Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inspection with neutrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Progress on Associate-Particle Imaging Algorithms, 2020

The present work describes progress on the development of imaging algorithms that use fast neutron signatures acquired using the associated-particle imaging (API) method. The present work complements ongoing work to develop neutron source and detector hardware to enable field inspection by investigating algorithms that are capable of discriminating between critical materials or extracting three-dimensional geometrical information from single-sided or transmission measurements. The present work is divided into three approaches:(1)Iterative reconstruction of inelastic gamma-ray emissions to perform three-dimensional time-of-flight imaging in a single view in either transmission or backscatter configurations. Iterative reconstruction enables image resolution better than the inherent TOF resolution.(2)Decomposition of registered neutron and x ray radiographs into an assumed material list for each pixel in the image.(3)Material identification using full spectral analysis that includes the emergent neutron and gamma ray energies, times, and angles.Progress for each approach is summarized for fiscal year 2020.

97 MATHEMATICS AND COMPUTING↗

Grating-Based Imaging-Scattering with Portable Neutron Generator

Company: Adelphi Technology, Inc. Title: Grating-Based Imaging-Scattering with Portable Neutron Generator PI: Dr. Jay Theodore Cremer, Jr. Topic: 26a Statement of the problem or situation that is being addressed. Successful plant growth depends upon an efficient and robust root system. The plant root is part of a larger system of water and microbial flows in the soil system. While much effort has been exerted to develop an imaging system for water, microbes, and roots, the problem is challenging, and no widely accepted imaging method currently exists. The optical solutions use a highly modified soil system. X-ray imaging methods are insensitive to the soft tissues in the presence of sand. Thermal neutron imaging has been often tested, but found inadequate, due to limited access and low image resolution. This project will develop a new strategy for neutron imaging of plant/soil systems. The project will allow long duration experiments in greenhouse environments and increase the image information content to the micron scale. General statement of how this problem is being addressed. Portable, rugged thermal and fast neutron sources are being developed where portable means a two-soldier team can carry the source and power unit to survey rough terrain for explosives. In the past decade, microfabrication of X-ray and thermal/cold neutron optics has opened a new imaging strategy. The standard transmission image is now supplemented with simultaneous acquisition of a phase contrast image and an image revealing scattering features. In materials science, the interferometric neutron scattering image has been used to detect early crack formation in stressed additive manufacturing test samples. The detection requires sensitivity to scattering features at the 1-micron scale. By addition of our proposed grating-optic to Adelphi Technology’s radiographic/tomographic imaging system, which is based on portable thermal neutron source, the resulting thermal neutron scatter image of the plant/soil system, will reveal details at 1-micron. Commercial Applications and Other Benefits Neutron interferometry imaging has greater penetration through large metal components compared to industrial X-ray imaging. The low-cost, large area optics developed for greenhouse applications, combined with the robust, portable neutron generator, can then be marketed as a system for inspection of additive manufactured components. In the aerospace industry, all freshly printed components are validated with X-ray CT. Scheduled maintenance again requires X-ray CT as the ability to predict aerospace component lifetime does not yet exist. Large aerospace components are only partially observed with X-ray imaging. Key Words Neutron radiography/tomography, grating interferometry, thermal neutron generator imaging, plant root and soil imaging, rhizosphere imaging, deployable neutron imaging systems Summary for Members of Congress A rugged, portable source of thermal neutrons is adapted for neutron interferometry imaging with the addition of low-cost, 3D printed optics. The first application of our proposed deployable, compact thermal neutron generator imaging system, using a grating optic, is plant root/soil science in greenhouse settings and agricultural laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Illustration of Neutronic Decoupling in Fresh Fuel Storage Environments [Slides]

Operations beyond static storage of fuel assemblies occur in SFPs (moving around the pool, inspection, etc.). These assemblies are assumed suitably distanced at 30 cm. When assemblies are separated by enough water, the neutrons from one cannot cause fission in another, which results in neutronic decoupling. This assumption was investigated for PWR and BWR assemblies as part of ORNL-TM/2021/2330.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IAEA Photonuclear Data Library 2019

