Search NASA⌕ Search

SEARCH · Search NASA

Results for “Infrared optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The optical–infrared extinction curve and its variation in the Milky Way

The dust extinction curve is a critical component of many observational programs and an important diagnostic of the physics of the interstellar medium. Here we present new measurements of the dust extinction curve and its variation toward tens of thousands of stars, a hundred-fold larger sample than in existing detailed studies. We use data from the APOGEE spectroscopic survey in combination with ten-band photometry from Pan-STARRS1, the Two Micron All-Sky Survey, and Wide-field Infrared Survey Explorer. We find that the extinction curve in the optical through infrared is well characterized by a one-parameter family of curves described by R(V). The extinction curve is more uniform than suggested in past works, with σ(R(V))=0.18, and with less than one percent of sight lines having R(V)>4. Our data and analysis have revealed two new aspects of Galactic extinction: first, we find significant, wide-area variations in R(V) throughout the Galactic plane. These variations are on scales much larger than individual molecular clouds, indicating that R(V) variations must trace much more than just grain growth in dense molecular environments. Indeed, we find no correlation between R(V) and dust column density up to E(B−V)≈2. Second, we discover a strong relationship between R(V) and the far-infrared dust emissivity.

79 ASTRONOMY AND ASTROPHYSICS↗

Acousto-optic infrared spectral imager for Pluto fast flyby

Acousto-optic tunable filters (AOTF's) enable the design of compact, two-dimensional imaging spectrometers with high spectral and spatial resolution and with no moving parts. Tellurium dioxide AOTF's operate from about 400 nm to nearly 5 microns, and a single device will tune continuously over one octave by changing the RF acoustic frequency applied to the device. An infrared (1.2-2.5 micron) Acousto-Optic Imaging Spectrometer (AImS) was designed that closely conforms to the surface composition mapping objectives of the Pluto Fast Flyby. It features a 75-cm focal length telescope, infrared AOTF, and 256 x 256 NICMOS-3 focal plane array for acquiring narrowband images with a spectral resolving power (lambda/delta(lambda)) exceeding 250. We summarize the instrument design features and its expected performance at the Pluto-Charon encounter.

Glenar, D. A.↗

AGNs in post-mergers from the ultraviolet near infrared optical northern survey

The kinematic disturbances associated with major galaxy mergers are known to produce gas inflows, which in turn may trigger accretion onto the supermassive black holes (SMBH) of the participant galaxies. While this effect has been studied in galaxy pairs, the frequency of active galactic nuclei (AGNs) in fully coalesced post-merger systems is poorly constrained due to the limited size or impurity of extant post-merger samples. Previously, we combined convolutional neural network (CNN) predictions with visual classifications to identify a highly pure sample of 699 post-mergers in deep r-band imaging. In the work presented here, we quantify the frequency of AGNs in this sample using three metrics: optical emission lines, mid-infrared (mid-IR) colour, and radio detection of low-excitation radio galaxies (LERGs). We also compare the frequency of AGNs in post-mergers to that in a sample of spectroscopically identified galaxy pairs. We find that AGNs identified by narrow-line optical emission and mid-IR colour have an increased incidence rate in post-mergers, with excesses of ~4 over mass- and redshift-matched controls. The optical and mid-IR AGN excesses in post-mergers exceed the values found for galaxy pairs, indicating that AGN activity in mergers peaks after coalescence. Conversely, we recover no significant excess of LERGs in post-mergers or pairs. Finally, we find that the [O III ] luminosity (a proxy for SMBH accretion rate) in post-mergers that host an optical AGN is ~0.3 dex higher on average than in non-interacting galaxies with an optical AGN, suggesting that mergers generate higher accretion rates than secular triggering mechanisms.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison Between Infrared Optical and Stereoscopic X-Ray Technologies for Patient Setup in Image Guided Stereotactic Radiotherapy

