Search NASA⌕ Search

SEARCH · Search NASA

Results for “Indoor simulators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Machine Learning-Assisted Framework to Control Thermally Anisotropic Building Envelopes in Residential Buildings

To curb the energy consumption of buildings and their related CO2 emissions, Oak Ridge National Laboratory (ORNL) has developed the thermally anisotropic building envelope (TABE) —a multi-layer design comprising insulation materials and metal foils connected to thermal loops. In this study, a machine learning-assisted framework was developed to control the TABE in residential buildings to reduce the computation load for future optimal rule-based control and application. First, a 2D finite element model was established in COMSOL to calculate the hourly heat flux through exterior walls installed with the TABE. Then, TABE wall heat fluxes were simulated for various given indoor and outdoor boundary conditions, as well as thermal loops fluid temperatures and flow rates. Since the finite element simulations are computationally expensive, an artificial neural network (ANN) was then trained to use as a proxy of the finite element (COMSOL) modeling. Finally, the trained ANN model was coupled with the EnergyPlus model to predict the energy consumption of a US Department of Energy prototype single-family house installed with the TABE. An optimal simple rule-based control was determined from predefined rules for a case study. The results demonstrate that the developed machine learning–assisted framework can reduce 99.9% of the computation time while efficiently managing residential building energy for installed TABE walls.

Shen, Zhenglai↗

Backscattering properties of simulated geological surfaces

A simple, compact, indoor measurement system has been developed to study the radar backscattering properties of a variety of simulated geological surfaces and volumes. The media include a homogeneous layer of fine sand observed for various levels of surface roughness, a sand layer covered with a layer of rocks, and a layer of rocks sandwiched between layers of sand. Four different sizes of rocks were investigated varying from about 1 cm in size to 6 cm in size. The results provide information on the penetration depth of sand, the relative importance of the coherent and incoherent backscattering components, and the magnitude of volume scattering by a layer of rocks relative to surface scattering by a random surface.

East, J.↗

Simulation-based assessment of ASHRAE Guideline 36, considering energy performance, indoor air quality, and control stability

This study assesses American Society of Heating, Refrigerating and Air-Conditioning Engineers Guideline 36 (G36) with a typical medium office building. Specifically, this study employed a Modelica model of a variable air volume (VAV) system that serves this building, which includes components for representing indoor virus transmission and filtration. It then implemented the G36 control sequences for both water-side and air-side equipment in Python. After that, this study conducted the assessment by co-simulating G36 and the Modelica model using the Building Operations Testing Framework. Unlike existing works, this work has three unique features: (1) It considers the interactions between control sequences for water-side and air-side equipment of the studied VAV system. (2) It assesses the performance of G36 from the perspective of IAQ. (3) It examines the short-term behaviors of the studied building under G36 to understand the control stability. This assessment confirms significant energy savings from G36, largely because of the interaction between supply air temperature and hot water controls. It also reveals a trade-off between the ability to slow the spread of virus and the energy performance via demand controlled ventilation. Lastly, it emphasizes the necessity of tuning local feedback control when implementing G36.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Indoor Wireless Localization of Uncooperative Sources Using a Ray Tracing Model

Indoor geolocation of radio frequency (RF) trans- mitters is challenging due to site-specific multipath effects, especially when the sources are uncooperative. A source being uncooperative means that a-priori the transmit time, location, and power are unknown. It is proposed to use a site-specific ray tracing model to generate realistic indoor RF responses, perform geolocation using multiple methods, and compare their performance. This work will look at two types of geolocation algorithms: (1) time-difference of arrival (TDOA) and (2) re- ceived signal strength Indicator (RSSI) fingerprinting or pattern- matching-based methods. An indoor space will be simulated with a grid of fixed receivers and a grid of transmit locations using Remcom’s Wireless InSite. Using the output of the Wireless InSite simulation the response from any given transmit location can be generated and used to evaluate geolocation performance.

indoor source localization, Wireless InSite, re- c↗

Classroom aerosol dispersion modeling: experimental assessment of a low-cost flow simulation tool

