Search NASA⌕ Search

SEARCH · Search NASA

Results for “LABORATORY EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A versatile facility for laboratory studies of viscoelastic and poroelastic behaviour of rocks

Novel laboratory equipment has been modified to allow both torsional and flexural oscillation measurements at sub-microstrain amplitudes, thereby providing seismic-frequency constraints on both the shear and compressional wave properties of cylindrical rock specimens within the linear regime. The new flexural mode capability has been tested on experimental assemblies containing fused silica control specimens. Close consistency between the experimental data and the results of numerical modelling with both finite-difference and finite-element methods demonstrates the viability of the new technique. The capability to perform such measurements under conditions of independently controlled confining and pore-fluid pressure, with emerging strategies for distinguishing between local (squirt) and global (specimen-wide) fluid flow, will have particular application to the study of frequency-dependent seismic properties expected of cracked and fluid-saturated rocks of the Earth's upper crust.

42 ENGINEERING↗

Radiometric characterization process for locating radioactivity hold-up and measuring non-uniformly distributed sources - 15342

A novel approach to facility radiometric characterization for non-uniformly distributed radiation sources has been developed by ANTECH and is currently being employed at the Argonne National Laboratory. It is being applied to the measurement of a wide range of objects and the interiors and contents of laboratories and buildings. The integrated non destructive assay measurement process involves the use of a scanning spectroscopic gamma ray camera as well as high purity Germanium detectors with different collimators and hence differing detector fields of view to measure and quantify non-uniformly distributed sources of radioactivity in laboratory equipment, glove boxes, storage tanks, pipework and general laboratory objects and process components. The purpose of the radiometric characterization is to quantify radiation sources and radioactive contamination levels in facilities containing nuclear material and to ensure compliance with facility characterization requirements and for decontamination and decommissioning planning and execution. The integrated measurement process also involves automated data capture and processing software and a database with which both measurement instrument operators and subject matter expert analysts can interact. An appropriate measuring instrument (gamma camera, scintillation detector, high purity Germanium detector system, neutron detector or alpha-beta counter) records the measurement data and the measurement site is recorded in a photograph. All of the data relevant to the measurement (or set of measurements for a particular object) are recorded in the database including measured gamma ray spectra, equipment description and relevant calibration, measurement site photograph and measurement descriptive data. Once data analysis protocols are established for specific geometries and measurement situations they can be applied to the measured data in a partially automated manner, reducing analysis and transcription errors. In addition to measurements and data analysis the process also utilises radiometric modelling computer codes including MicroShield and Monte Carlo Neutrons Photons in order to perform model calculations where appropriate. In a typical measurement, the ANTECH RadSearch spectroscopic gamma camera is utilized to find areas of concentrated activity so that these areas can be measured and calculated separately from areas with diffuse contamination. The use of the gamma camera in scanning mode helps to ensure that the assay does not overestimate the detected radiation source, which is a frequent consequence of using standard far field geometry and attenuation analysis codes that assume uniformity of both density and radioactive source distribution. Once the hot spots are identified, high purity Germanium detector measurements are made using various collimators with wide or narrow fields of view as required. These measurements are then processed through a semi-automatic calculation process assuming an appropriate source configuration as identified by RadSearch. These source configurations include point sources, line sources or surface sources. The Generalized Geometry Hold-up algorithms are employed to determine an estimate of the activity of the various sources that are identified in a measurement. The ANTECH integrated measurement process provides an automated calculation procedure where the analyst can select the source type, geometry and appropriate input data, and then the software calculates the activity by radionuclide for all sources identified in the measurement. The measurement and analysis process is controlled under the ANTECH ISO9001: 2008 Quality Assurance System and managed by a site specific Quality Assurance Plan. Both Argonne National Laboratory and Department of Energy technical reviewers have vetted the Integrated Measurement and Analysis Process. The application of the measurement and analysis process is described and measurement examples are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Equipment concept design and development plans for microgravity science and applications research on space station: Combustion tunnel, laser diagnostic system, advanced modular furnace, integrated electronics laboratory

Taking advantage of the microgravity environment of space NASA has initiated the preliminary design of a permanently manned space station that will support technological advances in process science and stimulate the development of new and improved materials having applications across the commercial spectrum. Previous studies have been performed to define from the researcher's perspective, the requirements for laboratory equipment to accommodate microgravity experiments on the space station. Functional requirements for the identified experimental apparatus and support equipment were determined. From these hardware requirements, several items were selected for concept designs and subsequent formulation of development plans. This report documents the concept designs and development plans for two items of experiment apparatus - the Combustion Tunnel and the Advanced Modular Furnace, and two items of support equipment the Laser Diagnostic System and the Integrated Electronics Laboratory. For each concept design, key technology developments were identified that are required to enable or enhance the development of the respective hardware.

