At least 55 records · Page 3

A High-Precision, Fast-Response Airborne CO2 Analyzer for In Situ Sampling From the Surface to the Middle Stratosphere

Two in situ CO2 analyzers have been developed for deployment on the NASA ER-2 aircraft and on stratospheric balloons. The ER-2 instrument has had more than 150 flights during 21 deployments from 1992 to 2000, resulting in a dataset with nearly pole-to-pole coverage that includes data from all seasons in both hemispheres except austral summer. In-flight calibrations show that the typical long-term (i.e. flight-to-flight) precision of the instruments is better than plus or minus 0.1 ppmv. The flight standards are traceable to standards held by the Scripps Institute of Oceanography and the National Oceanic and Atmospheric Administration's Climate Monitoring and Diagnostics Laboratory. The balloon instrument has had 8 balloon flights since September 1996, providing the first in situ observations of CO2 above approx. 21 km. In addition, the balloon instrument has been flown onboard a Cessna Citation II aircraft for sampling between the surface and 10 km. In this paper, the instrumentation and calibration procedures for both instruments are described in detail. An intercomparison of the two instruments during the Photochemistry of Ozone Loss in the Arctic Region In Summer (POLARIS) project showed that, on average, the instruments agreed to within 0.05 ppmv.

Daube, B. C., Jr.↗

STDN network operations procedure for Apollo range instrumentation aircraft, revision 1

The Apollo range instrumentation aircraft (ARIA) fleet which consists of four EC-135N aircraft used for Apollo communication support is discussed. The ARIA aircraft are used to provide coverage of lunar missions, earth orbit missions, command module/service module separation to spacecraft landing, and assist in recovery operations. Descriptions of ARIA aircraft, capabilities, and instrumentation are included.

Vette, A. R.↗

Charge-coupled device imaging spectroscopy of Mars. I - Instrumentation and data reduction/analysis procedures

This paper describes the collection, reduction, and analysis of 0.4-1.0-micron Mars imaging spectroscopy data obtained during the 1988 and 1990 oppositions from Mauna Kea Observatory and provides a general outline for the acquisition and analysis of similar imaging spectroscopy data sets. The U.H. 2.24-m Wide Field Grism CCD Spectrograph was used to collect 13 3D image cubes covering 90 percent of the planet south of 50 deg N in the 0.4-0.8 micron region and covering 55 percent of the planet south of 50 deg N in the 0.5-1.0 micron region. Spectra extracted from these image cubes reveal the detailed character of the Martian near-UV to visible spectrum. Images at red wavelengths reveal the 'classical' albedo markings at 100-500 km spatial resolution while images at blue wavelengths show little surface feature contrast and are dominated by condensate clouds/hazes and polar ice.

Bell, James F., III↗

Flight Test Evaluation of Autonomous Descending-Decelerating Precision Point-in-Space Approach to the Ground

New forms of highly automated Advanced Air Mobility (AAM) aircraft, such as electric vertical take-off and landing (eVTOL) vehicles, could transform transportation, cargo delivery, and a variety of public services. The National Aeronautics and Space Administration (NASA) conducted a series of flight demonstrations in collaboration with the Defense Advanced Research Projects Agency (DARPA) and Sikorsky Aircraft (a Lockheed Martin company) to progressively evaluate autonomous technologies. The autoland flight test research is a first in series for investigating the world’s first procedural descending-decelerating automated landing with vertical guidance Instrument Flight Procedures (IFP). The Sikorsky Optionally Piloted Vehicle (OPV) experimental UH-60 Black Hawk was used to evaluate a flight path’s four-dimensional trajectory (4DT) management into primitive commands and then follow those commands to a Point-in-Space (PinS) landing to the ground. All flight procedures were manually flown to the ground at 12 degrees with a 20-knot tail wind to ensure flight safety before automation was engaged. New and novel high precision approach procedures could pave the way for all future VTOL operations.

David Zahn↗

Calibration of long term satellite ozone data sets using the space shuttle

Trends in atmospheric ozone continue to be an environmental concern. Drifts in satellite observations are the major obstacle in the detection of changes in global ozone over the long term. Careful re-analysis of satellite ozone data along with groundbased observations have more or less corroborated photochemical models which predict ozone depletion. However, there remains the margin of error in the observations that is as large as the trend itself. The National Plan for Stratospheric Monitoring calls for monitoring global ozone for at lease the next ten years employing the NOAA polar orbiting satellites. Ozone observations will be made with the Solar Backscatter Ultraviolet Spectral Radiometer Mod 2 (SBUV/2) which ia a refinement of the SBUV instrument flying on NASA's Nimbus-7 satellite. The first instrument in the operational series began taking data from the NOAA-9 spacecraft in February 1985. A second instrument was launched on NOAA-11 in September 1988. Both continue to operate. Earlier attempts to calibrate satellite data relied on comparisons with ground based observations. However, differences in instrumental techniques severely complicated these efforts. This problem will be over come by regular flights, about once per year, of the Shuttle Solar Backscatter Ultraviolet radiometer (SSBUV). The data from the SSBUV instrument will be compared with nearly coincident data taken by the NOAA satellite instruments. This procedure will permit a direct calibration transfer in space, since the two instruments observe the same qualities thereby bypassing the inversion algorithm which converts the observations to ozone amounts.