Purpose: To compare infrared (IR) optical vs. stereoscopic X-ray technologies for patient setup in image-guided stereotactic radiotherapy. Methods and Materials: Retrospective data analysis of 233 fractions in 127 patients treated with hypofractionated stereotactic radiotherapy was performed. Patient setup at the linear accelerator was carried out by means of combined IR optical localization and stereoscopic X-ray image fusion in 6 degrees of freedom (6D). Data were analyzed to evaluate the geometric and dosimetric discrepancy between the two patient setup strategies. Results: Differences between IR optical localization and 6D X-ray image fusion parameters were on average within the expected localization accuracy, as limited by CT image resolution (3 mm). A disagreement between the two systems below 1 mm in all directions was measured in patients treated for cranial tumors. In extracranial sites, larger discrepancies and higher variability were observed as a function of the initial patient alignment. The compensation of IR-detected rotational errors resulted in a significantly improved agreement with 6D X-ray image fusion. On the basis of the bony anatomy registrations, the measured differences were found not to be sensitive to patient breathing. The related dosimetric analysis showed that IR-based patient setup caused limited variations in three cases, with 7% maximum dose reduction in the clinical target volume and no dose increase in organs at risk. Conclusions: In conclusion, patient setup driven by IR external surrogates localization in 6D featured comparable accuracy with respect to procedures based on stereoscopic X-ray imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Infrared Optical Anisotropy in Quasi‐1D Hexagonal Chalcogenide BaTiSe 3

Polarimetric infrared (IR) detection bolsters IR thermography by leveraging the polarization of light. Optical anisotropy, i.e., birefringence and dichroism, can be leveraged to achieve polarimetric detection. Recently, giant optical anisotropy is discovered in quasi-1D narrow-bandgap hexagonal perovskite sulfides, A 1+x TiS 3 , specifically BaTiS 3 and Sr 9/8 TiS 3 . In these materials, the critical role of atomic-scale structure modulations in the unconventional electrical, optical, and thermal properties raises the broader question of the nature of other materials that belong to this family. To address this issue, for the first time, high-quality single crystals of a largely unexplored member of the A 1+x TiX 3 (X = S, Se) family, BaTiSe 3 are synthesized. Single-crystal X-ray diffraction determined the room-temperature structure with the P31c space group, which is a superstructure of the earlier reported P6 3 /mmc structure. The crystal structure of BaTiSe 3 features antiparallel c-axis displacements similar to but of lower symmetry than BaTiS 3 , verified by the polarization dependent Raman spectroscopy. Fourier transform infrared (FTIR) spectroscopy is used to characterize the optical anisotropy of BaTiSe 3 , whose refractive index along the ordinary (E ⊥ c) and extraordinary (E ‖ c) optical axes is quantitatively determined by combining ellipsometry studies with FTIR. With a giant birefringence Δn ∼ 0.9, BaTiSe 3 emerges as a new candidate for miniaturized birefringent optics for mid-wave infrared to long-wave infrared imaging.

optical anisotropy↗

A determination of the infrared optical depth of the El Chichon volcanic cloud

Infrared transmission spectra of the atmosphere above 11-km altitude were obtained in December 1982 and April/May 1983 from a NASA Convair 990 aircraft. The observations on the first flight series encompassed low and middle latitudes in the Northern Hemisphere, while the observations on the second series covered a wide range of latitudes in both hemispheres. These data have been analyzed to derive the optical depth of the El Chichon volcanic cloud at a wavelength of 8.4 microns. These data imply that concentrated sulfuric acid was the dominant source of aerosol extinction in the 8- to 12-microns window region of the earth's atmosphere and that the volume modal particle radius equalled 0.6 + or - 0.1 mu at the time of the observations. At these times, the volcanic particles produced a significant warming of the lower stratosphere and had a nontrivial impact on the radiation budget of the troposphere and ground in the Northern Hemisphere.

Pollack, James B.↗

TEMPERATURE-DEPENDENT INFRARED OPTICAL CONSTANTS OF OLIVINE AND ENSTATITE

Since the Infrared Space Observatory (ISO) mission, it has become clear that dust in circumstellar disks and outflows consists partly of crystalline silicates of pyroxene and olivine type. An exact mineralogical analysis of the dust infrared emission spectra relies on laboratory spectra, which, however, have been mostly measured at room temperature so far. Given that infrared spectral features depend on the thermal excitation of the crystal's vibrational modes, laboratory spectra measured at various (low and high) temperatures, corresponding to the thermal conditions at different distances from the star, can improve the accuracy of such analyses considerably. We have measured the complex refractive index in a temperature range of 10-973 K for one mineral of each of those types of silicate, i.e., for an olivine and an enstatite of typical (terrestrial) composition. Thus, our data extend the temperature range of previous data to higher values and the compositional range to higher iron contents. We analyze the temperature dependence of oscillator frequencies and damping parameters governing the spectral characteristics of the bands and calculate absorption cross-sectional spectra that can be compared with astronomical emission spectra. We demonstrate the usefulness of our new data by comparing spectra calculated for a 100 K dust temperature with the ISO SWS spectrum of IRAS 09425-6040.