Uhran, M. L.↗

Building a Simplistic Automatic Extruder: Instrument Development Opportunities for the Laboratory

This work presents an automatic extruder as a research experience for undergraduate students. The system offers a user-friendly approach to preparing vesicles, such as liposomes or polymersomes, with a defined size and polydispersity properties crucial for research in biology and macromolecules. It comprises two syringe pumps connected by a membrane filter. The setup is controlled by software. Compared to manual extrusion, this automated system provides advantages, such as precisely controlled variables. The project describes a tool to enhance undergraduate learning in science and engineering laboratories. Building an automatic extruder serves as a simplified model of a complex industrial process. It offers a clear advantage: automating a well-understood manual extrusion process. To make this project accessible, it is broken down into three manageable tasks: software development, hardware assembly, and testing procedures. This breakdown describes the software created, the hardware components used, and the testing procedures conducted for this project. All project data, including software code, testing data, and procedures, are freely available online. This allows undergraduate students to not only begin their own projects but also contribute to this educational instrument’s ongoing development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanostructured Magnetic Materials (Final Technical Progress Report)

This report describes progress made during the final phase of our DOE-funded program on Nanostructured Magnetic Materials. This period was quite productive, resulting in the submission of three papers and presentation of three talks at international conferences and three seminars at research institutions. Our DOE-funded research efforts were directed toward studies of magnetism at surfaces and interfaces in high-quality, well-characterized materials prepared by Molecular Beam Epitaxy (MBE) and sputtering. We have an exceptionally well-equipped laboratory for these studies, with: Thin film preparation equipment; Characterization equipment; Equipment to study magnetic properties of surfaces and ultra-thin magnetic films and interfaces in multi-layers and superlattices.

36 MATERIALS SCIENCE↗

Connecticut State University System Initiative for Nanotechnology-Related Equipment, Faculty Development and Curriculum Development

DOE grant used for partial fulfillment of necessary laboratory equipment for course enrichment and new graduate programs in nanotechnology at the four institutions of the Connecticut State University System (CSUS). Equipment in this initial phase included variable pressure scanning electron microscope with energy dispersive x-ray spectroscopy elemental analysis capability [at Southern Connecticut State University]; power x-ray diffractometer [at Central Connecticut State University]; a spectrophotometer and spectrofluorimeter [at Eastern Connecticut State University; and a Raman Spectrometer [at Western Connecticut State University]. DOE's funding was allocated for purchase and installation of this scientific equipment and instrumentation. Subsequently, DOE funding was allocated to fund the curriculum, faculty development and travel necessary to continue development and implementation of the System's Graduate Certificate in Nanotechnology (GCNT) program and the ConnSCU Nanotechnology Center (ConnSCU-NC) at Southern Connecticut State University. All of the established outcomes have been successfully achieved. The courses and structure of the GCNT program have been determined and the program will be completely implemented in the fall of 2013. The instrumentation has been purchased, installed and has been utilized at each campus for the implementation of the nanotechnology courses, CSUS GCNT and the ConnSCU-NC. Additional outcomes for this grant include curriculum development for non-majors as well as faculty and student research.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Short communication: Mechanism and prevention of irreversible trapping of atmospheric He during mineral crushing

A pervasive challenge in noble gas geochemistry is to ensure that analytical techniques do not modify the composition of the noble gases in the samples. Noble gases are present in the atmosphere and are used in a number of manufacturing procedures and by laboratory equipment. Of particular concern is the introduction of atmospheric or laboratory noble gases to samples during preparation before samples are placed in a vacuum chamber for analysis. Recent work has shown the potential for contamination of crushed samples with air-derived He that is not released by placing the samples under vacuum at room temperature. Using pure He gas as a tracer, we show that the act of crushing samples to a fine powder itself can introduce He contamination but that this is easily avoided by crushing under liquid or in an inert atmosphere. Because the He is trapped during crushing, the same concern does not extend to samples that are naturally fine-grained when collected. We also show model results that demonstrate when this effect might significantly impact samples for (U–Th) / He geochronology or 3 He cosmogenic nuclide dating. The degree of He contamination from crushing samples to sizes smaller than the > 63 µm range typically used for geochronology is insignificant for samples with a date of at least 1 Ma and 1 ppm U, and the degree of He contamination from crushing samples to sizes smaller than the 100–500 µm range typically used for cosmogenic nuclide dating is also insignificant for samples with a date of at least 10 ka with typical 3 He production rates.