Here, photo-induced reaction cross section data are of importance for a variety of current or emerging applications, such as radiation shielding design and radiation transport analyses, calculations of absorbed dose in the human body during radiotherapy, physics and technology of fission reactors (influence of photo-reactions on neutron balance) and fusion reactors (plasma diagnostics and shielding), activation analyses, safeguards and inspection technologies, nuclear waste transmutation, medical isotope production and astrophysical applications. To address these data needs the IAEA Photonuclear Data library was produced in 1999, containing evaluated photo-induced cross sections and neutron spectra for 164 nuclides which were deemed relevant for the applications. Since the release of the IAEA Photonuclear Data Library however, new experimental data as well as new methods to assess the reliability of experimental cross sections have become available. Theoretical models and input parameters used to evaluate photo-induced reactions have improved significantly over the years. In addition, new measurements of partial photoneutron cross sections using mono-energetic photon beams and advanced neutron detection systems have been performed allowing for the validation of the evaluations and assessments of the experimental data. Furthermore, technological advances have led to the construction of new and more powerful gamma-beam facilities, therefore new data needs are emerging. We report our coordinated efforts to address these data needs and present the results of the new up-to-date evaluations included in the new updated IAEA Photonuclear Data Library consisting of 219 nuclides. The new library includes 188 new evaluations produced by the CRP evaluators, and one evaluation taken from the JENDL/PD-2016 library, while 20 evaluations were retained from the previous 1999 IAEA Photonuclear Data Library. In most of the cases, the photon energy goes up to 200 MeV. A total of 55 nuclides are new in this library reflecting the progress in measurements but also the developing data needs. In this paper we discuss the new assessment method and make recommendations to the user community in cases where the experimental data are discrepant and the assessments disagree. In addition, in the absence of experimental data, we present model predictions for photo-induced reaction cross section on nuclides of potential interest to medical radioisotope production.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Boron-Based Neutron Scintillator Screen Characterization with X-Rays and Neutrons

Recent work on boron-based neutron scintillator screens suggests these screens can offer superior performance when compared to commonly used screens. Borated neutron scintillator screens perform well in terms of light output (5-6 times greater than a standard Gadox screen) and detection effi-ciency (larger than standard LiF+ZnS screens). However, previously manu-factured boron-based screens have exhibited non-uniform surface coating and a poor mixture between phosphor and converter particles. The objective of this work was to evaluate newly fabricated scintillator screens to deter-mine if enhanced fabrication methods produced a more homogeneous distribution between neutron converter and scintillation phosphor particles. Uniformity of scintillator material deposition was also inspected. This new iteration of screens appeared more uniform than previous generations with the new coating method improving surface chemistry and scintillator material homogeneity. Additionally, a new methodology for screen characterization, involving the correlation of a neutron image taken with a borated scintillator screen to X-ray computed tomography of that same screen, was demonstrated to elucidate a relationship between scintillator screen thickness and relative light output of the screen under neutron exposure. This method suggested that the ideal thickness of scintillator material was ~150 µm to maximize light output of the screen.

36 - MATERIALS SCIENCE↗

Delayed Critical and Subcritical Experiments with Polyethylene Moderated Unreflected Thin 15 in. Diameter HEU Metal Plates

The thin ~15 in. diameter highly enriched uranium (HEU) metal plates were assembled to delayed criticality at the Oak Ridge Critical Experiments Facility (ORCEF) in 1969 with various thicknesses of polyethylene (varying from 1/16 to 2$\frac{3}{8}$ inches) between uranium metal plates. The average 235 U enrichment was 93.27 wt. %. These unreflected critical configurations contained 4$\frac{2}{3}$ to 20$\frac{5}{6}$ thin 15 in. diameter HEU metal plates (on loan from Los Alamos National Laboratory [LANL] and shipped to Oak Ridge National Laboratory [ORNL] on June 3, 1969). Depending on the thickness of polyethylene, the enriched uranium masses varying from 28,053 to 135,148 grams. Fractional plate sections consisted of the appropriate number of 60° pie sections. In addition to the measurement at delayed criticality, subcritical measurements were also performed by the inverse kinetic rod drop method. Prompt neutron decay constant measurements were also performed by the Rossi alpha and randomly pulsed neutron method using a time-tagged spontaneous fission californium neutron source; these are briefly reported here. At the time of these measurements in 1969, the thin HEU metal plates were in near-pristine condition with extremely little oxidation, allowing better descriptions of the uranium plates than the use of these plates in a heavily oxidized and deteriorated condition in recent reflected benchmark experiments at the LANL facility at the Nevada Test Site with these same thin highly enriched uranium metal plates. This report documents the experimental information for the measurements performed so that later researchers can perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Evaluation Program (ICSBEP) or a Nuclear Energy Agency (NEA) benchmark. Data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program once the uncertainty analysis on the measured neutron multiplication factors is completed. Additional data—such as the dimensional inspection reports, uranium isotopic information, and other relevant particulars—should be retrieved from the Y-12 Plant or LANL and incorporated in the final ICSBEP benchmark. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in $k_{eff}$ could be as low as ± 0.0002 for some configurations. Other experiments with smaller-diameter than 15 in. diameter HEU metal plates have been benchmarked in HEU-METFAST-001. The prompt neutron time decay measurements could be the basis for an International Reactor Physics Benchmark Program. Preparation of the present report is part of an effort at ORNL to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other US Department of Energy critical experiments facilities using more than 500 operational days of critical facility time. This work for this report publication was supported by the Nuclear Criticality, Radiation Transport and Safety NCSP Program at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ceci N’est Pas Une Bombe: Lessons from a Field Experiment Using Neutron and Gamma Measurements to Confirm the Absence of Nuclear Weapons

