Search NASA⌕ Search

SEARCH · Search NASA

Results for “Impacts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Impact Testing of 410 Stainless Steel for Material Impact Model Development

A project is underway to develop a consistent set of material properties, impact test data, and failure analysis for a variety of metallic aircraft materials that can be used to develop improved impact failure and deformation models. This project is jointly funded by the NASA Glenn Research Center and the Federal Aviation Administration William J. Hughes Technical Center. Particular features of this set of data are that all material property and impact test data are obtained using traceable material, the test methods and procedures are extensively documented, and all the raw data are available. Four parallel efforts are currently underway: measurement of material deformation and failure response over a wide range of strain rates and temperatures, failure analysis of material property specimens and impact test articles, development of improved numerical modeling techniques for deformation and failure, and impact testing of flat panels and substructures for model validation. This report describes impact testing performed on 410 stainless steel sheet and plate samples of different thicknesses with two different types of projectiles, one a regular cylinder and one with a more complex geometry incorporating features representative of a jet engine fan blade. Data from this testing will be used in validating material models developed under this program. The material tests and the material models developed in this program will be published in separate reports.

410 Stainless Steel↗

Impacts of Anisotropic Porosity on Heat Transfer and Off-Gassing during Biomass Pyrolysis

The pore structure of biogenic materials imbues the ability to deliver water and nutrients through a plant from root to leaf. This anisotropic pore granularity can also play a significant role in processes such as biomass pyrolysis that are used to convert these materials into useful products like heat, fuel, and chemicals. Evolutions in modeling of biomass pyrolysis as well as imaging of pore structures allow for further insights into the concerted physics of phase change-induced off-gassing, heat transfer, and chemical reactions. In this work, we report a biomass single particle model which incorporates these physics to explore the impact of implementing anisotropic permeability and diffusivity on the conversion time and yields predicted for pyrolysis of oak and pine particles. Simulation results showed that anisotropic permeability impacts predicted conversion time more than 2 times when the Biot number is above 0.1 and pyrolysis numbers (Py 1 , Py 2 ) are less than 20. Pore structure significantly impacts predicted pyrolytic conversion time (>8 times) when the Biot number is above 1 and the pyrolysis number is below 1, i.e., the “conduction controlled” regime. Therefore, these nondimensional numbers reflect that when internal heat conduction limits pyrolysis performance, internal pyrolysis off-gassing further retards effective heat transfer rates as a closely coupled phenomenon. Overall, this study highlights physically meaningful opportunities to improve particle-scale pyrolysis modeling and experimental validation relevant to a variety of feedstock identities and preparations, guiding the future design of pyrolyzers for efficient biomass conversion.

09 BIOMASS FUELS↗

Impacts of Voltage-Based Grid Support Functions on Energy Production of PV Customers

This paper presents the impact of inverter grid- support functions (GSFs) on photovoltaic (PV) customer energy production on a real distribution feeder in Oahu, HI. These autonomous GSFs based on local voltage measurements are good alternatives to increase PV hosting capacity. However, these functions can result in PV energy curtailment to the customer, and this study addresses the concerns about the impact of inverter GSFs through detailed quasi-static time series (QSTS) simulations. It proposes four metrics: maximum and average GSF curtailment, average increased generation and average net generation change, to assess the impact of a given control on PV systems located on customer sites. It was found that curtailment of PV production is negligible for customers where peak voltage is within ANSI C84.1 range. A reliable relationship between curtailment and peak customer voltage is demonstrated, suggesting that peak voltage could be used as an indicator of customer curtailment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Grounding our Understanding of the Impacts of Boreal Forest Expansion on Shallow Cumulus Clouds with a Simple Modeling Framework

