Search NASA⌕ Search

SEARCH · Search NASA

Results for “Insulation Degradation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Evaluation of Surface Crack Formation in Photovoltaic Backsheets Using Fragmentation and Finite Element Simulations: Preprint

Backsheet cracking is among the most commonly observed degradation modes of photovoltaic (PV) modules in the field. Cracks can reduce the ability of backsheets to fulfil their functions, for example, protection of the modules from the environment or electrical insulation. This work presents an evaluation of the degradation and cracking propensity of two backsheets during accelerated IEC TS 62788-7-2 A3 (International Electrotechnical Commission) aging with the fragmentation test: a co-extruded polyamide backsheet (AAA), and a laminated multilayer backsheet with a polyethylene terephthalate core and outer layer and ethylene vinyl acetate inner layer (PPE). Results show the surface embrittlement of the AAA outer layer during exposure. A longer time of exposure causes cracks to form at lower strains during stretching and creates deeper cracks. Accordingly, Young's modulus of the outer layer increases, as measured by cross-sectional nanoindentation. PPE exhibits cracking after exposure as well. While no similar increase of modulus or crack depth can be observed, the outer layer of PPE exhibits more obvious signs of erosion during exposure, including progressive morphological changes and thickness losses. A finite element model to simulate surface crack formation is devised, based on initially zero-thickness decohesion elements. Decohesion criteria define a critical stress, at which these elements grow, and cracks can begin to form. These criteria are obtained via parameter optimization by comparison between simulation and experiment. The model is used to interpret crack formation in both backsheets.

backsheet↗

Evaluation of Surface Crack Formation in Photovoltaic Backsheets Using Fragmentation and Finite Element Simulations

Backsheet cracking is among the most commonly observed degradation modes of photovoltaic modules in the field. Cracks can reduce the ability of backsheets to fulfill their functions, such as protection of the modules from the environment or electrical insulation. Here, this work presents an evaluation of the degradation and cracking propensity of two backsheets during accelerated IEC TS 62788-7-2 (International Electrotechnical Commission) aging under the A3 condition with a fragmentation test using a coextruded polyamide backsheet (AAA), and a laminated multilayer backsheet with a polyethylene terephthalate core and outer layer and ethylene vinyl acetate inner layer (PPE). Results show the surface embrittlement of the AAA outer layer during exposure. A longer time of exposure causes cracks to form at lower strains during stretching and creates deeper cracks. Accordingly, Young's modulus of the outer layer increases, as measured by cross-sectional nanoindentation. PPE exhibits cracking after exposure as well. While no similar increase of modulus or crack depth can be observed, the outer layer of PPE exhibits more obvious signs of erosion during exposure, including progressive morphological changes and thickness losses. A finite element model is developed to simulate surface crack formation, based on initially zero-thickness decohesion elements. Decohesion criteria define a critical stress, at which these elements grow, and cracks can begin to form. These criteria are obtained via parameter optimization by comparison between simulation and experiment. The model is used to interpret crack formation in both backsheets.

14 SOLAR ENERGY↗

3D Frequency Domain Reflectometry Digital Twin of an Electrical Cable: A First Glance

Electrical cables within nuclear power plants (NPPs) are critical components required for power, control, and instrumentation systems which may be exposed to stressors, such as elevated temperatures and gamma radiation. Such stressors can lead to a reduction in the remaining useful life of electrical cables, jeopardizing the safety of NPP systems. To evaluate the effect of stressors on the degradation of electrical cables, electrical reflectometry methods are commonly employed. Frequency domain reflectometry (FDR) is a non-destructive electrical reflectometry method that uses transmission line theory to detect degradation or impedance changes within electrical cables. However, in most cases FDR is only applied to de-energized cables, limiting the application in NPPs as the cable system must be taken offline. In this work, we explore the development of an FDR digital twin to predict the degradation of an electrical cable exposed to elevated temperature, which is expected to reduce the need for offline FDR. A 3-conductor low-voltage electrical cable was selected for evaluation of the digital twin. The fully three-dimensional digital twin was developed in COMSOL using the RF module. A cable length of 30-m and frequency bandwidth of 400 MHz was selected to mimic real-world application of FDR. Over a 1-m region, the permittivity of the insulation was varied by up to 20% to model thermal degradation. The results demonstrate accurate detection of the insulation damage region, supporting further investigation of the FDR digital twin using real-world data and machine learning for predictive damage estimation or remaining lifetime.

