Search NASASearch

SEARCH · Search NASA

Results for “In-Flight laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Instrumentation concepts and requirements for a space vacuum research facility

An earth-orbiting molecular shield that offers a unique opportunity for conducting physics, chemistry, and material processing experiments under a combination of environmental conditions that are not available in terrestrial laboratories is equipped with apparatus for forming a molecular beam from the freestream. Experiments are carried out using a moderate energy, high flux density, high purity atomic oxygen beam in the very low density environment within the molecular shield. As a minimum, the following instruments are required for the molecular shield: (1) a mass spectrometer; (2) a multifunction material analysis instrumentation system; and (3) optical spectrometry equipment. The design is given of a furlable molecular shield that allows deployment and retrieval of the system (including instrumentation and experiments) to be performed without contamination. Interfaces between the molecular shield system and the associated spacecraft are given. An in-flight deployment sequence is discussed that minimizes the spacecraft-induced contamination in the vicinity of the shield. Design approaches toward a precursor molecular shield system are shown.

Norton, H. N.

Exploration of Neutron-Rich Isotopes around N = 50 via the In-Flight Fission of a 345 MeV/Nucleon 238 U Beam

A search for new neutron-rich isotopes beyond $Z=28$ and $N=50$ was performed using a 345 MeV/nucleon $^{238}$U beam at RI Beam Factory in RIKEN Nishina Center. The BigRIPS separator and state-of-the-art radiation detectors were used to efficiently separate and identify the produced nuclei. For the first time, we have observed and determined the production cross sections for eight neutron-rich isotopes $^{72}$Cr, $^{74,75}$Mn, $^{77}$Fe, $^{79,80}$Co, $^{85}$Cu, and $^{90}$Ga. This study broadens our understanding of nuclear existence and paves the way for investigating the properties of neutron-rich medium-mass nuclei.

Shimizu, Yohei [RIKEN, Saitama (Japan); et al.]

Hybrid PDES Simulation of HPC Networks Using Zombie Packets

Although high-fidelity network simulations have proven to be reliable and cost-effective tools to peer into architectural questions for high-performance computing (HPC) networks, they incur a high resource cost. The time spent in simulating a single millisecond of network traffic in the highest detail can take hours, even for static, well-behaved traffic patterns such as uniform random. Surrogate models offer a significant reduction in runtime, yet they cannot serve as complete replacements and should only be used when appropriate. Thus, there is a need for hybrid modeling, where high-fidelity simulation and surrogates run side-by-side. Here, we present a surrogate model for HPC networks in which: packets bypass the network, while the network state is left untouched, i.e., suspended. To bypass the network, we use historical data to estimate the arrival time at which every packet should be scheduled at; to suspend the network, all in-flight packets are scheduled to arrive at their destinations, and are kept in the system to awaken as zombies when switching back to high-fidelity. Speedup for a hybrid model is relative to the proportion of surrogate to high-fidelity. This light-weight surrogate obtained up to 76× speedup. Keeping the zombies in the network showed an increase in the accuracy of the high-fidelity simulation on restart when compared to restarting the network from an empty state.

HPC networks

An accurate measurement of the spectral resolution of the JWST Near Infrared Spectrograph

The spectral resolution (R ≡ λ/Δλ) of spectroscopic data is crucial information for accurate kinematic measurements. In this letter we present a robust measurement of the spectral resolution of the JWST Near Infrared Spectrograph (NIRSpec) in fixed slit (FS) and integral field spectroscopy (IFS) modes. Due to the similarity of the utilized slit dimension in the FS mode to that of the shutters in the multi-object spectroscopy (MOS) mode, our resolution measurements in the FS mode can also be used for the MOS mode in principle. We modeled H and He lines of the planetary nebula SMP LMC 58 using a Gaussian line spread function (LSF) to estimate the wavelength-dependent resolution for multiple disperser and filter combinations. We corrected for the intrinsic width of the planetary nebula’s H and He lines due to its expansion velocity by measuring it from a higher-resolution X-shooter spectrum. We find that NIRSpec’s in-flight spectral resolutions exceed the pre-launch estimates provided in the JWST User Documentation by 11–53% in the FS mode and by 1–24% in the IFS mode across the covered wavelengths. We recover the expected trend that the resolution increases with the wavelength within a configuration. The robust and accurate LSFs presented in this letter will enable high-accuracy kinematic measurements using NIRSpec for applications in cosmology and galaxy evolution.