The purpose of this study was to assess the utility of a low-cost flow simulation tool for an indoor air modeling application by comparing its outputs with the results of a physical experiment, as well as those from a more advanced computational fluid dynamics (CFD) software package. In this study, five aerosol dispersion tests were performed in two different classrooms by releasing a CO 2 tracer gas from six student locations. Resultant steady-state concentrations were monitored at 13 locations around the periphery of the room. Subsequently, the experiments were modeled using both a low-cost tool (SolidWorks Flow Simulation) and a more sophisticated tool (STAR-CCM+). Models were evaluated based on their ability to predict the experimentally measured concentrations at the 13 monitoring locations by calculating four performance parameters commonly used in the evaluation of dispersion models: fractional mean bias (FB), normalized mean-square error (NMSE), fraction of predicted value within a factor of two (FAC2), and normalized absolute difference (NAD). The more sophisticated model performed better in 15 of the 20 possible cases (five tests at four parameters each), with parameters meeting acceptance criteria in 19 of 20 cases. However, the lower-cost tool was only slightly worse, with parameters meeting acceptance criteria in 18 of 20 cases, and it performed better than the other tool in 3 of 20 cases. Because it provides useful results at a fraction of the monetary and training cost and is already widely accessible to many institutions, such a tool may be worthwhile for many indoor aerosol dispersion applications, especially for students or researchers just beginning CFD modeling.

54 ENVIRONMENTAL SCIENCES↗

A Graphics Processing Unit (GPU) Approach to Large Eddy Simulation (LES) for Transport and Contaminant Dispersion

Recent advances in the development of large eddy simulation (LES) atmospheric models with corresponding atmospheric transport and dispersion (AT&D) modeling capabilities have made it possible to simulate short, time-averaged, single realizations of pollutant dispersion at the spatial and temporal resolution necessary for common atmospheric dispersion needs, such as designing air sampling networks, assessing pollutant sensor system performance, and characterizing the impact of airborne materials on human health. The high computational burden required to form an ensemble of single-realization dispersion solutions using an LES and coupled AT&D model has, until recently, limited its use to a few proof-of-concept studies. An example of an LES model that can meet the temporal and spatial resolution and computational requirements of these applications is the joint outdoor-indoor urban large eddy simulation (JOULES). A key enabling element within JOULES is the computationally efficient graphics processing unit (GPU)-based LES, which is on the order of 150 times faster than if the LES contaminant dispersion simulations were executed on a central processing unit (CPU) computing platform. JOULES is capable of resolving the turbulence components at a suitable scale for both open terrain and urban landscapes, e.g., owing to varying environmental conditions and a diverse building topology. In this paper, we describe the JOULES modeling system, prior efforts to validate the accuracy of its meteorological simulations, and current results from an evaluation that uses ensembles of dispersion solutions for unstable, neutral, and stable static stability conditions in an open terrain environment.

54 ENVIRONMENTAL SCIENCES↗

GRUMDN: A Multi-Task Model for Predicting Human Patterns-of-Life from Stay Transition Data

Understanding human patterns-of-life (PoL) is essential towards ensuring safe and secure indoor facility environment as well as outdoor urban environment. Prediction of human movement in between places of interest is vital in understanding human PoL. Movement between spaces maybe represented and detected in one of the two forms: 1) trajectories: locations measured at regular time intervals by mobile sensors, bluetooth or GPS sensors; or 2) stay transitions: semantic PoI (points of interest) and stay duration data measurable by eventbased sensors that collect data when a check-in or check-out event is detected. Stay transition data provides a more compressed data format compared to trajectories data, especially in situations with longer stay durations, while preserving the information necessary for PoL analysis. Now as introduced briefly in the paper, our deployed end application (Digital Twin of a facility with non-player characters, besides the interactive user in virtual reality) needed a well-performing and validated AI/ML model for simulating high quality stay transitions behavior. In this study we thus primarily present our findings with developing and validating that model, which is a multi-task neural network for stay transition prediction. The neural network consists of two heads, for corresponding two tasks of stay category prediction and stay duration prediction. We evaluated gated recurrent units and multi-layer perceptrons of varying network sizes for stay category prediction; while mixture density networks, noisy generator-only networks, and generative adversarial networks of varying network sizes for stay duration prediction. We have then evaluated four multi-task models, constructed by combining these specialized models, on their ability to predict stay transition data. We tested our models on datasets from two different cases: 1) a simulation-generated dataset of indoor movement within the HFIR (high flux isotope reactor) nuclear reactor facility at Oak Ridge National Laboratory (ORNL); and 2) the GeoLife human mobility dataset of outdoor urban movement available in literature. Our results indicate that GRUMDN, which combines gated recurrent units (GRU) for stay category prediction task, and mixture density networks (MDN) for stay duration prediction task, did overall outperform other multitask models and the current state-of-the-art.

