Flexible Thermal Strap; 23) Carbon Dioxide Removal via Passive Thermal Approaches; 24) Polymer Electrolyte-Based Ambient Temperature Oxygen Microsensors for Environmental Monitoring; 25) Pressure Shell Approach to Integrated Environmental Protection; 26) Image Quality Indicator for Infrared Inspections; 27) Micro-Slit Collimators for X-Ray/Gamma-Ray Imaging; 28) Scatterometer-Calibrated Stability Verification Method; 29) Test Port for Fiber-Optic-Coupled Laser Altimeter; 30) Phase Retrieval System for Assessing Diamond Turning and Optical Surface Defects; 31) Laser Oscillator Incorporating a Wedged Polarization Rotator and a Porro Prism as Cavity Mirror; 32) Generic, Extensible, Configurable Push-Pull Framework for Large-Scale Science Missions; 33) Dynamic Loads Generation for Multi-Point Vibration Excitation Problems; 34) Optimal Control via Self-Generated Stochasticity; 35) Space-Time Localization of Plasma Turbulence Using Multiple Spacecraft Radio Links; 36) Surface Contact Model for Comets and Asteroids; 37) Dust Mitigation Vehicle; 38) Optical Coating Performance for Heat Reflectors of the JWST-ISIM Electronic Component; 39) SpaceCube Demonstration Platform; 40) Aperture Mask for Unambiguous Parity Determination in Long Wavelength Imagers; 41) Spaceflight Ka-Band High-Rate Radiation-Hard Modulator; 42) Enabling Disabled Persons to Gain Access to Digital Media; 43) Cytometer on a Chip; 44) Principles, Techniques, and Applications of Tissue Microfluidics; and 45) Two-Stage Winch for Kites and Tethered Balloons or Blimps.

Source record↗

An Overview of High-Resolution, Non-Dispersive, Imaging Spectrometers for High-Energy Photons

High-resolution x-ray spectroscopy has become a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites initiated a new era in x-ray astronomy. Despite their successes, there is still need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band and for extended sources. What is needed is a non-dispersive imaging spectrometer - essentially a 14-bit x-ray color camera. And a requirement for a nondispersive spectrometer designed to provide eV-scale spectral resolution is a temperature below 0.1 K. The required spectral resolution and the constraints of thermodynamics and engineering dictate the temperature regime nearly independently of the details of the sensor or the read-out technology. Low-temperature spectrometers can be divided into two classes - - equilibrium and non-equilibrium. In the equilibrium devices, or calorimeters, the energy is deposited in an isolated thermal mass and the resulting increase in temperature is measured. In the non-equilibrium devices, the absorbed energy produces quantized excitations that are counted to determine the energy. The two approaches have different strong points, and within each class a variety of optimizations have been pursued. I will present the basic fundamentals of operation and the details of the most successful device designs to date. I will also discuss how the measurement priorities (resolution, energy band, count rate) influence the optimal choice of detector technology.

Kilbourne, Caroline↗

Development of X-Ray Microcalorimeter Imaging Spectrometers for the X-Ray Surveyor Mission Concept

Four astrophysics missions are currently being studied by NASA as candidate large missions to be chosen inthe 2020 astrophysics decadal survey.1 One of these missions is the X-Ray Surveyor (XRS), and possibleconfigurations of this mission are currently under study by a science and technology definition team (STDT). Oneof the key instruments under study is an X-ray microcalorimeter, and the requirements for such an instrument arecurrently under discussion. In this paper we review some different detector options that exist for this instrument,and discuss what array formats might be possible. We have developed one design option that utilizes eithertransition-edge sensor (TES) or magnetically coupled calorimeters (MCC) in pixel array-sizes approaching 100kilo-pixels. To reduce the number of sensors read out to a plausible scale, we have assumed detector geometriesin which a thermal sensor such a TES or MCC can read out a sub-array of 20-25 individual 1 pixels. In thispaper we describe the development status of these detectors, and also discuss the different options that exist forreading out the very large number of pixels.

multiplexing↗

Optimization of X-ray Absorbers for TES Microcalorimeters

We have investigated the thermal, electrical, and structural properties of Bi and BiCu films that are being developed as X-ray absorbers for transition-edge sensor (TES) microcalorimeter arrays for imaging X-ray spectroscopy. Bi could be an ideal material for an X-ray absorber due to its high X-ray stopping power and low heat capacity, but it has a low thermal conductivity, which can result in position dependence of the pulses in the absorber. In order to improve the thermal conductivity, we added Cu layers in between the Bi layers. We measured electrical and thermal conductivities of the films around 0.1 K(sub 1) the operating temperature of the TES calorimeter, to examine the films and to determine the optimal thickness of the Cu layer. From the electrical conductivity measurements, we found that the Cu is more resistive on the Bi than on a Si substrate. Together with an SEM picture of the Bi surface, we concluded that the rough surface of the Bi film makes the Cu layer resistive when the Cu layer is not thick enough t o fill in the roughness. From the thermal conductivity measurements, we determined the thermal diffusion constant to be 2 x l0(exp 3) micrometers squared per microsecond in a film that consists of 2.25 micrometers of Bi and 0.1 micrometers of Cu. We measured the position dependence in the film and found that its thermal diffusion constant is too low to get good energy resolution, because of the resistive Cu layer and/or possibly a very high heat capacity of our Bi films. We show plans to improve the thermal diffusion constant in our BiCu absorbers.

Iyomoto, Naoko↗