In March 2023, the UN Institute for Disarmament Research held a verification experiment that included a mockup onsite inspection at a former military facility in the municipality of Menzingen, Switzerland. The experiment included a visit to the site by an inspection team, accompanied by the host team. Among other activities, radiation measurements were used to confirm the non-nuclear nature of selected items stored onsite. In this paper, we discuss the neutron and gamma measurement systems used during the experiment and the inspection protocols followed to confirm the absence of nuclear weapons. Furthermore, results from the experiment and a laboratory reproduction are presented, before concluding with lessons learned for how absence-confirmation measurements can help support verification of future arms control agreements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Fast-neutron/gamma-ray radiography using a broad-energy neutron source

Transmission radiography is a well-established nondestructive examination technique with widespread application to fields ranging from medicine to security. Traditionally, inspection is performed using a single particle type (such as x-rays). However, the information available using a single probe for traditional radiography is limited. The present work evaluates material discrimination via transmission radiography using the attenuation ratio of monoenergetic gamma rays to a broad spectrum of fast neutrons. Here, the method was assessed using an 241 Am/Be radioisotope source that provides both 4.4 MeV gamma rays and a spectrum of fast neutrons up to 12 MeV. A total of 14 object configurations were measured: seven different materials each with two thicknesses (2.5 cm and 5 cm). The ability to distinguish materials was evaluated and shows more significant variation among atomic numbers than for high-energy x-rays alone, making it easier to distinguish between classes such as low-, mid-, and high-Z materials. These results suggest that superior material discrimination is also possible using a combination of monoenergetic gamma rays and broad-spectrum fast neutrons from a variety of nuclear reactions, such as 11 B(d,nγ) 12 C, that could be implemented in future inspection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications and Deployment of Neutron Scatter Cameras in Nuclear Safeguards Scenarios

Neutron scatter cameras (NSCs) are a type of directionally sensitive neutron detector that rely on two consecutive neutron scattering events to localize a source of neutrons. NSCs can be used to locate, image, and identify unknown neutron sources or verify the geometry and identity of known sources. Much technical progress has been made in improving NSC designs, but little literature exists exploring the full range of practical application of neutron scatter cameras. This paper seeks to identify scenarios related to nuclear security and non-proliferation where deployment of NSCs may be useful. These situations could include: limited searches for sources during cargo screening, counting nuclear warheads for treaty verification, verification of special nuclear material during inspections, imaging nuclear contamination, imaging nuclear reactor cores, searching for lost sources, and matching neutron images in shipper/receiver or inventory management scenarios. These scenarios are examined with respect to existing NSC designs and proposed designs in terms of usefulness and practicality of deployment when compared to currently used detection systems.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Flash Neutron Imaging [Poster]

The NNSS has extensive historical experience with high-fidelity flash neutron imaging which may be applicable to the needs of NA-22. In recent neutron imaging tests, a dense plasma focus (DPF) discharges a capacitor bank across a hydrogen-filled diode to create a flash of fusion neutrons emitted from a point, which can be used for active interrogation. Object inspection may include both radiography transmission imaging as well as emission imaging of the subject via an aperture. A scintillator screen (coupled to a low-Z converter when necessary) converts deposited energy to visible light, which is relayed through optics to an ultra-sensitive visible imager contained in a light-tight box. Flash photon imaging, utilizing bremsstrahlung emission instead of fusion neutrons, is also available and is more mature.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Non-destructive evaluation and machine learning methods for inspection of spent nuclear fuel canisters: A state-of-the-art review