Abstract The expansion of the boreal forest poleward is a potentially important driver of feedbacks between the land surface and Arctic climate. A growing body of work has highlighted the importance of differences in evaporative resistance between different possible future Arctic land covers, which in turn alters humidity and cloudiness in the boundary layer, for these feedbacks. While thus far this problem has been studied primarily with complex Earth system models, we turn to a locally focused, idealized model capable of diagnosing and testing the sensitivity of first-order processes connecting vegetation, the atmospheric boundary layer, and low clouds in this critical region. This allows us to benchmark the mechanisms and results at the center of predictions from larger-scale simulations. A surface dominated by broadleaf trees, characterized by higher albedo and lower surface evaporative resistance, drives cooling and moistening of the boundary layer relative to a surface of needleleaf trees, characterized by lower albedo and higher surface evaporative resistance. Differences in evaporative resistance between these hypothetical Arctic vegetation covers are of equal importance to changes in albedo for the initial response of the boundary layer to boreal expansion, even with our idealized approach. However, compensation between the elevation of the lifting condensation level (LCL) and more rapid growth of the mixed layer over higher evaporative resistance surfaces can minimize changes in the favorability of shallow clouds over different land cover types under some conditions. We then perform two tests on the sensitivity of this compensating effect, to changes in water availability, represented first by a reduction in boundary layer humidity and then by both a reduction in humidity and soil moisture available to our vegetation surface. Finally, given the importance of this potential LCL–mixed-layer height compensation in our idealized modeling results, we look to determine its relevance in observational data from a field campaign in boreal Finland. These observations do confirm that such a coupling plays an important role in cumulus-topped boundary layers over a needleleaf forest surface. While our results confirm some underlying mechanisms at the center of prior work with Earth system models, they also provide motivation for future work to constrain the impact of boreal forest expansion. This will include both large eddy simulations to examine the impact of processes and feedbacks not resolved by a mixed-layer model, as well as a more systematic evaluation and comparison of relevant observations at the site in Finland and sites from prior boreal field campaigns. Significance Statement Clouds and vegetation are both important components of the climate system that interact across a range of scales. These interactions are central to understanding how changes at the land surface feedback on climate. For example, if a forest expands or recedes, diagnosing how that will impact clouds will determine whether you predict warming or cooling temperatures from that shift in the forest area. These predictions are often made with complex Earth system models, but we look to a more idealized representation of the land–atmosphere system to diagnose how shallow clouds should respond to changes in surface properties with different scenarios of boreal forest expansion at a more foundational level. This both grounds our understanding of previous analysis and provides helpful direction for future studies of this relevant and impactful land cover change.

Meteorology & Atmospheric Sciences↗

Using Demanded Power and RDE Aggressiveness Metrics to Analyze the Impact of CACC Aggressiveness on Heavy Duty Platooning Power Consumption

Presently, a main mobility sector objective is to reduce its impact on the global greenhouse gas emissions. While there are many techniques being explored, a promising approach to improve fuel economy is to reduce the required energy by using slipstream effects. This study analyzes the demanded engine power and mechanical energy used by heavy-duty trucks during platooning and non-platooning operation to determine the aerodynamic benefits of the slipstream. A series of platooning tests utilizing class 8 semi-trucks platooning via Cooperative Adaptive Cruise Control (CACC) are performed. Comparing the demanded engine power and mechanical energy used reveals the benefits of platooning on the aerodynamic drag while disregarding any potential negative side effects on the engine. However, energy savings were lower than expected in some cases. It was hypothesized that the CACC may have amplified transient platooning events relative to the individual truck baseline results, hampering the potential energy savings. Therefore, the impact of the controller on the observed driving style was analyzed in detail. In order to quantify the transient operational characteristics of the experimental trials, metrics from the European Real Driving Emissions (RDE) legislation were modified to serve as metrics of aggressiveness during platooning. The metrics (v · apos)95 and Relative Positive Acceleration (RPA) were calculated for platooning and non-platooning runs. These results indicate that the CACC induces small acceleration events during platooning to retain the commanded longitudinal separation between vehicles. These small acceleration events increase following vehicle aggressiveness during platooning and prevent the following vehicles from obtaining maximum energy savings. Moreover, a correlation between the RDE metric (v · apos)95 and energy savings is developed. Hence, this work establishes the ability of RDE metrics to assess CACC impacts on platoon energy savings.

European Real Driving Emissions, RDE, greenhouse g↗

The Manson impact structure, a possible site for a Cretaceous-Tertiary (K-T) boundary impact