79 ASTRONOMY AND ASTROPHYSICS↗

A catalog of small, optically selected molecular clouds - Optical, infrared, and millimeter properties

A catalog of small, optically selected molecular clouds is presented. The relevant selection criteria were small angular size, large central opacity, and freedom from connecting opaque material. The mean ellipticity of the clouds in the catalog is 2.0, with a maximum ellipticity of 7. The position angle of the clouds is uncorrelated with the direction of the Galactic plane. About 60 percent of the cataloged clouds have associated IRAS Point Source Catalog (PSC) sources in their cores or envelopes. The likelihood of a detection of a PSC source is some 6.1 times higher for the core regions of the clouds than for the envelopes, indicating a strong association of FIR sources and Bok globules. Of a sample of 97 of the clouds observed in the J = 2-1 line of (C-12)O, 70 percent have cold gas kinetic temperatures and approximately sonic line widths. The remaining 30 percent are about equally divided between those clouds likely to be radiatively heated by nearby stars and those undergoing active protostellar collapse or outflows with no bulk gas heating.

Clemens, Dan P.↗

Impact of Infrared Optical Properties on Crystalline Si and Thin Film CdTe Solar Cells

Photons with energies below the photovoltaic (PV) absorber band gap do not generate current and adversely impact performance when absorbed in other solar cell components to produce heat. Here we incorporate infrared (IR) optical response in simulations for understanding thermal losses. Spectroscopic ellipsometry is used to measure Al-Si interface optical properties in Si PV. Reflectance of an Si module has been analyzed to account for encapsulant and Al-Si interface contributions. IR extended quantum efficiency simulations calculate efficiency gains / losses arising from variations in current generated and total reflectance as functions of transparent front contact material in thin film CdTe PV.

14 SOLAR ENERGY↗

Infrared Optical Constants from Pressed Pellets of Powders: I. Improved n and k Values of (NH4)(2)SO(4)from Single-Angle Reflectance

In combination with other parameters, the real, n(?), and imaginary, k(?), components of the complex refractive index, = n + ik, can be used to simulate the optical properties of a material in different forms, e.g. its infrared spectra. But obtaining reliable values of the optical constants n/k for solid materials is challenging due to the lack of optical quality specimens, usually crystals, large enough to measure. An alternative to crystals is to press the powder into a uniform disk. We have produced pellets from ammonium sulfate, (NH4)2SO4, powder and derived the pellets’ n and k values via single-angle reflectance using a specular reflectance device in combination with a Fourier transform infrared spectrometer. The single-angle technique measures amplitude of light reflected from the material as a function of wavelength over a wide spectral domain; the optical constants are determined from the reflectance data using the Kramers-Kronig relationship. We investigate several parameters associated with the pellets and pellet formation and their effects upon delivering the most reliable n/k values. Parameters studied include pellet diameter, mass and density (void space), drying, grinding, sieving and particle size in the pellet formation, as well as pressing pressure and duration. Of these parameters, using size-selected mixtures of dried, small (< 100 µm) particles and pressing at = 10 tons for at least 30 minutes were found key to forming highly reflective samples. Comparison to two sets of previous literature n(?) and k(?) values obtained from crystalline (NH4)2SO4 both as crystal reflectance as well as extinction spectra of aerosols measured in a flow tube show reasonable agreement, but suggests the present values, as confirmed from two independent techniques, represent a substantial improvement for n/k values for (NH4)2SO4, also demonstrating promise to measure the optical constants of other materials.

