Search NASASearch

SEARCH · Search NASA

Results for “Imaging techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

397 records · Page 3

Multi-contrast machine learning improves schistosomiasis diagnostic performance

Schistosomiasis currently affects over 250 million people and remains a public health burden despite ongoing global control efforts. Conventional microscopy is a practical tool for diagnosis and screening ofSchistosoma haematobium, but identification of eggs requires a skilled microscopist. Here we present a machine learning (ML)-based strategy for automated detection ofS. haematobiumthat combines two imaging contrasts, brightfield (BF) and darkfield (DF), to improve diagnostic performance. We collected BF and DF images of urine samples, many of them containingS. haematobiumeggs, during two different field studies in Côte d’Ivoire using a mobile phone-based microscope, the SchistoScope. We then trained separate egg-detection ML models and compared the patient-level performance of BF and DF models alone to combinations of BF and DF models, using annotations from trained microscopists as the gold standard. We found that models trained on DF images, and almost all BF and DF combinations, performed significantly better than models trained on BF images only. When models were trained on images from the first field study (n = 349 patients, 748 images of each contrast), patient-level classification performance on patient images from the second study (n = 375 patients, 752 images of each contrast) met the WHO Diagnostic Target Product Profile (TPP) sensitivity and specificity for the monitoring and evaluation use case (sensitivity for all models and combinations was >75% when evaluated at a confidence score threshold that resulted in specificity >96.5%). When we used images from both field studies for the training set, performance of the models was improved. Overall, this work shows that the use of DF and BF increases the performance of ML models on images from devices with low-cost optics, while retaining the portability, power, and time-to-results of the WHO’s diagnostic TPP. DF requires no additional sample preparation and does not increase the complexity of the imaging system. It thus offers a practical means to improve performance of automated diagnostics forS. haematobiumas well as other microscopy-based diagnostics.

Infectious Diseases

Nanoscopic Imaging of Self-Propelled Ultrasmall Catalytic Nanomotors

Ultrasmall nanomotors (<100 nm) are highly desirable nanomachines for their size-specific advantages over their larger counterparts in applications spanning nanomedicine, directed assembly, active sensing, and environmental remediation. While there are extensive studies on motors larger than 100 nm, the design and understanding of ultrasmall nanomotors have been scant due to the lack of high-resolution imaging of their propelled motions with orientation and shape details resolved. Here, we report the imaging of the propelled motions of catalytically powered ultrasmall nanomotors─hundreds of them─at the nanometer resolution using liquid-phase transmission electron microscopy. These nanomotors are Pt nanoparticles of asymmetric shapes (“tadpoles” and “boomerangs”), which are colloidally synthesized and observed to be fueled by the catalyzed decomposition of NaBH4 in solution. Statistical analysis of the orientation and position trajectories of fueled and unfueled motors, coupled with finite element simulation, reveals that the shape asymmetry alone is sufficient to induce local chemical concentration gradient and self-diffusiophoresis to act against random Brownian motion. Our work elucidates the colloidal design and fundamental forces involved in the motions of ultrasmall nanomotors, which hold promise as active nanomachines to perform tasks in confined environments such as drug delivery and chemical sensing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

The Evolution in Coma Molecular Composition of Comet C/2017 K2 (PanSTARRS) Across the H 2 O Sublimation Zone: ALMA Imaging of an H 2 O-Dominated Coma

We report a survey of molecular emission from cometary volatiles using the Atacama Large Millimeter/Submillimeter Array (ALMA) toward comet C/2017 K2 (PanSTARRS) carried out on UT 2022 September 21, 22, and 23 at a heliocentric distance r H 3 OH, and H 2 CO (along with continuum emission from dust) sampled molecular chemistry in C/2017 K2 at the inner edge of the H 2 O sublimation zone, the region from r H 2 O begins vigorously subliming and increasingly dominating comet activity, discerning parent from daughter or extended source species. This work presents spectrally integrated flux maps, production rates, and parent scale lengths for each molecule. CH 3 OH, CO, and HCN were produced within ~250 km of the nucleus, potentially including contributions from sublimation of icy grains. CS was consistent with production from CS 2 photolysis, and H 2 CO required production from extended sources in the coma. An ortho-to-para ratio of 2.9 ± 0.4 for H 2 CO was derived from simultaneously measured transitions of each spin species. The continuum was extended and spatially resolved, consistent with thermal emission from dust in the coma. Analysis of the continuum visibilities provided an upper limit on the nucleus diameter d <6.6 km and coma dust masses of (1.2-2.4) times10 11 kg.