58 GEOSCIENCES↗

System design considerations for free-fall materials processing

The design constraints for orbiting materials processing systems are dominated by the limitations of the flight vehicle/crew and not by the processes themselves. Although weight, size and power consumption are all factors in the design of normal laboratory equipment, their importance is increased orders of magnitude when the equipment must be used in an orbital facility. As a result, equipment intended for space flight may have little resemblance to normal laboratory apparatus although the function to be performed may be identical. The same considerations influence the design of the experiment itself. The processing requirements must be carefully understood in terms of basic physical parameters rather than defined in terms of equipment operation. Preliminary experiments and analysis are much more vital to the design of a space experiment than they are on earth where iterative development is relatively easy. Examples of these various considerations are illustrated with examples from the M518 and MA-010 systems. While these are specific systems, the conclusions apply to the design of flight materials processing systems both present and future.

Seidensticker, R. G.↗

Miniature Time-of-Flight Mass Spectrometer

Major advances must occur to protect astronauts from prolonged periods in near-zero gravity and high radiation associated with extended space travel. The dangers of living in space must be thoroughly understood and methods developed to reverse those effects that cannot be avoided. Six of the seven research teams established by the National Space Biomedical Research Institute (NSBRI) are studying biomedical factors for prolonged space travel to deliver effective countermeasures. To develop effective countermeasures, each of these teams require identification of and quantitation of complex pharmacological, hormonal, and growth factor compounds (biomarkers) in humans and in experimental animals to develop an in-depth knowledge of the physiological changes associated with space travel. At present, identification of each biomarker requires a separate protocol. Many of these procedures are complicated and the identification of each biomarker requires a separate protocol and associated laboratory equipment. To carry all of this equipment and chemicals on a spacecraft would require a complex clinical laboratory; and it would occupy much of the astronauts time. What is needed is a small, efficient, broadband medical diagnostic instrument to rapidly identify important biomarkers for human space exploration. The Miniature Time-Of- Flight Mass Spectrometer Project in the Technology Development Team is developing a small, high resolution, time-of-flight mass spectrometer (TOFMS) to quantitatively measure biomarkers for human space exploration. Virtues of the JHU/APL TOFMS technologies reside in the promise for a small (less than one cubic ft), lightweight (less than 5 kg), low-power (less than 50 watts), rugged device that can be used continuously with advanced signal processing diagnostics. To date, the JHU/APL program has demonstrated mass capability from under 100 to beyond 10,000 atomic mass units (amu) in a very small, low power prototype for biological analysis. Further, the electronic nature of the TOFMS output makes it ideal for rapid telemetry to earth for in-depth analysis by ground support teams.

Potember, Richard S.↗

Washington State Biofuels Industry Development

The funding from this research grant enabled us to design, renovate, and equip laboratories to support University of Washington biofuels research program. The research that is being done with the equipment from this grant will facilitate the establishment of a biofuels industry in the Pacific Northwest and enable the University of Washington to launch a substantial biofuels and bio-based product research program.

09 BIOMASS FUELS↗

Analysis of commercial equipment and instrumentation for Spacelab payloads, volume 2

Technical results are presented of a study to investigate analytically the feasibility of using commercially available laboratory equipment and instrumentation in the spacelab in support of various experiments. The feasibility is demonstrated by the breadth of application of commercial, airborne, and military equipment to experiment equipment requirements in the spacelab, and the cost effectiveness of utilizing this class of equipment instead of custom-built aerospace equipment typical of past designs. Equipment design and specifications are discussed.