methods: data analysis

Ground calibration and in-flight commissioning of the Gamma-Ray and Neutron Spectrometer (GRNS) for NASA’s Psyche mission

NASA's Psyche spacecraft is currently enroute to the asteroid 16 Psyche, where it will perform an orbital investigation focused on determining the nature of the asteroid. A key part of this investigation is measurements of elemental composition to determine if the asteroid is rich in iron-nickel metal. To that end, the Psyche spacecraft payload includes a Gamma-Ray and Neutron Spectrometer (GRNS). GRNS is composed of two subsystems; a Gamma-Ray Spectrometer (GRS) with a high-purity germanium γ-ray sensor surrounded by a borated plastic scintillator Anti-Coincidence Shield (ACS), and a Neutron Spectrometer (NS) with three 3 He-filled gas proportional counters that are sensitive to different neutron energy regimes. We describe results from the pre-launch calibration campaign, along with early in-flight results from post-launch instrument commissioning. The information detailed here is focused on providing future users of GRNS data with the information needed to properly interpret the observations from the instrument.

Peplowski, Patrick N. [Johns Hopkins Univ., Baltim

In-orbit performance of the soft X-ray imaging telescope Xtend aboard XRISM

Here, we present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently operating X-ray observatories. XRISM/Xtend has a large field of view of ${38{^{\prime }_{.}}5}$ $\times$ ${38{^{\prime }_{.}}5}$, covering an energy range of 0.4–13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170–180 eV at 6 keV, which meets the mission requirement and enables us to resolve He-like and H-like Fe K$\alpha$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in the Soft X-ray Imager (SXI) onboard the previous Hitomi mission—light leakage and crosstalk events—are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C 273 results in an effective area measured to be $\sim$420 cm$^{2}$ at1.5 keV and $\sim$310 cm$^{2}$ at 6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations; the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared with other major X-ray instruments onboard satellites, combined with the largest grasp ($\Omega _{\rm eff}\sim 60$ cm$^2$ deg$^2$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near-future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

instrumentation: detectors: Xtend

In-flight performance of S PIDER'S 280-GHz receivers

S PIDER is a balloon-borne instrument designed to map the cosmic microwave background at degree-angular scales in the presence of Galactic foregrounds. S PIDER has mapped a large sky area in the Southern Hemisphere using more than 2000 transition-edge sensors (TESs) during two NASA Long Duration Balloon flights above the Antarctic continent. During its first flight in January 2015, S PIDER observed in the 95 GHz and 150 GHz frequency bands, setting constraints on the B-mode signature of primordial gravitational waves. Its second flight in the 2022-23 season added new receivers at 280 GHz, each using an array of TESs coupled to the sky through feedhorns formed from stacks of silicon wafers. Here, these receivers are optimized to produce deep maps of polarized Galactic dust emission over a large sky area, providing a unique data set with lasting value to the field. In this work, we describe the instrument’s performance during S PIDER'S second flight.

280 GHz cosmology

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics

Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.

Astronomy and AstroPhysics

Predicted vibration responses of Apollo structure and effects of pressure correlation lengths on response