Nathan X Roth

ClassNMSW- a real-time classification approach for non-recycled municipal solid waste using hyperspectral imaging

Real-time classification of non-recycled municipal solid waste (NMSW) is essential for efficient valorization. This study introduces ClassNMSW, a comprehensive framework for classifying 22 NMSW subclasses under industrial constraints by using hyperspectral imaging (HSI). A primary innovation of this work is the development of a variance-controlled spectral extraction algorithm. Unlike traditional methods that rely on simple averaging, this approach systematically investigates the extent of pixel extraction to minimize the loss of critical chemical information while maximizing data reduction thus ensuring high spectral fidelity with low computational cost. The approach developed in this work integrates automated, computer-vision-based background removal, eliminating the need for the manual thresholding common in current literature. To resolve ambiguities among chemically similar subclasses, a tiered classification and multi-camera fusion strategy (NIR17 and NIR22) is implemented. Results demonstrate that ClassNMSW achieves an object-wise weighted accuracy of 98.70% for single-sensor configurations and 100% under sensor fusion. A novel rolling-window strategy satisfies desired end-to-end latency of <2 s, satisfying the strict deterministic requirements of high-speed industrial sorting environments. The ClassNMSW framework provides a scalable foundation for advancing circularity and resource recovery in large-scale waste valorization operations.

99 - GENERAL AND MISCELLANEOUS

Collision Tracking in OpenMC: Methods and Applications in Neutron Noise, Neutron Imaging, Time-of-Flight, and Multiplicity Counting

We present the development and application of a collision tracking feature within the OpenMC Monte Carlo particle transport code, designed for diverse applications such as neutron spectroscopy, scatter camera system, neutron noise, and multiplicity counting simulations. This feature enables the tracking of individual particle collisions, with potential applications in nuclear nonproliferation, reactor physics, and nuclear security. Additionally, the feature holds potential for the calibration of neutron detectors, specifically in converting light output into energy deposited within the detectors. The implementation consists of a set of filters—such as reaction type, energy, cell, and material—that constrain the set of collisions that are tracked, extensions to the Python API to enable simple input specification, and support for writing either OpenMC’s native HDF5-based format or the Monte Carlo particle list format. This feature was added to the official OpenMC release in version 0.15.3. In this work, the feature will be applied to showcase scenarios such as time-of-flight simulations, scatter-camera imaging for neutron source localization, neutron-noise analysis to extract integral kinetic parameters such as the prompt decay constant α, and multiplicity counting to estimate the mass of special nuclear materials. Ultimately, this feature aims to expand the application scope of open-source Monte Carlo particle transport codes such as OpenMC.

Monte Carlo code

Boron-Based Neutron Scintillator Screen Characterization with X-Rays and Neutrons

Recent work on boron-based neutron scintillator screens suggests these screens can offer superior performance when compared to commonly used screens. Borated neutron scintillator screens perform well in terms of light output (5-6 times greater than a standard Gadox screen) and detection effi-ciency (larger than standard LiF+ZnS screens). However, previously manu-factured boron-based screens have exhibited non-uniform surface coating and a poor mixture between phosphor and converter particles. The objective of this work was to evaluate newly fabricated scintillator screens to deter-mine if enhanced fabrication methods produced a more homogeneous distribution between neutron converter and scintillation phosphor particles. Uniformity of scintillator material deposition was also inspected. This new iteration of screens appeared more uniform than previous generations with the new coating method improving surface chemistry and scintillator material homogeneity. Additionally, a new methodology for screen characterization, involving the correlation of a neutron image taken with a borated scintillator screen to X-ray computed tomography of that same screen, was demonstrated to elucidate a relationship between scintillator screen thickness and relative light output of the screen under neutron exposure. This method suggested that the ideal thickness of scintillator material was ~150 µm to maximize light output of the screen.

