Search NASASearch

SEARCH · Search NASA

Results for “Instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Steam Generators: Thermal Hydraulic Measurements and Instrumentation

Steam generators are integral components of both conventional and advanced reactors utilizing steam power cycles, as they influence the power conversion performance. Steam generator designs are highly influenced by the type of reactor coolant used, which mainly governs the different control, monitoring, and safety system actuation requirements. Therefore, the present work reviews the thermal hydraulics instrumentation within steam generators designed for pressurized water reactors (PWRs), high-temperature gas-cooled reactors (HTGRs), sodium fast reactors (SFRs), and molten salt cooled reactors (MSRs). Emphasis is given to measurement techniques that are either unique or particularly important to specific reactor types. Lastly, a discussion is provided on the instrumentation and measured parameters. The work identifies standard parameters of interest and is expected to aid the development of test beds and novel measurements techniques.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN

Instrumentation and Samples (CRADA Final Report)

Instruments which are categorized as shared user instruments at the National Laboratory of the Rockies (NLR) will be utilized for ongoing technical work. Samples will be provided by University of Colorado Boulder (CU) and thus no need for materials at NLR is anticipated.

(Ga1- xZnx)(N1-xOx)

Risk-informed Graded Approach for Reliability and Performance Assessment of Sensor and Instrumentation Systems within Advanced Condition Monitoring Technologies

Advanced condition monitoring (ACM) technologies, such as digital twins, are innovative strategies designed to provide real-time health insights, including the remaining useful life of components. The primary goal of ACM is to predict and alert operators to potential functional failures before they occur. ACM systems achieve this by integrating predictive models with various sensor instrumentation, analog-to-digital converters, data warehouses, and data pre-processors. These sensor and instrumentation systems (SIS) are essential for forming a comprehensive understanding of component conditions and ensuring the predictive success of ACM programs. Introducing new technologies like ACM involves varying degrees of risk that can impact plant reliability. Therefore, risk mitigation should be commensurate with the performance and reliability of the developed technology, following a risk-informed graded approach (RIGA). Establishing a RIGA process requires a clear understanding of the hazards and reliability of all subsystems, including their interdependencies and potential impacts on the overall system. Given the critical role of SIS in ACM, this work reviews hazard identification and reliability quantification methods for SIS. It also considers these methods' implications when developing a RIGA process for ACM.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Parallel sorting algorithm classification: is manual instrumentation necessary?

Understanding parallel algorithms is crucial for accelerating scientific simulations on complex, distributed memory, high-performance computers. Modern algorithm classification approaches learn semantics directly from source code to differentiate between algorithms, however, accessing source code is not always possible. We can learn about parallel algorithms from observing their performance, as programs running the same algorithms and using the same hardware should exhibit similar performance characteristics. We present an approach to learn algorithm classes from parallel performance data directly in order to classify algorithms without access to the source code. We extend previous work to enable classifying parallel sorting algorithms using automatic instrumentation instead of requiring manual region annotations in the source code. In this work, we design and demonstrate a study for classification of parallel sorting algorithms using parallel performance data collected from automatic instrumentation, and evaluate the performance of our new methodology on classification. We leverage Caliper to collect the performance data, Thicket for our exploratory data analysis (EDA), and PyTorch and Scikit-learn to evaluate the effectiveness of random forests, support vector machines (SVMs), decision trees, neural networks, and logistic regressions on parallel performance data. Additionally, we study noise in parallel performance data, whether the removal of noise and pre-processing of the data is necessary to accurately classify parallel sorting algorithms, and determine the effectiveness of features created from performance data. In conclusion, we demonstrate classification accuracy for these five different models of up to 97.7% across four different parallel algorithm classes.

Algorithm Classification

Optimization of ray-tracing simulations to confirm performance of the GP-SANS instrument at the High-Flux Isotope Reactor

The CG-2 beamline at the High Flux Isotope Reactor (HFIR) exhibits a notable discrepancy between observed count rates and the count rates we would expect based on a Monte-Carlo neutron ray-trace simulation. These simulations consistently predict count rates approximately five times greater than those observed in four separate experimental runs involving different instrument configurations. This discrepancy suggests that certain factors are causing losses in measurements that are not adequately accounted for in the simulation, in particular guide reflectivity or misalignment. To investigate these discrepancies, a high-dimensional simulation parameter approach is applied in order to understand the losses. Region of Interest (ROI) groups along the instrument are assigned to different surfaces of the guide components within the simulation. This allows the parameters of those guide components to be varied as a group to minimize the complexity of the search space. The result is an optimization of simulation parameters using an iterative scheme that aims to minimize the difference between experimentally measured count rates and simulated count rates across all tested collimator combinations. This proposed methodology holds the potential to reveal previously unrecognized sources of intensity loss in the CG-2 beamline at HFIR and improve the accuracy of simulations, leading to enhanced understanding and performance of the beamline for various scientific applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