Optical constants, index of refraction, single-ang↗

Study of SRM Critical Surfaces Using Near Infrared Optical Fiber Spectrometry

The measurement and control of cleanliness for critical surfaces during manufacturing and in service operations provides a unique challenge in the current thrust for environmentally benign processes. Of particular interest has been work performed in maintaining quality in the production of bondline surfaces in propulsion systems and the identification of possible contaminants which are detrimental to the integrity of the bondline. This work requires an in-depth study of the possible sources of contamination, methodologies to identify contaminants, discrimination between contaminants and chemical species caused by environment, and the effect of particular contaminants on the bondline integrity of the critical surfaces. This paper will provide an introduction to the use of Near Infrared (NIR) optical fiber spectrometry in a nondestructive measurement system for process monitoring and how it can be used to help clarify issues concerning surface chemistry. In a previous conference, experimental results for quantitative measurement of silicone and Conoco HD2 greases, and tape residues on solid rocket motor surfaces were presented. This paper will present data for metal hydroxides and discuss the use of the integrating sphere to minimize the effects of physical properties of the surfaces (such as surface roughness) on the results obtained from the chemometric methods used for quantitative analysis.

Workman, G. L.↗

Using JWST Heritage to Enable a Future Large Ultra-Violet Optical Infrared Telescope

To the extent it makes sense, leverage JWST knowledge, designs, architectures, GSE. Develop a scalable design reference mission (9.2 meter). Do just enough work to understand launch break points in aperture size. Demonstrate 10 pm stability is achievable on a design reference mission. Make design compatible with starshades. While segmented coronagraphs with high throughput and large bandpasses are important, make the system serviceable so you can evolve the instruments. Keep it room temperature to minimize the costs associated with cryo. Focus resources on the contrast problem. Start with the architecture and connect it to the technology needs.

JWST UV Optical Infrared↗

The Infrared-Optical Telescope (IRT) of the Exist Observatory

The IRT is a 1.1m visible and infrared passively cooled telescope, which can locate, identify and obtain spectra of GRB afterglows at redshifts up to z 20. It will also acquire optical-IR, imaging and spectroscopy of AGN and transients discovered by the EXIST (The Energetic X-ray Imaging Survey Telescope). The IRT imaging and spectroscopic capabilities cover a broad spectral range from 0.32.2m in four bands. The identical fields of view in the four instrument bands are each split in three subfields: imaging, objective prism slitless for the field and objective prism single object slit low resolution spectroscopy, and high resolution long slit on single object. This allows the instrument, to do simultaneous broadband photometry or spectroscopy of the same object over the full spectral range, thus greatly improving the efficiency of the observatory and its detection limits. A prompt follow up (within three minutes) of the transient discovered by the EXIST makes IRT a unique tool for detection and study of these events, which is particularly valuable at wavelengths unavailable to the ground based observatories.

Kutyrev, Alexander↗

Measurement of the infrared optical constants for spectral modeling: n and k values for (NH4)2SO4 via single-angle reflectance and ellipsometric methods

The optical constants n and k can be used to model infrared spectra, including refraction, absorption, reflectance, and emissivity, but obtaining reliable values for solid materials (pure or otherwise) presents a challenge: In the past, the best results for n and k have been obtained from bulk, homogeneous materials, free of defects. That is, materials where the Fresnel equations are operant since there is no light scattering. Since it is often not possible to obtain a pure macroscopic (crystalline) material, it may be possible to press the material into a (uniform, void-free) disk. We have recently been able to do this with ammonium sulfate powder and then measured the n & k values via two independent methods: 1) Ellipsometry - which measures the changes in amplitude and phase of light reflected from the material of interest as a function of wavelength and angle of incidence, and 2) Single angle specular reflectance with an FT spectrometer using a specular reflectance device within an FT instrument which measures the change in amplitude of light reflected from the material of interest as a function of wavelength and angle of incidence over a wide wavelength range. The quality of the derived n & k values was tested by generating the reflectance spectra of the pellet and comparing to the calculated to measured reflectance spectra of the pure material which has been previously published. The comparison to literature values showed good accuracy and good agreement, indicating promise to measure other materials by such methods.

ammonium sulfate↗

The Thermal Infrared Optical Depth of Mineral Dust Retrieved from Integrated CALIOP and IIR Observations