36 - MATERIALS SCIENCE

TRTR NRAD NRS Beamline Abstract

The Neutron Radiography (NRAD) Reactor is a 250kW TRIGA housed under the largest hot cell in the United States, making it the foremost location to perform neutron imaging of irradiated nuclear fuels and materials, including those intended for use with advanced reactors. Currently, NRAD has two radial beamlines that are used for neutron radiography and tomography. Upgrades to the North neutron beamline include the replacement of the in-tank beam chamber, through-the-wall collimator, and neutron shutter. These beamline upgrades will not only improve image quality for current capabilities but will also condition the beam to be more suitable for advanced methods such as neutron powder diffraction. These upgrades will increase the excess reactivity of the core, reduce unnecessary activation and exposure to workers, and significantly reduce the amount of shielding required around the beam. This presentation will describe how these upgrades improve beam quality, increase utilization of the reactor, and reduce radiation exposure to personnel.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN

The Study of Dopant Segregation Behavior During the Growth of GaAs in Microgravity

An investigation into the segregation behavior of selenium doped gallium arsenide during directional solidification in the microgravity environment was conducted using the Crystal Growth Furnace (CGF) aboard the first United States Microgravity Laboratory (USML-1). The two crystals grown were 1.5 cm in diameter and 16.5 cm in length with an initial melt length of 14 cm. Two translation periods were executed, the first at 2.5 microns/s and after a specified time, which was different between the two experiments, the translation rate was doubled to 5.0 microns/s. The translation was then stopped and the remaining sample melt was solidified using a gradient freeze technique in the first sample and a rapid solidification in the second experiment. Measurement of the selenium dopant distribution, using quantitative infrared transmission imaging, indicates that the first sample initially achieved diffusion controlled growth as desired. However, after about 1 cm of growth, the segregation behavior was driven from a diffusion controlled growth regime to a complete mixing regime. Measurements in the second flight sample indicated that the growth was always in a complete mixing regime. In both experiments, voids in the center line of the crystal, indicative of bubble entrapment, were found to correlate with the position in the crystal when the translation rates were doubled.

D H Matthiesen

Long-Term Evaluation of Landsat 9 Oli Data Product Uniformity at Focal Plane Module-Boundaries Using Earth Scenes

The uniformity performance characteristic in remote sensing data products is a metric that helps evaluate how an image accurately represents radiometric responses to geophysical variability at the Earth’s surface or within the atmosphere. These uniformity attributes are used in Earth remote sensing science applications such as investigating water quality, land-cover/land-use classifications, and crop health assessments. To ensure these applications perform effectively, it is crucial to maintain and regularly assess the uniformity of calibrated remote sensing data products. In the Landsat missions, data from the onboard radiometric reference Solar diffuser device are used as the standard approach to derive the calibration parameters, ensuring the maintenance of both absolute radiance and radiometric uniformity through quarterly updates. This publication presents an alternative approach that leverages Earth scene data to assess the on-orbit uniformity performance of the Landsat 9 (L9) mission. The analysis characterizes uniformity at a specific set of spatial positions (the focal-plane boundary zones) that are intrinsic to the Operational Land Imager (OLI) focal plane design. By employing these Earth data statistics, the article further explores the temporal trends in the radiometric uniformity results. The results shown in this article demonstrate that for pushbroom imaging design systems with staggered sensor chip focal plane architectures, the co-registered pixels, i.e., overlapping measurements of the same ground target viewed by different detectors, offer a self-contained mechanism for assessing product uniformity. Remarkably, this alternative approach achieves a level of radiometric quality comparable to that delivered by a stable, well-characterized onboard Solar diffuser calibration device. The findings demonstrate the potential and capability of such Earth scene statistics in maintaining radiometric uniformity in calibrated data products to better than 1% (1-sigma) throughout the mission’s operational lifetime.

trend

Chapter 19A – Radar Cross Section

The material in this Section will provide the novice Flight Test Engineer (FTE) with a brief overview of the radar cross section (RCS) concept. Brief details of radar range descriptions, operations, target calibrations, and data reduction are included. It is noted that these range operations concentrate on the "static" test range rather than the much more sophisticated "dynamic" test range. The dynamic test range is what the FTE will probably work with. Radar reflectivity measurement has developed over the last two decades from a relatively simple endeavor involving the measurement of target RCS amplitude statistics to involving wide band, coherent systems that can measure high resolution images of targets as well as, in many cases, the polarization and phasing properties. This rapid growth in RCS technology has occurred because of the increased use of radar in today's commercial and military systems. In general, the goal for commercial systems is to enhance radar reflectivity, whereas the military goal is to reduce radar reflectivity. Also, classification and identification are important for military purposes because in adverse weather radar may be the only system that may be capable of separating enemy targets from friendly ones. This Section will discuss the fundamentals of RCS. Since the flight test techniques associated with RCS measurements are very similar to those of antenna pattern measurements, both will be presented at the same time in Section 19B Antenna Radiation Pattern Measurements.