Gunaratne, Chathika [ORNL] (ORCID:0000000225088745↗

Envelope-driven comfort risk in residential demand response

Residential demand response (DR) is a valuable resource for grid reliability, but remains challenging because the highly heterogeneous residential building stock leads to widely varying and hard-to-predict load and comfort responses during DR events. Although prior research has estimated the technical potential of DR-capable technologies for achieving energy demand savings, little is known about how they affect thermal comfort. In particular, it remains unclear how indoor thermal conditions due to DR depend on the thermal envelope characteristics of the housing stock. To address this gap, this study provides a systematic, location-specific assessment of indoor thermal performance during DR-events across the US housing stock using both typical DR weather data and detailed building metadata. We evaluate how envelope characteristics influence indoor temperatures during realistic simulated summer and winter DR events across 37 US locations, applying both temperature threshold and rate of temperature change criteria to estimate region-level probabilities of discomfort. Additionally, we show the impact of distinct weather patterns that intensify or abate thermal stress on comfort outcomes. Results show a near-universal overheating risk in summer DR events, where comfort outcomes are strongly influenced by rapid risk of comfort violations. In contrast, overall winter DR discomfort risk is lower, risk escalation is more gradual and shows greater sensitivity to event duration. These findings offer a data-driven quantification of comfort risk across diverse climates and building envelopes, demonstrating the need for region-specific DR scheduling and discomfort mitigation strategies tailored to local weather patterns and the performance of existing residential buildings.

Demand response↗

Defining weather scenarios for simulation-based assessment of thermal resilience of buildings under current and future climates: A case study in Brazil

In response to increasingly severe weather conditions, optimization of building performance and investment provides an opportunity to consider co-benefits of thermal resilience during energy efficiency retrofits. This work aims to assess thermal resilience of buildings using building performance simulation to evaluate the indoor overheating risk under nine weather scenarios, considering historical (2010s), mid-term future (2050s), and long-term future (2090s) typical meteorological years, and heat wave years. Such an analysis is based on resilience profiles that combine six integrated indicators. A case study with a district of 92 buildings in Brazil was conducted, and a combination of strategies to improve thermal resilience was identified. Results reflect the necessity of planning for resilience in the context of climate change. This is because strategies recommended under current conditions might not be ideal in the future. Therefore, an adaptable design should be prioritized. Cooling energy consumption could increase by 48 % by the 2050s, while excessive overheating issues could reach 37 % of the buildings. Simple passive strategies can significantly reduce the heat stress. A comprehensive thermal resilience analysis should ultimately be accompanied by a thorough reflection on the stakeholders’ objectives, available resources, and planning horizon, as well as the risks assumed for not being resilient.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A building performance-based approach to determining energy resilience for grocery stores in the event of a power outage

Evaluating progress toward a built environment that is best equipped to serve communities during a regional power outage will require metrics that capture the energy resilience of the unique buildings and businesses most crucial to the well-being of those nearby. We focused on grocery stores as key buildings for which access, and thus energy resilience, is critical during a disaster when power is unavailable. We evaluated the energy resilience of these buildings by offering and testing building-scale metrics that assess business continuity potential during a power outage. Metrics proposed in this study are calculated based on the unique power loads characteristic to grocery stores, primarily refrigeration and maintaining safe indoor environmental conditions. Building simulations based on varying levels of backup power were carried out against occupant safety and comfort parameters to apply these metrics, with additional criteria imposed on grocery stores to capture the inventory and sales loss from food spoilage resulting from a lack of refrigeration power. Findings from this study demonstrate the feasibility of our proposed metrics and methodology to serve as a low-data burden means for stakeholders to evaluate the energy resilience of grocery stores, with greater implications in helping to understand the impact on community-scale energy resilience.

Siegel, Lino Sanchez↗

Performance correlations of five solar collectors tested simultaneously outdoors

Collector thermal efficiency, and efficiency degradation with time were measured for 5 flat-plate solar collectors tested simultaneously in an outdoor solar collector test facility. Results indicate that by using collector performance parameters which account for diffuse isolation, outdoor data recorded on cloud days can be used as a measure of performance, as long as the ratio of direct to total insolation exceeds approximately 0.6. These outdoor results also show good agreement with thermal efficiency data obtained indoors in a solar simulator. Significant efficiency degradation occurred on only one of the five collectors exposed to outdoor conditions for a period of one to two years.