Nuclear energy is among the cleanest and most efficient energy sources currently available. The operation of nuclear power plants (NPPs) produces large amounts of high-level radioactive waste known as spent nuclear fuel (SNF). Currently, large amounts of SNF is stored in dry cask storage systems (DCSSs) for extended interim storage until a permanent disposal solution becomes available. During the extended interim storage, the DCSS, particularly the SNF canisters, may degrade and abnormal conditions may occur. Therefore, non-destructive evaluation (NDE) and machine learning (ML) approaches are necessary for inspection of SNF canisters. This paper presents a state-of-the-art review of literature by summarizing recent progress made on the applications of NDE and ML for inspection of SNF canisters. Sixteen NDE methods are examined and compared: visual inspection, ultrasonic guided waves (UGWs), laser-based approaches, acoustic emission (AE), eddy current testing (ECT), non-invasive acoustic sensing, dynamic modal testing, cosmic ray muons tomography, neutron imaging, gamma rays detection, fiber optical sensors, through-wall communications, X-ray computed tomography (CT), vibrothermography, monoenergetic photon sources, and surface acoustic wave (SAW) sensors. The technology readiness level (TRL) for each method is assessed and compared. Recent publications on ML-enhanced visual inspection, AE, non-invasive acoustic sensing, dynamic modal testing, and neutron imaging for SNF canisters are summarized and future research needs are identified. In conclusion, this review article provides a convenient reference on the state-of-the-art applications of NDE and ML methods for inspection of SNF canisters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feasibility study of a compact neutron resonance transmission analysis instrument

Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, enrichment analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in the intensity of compact neutron sources have made compact neutron imaging designs increasingly feasible. This work describes the Monte Carlo (MC) based design of a compact epithermal NRTA radiographic instrument which uses a moderated, compact deuterium-tritium (DT) neutron source and an epithermal neutron detector. Such an instrument would have a wide range of applications, and would be especially impactful for such scenarios as nuclear inspection and arms control verification exercises, where system complexity and mobility may be of critical importance. The MC simulations presented in this work demonstrate accurate time-of-flight (TOF) reconstructions for transmitted neutron energies, capable of differentiating isotopic compositions of nuclear material with high levels of accuracy. A new generation of miniaturized and increasingly more intense neutron sources will allow this technique to achieve measurements with greater precision and speed, with significant impact on a variety of engineering and societal problems.

47 OTHER INSTRUMENTATION↗

Quartz Ampoule Loading, Sealing, and Inspection

This procedure applies to the loading of materials into quartz ampoules and flame sealing these ampoules. Flame sealed quartz ampoules are commonly used as a sealed containment for neutron irradiation. Due to the importance of maintaining containment for this application, this procedure involves a double encapsulation design wherein a sealed inner ampoule is sealed is in turn sealed within a larger diameter outer ampoule. General guidance for inspection of ampoules by destructive, non-destructive, qualitative (e.g., visual) and other methods are given. Materials to be placed inside the ampoules may consist of stable element materials or radioactive materials in either solid or liquid form. Liquids shall be dried prior to sealing the ampoule.

36 MATERIALS SCIENCE↗

Nondestructive property and defect characterization using X-rays and neutrons

As advanced manufacturing (AM) continues to mature as a fabrication technique, interest in its use for the fabrication of nuclear components continues to grow. AM nuclear parts offer the ability to create parts with complex and non-standard geometries that cannot be produced using traditional manufacturing techniques, circumvention of supply chain issues, and reduction of time from design to implementation. However, components fabricated with AM techniques must undergo nondestructive examination (NDE) to ensure they are fabricated to the required specifications to ensure safe and proper operation. The Advanced Materials and Manufacturing Technologies (AMMT) program has undertaken initial exploratory studies on several NDE techniques to evaluate their feasibility for research and development (R&D), as well as Quality Assurance and Quality Control (QA/QC), and in-service inspections of AM parts. This work describes research results on several techniques, including X-ray and neutron tomography and scattering, as well as photothermal radiometry. The experimental results are described and an overview for each techniques’ potential use on AM parts in the various phases of part development and lifetime is given. Finally, future directions for technique development and application to AM nuclear components are described.

36 MATERIALS SCIENCE↗

Confirming the absence of nuclear warheads via passive gamma-ray measurements

Arms-control agreements between the United States and Russia negotiated after the end of the Cold War have imposed limits on the number of deployed strategic nuclear weapons. Verification of these agreements has relied on onsite inspections, sometimes supported by radiation detection techniques to confirm the absence of a nuclear warhead when ambiguities arise. So far, these measurements have sought to detect neutron emissions associated with the presence of plutonium, but they would be inadequate for uranium devices. In an effort to offer instruments that could be used to confirm the absence of both plutonium and uranium weapons, here we propose an inspection system that uses only passive gamma radiation detection techniques. Such a system would be particularly valuable for next-generation arms-control agreements that limit total numbers of weapons and would involve containerized items in storage. We conducted extensive Monte Carlo simulations to support the development of a verification protocol and detection algorithm. Here, we demonstrate the viability of the technique using standard laboratory check sources and MCNP simulations for simplified configurations of special nuclear material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Non-destructive structural characterization of graphite components using mechanical resonance and deep learning