Robert W Borek

The Impact of Bias Row Noise to Photometric Accuracy: Case Study Based on a Scientific CMOS Detector

Abstract We tested a new model of CMOS detector manufactured by the Gpixel Inc, for potential space astronomical application. In laboratory, we obtain some bias images under the typical application environment. In these bias images, clear random row noise pattern is observed. The row noise also contains some characteristic spatial frequencies. We quantitatively estimated the impact of this feature to photometric measurements, by making simulated images. We compared different bias noise types under strict parameter control. The result shows the row noise will significantly deteriorate the photometric accuracy. It effectively increases the readout noise by a factor of 2–10. However, if it is properly removed, the image quality and photometric accuracy will be significantly improved.

Astronomy & Astrophysics

Surface science insight note: Optimizing XPS instrument performance for quantification of spectra

X-ray photoelectron spectroscopy (XPS) provides quantitative information from photoemission peaks and shapes observed within the background due to the inelastic scattering of photoelectrons. To quantify the signal, both photoemission peaks and background in spectra must be adjusted for instrumental transmission variations that are a consequence of changes in efficiency when recording electrons with different kinetic energy. While it is generally assumed that correcting spectroscopic data for transmission is a necessary part of quantification by XPS, there are consequences for the quantification of spectra measured using an instrument for which transmission has significant curvature. In this Insight, the implications of curvature in transmission characteristics are discussed and a method based on XPS microscopy is proposed that ensures the transmission response of an instrument is free from significant curvature. An example of an instrument for which a flat transmission response is presented is achieved through collecting spectra using lens modes designed to measure stigmatic images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Connectivity, Pathology, and ApoE4 Interactions Predict Longitudinal Tau Spatial Progression and Memory

ABSTRACT Tau pathology spread into neocortex indicates a transition from healthy aging to Alzheimer's disease (AD). Connectivity between tau epicenters and later accumulating regions of cortex has been proposed as a mechanism of tau spread, but how this relationship changes with greater AD pathology burden or genotype is not understood. We investigated tau accumulation in two key regions, precuneus and inferior temporal cortex, using resting state functional connectivity (rsFC) and longitudinal PET imaging from a multicohort sample of cognitively unimpaired older adults. We examined how baseline tau PET, Aβ PET, and ApoE4 genotype status interact with rsFC between hippocampus and these downstream regions to predict rate of tau accumulation in neocortex. We found that the 3‐way interaction between connectivity, baseline tau, and baseline Aβ or ApoE4 status was associated with neocortical tau accumulation in precuneus and inferior temporal cortex. In addition, baseline tau, Aβ, and ApoE4 status also moderated the association between connectivity and rate of memory decline. Together, these results suggest that the extent and distribution of future tau accumulation may be predicted by the interaction of baseline connectivity, AD pathology, and genetic risk.

Neurosciences & Neurology

Synthesis‐Related Nanoscale Defects in Mo‐Based Janus Monolayers Revealed by Cross‐Correlated AFM and TERS Imaging

2D Janus transition metal dichalcogenides (TMDs) are promising candidates for various applications including non-linear optics, energy harvesting, and catalysis. These materials are usually synthesized via chemical conversion of pristine TMDs. Nanometer-scale characterization of the obtained Janus materials’ morphology and local composition is crucial for both the synthesis optimization and the future device applications. In this work, we present the results of cross-correlated atomic force microscopy (AFM) and tip-enhanced Raman spectroscopy (TERS) study of Janus monolayers synthesized by the hydrogen plasma-assisted chemical conversion of MoSe 2 and MoS 2 . We demonstrate that the choice of both the growth substrate and the starting TMD influences the residual strain, thereby shaping the nanoscale morphology of the resulting Janus material. Furthermore, by employing TERS imaging, we show the presence of nanoscale islands (≈20 nm across) of MoSe 2 - ${\mathrm{Mo}}_{{\mathrm{Se}}}^{\mathrm{S}}$ (MoS 2 -${\mathrm{Mo}}_{\mathrm{S}}^{{\mathrm{Se}}}$) vertical heterostructures originating from the bilayer nanoislands in the precursor monolayer crystals. The understanding of the origins of nanoscale defects in Janus TMDs revealed in this study can help with further optimization of the Janus conversion process towards uniform and wrinkle-/crack-free Janus materials. Moreover, this work shows that cross-correlated AFM and TERS imaging is a powerful and accessible method for studying nanoscale composition and defects in Janus TMD monolayers.