The Manson impact structure, about 35 km in diameter, is the largest impact crater recognized in the United States. Its center is located near the town of Manson, 29 km west of Fort Dodge, Iowa. The structure is not well known geologically because it is covered by tens of meters of glacial deposits. What is known about the structure was learned mostly from the study of water well cuttings. At Manson the normal Phanerozoic and Proterozoic sedimentary rocks were replaced by centrally uplifted Proterozoic crystalline rocks that are representative of the normal basement: This central uplift is surrounded by completely disrupted rocks which are roughly encircled by peripherally faulted and slumped sequences of normal sedimentary strata. Radially outward normal sedimentary strata are uplifted slightly. Manson, once interpreted as a cryptovolcanic structure, is now considered an impact structure based on its circular shape, its central uplift and the presence of multiple intersecting sets of shock lamellae in quartz grains from the central uplift. The Ar-40/Ar-39 age spectrum dating results for a microcline separate from the Manson 2-A core in the central uplift is shown. This spectrum is interpreted to indicate a nearly complete degassing of the microcline at the time of the Manson impact. The remainder of the gas released climbs in age with increasing temperature of release. This pattern of the age spectrum is interpreted to represent diffusional loss due to reheating at the time of the impact and during subsequent cooling. Shocked quartz grains, present in the iridium-bearing layer at the K-T boundary throughout the world, have a significantly larger size and are more abundant in the western interior of North America than elsewhere in the world. Furthermore, shocked feldspar and granitic fragments are found at the K-T boundary in North America. These observations indicate the K-T boundary impact must have penetrated continental crust in North America.

Hartung, J. B.↗

Comparison of Os and Cr Isotopic Methods for the Detection of Meteoritic Components in Impact Melt Rocks from the Morokweng and Vredefort Impact Structures, South Africa

The verification of an extraterrestrial component in impact-derived melt rocks or breccias can be of diagnostic value to provide confirming evidence for an impact origin of a geological structure. Geochemical methods are used to determine the presence of the traces of such a component. In the absence of actual meteorite fragments, it is necessary to search for traces of meteoritic material that is mixed in with the target rocks in breccias and melt rocks. Meteoritic components have been identified for just over 40 impact structures (out of more than 160 known on Earth), which reflects also the detail in which these structures were studied. The identification of a meteoritic component can be achieved by determining the concentrations and interelement ratios of siderophile elements, especially the platinum group elements (PGE), which are several orders of magnitude more abundant in meteorites than in terrestrial upper crustal rocks. The usage of platinum group element abundances and ratios avoids some of the ambiguities that may result if only common siderophile elements (e.g., Cr, Co, Ni) are considered. However, problems may arise if the target rocks have high abundances of siderophile elements, or if the siderophile element concentrations in the impactites are very low. In such cases, the Os and Cr isotopic systems have recently been used for establishing the presence of a meteoritic component in a number of impact melt rocks and breccias. In the past it was attempted to use PGE data to determine the type or class of meteorite for the impactor, but these attempts were not always successful. It is difficult to decide between chondrite types based on PGE abundances, which has led to conflicting identifications for a number of impact structures. Clearly, the identification of a meteoritic component in impactites is not a trivial problem. In this study, we are using a combination of trace element (PGE) analyses and the results from both, Os and Cr isotopic studies, to illustrate the pros and cons of each method on two case studies, namely the Vredefort and Morokweng impact structures. Additional information is contained in the original extended abstract.

Koeberl, Christian↗

Evaluating the Impact of Residential Solar Contract Cancellations in the United States

The residential solar photovoltaic (PV) market in the United States is growing, despite frequent customer cancellations. Contract cancellations result in lost time and costs that must be borne by installers, often in the form of higher "soft costs" (i.e., non-equipment costs). These costs are often passed on to customers who successfully install PV systems. To date, few studies have attempted to estimate national cancellation rates or model the impacts on installed system costs. In this report, we utilize an installer-provided dataset of 199,665 residential PV-only projects representing about 10% of U.S. installs each year from 2017-2019. With this data, we evaluate cancellation rates and trends from contract signing to install. Next, by leveraging NREL's soft cost model for residential solar, we estimate installer spending through each phase of the pre-install process. Applying our findings on cancellation timelines and rates, we then estimate the potential cost impacts to successful installs from contract cancellations. Our work suggests that the rates and impacts of contract cancellations have been previously underestimated. Namely, we find that cancellations/unsuccessful project are; more common than previous estimates suggest; occur earlier in project timelines, though a significant number happen even after permit/ATB approvals; and contribute significantly to customer acquisition and other soft costs. We also find that cancellation do not appear to be driven by review delays in permitting and interconnection applications.

14 SOLAR ENERGY↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Impact gages for detecting meteoroid and other orbital debris impacts on space vehicles.

Impacts on space vehicles have been simulated using the McDonnell Douglas Aerophysics Laboratory (MDAL) Light-Gas Guns to launch particles at hypervelocity speeds into scaled space structures. Using impact gages and a triangulation technique, these impacts have been detected and accurately located. This paper describes in detail the various types of impact gages (piezoelectric PZT-5A, quartz, electret, and off-the-shelf plastics) used. This description includes gage design and experimental results for gages installed on single-walled scaled payload carriers, multiple-walled satellites and space stations, and single-walled full-scale Delta tank structures. A brief description of the triangulation technique, the impact simulation, and the data acquisition system are also included.