Progressive wove and reverberant acoustic fields ore often used in the laboratory for qualification testing of aerospace structures that are subjected to unsteady aerodynamic environments which occur during flight through the atmosphere. Acoustic simulation of these in-flight environments i s achieved i f the structural vibration response to acoustic excitation is equivalent, over the frequency range of interest, to the response caused by aerodynamic turbulence. To determine the degree of response simulation that could be expected for such qualification testing of the Apollo Spacecraft, responses of a segment of the Apollo structure were estimated theoretically for both acoustic and flight environments. The vibration analysis presented in this report was performed for the Spacecraft Lunar Module Adaptor; and the three environments treated are turbulence at Mach 1 and Mach 2, a reverberant acoustic field, and a modified acoustic progressive wave field. The progressive wave field is assumed to be generated within a specially designed shroud of sixteen axially oriented ducts which is constructed around and contoured to the external skin of the vehicle. Each duct is open on the side adjacent to the skin and is driven acoustically at one end by an independent noise source, thus allowing for different pressure correlation patterns around the circumference of the vehicle. The purpose of the analysis was to determine the effects of surface pressure correlation lengths on the response characteristics of representative Apollo structure, and to select on this basis, the optimum acoustic environment for structural vibration qualification tests of the Apollo in the Spacecraft Acoustic Laboratory at MSC. The method of analysis employed consists of determining, independently, the space average, mean-square acceleration spectral density for each of the significant modes of vibration of an equivalent cylindrical shell, and then expressing the total structural response as a linear summation of these modal responses. Approximately 570 classical modes of a pinned-end cylinder were used in order to find the spectral response characteristics of the structure throughout the frequency range of 10 - 1,000 Hz. The effective forcing functions or joint acceptances of the various modes of vibration were computed and are presented graphically for each of the pressure excitation environments. A brief development of the response equations used is presented in the report. Space average acceleration response spectra were computed for twelve different cases including aerodynamic turbulence at Mach 1 and Mach 2, reverberant acoustic field, five duct correlation patterns, two cases of an axially damped progressive wave field, and two cases in which the structural damping constant was varied from the expected value. The response spectra were computed and plotted by a high speed digital computer far a flat excitation pressure spectrum; and the response spectra were numerically integrated to give one-third octave bond average responses. A complete set of digital computer programs has been developed for both flat plate and cylindrical shell structures for the above environments, and each requires run times of three minutes or less. Thus, the work presented herein, along with the results, constitutes a practical advancement to the existing state-of-the-art of vibration prediction.

R W White

Design and flight testing of a nullable compressor face rake

A compressor face rake with an internal valve arrangement to permit nulling was designed, constructed, and tested in the laboratory and in flight at the NASA Flight Research Center. When actuated by the pilot in flight, the nullable rake allowed the transducer zero shifts to be determined and then subsequently removed during data reduction. Design details, the fabrication technique, the principle of operation, brief descriptions of associated digital zero-correction programs and the qualification tests, and test results are included. Sample flight data show that the zero shifts were large and unpredictable but could be measured in flight with the rake. The rake functioned reliably and as expected during 25 hours of operation under flight environmental conditions and temperatures from 230 K (-46 F) to greater than 430 K (314 F). The rake was nulled approximately 1000 times. The in-flight zero-shift measurement technique, as well as the rake design, was successful and should be useful in future applications, particularly where accurate measurements of both steady-state and dynamic pressures are required under adverse environmental conditions.

Holzman, J. K.

Further laboratory studies and stratospheric flight of a mass spectrometer beam system

A gas expansion system combined with a mass spectrometer has been tested and flown successfully in the stratosphere. Through a sequence of orifices and high speed pumping, gas particles were formed into a molecular beam and analyzed by a sensitive mass spectrometer. During two balloon flights, vertical profiles of all major atmospheric constituents as well as O3, CO2, H2O and others were obtained. Gases such as AR38 and O16;O17 provided in-flight calibration standards. The sensitivity of the system was such that gases with mixing ratios of 10 ppb at an ambient pressure of about 10 mbar were detectable.

Mauersberger, K.

MIZEX-WEST NASA CV-990 flight report

As part of the Bering Sea marginal ice zone winter experiment (MIZEX-WEST), the CV-990 airborne laboratory was flown to assess the potential of using an extended range of wavelengths for improving passive microwave sea ice observations from spacecraft and second to provide an overview of the MIZ for large-scale processes studies. The aircraft was equipped with both imaging and fixed-beam, dual-polarized passive microwave radiometers ranging from 1.5 millimeter to 3 centimeter wavelengths. Visual, photographic, and thermal (10.7 micron) infrared surface observations were also made from the aircraft to complement the microwave measurements. The flight operations and in-flight observations are discussed and each flight is summarized including flight objective and instrument status. Preliminary mosaic images obtained with the ESMR imager, Nimbus-7 orbits over the Bering Sea, ice observations obtained by an ice observer on board, and composite maps of the general ice conditions for the month of February are also presented.