Recent studies reveal that a higher fraction of coarse mineral dust particles than that estimated by climate model simulations has been observed in the atmosphere, leading to a more significant positive (i.e., warming) longwave (LW) thermal infrared (TIR) direct radiative effect (DRE). However, the magnitude of this DRE remains highly uncertain because our understanding of the radiative properties, quantitatively represented by the optical depth of dust, especially information on the TIR, remains limited. This study presents a simple approach to retrieve the thermal infrared dust aerosol optical depth (DAODTIR) over oceans during nighttime using the observations from the Infrared Imaging Radiometer (IIR) and the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) onboard CALIPSO. For each cloud-free dust-laden profile identified by the IIR-CALIOP observation, a Lookup-Table (LUT) of the 10.6 μm IIR band brightness temperatures difference (dBT) under different DAODTIR with respect to their dust-free BTs is constructed based on the CALIOP retrieved dust vertical profile and pre-assumed dust scattering properties using a fast radiative transfer model. Then the DAODTIR is retrieved by projecting the IIR-observed dBT on the LUT. Sensitivity studies show that the DAODTIR retrieval at 10.6 μm is more susceptible to the dust particle size distribution (PSD) assumption than dust refractive indices. To estimate the uncertainty caused by PSD assumption, two DAODTIR retrieval products, one based on the dust PSD from the AERONET at Cape Verde and the other on an in situ measured PSD from the recent Fennec campaign, are provided. The retrieval uncertainty is mainly contributed by the BT difference between the observation and simulation using auxiliary atmospheric data. The climatology of the retrieval from 2013 to 2019 shows confident spatiotemporal variations of DAODTIR with the global-averaged value of 0.006 and 0.008 based on different pre-assumed dust PSDs. Climatological results agree reasonably well with two independent DAODTIR retrieval products based on the Infrared Atmospheric Sounding Interferometer (IASI) over the active dust transport regions, such as North and Tropical Atlantic (r = 0.904 and 0.819) and Indian Ocean (r = 0.832). The seasonal and interannual variation is also well-compared (r = 0.758) with AERONET coarse-mode AOD at 97 selected sites. The synergic CALIOP observation allows the retrieved DAODTIR to directly compare with the extrapolated DAODTIR from DAOD in visible (i.e., 532 nm), which helps evaluate the observational constraints on DAODTIR. This study offers a unique prospect of collocating active lidar and passive IR observations for retrieving dust DAODTIR.

aerosol↗

Improved Infrared Optical Constants from Pressed Pellets: II. Ellipsometric n and k Values for Ammonium Sulfate with Variability Analysis

Infrared spectral imaging is facilitated via the comparison of spectra recorded in situ to a databank of actual or synthetic infrared reflectance spectra. It has recently been shown that reference spectra corresponding to the many different morphological forms of the same chemical can be generated synthetically using the imaginary, k, and real, n, components of the complex refractive index, n~ = n + ik. One method to obtain the n and k vectors is infrared ellipsometry, which measures the changes in amplitude, tan ?, and phase, ?, of polarized light reflected from the sample both as a function of wavenumber and angle of incidence. The method requires specularly reflected light so best results are usually obtained with polished planar samples of large surface area. Due to the difficulties of obtaining such samples, however, we investigate the possibility of pressing powders of neat materials and obtaining the corresponding optical constants from the pellets. In this paper, variability in the sample pellet and preparation method is investigated, as is variability in the fitting procedure for the derived optical constants. The n/k vectors are derived from the measured ellipsometric parameters, tan ? and ?, as they are fit by an oscillator model which yield n(?) and k(?) vectors as a function of wavenumber, ?. Construction of the oscillator model is not automatic and depends on significant input from the analyst as well as the sample’s physical characteristics. For the pellet pressing, the experimental variability was found to be minimized for size-selected powdered samples as gauged by the minimal variance in ? and ? for three different pellets; similarly, the analytical precision for multiple measurements of the same pellet was also quite good, suggesting that a pressed pellet is a viable sample preparation method. The greatest variability came in the analytic fitting procedure with differences up to 20% arising from four different fits to the same data set. The final ellipsometric n/k data are compared to literature values obtained from crystalline (NH4)2SO4 samples as well as single-angle reflectance measurements that also used pressed pellets. Comparison with the previous literature values shows generally good agreement although higher k-values are observed for the independent sets of data derived from pressed pellets. These data are suggested as an improved set of optical constants for (NH4)2SO4.

optical constants, ellipsometry, ammonium sulfate,↗