Spencer, Mychal P.↗

Degradation of Lithium Iron Phosphate Sulfide Solid-State Batteries by Conductive Interfaces

The superionic solid-state argyrodite electrolyte Li 6 PS 5 Br can improve lithium and lithium-ion batteries' safety and energy density. Despite many reports validating the conductivity of this electrolyte, it still suffers from passivating electrode degradation mechanisms. At first analysis, lithium iron phosphate (LFP) should be more thermodynamically stable in contact with sulfide electrolytes. However, without substantial improvements to interfacial engineering, we find that LFP is not inherently stable against Li 6 PS 5 Br. We hypothesize argyrodite oxidation favorably competes with LFPAs delithiation, insulating the electrolyte-electrode interface and causing large overpotential losses. We show that compared to LiNi x Mn y Co z O 2 , LFP has no actual electrochemical stability advantage despite operating at a lower voltage. We utilize tender energy XAS and XPS to show that chemical reactions occur between LFP and the Li 6 PS 5 Br solid electrolyte and these reactions are exacerbated by cycling. We also show that electrochemical degradation occurs at the interface between the solid electrolyte ion conductor and any electron conductor, namely the active material and carbon additives. We further demonstrate that LiNbO 3 cathode coatings on LFP can delay electrochemical degradation by electronically insulating the LFP-sulfide electrolyte interface but not prevent its occurrence at the carbon-electrolyte interface.

25 ENERGY STORAGE↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Increased Defect Resistance and Ordering in MnBi 2 (Se 1– x Te x ) 4 via Accurate Diffusion Monte Carlo

Stabilizing materials and controlling defect formation remain key challenges in materials science, particularly for theory, where small energy differences must be resolved for accurate predictions. Here, we applied state-of-the-art theoretical methods to topological materials, focusing on MnBi 2 Te 4 (MBT), which is a promising intrinsic magnetic topological insulator. Antisite defects in MBT alter its electronic structure and magnetism, degrading topological properties and causing experimental inconsistencies. Using diffusion Monte Carlo and density functional theory, we investigated the thermodynamic stability and defect formation in MBT, MnBi 2 Se 4 (MBS), and MnBi 2 (Se 1–x Te x ) 4 . We found that MnBi 2 Se 2 Te 2 can be stable at finite temperatures, with higher defect formation energies due to stronger Mn–Se bonding and reduced internal strain. Se preferentially substitutes Te near Mn instead of Te in the outer layer, encouraging long-range ordering when incorporated. For MnBi 2 (Se 1–x Te x ) 4 , cluster expansion phase diagrams revealed solid solution behavior when x <0.5 and phase separation for larger x. MBT and MBS are topological insulators; therefore, the MnBi 2 (Se 1–x Te x ) 4 family could offer tunable topological behavior and improved stability.

MnBi2Te4↗

Investigation of Inverse Temperature Effects During Thermal-Radiation Aging of Semicrystalline Cable Insulation

Inverse temperature effects were observed for semi-crystalline polymers subjected to combined thermal and irradiation aging. The mechanical durability of materials aged at low temperatures degrades with dose faster than at high temperatures. In this paper, two crosslinked polyethylene (XLPE) and two ethylene propylene rubber (EPR) type nuclear cable insulations were exposed to thermal-radiation aging at 100Gy/h up to 30Mrad and three temperatures (26°C, 50°C, 90°C). Their mass change and color change after aging were analyzed.

Ni, Yelin↗

Consistent Timing of Arctic Permafrost Loss Across the CESM1 Large Ensemble

Abstract The Arctic is especially vulnerable to climate change and is warming faster than the global average. Changes in this region pose a heightened threat due to the immense amount of carbon frozen as organic material in the soil. When permafrost thaws, organic material decays and releases as greenhouse gases into the atmosphere, contributing to further warming. A better understanding of the processes that influence permafrost degradation is needed to inform climate adaptation and mitigation planning. This study assesses changes to Arctic permafrost across 35 ensemble member simulations from the Community Earth System Model 1 Large Ensemble Project, under the Representative Concentration Pathway 8.5 21st century scenario. Most Arctic near‐surface permafrost is lost by 2100, but timing varies across regions and with soil depth. Internal climate variability, represented by differences between ensemble members, has a constrained influence on degradation timing due to relative consistency of summer temperature increases and insulation by winter snow cover.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Copper Catalytic Effects in Cable Insulation Polymers