Mastandrea, J. R.↗

Impact cratering phenomenon for the Ries multiring structure based on constraints of geological, geophysical, and petrological studies and the nature of the impacting body

In the present paper, an attempt is made to delineate, on the basis of field and laboratory data, the phenomenon of formation of the Ries multiring basin - the best preserved very large terrestrial impact structure. The model proposed conforms to constraints imposed by geological, geophysical, and petrological studies and by the nature of the postulated impacting body. It is also based on the impact features of a stony meteorite measuring 3 km in diameter at an impact velocity of 15 km/sec. The schematic reconstruction shows that critical to the production of a shallow crater is shallow impact penetration (shallow depth of burst). This and the nonballistic ejection of excavated material appear to be genetically related, i.e., if extensive nonballistic transport is recognized, then the associated crater must be a shallow structure and vice versa. This also means the shallow configuration of a crater may not have anything to do with postcratering readjustment.

Chao, E. C. T.↗

Impacts of hemispherical granular targets: Implications for global impacts

As impact excavation diameters subtend a nontrivial fraction of a planetary body, both the excavation process and ejecta emplacement may depart form the classical description of impacts into a planar surface. Hemispherical particulate targets were impacted at the NASA-Ames Vertical Gun Range in order to trace the evolution of the ejecta curtain and to document the effects of slope and surface curvature on crater shape and cratering efficiency. The experiments suggest that basin size impacts or large craters on small bodies may be shallower than their counterparts on a planar surface but may have displaced a larger relative mass. Moreover, the increased ejecta curtain angle with distance may result in a change in ejecta emplacement style with distance. Although the ejecta curtain is vertical, ejecta within the curtain impact the surface at 45 deg and the time between first and last arrival within the curtain increases. This increased interaction time as the ejecta curtain density decreases should result in a more chaotic style of implacement.

Schultz, P. H.↗

Hypervelocity impact study: The effect of impact angle on crater morphology

The Space Power Institute (SPI) of Auburn University has conducted preliminary tests on the effects of impact angle on crater morphology for hypervelocity impacts. Copper target plates were set at angles of 30 deg and 60 deg from the particle flight path. For the 30 deg impact, the craters looked almost identical to earlier normal incidence impacts. The only difference found was in the apparent distribution of particle residue within the crater, and further research is needed to verify this. The 60 deg impacts showed marked differences in crater symmetry, crater lip shape, and particle residue distribution. Further research on angle effects is planned, because the particle velocities for these shots were relatively slow (7 km/s or less).

Crawford, Gary↗

An analysis of differential impact melt-crater scaling and implications for the terrestrial impact record

The volume of impact melt relative to that of the transient cavity is known to increase with the magnitude of the impact event. This paper investigates the influence of that phenomenon on the nature of terrestrial impact craters. A model of impact melting was used to estimate the volume of melt produced during the impact of chondritic projectiles into granite targets at velocities of 15, 25, and 50 km per sec. The results were compared with observed melt volumes at terrestrial craters, which were collated from the literature and paired with the transient-cavity diameters of their respective craters. Results show that the record on terrestrial craters is not inconsistent with the predictions of the model.

Grieve, R. A. F.↗

Jupiter After the 2009 Impact: Hubble Space Telescope Imaging of the Impact-Generated Debris and Its Temporal Evolution

We report Hubble Space Telescope images of Jupiter during the aftermath of an impact by an unknown object in 2009 July, The 2009 impact-created debris field evolved more slowly than those created in 1994 by the collision of the tidally disrupted comet D/Shoemaker-Levy 9 (SL9). The slower evolution, in conjunction with the isolated nature of this single impact, permits a more detailed assessment of the altitudes and meridional motion of the debris than was possible with SL9. The color of the 2009 debris was markedly similar to that seen in 1994, thus this dark debris is likely to be Jovian material that is highly thermally processed. The 2009 impact site differed from the 1994 SL9 sites in UV morphology and contrast lifetime; both are suggestive of the impacting body being asteroidal rather than cometary. Transport of the 2009 Jovian debris as imaged by Hubble shared similarities with transport of volcanic aerosols in Earth's atmosphere after major eruptions.

Hammel, H. B.↗