Evaluating Cloud Properties at Scott Base: Comparing Ceilometer Observations With ERA5, JRA55, and MERRA2 Reanalyses Using an Instrument Simulator

This study compares CL51 ceilometer observations made at Scott Base, Antarctica, with statistics from the ERA5, JRA55, and MERRA2 reanalyses. To enhance the comparison we use a lidar instrument simulator to derive cloud statistics from the reanalyses which account for instrumental factors. The cloud occurrence in the three reanalyses is slightly overestimated above 3 km, but displays a larger underestimation below 3 km relative to observations. Unlike previous studies, we see no relationship between relative humidity and cloud occurrence biases, suggesting that the cloud biases do not result from the representation of moisture. We also show that the seasonal variation of cloud occurrence and cloud fraction, defined as the vertically integrated cloud occurrence, are small in both the observations and the reanalyses. We also examine the quality of the cloud representation for a set of weather states derived from ERA5 surface winds. The variability associated with grouping cloud occurrence based on weather state is much larger than the seasonal variation, highlighting weather state is a strong control of cloud occurrence. All the reanalyses continue to display underestimates below 3 km and overestimates above 3 km for each weather state. But the variability in ERA5 statistics matches the changes in the observations better than the other reanalyses. We also use a machine learning scheme to estimate the quantity of supercooled liquid water cloud from the ceilometer observations. Ceilometer low-level supercooled liquid water cloud occurrences are considerably larger than values derived from the reanalyses, further highlighting the poor representation of low-level clouds in the reanalyses.

54 ENVIRONMENTAL SCIENCES

VISION: a modular AI assistant for natural human-instrument interaction at scientific user facilities

Scientific user facilities, such as synchrotron beamlines, are equipped with a wide array of hardware and software tools that require a codebase for human-computer-interaction. This often necessitates developers to be involved to establish connection between users/researchers and the complex instrumentation. The advent of generative AI presents an opportunity to bridge this knowledge gap, enabling seamless communication and efficient experimental workflows. Here we present a modular architecture for the Virtual Scientific Companion by assembling multiple AI-enabled cognitive blocks that each scaffolds large language models (LLMs) for a specialized task. With VISION, we performed LLM-based operation on the beamline workstation with low latency and demonstrated the first voice-controlled experiment at an x-ray scattering beamline. The modular and scalable architecture allows for easy adaptation to new instruments and capabilities. Development on natural language-based scientific experimentation is a building block for an impending future where a science exocortex—a synthetic extension to the cognition of scientists—may radically transform scientific practice and discovery.

36 MATERIALS SCIENCE

An iterative CMB lensing estimator minimizing instrumental noise bias

Noise maps from cosmic microwave background (CMB) experiments are generally statistically anisotropic, due to scanning strategies, atmospheric conditions, or instrumental effects. Any mismodeling of this complex noise can bias the reconstruction of the lensing potential and the measurement of the lensing power spectrum from the observed CMB maps. We introduce a new CMB lensing estimator based on the maximum (MAP) reconstruction that is minimally sensitive to these instrumental noise biases. By modifying the likelihood to rely exclusively on correlations between CMB map splits with independent noise realizations, we minimize autocorrelations that contribute to biases. In the regime of many independent splits, this maximum closely approximates the optimal MAP reconstruction of the lensing potential. In simulations, we demonstrate that this method is able to determine lensing observables that are immune to any noise mismodeling with a negligible cost in signal-to-noise ratio. Our estimator enables unbiased and nearly optimal lensing reconstruction for next-generation CMB surveys.

Legrand, Louis [University of Cambridge (United Ki

Anomaly Detection in Seismic Data with Deep Learning: Application for Instrument Failure Detection and Forecasting

Seismic data quality assessment (QA) is the first and one of the most important steps before conducting any further data analysis. Traditional methods involve checking various metrics, such as spike detection and power spectral density, by setting strict thresholds or comparing data against synthetic benchmarks. However, these approaches often rely on pre-existing knowledge and assumptions about data anomalies, leading to potential misclassification of unusual cases. Here, in this study, we propose a deep autoencoder model, an unsupervised learning approach that evaluates data quality without making assumptions about normal and anomalous data, which can be used to identify deviations in recorded data that may indicate nascent instrument failure. We test the model with the U.S. International Monitoring System (IMS) seismic stations and demonstrate the capability of detecting anomalies on a monthly scale. This could prompt station operators to examine potential problems early, allowing sufficient time for instrument maintenance to prevent data outages. In addition, we use a new manually selected testing dataset to compare our model performance against two supervised machine learning (ML) approaches and a standard QA package, as baseline models. When applied to the dataset containing known data anomalies, performance of the supervised and unsupervised ML approaches is similar, with an accuracy of 88.1% for our model compared to ∼90% for the supervised ML approach and 78.2% for the standard QA package. Our model outperforms the baseline models when applied to new stations, where new types of data anomalies can be station-specific and not included in the training dataset. Finally, we show model transferability by training the model with data from the Global Seismograph Network only and applying it to the IMS network data. The results suggest that our model is generalizable and can be applied to new stations with good accuracy.