This paper summarizes work performed to evaluate a phenomenon that occurs in electrical cable insulation polymers subjected to accelerated aging while in contact with copper metal. This effect, commonly known as the copper catalytic effect, is a result of chemical reactions that occur when copper ions diffuse into insulation polymers. This diffusion process is observed in various types of polymeric materials exposed to elevated temperatures and happens at the interface between the insulation and metallic components (e.g., conductor, shielding, etc.) in a cable. This polymer-metal interaction has only been observed in cables constructed with copper components (i.e., no interactions observed in cables with aluminum or other metal conductor/shielding) and results in a significant catalytic effect that increases the oxidation rate (e.g., aging) of the material. Under this research, the copper catalytic effects observed in cross-linked polyethylene, cross-linked polyolefin and ethylene propylene rubber insulated cables subjected to thermal accelerated aging were evaluated. These evaluations involved applying infrared spectroscopy, microscopy, and energy dispersive X-ray spectroscopy cross-sectional depth profiling to obtain an in-depth understanding of the aging characteristics of the materials under accelerated conditions. Based on the results of these assessments, the copper catalytic effect can have a significant impact on the mechanical, thermal, chemical, and electrical properties of cable insulation polymers. Here, the results acquired from this research provided the information needed to characterize the copper catalytic effects observed in these polymers, analyze how this phenomenon affected the polymer degradation process, and compare and understand the differences in the properties of the materials.

42 ENGINEERING↗

Time- and strain-dependent nanoscale structural degradation in phase change epitaxial strontium ferrite films

Topotactic phase transition between metallic, perovskite SrFeO 3 and insulating, Brownmillerite SrFeO 2.5 has been extensively studied due to the potential applications in resistive switching devices for neuromorphic computing. However, its practical utilization as memristors has been hindered by the structural instability of SrFeO 3 , which is often ascribed to the generation of oxygen vacancies to form SrFeO 3-δ . Here we reveal the dominating defects generated in SrFeO 3 epitaxial thin films are atomic scale gaps as a result of interfacial strain. Our correlated time- and strain-dependent measurements show that tensile strained SrFeO 3 films form vertical, nanoscale gaps that are SrO-rich, which are accountable for the observed metal-to-insulator transition over time. While compressively strained or small lattice mismatched SrFeO 3 films mainly yield horizontal gaps with a smaller impact on the in-plane transport. The atomic scale origin of such defects and their impact on device performance need to be further understood in order to integrate phase change materials in oxide electronics.

36 MATERIALS SCIENCE↗

Photovoltaic Cable Connectors: A Comparative Assessment of the Present State of the Industry

The consequences of failure for balance-of-systems components (such as photovoltaic (PV) cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and overtemperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared with field-degraded specimens. A total of 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens), including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components.

cable connectors↗

Nanoporous Wood Chips Based Sizable, Robust, and Low-Cost Honeycomb Vacuum Insulation Panels (DOE BENEFIT Final Research Performance Progress Report (RPPR))

Conventional vacuum insulation panels (VIPs) suffer from severe limitations including high cost, vulnerability to perforation, and significant performance degradation over time due to vacuum loss. InventWood Inc. (IW) and partnering teams completely re-engineered the VIP structure by constructing arrays of isolated vacuum-cells to enable limited cutting at designated areas (in between vacuum cells) and reduced consequential vacuum loss due to puncture. The teams also replaced the expensive vacuum insulation core materials with a low-cost commercial wood pulp and recycled long fiber. The wood pulp derived VIP can deliver an overall panel insulation of R15 (<0.01W/m·K) with over 90% thermal resistance retention after cutting (R13.5 overall, R5 along the cut edges). In addition, the vacuum-cell-array design minimizes edge losses, resulting in more durable performance, longer service life (>50 years), and higher R-value per dollar towards a cost target of <$1/ft 2 ·in. It is anticipated that the Nanochip-VIP will attract strong market interest and become an affordable insulation solution for energy efficient buildings and retrofits, leading to significant reductions in energy usage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wear in particle based CSP systems from particle abrasion and attrition at high temperature