Hilsenrath, Ernest↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2024 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2024 edition includes updates to the appendices to reflect the instrument changes from one year to another.

14 SOLAR ENERGY↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2025 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2025 edition includes updates to the appendices to describe the current instrumentation of the NREL-SRRL.

14 SOLAR ENERGY↗

Calibration of transonic and supersonic wind tunnels

State-of-the art instrumentation and procedures for calibrating transonic (0.6 less than M less than 1.4) and supersonic (M less than or equal to 3.5) wind tunnels were reviewed and evaluated. Major emphasis was given to transonic tunnels. Continuous, blowdown and intermittent tunnels were considered. The required measurements of pressure, temperature, flow angularity, noise and humidity were discussed, and the effects of measurement uncertainties were summarized. A comprehensive review of instrumentation currently used to calibrate empty tunnel flow conditions was included. The recent results of relevant research are noted and recommendations for achieving improved data accuracy are made where appropriate. It is concluded, for general testing purposes, that satisfactory calibration measurements can be achieved in both transonic and supersonic tunnels. The goal of calibrating transonic tunnels to within 0.001 in centerline Mach number appears to be feasible with existing instrumentation, provided correct calibration procedures are carefully followed. A comparable accuracy can be achieved off-centerline with carefully designed, conventional probes, except near Mach 1. In the range 0.95 less than M less than 1.05, the laser Doppler velocimeter appears to offer the most promise for improved calibration accuracy off-centerline.

Reed, T. D.↗

A review of some radiometric calibration problems and methods

The in-flight radiometric calibration instrumentation and procedures of the Landsat Thematic Mapper and the high-resolution visible-range instruments of SPOT are illustrated with drawings and diagrams, characterized, and compared. Problems encountered in the laboratory calibration process, minimizing the temporal instability of the systems, identifying anomalies in the electronics in flight, and rechecking the calibration are examined, and it is pointed out that the stability of the calibration systems is less than that of the instruments themselves. The use of carefully measured ground-site data and atmospheric parameters in combination with radiative-transfer models for periodic calibration is recommended.

Slater, P. N.↗

Improvements to satellite retrieval systems. The operational perspective

Operational weather satellites are built as a series of nearly identical instruments which are flown for 5 to 7 years. Minor improvements are made during the life of the series. However, major improvements and changes in design are made with the initiation of a new series of instruments. Similarly, procedures used to process the data are characterized by frequent changes early in the life of a satellite series as user experience is gained with the new instrument. Later the changes become less frequent, both because the processing system becomes well tuned to that particular set of instruments and because, at the end of a series, resources are devoted to generating the processing system for the next set of instruments. Past and present systems are considered with emphasis on the vertical temperature profile radiometer and a procedure for deriving clear radiances in partly cloudy areas.

Mcmillin, L.↗

Instrument technology for remote-surface exploration, prospecting and assaying, part 2

The capability to specify new instrument/mechanism technology needs, for effective remote surface exploration, prospecting and assaying (EPA), requires first, an understanding of the functions or major elements of such a task, and second an understanding of the scientific instruments and support mechanisms that may be involved. An analog or task model was developed from which the various functions, operational procedures, scientific instruments, and support mechanisms for an automated mission could be derived. The task model led to the definition of nine major functions or categories of discrete operational elements that may have to be accomplished on a mission of this type. Each major function may stand alone as an element of an EPA mission, but more probably a major function will require the support of other functions, so they are inter-related.

Brereton, R. G.↗

Spectral and radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer

The laboratory spectral and radiometric calibration of the AVIRIS science data collected since 1987 is described. The instrumentation and procedures used in the calibration are discussed and the accuracy achieved in the laboratory as determined by measurement and calculation is compared with the requirements. Instrument performance factors affecting radiometry are described. The paper concludes with a discussion of future plans.

Vane, Gregg↗

Spectral and radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer

The laboratory spectral and radiometric calibration of the AVIRIS science data collected since 1987 is described. The instrumentation and procedures used in the calibration are discussed and the accuracy achieved in the laboratory as determined by measurement and calculation is compared with the requirements. Instrument performance factors affecting radiometry are described. The paper concludes with a discussion of future plans.

Vane, Gregg↗

Flight flutter testing the B-58 airplane

The flight flutter tests on the B-58 airplane are described, and the philosophy of flight flutter testing is discussed. The instrumentation used in the airplane and in the telemetering receiving station on the ground is described along with the methods used for exciting the airplane and the flight test procedure. Also described is the type of data obtained and its reduction. An evaluation of the procedure and instrumentation is given with a discussion of desirable improvements for future testing.

Mahaffey, P. T.↗

Visual-Accommodation Trainer/Tester

Ophthalmic instrument tests and helps develop focusing ability. Movable stage on a fixed base permits adjustment of effective target position as perceived by subject. Various apertures used to perform tests and training procedures. Ophthalmic instrument provides four functions: it measures visual near and far points; provides focus stimulus in vision research; measures visual-accommodation resting position; can be used to train for volitional control of person's focus response.

Randle, Robert J., Jr.↗