Lin, Jiun-Ting [Lawrence Livermore National Labora

Improving Self-Driving Labs: Quantifying System-Level Experiment Repeatability and Broadening Instrument-Level Compatibility

Modular Autonomous Research System (MARS) is a self-driving laboratory (SDL) which performs wet-lab science with peptide-lanthanide combinations in an automated and, ultimately, an autonomous manner to aid in soil analysis for domestic lithium mining. Autonomous experimentation involves automated experimentation, experiment planning, and active learning. MARS consists of a 6-axis robotic arm (UR5e) on a linear rail, pipette robots (Opentrons 2), and microplate readers. These components transport, operate on, and collect data with chemical solutions in standard labware. For effective autonomy, MARS must perform system-level labware operations repeatably, plan experiments autonomously, and be portable between research-domains. Repeatability is evaluated by labware placement precision, such that future operations can properly locate labware, as well as the elapsed time, so that low variance mean estimates of experiment duration can inform high-level researcher decision making. Autonomous experiment planning is the next step to decouple experimentation from human management; however, there is a conflict between the ideal system-level experiment goals and the constraints imposed by instruments’ limitations. Sub-domain portability is a long-term goal to extend MARS’ research beyond the chemistry of peptide-lanthanide binding to other sub-domains without having to invest significant overhead to system retrofitting. To address these goals, we manually trained the robotic arm labware placement and modelled statistical failurerate and uncertainty Additionally, we benchmarked the duration and variance of each experiment sub-operation as a heuristic for research decision making. Next, we use a parameterized geometric program (PGP) approach to design experiments that optimize system-level objectives and satisfy instrument-level constraints. Lastly, we proposed a Python framework to maximize MARS’ extensibility to other scientific sub-domains through a JSON-based experiment specification.

36 MATERIALS SCIENCE

Status of the Dark Energy Spectroscopic Instrument (DESI) and Year 1 Cosmology results

The Dark Energy Spectroscopic Instrument (DESI) will measure the effect of dark energy on the expansion of the universe. It will obtain optical spectra for tens of millions of galaxies and quasars, constructing a 3D map spanning the nearby universe to 11 billion light years. The DESI Survey is being conducted on the Mayall 4-meter telescope at Kitt Peak National Observatory. DESI is supported by the Department of Energy Office of Science to perform this Stage IV dark energy measurement using baryon acoustic oscillations and other techniques that rely on spectroscopic measurements. I will discuss the status of the Dark Energy Spectroscopic Instrument (DESI) survey and present our Year 1 Baryon Acoustic Oscillation measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Miniaturized Scanning Electrical Mobility Sizer (mSEMS) Instrument Handbook – Airborne Version

The miniaturized scanning electrical mobility sizer (mSEMS), as shown in Figure 1, represents an advancement in particle size measurement technology. Designed for portability, this compact instrument is engineered to deliver precise and accurate assessments of particle size distributions. The mSEMS uses scanning electrical mobility sizing technology to analyze aerosol particles within a specified size range. Its miniaturized design does not compromise on performance, making it ideal for a myriad of applications across laboratory research, environmental monitoring, and industrial settings. The user friendly interface simplifies operation, while the instrument's robust construction ensures reliability in various conditions. Researchers and professionals can rely on the mSEMS to provide invaluable insights into aerosol dynamics, contributing to advancements in aerosol science.

54 ENVIRONMENTAL SCIENCES

Remote Instrumentation and Data Acquisition

This poster outlines the development and implementation of a remote data acquisition system for waveform analysis using a Rohde & Schwarz oscilloscope. The project involved capturing waveform data, and transferring it to a local machine for visualization and analysis. The core logic was developed in C++ with a focus on object oriented programming and the use of polymorphism so the main application can interact with any instrument without knowing its exact type, simplifying the overall logic and making it easier to add or swap out components without changing the rest of the codebase.. The system issues Standard Commands for Programmable Instruments (SCPI) via a socket connection and parses the oscilloscope s ASCII waveform data. The C++ application was containerized using Docker for ease of portability, and reproducibility. Emphasis was placed on secure networking practices, error handling, and effective data capture. The report describes the technical steps taken, challenges encountered, and future work, providing insight into the practical integration of hardware interfacing with remote computational environments.