Miller, D. R.↗

Performance correlations of five solar collectors tested simultaneously outdoors

Collector thermal efficiency, and efficiency degradation with time were measured for 5 flat-plate solar collectors tested simultaneously in an outdoor solar collector test facility. Results indicate that by using collector performance parameters which account for diffuse insolation, outdoor data recorded on 'cloudy' days can be used as a measure of performance, as long as the ratio of direct to total insolation exceeds approximately 0.6. These outdoor results also show good agreement with thermal efficiency data obtained indoors in a solar simulator. Significant efficiency degradation occurred on only one of the five collectors exposed to outdoor conditions for a period of one to two years.

Miller, D. R.↗

Indoor tests of a hot-air solar collector

Data taken relating indoor testing using solar simulator at Marshall Space Center has been compared with data taken during outdoor tests in previous studies. Data includes tests on thermal performance, time constance, and incidence-angle modifier tests in table/graph form.

Source record↗

GE underwater test facility studies in zero G simulation

The underwater test facility (UTF) is described as an indoor controlled environment test facility designed specifically for zero G simulation, hydrospace manned and unmanned equipment development, and personnel training for both space and underwater exploration. Programs conducted in the UTF include: human engineering criteria for maintenance and repairs of space stations, astronaut performance, helmet distortion, underwater telemetry, and blood transfusion.

Fry, R. H.↗

Sensitivity Analysis of Drivers Water Shortage in the Los Angeles Region During Drought

The code and detailed step-by-step instructions for generating the model output data, processing results, and analysis and plotting are provided at https://github.com/IMMM-SFA/Ferencz_et_al_2026_ER_Water. The PyArtes model is a python adaptation of the Artes model. PyArtes uses many of the same input data and optimization model architecture as Artes. Documentation for the PyArtes model is provided in the Supplement to the paper. The primary data product are simulated monthly water shortages for indoor and outdoor demand under a large ensemble of drought scenarios (>13,000). The droughts are hypothetical and are not based on historical time series data of supply sources - though historical data did help inform ranges explored for supply parameters. Demands are informed by recent 2017-2021 water supply data. Demands used for the model can be accessed at https://github.com/IMMM-SFA/Ferencz_et_al_2026_ER_Water. Simulations resolve demand for over 90 water providers in the study region. The results report 36 months of water shortage data for each indoor and outdoor demand node. The study also developed a multilayer perceptron (MLP) neural network trained on a subset of the simulated shortage ensemble to emulate worst annual water shortage for a given set of parameter multipliers -- provided the parameter values fall within the ranges sampled in the ensemble. Emulated water shortages for synthetic ensembles are in the MLP-generated shortages folder. The MLP model was used to generate larger ensembles to support Sobol analysis that would have been extremely computationally expensive to simulate. Datasets provided in this repository*: Simulated shortages. These results are used for the analysis for Figures 5, 8, and 9 in the paper, and also to train the MLP emulator. .zip file containing outputs for the 13,312 scenario ensemble. Separate .csv files for indoor and outdoor shortage for each scenario. Rows = demand ids (~100), Columns = months (36) Units = acre-feet/month of shortage (shortage = monthly demand - supply). 1 acft = 1233.48 m^3 .csv files of aggregated shortages derived from the 13,312 ensemble Rows = scenarios (13,312), Columns = demand ids (~100) Units = acre-feet/year (either worst annual shortage or total shortage over the 3-year drought) .csv file of the parameter multipliers scenarios for the ensemble .csv file of the parameter ranges and baseline values the multipliers were applied to MLP-generated shortages. These results are used for Figures 4, 6, and 7 in the paper. mwd higher folder: scenario ensembles, emulated worst year total shortages (acft), and Sobol results Emulated shortages. Rows = scenarios, columns = demand ids, units acft Sobol results. Rows = demand ids, columns Sobol (S1, ST, or 95% confidence interval) value for each parameter mwd lower folder: scenario ensembles, emulated worst year total shortages (acft), and Sobol results same organization as mwd higher MLP performance: performance metrics (R^2, RMSE, BIAS, MAPE) for the testing subset (20% or 2,662 scenarios) and simulated vs emulated worst year shortage (acre-feet/year) for every demand node, MWD wholesale regions, and the entire study region (LAC). Supporting data for figures. Figure plotting scripts in the associated GitHub repo. These files support analysis and visualization. Geospatial Data used for plotting simulated water shortages and Sobol results. Dictionary of full names for demand nodes in the model and estimates of water supply by source type informed by Artes input files and California Urban Water Management Planning data: https://water.ca.gov/Programs/Water-Use-And-Efficiency/Urban-Water-Use-Efficiency/Urban-Water-Management-Plans *Readme files provided for each folder.

