The charge spectrum of positive ions in a hydrogen aurora

An auroral ion charge spectrometer was flown into a hydrogen aurora on a Javelin sounding rocket launched from Churchill, Manitoba. The instrument contained an electrostatic analyzer which selected particles with incident energy per unit charge up to 20 keV/charge and an 80-kV power supply which accelerated these ions onto an array of solid state detectors. Ions tentatively identified as H(+), He(+2), and O(+) were detected from 225 to 820 km in altitude. The experiment did not discriminate between H(+) and He(+), or between O(+), N(+), and C(+). Upper limits of highly charged heavy ion abundances have been set at 20% of the He(+2) and 0.15% of the H(+). It is concluded that both terrestrial and solar wind sources play significant roles in auroral ion precipitation.

Lynch, J.↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatilizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vilicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Kuppermann, Aron↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vidicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Boettger, Heinz G.↗

Transport, charge exchange and loss of energetic heavy ions in the earth's radiation belts - Applicability and limitations of theory

Computer simulations of processes which control the relative abundances of ions in the trapping regions of geospace are compared with observations from discriminating ion detectors. Energy losses due to Coulomb collisions between ions and exospheric neutrals are considered, along with charge exchange losses and internal charge exchanges. The time evolution of energetic ion fluxes of equatorially mirroring ions under radial diffusion is modelled to include geomagnetic and geoelectric fluctutations. Limits to the validity of diffusion transport theory are discussed, and the simulation is noted to contain provisions for six ionic charge states and the source effect on the radiation belt oxygen ion distributions. Comparisons are made with ion flux data gathered on Explorer 45 and ISEE-1 spacecraft and results indicate that internal charge exchanges cause the radiation belt ion charge state to be independent of source charge rate characteristics, and relative charge state distribution is independent of the radially diffusive transport rate below the charge state redistribution zone.

Spjeldvik, W. N.↗

Ion implanted photodiode detectors in epitaxial /Ga/x/In/1-x//As

Ion implanted p-n junction photodiodes in epitaxially grown (Ga(x)In(1-x))As material are reported on here. Photoresponse in these diodes was investigated for approximately the entire composition range of x between zero and one. High values for quantum efficiency were obtained for the devices with a high value of x.

Ajmera, P. K.↗

The role of fiber optics in mass spectrometer electro-optical ion detection

This paper describes the development of an electro-optical ion detector combining the best features of photographic and electrical ion detection (i.e., wide mass range coverage and low ion detection threshold respectively). A nineteen fold fiber optic image dissector is discussed which reformats the 1 mm x 361 mm mass spectrometer focal plane format to a 19 mm x 19 mm format suitable for vidicon imaging and electronic display of the data.

Norris, D. D.↗

Observations of ions with nuclear charge Z greater than or equal to 9 in the inner magnetosphere

The Explorer 45 heavy ion data analysis is extended to ions heavier than fluorine, that is, ions with nuclear charge Z greater than about 9 during and after a major magnetic storm on August 4, 1972. Although the heavy ion detector telescope does not permit a precise identification of these ions, it is pointed out that if they are, for example, magnesium ions, then an equatorially mirroring peak trapped flux of 0.02 ions/sq cm-s-sr-keV is derived on L shells just below L = 3 at energies 12.8-51.2 MeV per ion (533-2133 keV per nucleon). It is noted that other possible ion contributions include silicon and iron. The fluxes of these ions are found to decay on time scales typically several tens of days; this is substantially faster than that of helium ions and slightly faster than that of oxygen ions in the lower MeV range.

Spjeldvik, W. N.↗

Bioregenerative life support systems for microgravity

NASA's Controlled Ecological Life Support System (CELSS) project centers on growing plants and recycling wastes in space. The current version of the biomass production chamber (BPC) uses a hydroponic system for nutrient delivery. To optimize plant growth and conserve system resources, the content of the nutrient solution which feeds the plants must be constantly monitored. The macro-nutrients (greater than ten ppm) in the solution include nitrogen, phosphorous, potassium, calcium, magnesium, and sulphur; the micro-nutrients (less than ten ppm) include iron, copper, manganese, zinc, and boron. The goal of this project is to construct a computer-controlled system of ion detectors that will accurately measure the concentrations of several necessary ions in solution. The project focuses on the use of a sensor array to eliminate problems of interference and temperature dependence.