High temperature particle-based receivers offer distinct advantages over conventional molten salt receivers due to their ability to achieve temperatures above 700 ºC, direct absorption of solar energy as they fall through a beam of concentrated sunlight, and the relative ease of storage (and retrieval using a secondary working fluid) in insulated storage tanks. The use of particles, however, also raises concerns with material degradation from the flow of hot or cold particles through discharge hoppers or along the inner receiver surfaces and other system components (e.g. tubes, valves etc.), depending on operating mode of the receiver. The flow of particles over surfaces may result in loss of material from abrasive wear, impact erosion from impingement under gravitational fall and particle attrition as particles fall and move on top of each other. In the present study, the performance of candidate materials and particles were evaluated through a series of abrasion erosion and particle attrition experiments at room temperature as well as at 800 °C. Candidate materials were subject to abrasive wear from particles at low particle to material velocities inside a resistance heated kiln, and analyzed for changes in mass and surface morphology using cross-sectional scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS) tests. The wear rate for different specimens was noted to be largely driven by the strength of chromia scales built on the specimens from exposure to high temperature. Particle attrition measurements explored the susceptibility of particles to breakdown from particle to particle interaction and the generation of fines from this process. At the low velocities expected in particle based CSP plants, the particles tested exhibited near negligible breakdown. However, changes in the particle hardness at 800 ºC resulted in a significantly higher particle breakdown to sizes <40 microns raising potential environmental concerns. In addition to particle breakdown, it was also noted that the sample had oxides from the stainless steel test setup mixed in with the particles. Similar oxides can be expected to turn up in the utility scale particle based CSP plants as well. The presence of oxide was also noted to affect the solar absorptivity of the mixture compared to a clean initial specimen, potentially resulting in a change in the overall efficiency of the CSP plant.

14 SOLAR ENERGY↗

Unraveling Grain Boundary Instability in Dense Proton-Conducting Oxides

The long-term stability of protonic ceramic electrolysis cell (PCEC) materials under high-steam operating conditions remains a critical barrier to device commercialization. Here, we investigate the fundamental degradation mechanisms of dense BaCe 0.7 Zr 0.1 Y 0.1 Yb 0.1 O 3-δ (BCZYYb) electrolytes operated at 550 °C, 50% H 2 O in air. Over 1,000 h, the total electrolyte conductivity decreases by 11.1%, driven primarily by a >130% increase in grain-boundary resistivity. Post-mortem analyses reveal that damage is localized to near-surface grain boundaries extending ∼50 μm into the dense electrolyte pellet. This surface localization indicates that degradation is likely to be severe in thin, device-level electrolytes. Degradation is primarily attributed to chemo-mechanical grain-boundary weakening arising from hydration-induced chemical expansion, culminating in the formation of intergranular cracks oriented parallel to the pellet surface. These internal cracks subsequently react with steam and/or CO 2 , leading to the formation of nanoscale insulating phases, including Ba(OH) 2 , nanocrystalline BaCO 3 , and amorphous Ce/Zr/Y/Yb-containing oxides or hydroxycarbonates. After an initial degradation period of approximately 200 h, the overall conductivity stabilizes. Incorporating NiO sintering aids reduces grain-boundary density by an order of magnitude under identical sintering conditions. Although addition of NiO increases the initial resistivity by >160% at 550 °C, it substantially suppresses grain-boundary instability and mitigates chemical degradation. These findings underscore the urgent need for chemical and/or physical stabilization of BCZYYb electrolytes and offer design guidelines to enable durable, high-performance PCECs.

08 HYDROGEN↗

Photovoltaic Cable Connectors: A Comparative Assessment of the Present State of the Industry [Slides]

The consequences of failure for balance of systems (BoS) components (such as PV cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and over-temperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared to field-degraded specimens. 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens) including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross-section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier-transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components. Updated from 2023 NIST/UL Workshop on Photovoltaic Materials Durability (website: https://events.ul.com/WPMogn?rt=aAuoWsl4E0KaORLCMeOgfA) and 2024 PVRW workshop (https://pvrw.nrel.gov/past-proceedings).

14 SOLAR ENERGY↗

Hydrophobic Lightweight Cement with Thermal Shock Resistance and Thermal Insulating Properties for Energy-Storage Geothermal Well Systems

This study assessed the possibility of using polymethylhydrosiloxane (PMHS)-treated fly ash cenospheres (FCS) for formulating a thermally insulating and thermal shock (TS)-resistant cementitious blend with calcium aluminate cement. To prevent FCS degradation in an alkaline cement environment at high temperatures, the cenospheres were pre-treated with sodium metasilicate to form silanol and aluminol groups on their surface. These groups participated in a dehydrogenation reaction with the functional ≡Si–H groups within PMHS with the formation of siloxane oxygen-linked M-FCS (M: Al or Si). At high hydrothermal temperatures of 175 and 250 °C, some Si–O–Si and SiCH 3 bonds ruptured, causing depolymerization of the polymer at the FCS surface and hydroxylation of the raptured sites with the formation of silanol groups. Repolymerization through self-condensation between the silanol groups followed, resulting in the transformation of siloxane to low crosslinked silicon-like polymer as a repolymerization-induced product (RIP) without carbon. The RIP provided adequate protection of FCS from pozzolanic reactions (PR), which was confirmed by the decline in zeolites as the products of PR of FCS. Cements with PMHS-treated FCS withstood both hydrothermal and thermal temperature of 250 °C in TS tests, and they also showed improved compressive strength, toughness, and water repellency as well as decreased thermal conductivity. The lubricating properties of PMHS increased the fluidity of lightweight slurries.