Cavalieri, D. J.

Mass spectrometry in the stratosphere

A gas expansion system incorporating a mass spectrometer that has been successfully flown in the stratosphere is described. Neutral gas particles are formed into a molecular beam that traverses the ion source of the mass spectrometer without wall interactions. It is noted that vertical profiles of such constituents as H2O, CO2, and O3 have been measured in the altitude range of 20 to 40 km during balloon descents. Isotopes of important gases (N2, O2, Ar) provided in-flight calibration standards. Before each flight the mass spectrometer system is calibrated in the laboratory for many gases of interest, including ozone. Mixing ratios of ozone established from recent flights have accuracies of better than 5 percent. The sensitivity of the system is sufficient to detect as well the heavy isotope of ozone at mass 50. A noticeable enhancement of heavy ozone in the upper stratosphere has been found. The mass spectrometer system is seen as providing a unique opportunity to perform in situ measurements in the stratosphere in combination with isotopic studies.

Mauersberger, K.

Airflow calibration and exhaust pressure/temperature survey of an F404, S/N 215-109, turbofan engine

A General Electric F-404 turbofan engine was calibrated for thrust and airflow at the NASA Lewis Propulsion System Laboratory in support of future flight tests of the X-29 aircraft. Tests were conducted with and without augmentation, over a range of flight conditions, including the two design points of the airplane. Data obtained during the altitude tests will be used to correct two independent gross thrust calculation routines which will be installed and operated on the airplane to determine in-flight gross thrust. Corrected airflow data as a function of corrected fan speed collapsed onto a single curve. Similarly, trends were observed and defined for both augmented and dry thrust. Overall agreement between measured data and F-404 Engine Spec Deck data was within 2 percent for airflow and 6 percent for thrust. The results of an uncertainty analysis for thrust and airflow is presented. In addition to the thrust calibration, the exhaust gas boundary layer pressure and temperatures were surveyed at selected condition and engine power levels to obtain data for another NASA F-404 program. Test data for these surveys are presented.

Burns, Maureen E.

System level verification applying the Space Shuttle experience to the Space Station

The applicability of the verification process for the Shuttle guidance, navigation and control (GNC) and data management system (DMS) for the development of the Space Station are described. Shuttle avionics hardware/software integration was delayed to finalize the hardware design before detailed definition and testing of the software. A block diagram is provided of the flight simulation laboratory used to test the GNC programs before flight data were available. The Station will have distributed computers, unlike the Orbiter, and will only be assembled fully in space. Standardized integration simulation test equipment are being defined to guide the development of hardware and software. The simulation capability may become part of nominal in-flight operations to initiate new capabilities as they are added to the Station. The Station GNC and DMS systems development will be somewhat simplified relative to those of the Shuttle because ascent and reentry will not be considered for the Station.

Gilbert, David W.

In-flight radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

A reflectance-based method was used to provide an analysis of the in-flight radiometric performance of AVIRIS. Field spectral reflectance measurements of the surface and extinction measurements of the atmosphere using solar radiation were used as input to atmospheric radiative transfer calculations. Five separate codes were used in the analysis. Four include multiple scattering, and the computed radiances from these for flight conditions were in good agreement. Code-generated radiances were compared with AVIRIS-predicted radiances based on two laboratory calibrations (pre- and post-season of flight) for a uniform highly reflecting natural dry lake target. For one spectrometer (C), the pre- and post-season calibration factors were found to give identical results, and to be in agreement with the atmospheric models that include multiple scattering. This positive result validates the field and laboratory calibration technique. Results for the other spectrometers (A, B and D) were widely at variance with the models no matter which calibration factors were used. Potential causes of these discrepancies are discussed.

Conel, James E.