Nevill, Gail E., Jr.↗

Transport of terrestrial atmospheric gases to the moon

The suprathermal Ion Detector Experiment instruments on the lunar surface have identified fluxes of ions which may be different from the solar wind both in elemental and in isotopic abundances. At present, only O/+/ is (tentatively) identified, but the mechanism operates to produce ions at the moon which have their origin in the earth's atmosphere. Consequently, the 'solar wind' component of the surface-correlated gases is effectively a combination of terrestrial atmospheric ions and the actual solar wind. The results differ from solar wind results if the terrestrial ion abundances strongly differ from those of the solar wind.

Hills, H. K.↗

Observations of water vapor ions at the lunar surface.

The Apollo 14 Suprathermal Ion Detector Experiment observed a series of bursts of 48.6 eV water vapor ions at the lunar surface during a 14-hr period on Mar. 7, 1971. The maximum flux observed was 100 million ions per sq cm per sec per sr. These ions were also observed at Apollo 12, 183 km to the west. Evaluation of specific artificial sources including the Apollo missions and the Russian Lunokhod leads to the conclusion that the water vapor did not come from a man-made source. Natural sources exogenous to the moon such as comets and the solar wind are also found to be inadequate to explain the observed fluxes. Consequently, these water vapor ions appear to be of lunar origin.-

Freeman, J. W., Jr.↗

The interaction between an impact-produced neutral gas cloud and the solar wind at the lunar surface

On Apr. 15, 1970, the Apollo 13 S-IVB stage impacted the nighttime lunar surface. Beginning 20 sec after impact, the Suprathermal Ion Detector Experiment and the Solar Wind Spectrometer observed a large flux of positive ions (maximum flux of about 3 x 10 to the 8th ions/sq cm/sec/ster) and electrons. Two separate streams of ions were observed: a horizontal flux that appeared to be deflected solar wind ions and a smaller vertical flux of predominantly heavy ions (greater than 10 amu), which probably were material vaporized from the S-IVB stage. An examination of the data shows that collisions between neutral molecules and hot electrons (50 eV) were probably an important ionization mechanism in the impact-produced neutral gas cloud. These electrons, which were detected by the Solar Wind Spectrometer, are thought to have been energized in a shock front or some form of intense interaction region between the cloud and the solar wind. Thus strong ionization and acceleration are seen under conditions approaching a collisionless state.

Lindeman, R. A.↗

Double-peaked ion spectra in the lobe plasma - Evidence for massive ions

Suprathermal Ion Detector Experiments (SIDE) have suggested the presence of a significant secondary peak in the ion distribution function during geomagnetic active periods when the moon is within the lobe plasma. It is observed that: (1) an increase in the primary peak bulk velocity is reflected in an increase in secondary peak bulk velocity, (2) both spectra are narrow in the instrument-look direction (assumed parallel to the flow) and peak temperatures are usually less than about 10 eV, (3) periods for double peak observations comprise about 10% of the total lobe plasma observation time, (4) assuming that peaks are caused by protons, and without correcting for lunar surface potential, primary peak bulk velocity is between about 70 and 160 km/s, and secondary peak bulk velocity is between about 360 and 840 km/s, and (5) assuming equal flow velocities outside the influence of the lunar surface potential are equal for the ions of the two peaks, and making corrections for this potential, secondary peak ions are consistent with N(+) or O(+), and the ratio of O(+) to proton number densities is usually less than about 2 x 10 to the -3rd.