As compared to conventional nuclear reactors, microreactors have the potential to significantly reduce construction timelines and capital costs, decreasing the barriers for advanced nuclear reactor technologies. However, the lower power output of these microreactors (typically < 20 MWe) creates challenging economics if operation and maintenance costs cannot be sufficiently reduced. The compact size of these designs presents an opportunity for comprehensive in-situ structural health monitoring to provide real-time feedback in order to reduce operational costs associated with maintenance and downtime. Many microreactor concepts use graphite for both in-core neutron moderation and as a structural material, which has typically required some form of periodic and laborious inspection. This report provides a description and assessment of recent work with graphite to couple acoustic-based experimental measurements and characterization with machine learning models to mature structural health monitoring capabilities and generate benefits for the nuclear microreactor industry. With resilient embedded sensors in development in other programs funded by the US Department of Energy’s Office of Nuclear Energy and elsewhere, the work described herein builds upon previously funded efforts to mature non-destructive testing technology that relates measured vibrational signatures to structural changes, using a combination of new experimental measurements and machine learning processing. Building on past successful demonstrations of predictive workflows to identify structural changes in a hexagonal stainless steel test article with excellent acoustic propagation, we first performed baseline characterization on graphite samples with canonical geometries to ensure compatibility and confidence in the applied techniques for a material with distinctly different mechanical properties. In contrast to efforts in previous years, we worked exclusively with unidirectional vibration data that is more comparable to those expected from the existing embedded sensor technologies which are suitable for deployment in a reactor setting. Established acoustic and modern machine-learning-based characterization approaches were applied to the resulting datasets from these simple geometries. Both approaches were found to be highly capable of detecting even small geometric irregularities amongst nominally identical samples. As such, we then moved to testing these approaches for detection of artificial local stress perturbations introduced into a more complex geometry: a hexagonal block with drilled holes. A main outcome of this work is that a generalizable ML workflow can be used to detect and predict the characteristics of small artificial anomalies in a graphite component with a relevant geometry. While this work was performed using surficial vibration data, we expect the approach to be flexible and viable for other monitoring scenarios, such as those with different arrangements or types of sensor arrays. As compared to previously funded efforts, an existing ML workflow based on neural networks was enhanced through the addition of recently developed Fourier neural operators. As applied to previously collected and new vibration datasets, prediction accuracies of anomaly characterizations were greatly improved with minimal added computational cost. As trained on small durations of vibration data (tens of seconds) collected over a realistic number of locations, the model was able to reliably determine the presence of a subtle stress anomaly and begin to provide location estimates. Such an approach is likely to be viable for more relevant reactor damage scenarios for graphite components, such as progressive crack growth or creep.

36 MATERIALS SCIENCE↗

Neutron Imaging for Selective Laser Melting Inconel Hardware with Internal Passages

Additive Manufacturing is showing great promise for the development of new innovative designs and large potential life cycle cost reduction for the Aerospace Industry. However, more development work is required to move this technology into space flight hardware production. With selective laser melting (SLM), hardware that once consisted of multiple, carefully machined and inspected pieces, joined together can be made in one part. However standard inspection techniques cannot be used to verify that the internal passages are within dimensional tolerances or surface finish requirements. NASA/MSFC traveled to Oak Ridge National Lab's (ORNL) Spallation Neutron Source to perform some non-destructive, proof of concept imaging measurements to assess the capabilities to understand internal dimensional tolerances and internal passages surface roughness. This presentation will describe 1) the goals of this proof of concept testing, 2) the lessons learned when designing and building these Inconel 718 test specimens to minimize beam time, 3) the neutron imaging test setup and test procedure to get the images, 4) the initial results in images, volume and a video, 4) the assessment of using this imaging technique to gather real data for designing internal flow passages in SLM manufacturing aerospace hardware, and lastly 5) how proper cleaning of the internal passages is critically important. In summary, the initial results are very promising and continued development of a technique to assist in SLM development for aerospace components is desired by both NASA and ORNL. A plan forward that benefits both ORNL and NASA will also be presented, based on the promising initial results. The initial images and volume reconstruction showed that clean, clear images of the internal passages geometry are obtainable. These clear images of the internal passages of simple geometries will be compared to the build model to determine any differences. One surprising result was that a new cleaning process was used on these simply geometric specimens that resulted in what appears to be very smooth internal surfaces, when compared to other aerospace hardware cleaning methods.

Tramel, Terri L.↗