Source record↗

Rapid Detection of the Varicella Zoster Virus

1.Technology Description-Researchers discovered that when the Varicella Zoster Virus (VZV) reactivates from latency in the body, the virus is consistently present in saliva before the appearance of skin lesions. A small saliva sample is mixed with a specialized reagent in a test kit. If the virus is present in the saliva sample, the mixture turns a red color. The sensitivity and specificity emanates from an antibody-antigen reaction. This technology is a rapid, non-invasive, point of-of-care testing kit for detecting the virus from a saliva sample. The device is easy to use and can be used in clinics and in remote locations to quickly detect VZV and begin treatment with antiviral drugs. 2.Market Opportunity- RST Bioscience will be the first and only company to market a rapid, same day test kit for the detection of VZV in saliva. The RST detection test kit will have several advantages over existing, competitive technology. The test kit is self contained and laboratory equipment is not required for analysis of the sample. Only a single saliva sample is required to be taken instead of blood or cerebral spinal fluid. The test kit is portable, sterile and disposable after use. RST detection test kits require no electrical power or expensive storage equipment and can be used in remote locations. 3.Market Analysis- According to the CDC, it is estimated that 1 million cases of shingles occur each year in the U.S. with more than half over the age of sixty. There is a high demand for rapid diagnostics by the public. The point-of-care testing (POCT) market is growing faster than other segments of in vitro diagnostics. According to a July 2007 InteLab Corporation industry report the overall market for POCT was forecast to increase from $10.3 billion in 2005 to $18.7 billion by 2011. The market value of this test kit has not been determined. 4.Competition- The VZV vaccine prevents 50% of cases and reduces neuralgia by 66%. The most popular test detects VZV-specific IgM antibody in blood. Other tests include running a sample in a polymerase chain reaction analyzer, enzyme immunoassay, latex agglutination, indirect fluorescent antibody and fluorescent antibody to membrane antigen assay. These existing tests require laboratory analysis by trained personnel, expensive equipment, invasive procedures and a longer period of time to obtain test results.

Lewis, Michelle P.↗

In-flight medical support system

The In-flight Medical Support System for Skylab was designed to provide the onboard Crew Physician or Scientist Pilot (or other crewmember if the Scientist Pilot was unable to act) with information adequate to make diagnostic assessment of those injuries or illnesses most likely to occur in the Skylab environment. The necessary diagnostic, therapeutic, and laboratory equipment needed to diagnose and to render first aid, resuscitative or supportive measures was stored in the Skylab Orbital Workshop. The resupply kit containing refrigerated laboratory and drug resupply items was stored in the Command Module.

Chassay, C.↗

Spacelab 2

The most promising new technology for scientific research is America's Space Transportation System; the space shuttle and its companion facility, Spacelab. Spacelab is a versatile laboratory designed specifically to accommodate scientists and their instruments in low-Earth orbit. In a space laboratory, scientists can perform experiments that are impossible on Earth. They can also use very large instruments aboard the Shuttle, with the added benefit of bringing all their equipment, experiment samples, and data home for analysis. Spacelab 2 is one in a series of missions that gives the world's scientists a chance to do research in a well-equipped laboratory in space.

Source record↗

Simple separation of technetium from molybdenum for tracer isotope production

A procedure for the separation of technetium isotopes from bulk molybdenum was developed in nitric acid media. After irradiation of nat Mo foils, and dissolution in H 2 O 2 , the solution is acidified to 2 M HNO 3 , and anion exchange resin is used to separate technetium from molybdenum. The procedure is simple, requiring only basic laboratory equipment and, with a two-column separation, the technetium yield is high (~ 85%) with extremely high purity (< 0.1 ppm nat Mo). In conclusion, this is ideally suited for laboratory production of technetium tracer isotopes, particularly 95m Tc.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

LABORATORY AND ASTRONOMICAL DISCOVERY OF HYDROMAGNESIUM ISOCYANIDE

We report on the detection of hydromagnesium isocyanide, HMgNC, in the laboratory and in the carbon-rich evolved star IRC+10216. The J = 1-0 and J = 2-1 lines were observed in our microwave laboratory equipment in Valladolid with a spectral accuracy of 3 KHz. The hyperfine structure produced by the nitrogen atom was resolved for both transitions. The derived rotational constants from the laboratory data are B{sub 0} = 5481.4333(6) MHz, D{sub 0} = 2.90(8) KHz, and eQq(N) = –2.200(2) MHz. The predicted frequencies for the rotational transitions of HMgNC in the millimeter domain have an accuracy of 0.2-0.7 MHz. Four rotational lines of this species, J = 8-7, J = 10-9, J = 12-11, and J = 13-12, have been detected toward IRC+10216. The differences between observed and calculated frequencies are <0.5 MHz. The rotational constants derived from space frequencies are B{sub 0} = 5481.49(3) MHz and D{sub 0} = 3.2(1) KHz, i.e., identical to the laboratory ones. A merged fit to the laboratory and space frequencies provides B{sub 0} = 5481.4336(4) MHz and D{sub 0} = 2.94(5) KHz. We have derived a column density for HMgNC of (6 ± 2) × 10{sup 11} cm{sup –2}. From the observed line profiles the molecules have to be produced in the layer where other metal-isocyanides have been already found in this source. The abundance ratio between MgNC and its hydrogenated variety, HMgNC, is ≅20.

79 ASTRONOMY AND ASTROPHYSICS↗