Hardy, D. A.↗

The Apollo lunar surface water vapor event revisited

On March 7, 1971, the first sunrise following the Apollo 14 mission, the Suprathermal Ion Detector Experiment (SIDE) deployed at the Apollo 14 site reported an intense flux of ions whose mass per charge was consistent with water vapor. The amount of water is examined, and the various acceleration processes, responsible for accelerating ions into the SIDE, are discussed. It is concluded that during most of the event the observed water vapor ions were accelerated by the negative lunar surface electric potential and, secondly, that this event was probably the result of mission associated water vapor, either from the LM ascent and descent stage rockets or from residual water in the descent stage tanks.

Freeman, J. W., Jr.↗

The lunar terminator ionosphere

The extended ionosphere is seen by the Suprathermal Ion Detector Experiments (SIDE) near the terminator. An analysis of the energy and mass spectra of these ions accelerated by the interplanetary electric field indicates the following: (1) the principal ion species are in the mass per unit charge ranges consistent with neon and argon, (20-28 and 40-44 amu/q); (2) the lunar atmosphere in these mass ranges is distributed exponentially; (3) the terminator region surface number density for Ne-20 is of the order of 10 to the 5th/cu cm; (4) the terminator region lunar surface potential is negative from about 10 to 100 volts; and (5) this potential has a screening length of the order of a kilometer.

Benson, J.↗

Quiet time observations of equatorially trapped megaelectronvolt radiation belt ions with nuclear charge Z greater than or equal to 4

Data from the equatorial satellite Explorer 45 were used to study ion fluxes during the geomagnetically quiescent period June 1-15, 1972. A heavy-ion solid-state ion detector system obtained count rates close to the equatorial plane in the energy passband 1.82-4.8 MeV per ion during a single satellite pass through the radiation belts. Fluxes of these ions are interpreted as oxygen ions and are found to maximize in the L shell range 3-3.5 with peak equatorially mirroring flux of 0.38 ions/(sq cm s sr keV). This peak is not as sharply confined in L shell as is the helium ion peak.

Spjeldvik, W. N.↗

The Lunar Potential Determination Using Apollo-Era Data and Modern Measurements and Models

Since the Apollo era the electric potential of the Moon has been a subject of interest and debate. Deployed by three Apollo missions, Apollo 12, Apollo 14 and Apollo 15, the Suprathermal Ion Detector Experiment (SIDE) determined the sunlit lunar surface potential to be about +10 Volts using the energy spectra of lunar ionospheric thermal ions accelerated toward the Moon. More recently, the Lunar Prospector (LP) Electron Reflectometer used electron distributions to infer negative lunar surface potentials, primarily in shadow. We will present initial results from a study to combine lunar surface potential measurements from both SIDE and the LP/Electron Reflectometer to calibrate an advanced model of lunar surface charging which includes effects from the plasma environment, photoemission, secondaries ejected by ion impact onto the lunar surface, and the lunar wake created downstream by the solar wind-lunar interaction.

Collier, Michael R.↗

Lunar Surface Potential Increases during Terrestrial Bow Shock Traversals

Since the Apollo era the electric potential of the Moon has been a subject of interest and debate. Deployed by three Apollo missions, Apollo 12, Apollo 14 and Apollo 15, the Suprathermal Ion Detector Experiment (SIDE) determined the sunlit lunar surface potential to be about +10 Volts using the energy spectra of lunar ionospheric thermal ions accelerated toward the Moon. We present an analysis of Apollo 14 SIDE "resonance" events that indicate the lunar surface potential increases when the Moon traverses the dawn bow shock. By analyzing Wind spacecraft crossings of the terrestrial bow shock at approximately this location and employing current balancing models of the lunar surface, we suggest causes for the increasing potential. Determining the origin of this phenomenon will improve our ability to predict the lunar surface potential in support of human exploration as well as provide models for the behavior of other airless bodies when they traverse similar features such as interplanetary shocks, both of which are goals of the NASA Lunar Science Institute's Dynamic Response of the Environment At the Moon (DREAM) team.

Collier, Michael R.↗