2D materials

An Automated Probabilistic Asteroid Prediscovery Pipeline

We present an automated and probabilistic method to make prediscovery detections of near-Earth asteroids (NEAs) in archival survey images, with the goal of reducing orbital uncertainty immediately after discovery. We refit the Minor Planet Center's astrometry and propagate the full six-parameter covariance to survey epochs to define search regions. We build low-threshold source catalogs for viable images and evaluate every detected source in a search region as a candidate prediscovery. We eliminate false positives by refitting a new orbit to each candidate and probabilistically linking detections across images using a likelihood ratio. Applied to the Zwicky Transient Facility's (ZTF) imaging, we identify approximately 3000 recently discovered NEAs with prediscovery potential, including a doubling of the observational arc for about 500. We use archival ZTF imaging to make prediscovery detections of the potentially hazardous asteroid 2021 DG1, extending its arc by 2.5 yr and reducing future apparition sky plane uncertainty from many degrees to arcseconds. We also recover 2025 FU24 nearly 7 yr before its first known observation, when its sky plane uncertainty covers hundreds of square degrees across thousands of ZTF images. The method is survey agnostic and scalable, enabling rapid orbit refinement for new discoveries from Rubin, NEO Surveyor, and NEOMIR.

79 ASTRONOMY AND ASTROPHYSICS

O Corona, where art thou? eROSITA’s view of UV-optical-IR variability-selected massive black holes in low-mass galaxies

Finding massive black holes (MBHs,M BH ≈ 10 4 –10 7 M ⊙ ) in the nuclei of low-mass galaxies $\left( {{M_*}\mathop {\mathop < \limits_ }\limits_ {{10}^{10}}{M_ \odot }} \right)$ is crucial to constrain seeding and growth of black holes over cosmic time, but it is particularly challenging due to their low accretion luminosities. Variability selection via long-term photometric ultraviolet, optical, or infrared (UVOIR) light curves has proved effective and identifies lower-Eddington ratios compared to broad and narrow optical spectral lines searches. In the inefficient accretion regime, X-ray and radio searches are effective, but they have been limited to small samples. Therefore, differences between selection techniques have remained uncertain. Here, we present the first large systematic investigation of the X-ray properties of a sample of known MBH candidates in dwarf galaxies. We extracted X-ray photometry and spectra of a sample of ~200 UVOIR variability-selected MBHs and significantly detected 17 of them in the deepest available SRG/eROSITA image, of which four are newly discovered X-ray sources and two are new secure MBHs. This implies that tens to hundreds of LSST MBHs will have SRG/eROSITA counterparts, depending on the seeding model adopted. Surprisingly, the stacked X-ray images of the many non-detected MBHs are incompatible with standard disk-corona relations, typical of active galactic nuclei, inferred from both the optical and radio fluxes. They are instead compatible with the X-ray emission predicted for normal galaxies. After careful consideration of potential biases, we identified that this X-ray weakness needs a physical origin. A possibility is that a canonical X-ray corona might be lacking in the majority of this population of UVOIR-variability selected low-mass galaxies or that unusual accretion modes and spectral energy distributions are in place for MBHs in dwarf galaxies. This result reveals the potential for severe biases in occupation fractions derived from data from only one waveband combined with SEDs and scaling relations of more massive black holes and galaxies.

Astronomy & Astrophysics

High-throughput micro-scale bandgap mapping for perovskite-inspired materials with complex composition space

Abstract To realize the full promise of high-throughput experimental workflows, the rate of sample synthesis must be matched by that of characterization. Of growing interest are contactless optical techniques that can rapidly measure material homogeneity and properties. Here, we present a hyperspectral imaging method to measure local optical bandgap distributions within samples, utilizing spatially-resolved reflectance spectra coupled with automated data analysis. We collect approximately one million optical bandgap data across the compositional space of Cs 3 (Bi x Sb 1-x ) 2 (Br y I 1-y ) 9 perovskite-inspired materials. Our results show non-monotonic bandgap variations (i.e., bandgap bowing) along six composition gradient sequences, in addition to identifying samples with multiple bandgaps in statistics. High-throughput transient absorption spectroscopy reveals that within these compositions, the depletion of the ground state carriers to excited states occurred at discrete energy levels with independent carrier dynamics, consistent with the bandgap observation and indicative of phase separation. This work demonstrates the potential for rapid optical measurements to assess material quality and homogeneity in a high-throughput experimental setting, supporting screening and recipe optimization of optoelectronic material candidates with desired carrier dynamics and optical properties.

Science & Technology - Other Topics