15 GEOTHERMAL ENERGY↗

Characterizing photovoltaic backsheet adhesion degradation using the wedge and single cantilever beam tests, Part II: Accelerated tests

Photovoltaic (PV) backsheets provide critical moisture, mechanical, and electrical insulation to the backside of PV modules, but their continued functionality depends upon their ability to remain well adhered over years of harsh environmental exposure. A study of adhesive strength was conducted on several PV backsheet types exposed to indoor accelerated weathering. Two adhesion tests – the wedge test and single cantilever beam test – were used to measure adhesion energy in four backsheets: two with fluoropolymer-based outer (airside) layers – polyvinyl fluoride (PVF), polyvinylidene fluoride (PVDF) – and two with non-fluoropolymer-based outer layers–polyamide (PA) and polyethylene terephthalate (PET). The effects of changes in temperature, ultraviolet (UV) irradiance, relative humidity, and a periodic water spray were studied. The PET-, PVF- and PVDF-based backsheets all showed instances of debonding in an adhesive layer, which is commonly reported. Furthermore, for the PA-, PET-, and PVDF-based backsheets, adhesion energy dropped fairly rapidly with exposure, reaching very low levels by 4000 h. The PVF-based backsheet was relatively robust to weathering. Pull-off of an outer chalking layer in the PA- and PET-based backsheets suggested a sensitivity to UV. Adhesion in these two backsheets was also highly sensitive to changes in moisture level. Changes in UV irradiance and temperature did not show a statistically significant effect on adhesion loss for the exposure levels used. The present work is part of a two-part adhesion study on both field-weathered and indoor-exposed backsheets, and forms a basis for understanding adhesion degradation across a variety of backsheet types and degradation factors.

14 SOLAR ENERGY↗

PV backsheets survey protocol: A framework for geo-spatial field surveys for bulk material characterization and reliability analysis applied across 41 PV systems

As widespread adoption of photovoltaic (PV) technologies continues, understanding the lifetime of modules is paramount to the viability of the industry as an environmentally conscious alternative to traditional energy generation. Although power degradation can affect the total energy production of a module over its lifetime, module safety failures necessitate the removal of a module leading to a loss of not only the particular asset, but the earning potential of the device. Therefore, it is critical to ensure that the components that provide essential safety functions for PV module operate for their entire rated lifetime. PV backsheets provide necessary electrical insulation to the completed device and failure of this component is cause for a immediate removal of the module. Degradation of the PV module backsheet has led to module safety failures in large-scale installations, costing millions of dollars in damages and lost potential revenue. The spatio-temporal degradation of fielded PV modules is important to study in order to identify which modules within installations are experiencing the greatest exposure conditions and in turn have the highest chance of failure. This paper describes a comprehensive field survey protocol developed for monitoring PV module backsheet performance using solely non-destructive methods in commercial PV fields. The protocol establishes a field naming convention, sampling method, data handling requirements, and measurement procedures. By ensuring consistent data collection practices, the field survey protocol enables research groups to obtain data of uniform quality on backsheet performance over multiple years and locations. In this study, the developed protocol was implemented at forty-one PV sites. Eight different types of airside layer backsheet materials including poly(vinylidene fluoride) (PVDF), acrylic PVDF, poly(tetrafluoroethylene-co-hexafluoropropylene-co-vinylidene fluoride) (THV), poly(vinyl fluoride) (PVF), poly(ethylene terephthalate) (PET), fluoroethylene vinyl ether (FEVE), polyethylene naphthalate (PEN), and glass were identified using attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. The field survey results show that the spatial distribution of degradation indicators are non-uniform within a particular module, individual site, and across site locations. The degradation of PV modules increased in severity for modules mounted at the edge of rows (across a field) and near the junction box (within a module). This study demonstrates the sensitivity of material performance to exposure length across different materials and climates.

14 SOLAR ENERGY↗