drought↗

Comprehensive Analysis of Model Parameter Uncertainty Influence on Evaluation of HVAC Operation to Mitigate Indoor Virus: A Case Study for an Office Building in a Cold and Dry Climate

Simulation-based studies of HVAC operation to mitigate indoor virus have been conducted to understand tradeoffs between indoor air quality (IAQ) and energy consumption. However, the influence of model parameter uncertainty in these studies has not been systematically quantified, which is critical when providing guidance to building operators. To address this gap, we identify 20 model parameters for a typical medium office building system in a cold and dry climate that can influence IAQ and energy consumption for indoor virus scenarios. Next, the distributions of the parameter values are estimated from literature and a set of simulation samples for three representative days is generated that simultaneously sample all of the parameters from their distributions. Two HVAC virus mitigation strategies are studied: increased filtration using MERV 13 filters and increased ventilation, via supply of 100% outdoor air into buildings. The model parameter uncertainty leads to significant variability in the results, particularly for the IAQ because of the highly uncertain virus generation rate. Use of 100% outdoor air can be beneficial for some uncertain scenarios on the hot day, but shows less IAQ improvement and/or significant energy increases on the other days. The virus removal efficiency and pressure drop of the HVAC filter, fan efficiency, and internal heat gain are the most important parameters to determining the tradeoffs of the two strategies. Our results demonstrate how this model parameter uncertainty analysis methodology can provide practical guidance to building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Study in a New Test Facility on Indoor Annoyance Caused by Sonic Booms

A sonic-boom simulator at NASA Langley Research Center has been constructed to research the indoor human response to low-amplitude sonic booms. The research goal is the development of a psychoacoustic model for individual sonic booms to be validated by future community studies. The study in this report assessed the suitability of existing noise metrics for predicting indoor human annoyance. The test signals included a wide range of synthesized and recorded sonic-boom waveforms. Results indicated that no noise metric predicts indoor annoyance to sonic-boom sounds better than Perceived Level, PL. During the study it became apparent that structural vibrations induced by the test signals were contributing to annoyance, so the relationship between sound and vibration at levels of equivalent annoyance has been quantified.

Rathsam, Jonathan↗

Driving a car with custom-designed fuzzy inferencing VLSI chips and boards

Vehicle control in a-priori unknown, unpredictable, and dynamic environments requires many calculational and reasoning schemes to operate on the basis of very imprecise, incomplete, or unreliable data. For such systems, in which all the uncertainties can not be engineered away, approximate reasoning may provide an alternative to the complexity and computational requirements of conventional uncertainty analysis and propagation techniques. Two types of computer boards including custom-designed VLSI chips were developed to add a fuzzy inferencing capability to real-time control systems. All inferencing rules on a chip are processed in parallel, allowing execution of the entire rule base in about 30 microseconds, and therefore, making control of 'reflex-type' of motions envisionable. The use of these boards and the approach using superposition of elemental sensor-based behaviors for the development of qualitative reasoning schemes emulating human-like navigation in a-priori unknown environments are first discussed. Then how the human-like navigation scheme implemented on one of the qualitative inferencing boards was installed on a test-bed platform to investigate two control modes for driving a car in a-priori unknown environments on the basis of sparse and imprecise sensor data is described. In the first mode, the car navigates fully autonomously, while in the second mode, the system acts as a driver's aid providing the driver with linguistic (fuzzy) commands to turn left or right and speed up or slow down depending on the obstacles perceived by the sensors. Experiments with both modes of control are described in which the system uses only three acoustic range (sonar) sensor channels to perceive the environment. Simulation results as well as indoors and outdoors experiments are presented and discussed to illustrate the feasibility and robustness of autonomous navigation and/or safety enhancing driver's aid using the new fuzzy inferencing hardware system and some human-like reasoning schemes which may include as little as six elemental behaviors embodied in fourteen qualitative rules.

Pin, Francois G.↗