Parikh, Jaymil [Illinois U., Urbana]

Rethinking Coherent Diffraction Instruments for High Brightness Sources

Over the past two decades, exceptional progress has been made providing coherent x-ray beams at both high-brightness synchrotron sources and x-ray free electron lasers (XFEL). The availability of these coherent x-rays has led to a surge in instruments that exploit x-ray coherence for either x-ray photon correlation spectroscopy (XPCS) or coherent diffraction imaging (CDI). A key to these techniques has been to resolve, or at least nearly resolve, the speckles associated with the scattering from structural disorder. Given practical limits on detector pixel size, this requires long sample-to-detector distances. This paper presents numerical simulations of an instrument that can efMiciently provide a long sample-detector distance while maintaining the ability to rapidly set momentum transfer by inserting crystals with different order in the incident beam, thus changing in incident direction instead of moving the detector.

Fuoss, Paul H

Advanced Instrumentation for Metal Additive Manufacturing

Laser powder bed fusion (LPBF) is the most widely used process for metal additive manufacturing (AM), particularly where complex geometries provide performance advantages unattainable with traditional manufacturing techniques. However, LPBF is highly sensitive to innate variability in both the powder spreading and fusion steps, often leading to defects such as pores that are difficult to detect yet significantly impair component mechanical properties and fatigue life. This thesis presents a range of novel instruments enabling both precise assessment of powder layer characteristics and in-situ thermal metrology of metal AM to advance the quality control of LPBF. First, leveraging a custom X-ray microscope and a radiation-transport model developed through this work, transmission X-ray imaging is used to study spreading of thin metal powder layers. Effective layer depth is directly mapped at a process-relevant size scale, surpassing optical techniques that can only estimate local deposition from layer surface topography. Layer packing density and quality are shown to be influenced by powder flowability and particle size relative to nominal powder layer thickness. Layer quality is additionally connected to the geometry of the spreading implement and its velocity. This technique and its presented findings enable pairing feedstocks with spreading strategies that create layers with consistent packing density and uniformity. Second, a twofold approach is employed to optically interrogate the laser fusion step of LPBF for observing signatures of defect formation. Aperture division multiplexing is conceptualized, providing for simultaneous laser delivery and high-fidelity infrared (IR) process monitoring through a common optic. In-situ microscopy at 50 μm spatial resolution and at mid-wave IR wavelengths is proven readily achievable with the first purpose-built optic of this type. Next, a bespoke imaging spectrometer, along with a temperature-emissivity separation technique, is used to retrieve accurate process temperatures over a 1000 K range. Data from these instruments are correlated to porosity as fine as 4.3 μm in two LPBF test artifacts, as verified using computed tomography (CT), establishing the viability of robust optically-based component qualification.

Penny, Ryan

Remote Instrumentation and Data Acquisition: An Internship Research Report

This report outlines the development and implementation of a remote data acquisition system for waveform analysis using a Rohde & Schwarz oscilloscope. The project involved capturing waveform data, and transferring it to a local machine for visualization and analysis. The core logic was developed in C++ with a focus on object oriented programming and the use of polymorphism so the main application can interact with any instrument without knowing its exact type, simplifying the overall logic and making it easier to add or swap out components without changing the rest of the codebase.. The system issues Standard Commands for Programmable Instruments (SCPI) via a socket connection and parses the oscilloscope’s ASCII waveform data. The C++ application was containerized using Docker for ease of portability, and reproducibility. Emphasis was placed on secure networking practices, error handling, and effective data capture. The report describes the technical steps taken, challenges encountered, and lessons learned, providing insight into the practical integration of hardware interfacing with remote computational environments.

Parikh, Jaymil [Fermilab]

Delving into the depths of NGC 3783 with XRISM II. Cross-calibration of X-ray instruments used in the large, multi-mission observational campaign

Context. Accurate X-ray spectroscopic measurements are fundamental for deriving basic physical parameters of the most abundant baryon components in the Universe. The plethora of X-ray observatories currently operational enables a panchromatic view of the high-energy emission of celestial sources. However, uncertainties in the energy-dependent calibration of the instrument transfer functions (e.g. the effective area, energy redistribution, or gain) can limit - and historically, did limit - the accuracy of X-ray spectroscopic measurements. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign.

Active Galactic Nuclei, individual: NGC 3783

MARVEL Instrumentation, Control, and Software Considerations

This paper details the various I&C considerations and design decisions made throughout the MARVEL (Micro-reactor Applications Research Validation and Evaluation) project, including sensor and actuator selection, safety-related functionality, digital control hardware and software, and testing methodologies. Key challenges such as managing radiation, temperature, and space constraints are discussed, along with the trade-offs between using standard equipment and custom solutions. The successful integration of off-the-shelf components, the emphasis on minimizing safety-related instrumentation, and the lessons learned from prototyping and testing are highlighted. The authors aim to provide insights that can benefit future micro-reactor designs and emphasize the importance of real-world testing in advancing reactor technology.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN