Understanding and Enhancing Spallation Targets at LANSCE
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
This report summarizes the performance limits of the LANSCE Coupled-Cavity Linac (CCL). These results are captured or summarized directly from the references cited. This report was written in support of the LANSCE Modernization Project (LAMP). This brief report summarizes the emittance budget for the LANSCE Modernization Project (LAMP). While the project Key Performance Parameters (KPPs) specify threshold and objective requirements for charge delivered to each experimental area, no upper limits on beam emittances are specified. To maintain low losses in the high-energy section of the LANSCE linac and hands-on maintenance, some upper limits on beam emittance need to be specified for the new LAMP front-end performance. The scope of the LAMP project replaces the injector section and drift-tube linac (DTL) up to 100 MeV of the existing LANSCE linac. This new design replacement will be integrated with the remaining coupled cavity linac (CCL) which makes up most of the accelerator at LANSCE and accelerates the beam to a final energy of 800 MeV. The initial approach that has been used to define an emittance budget for the new LAMP front end is based on recent and historical measured beam emittances at 100 MeV for the three beam types accelerated at LANSCE: H+ (protons for isotope production), LBEG (H- beam for delivery to proton radiography and to the Lujan neutron spallation target, and MPEG (H- beam for delivery to the Weapons Neutron Research facility). The emittance budget (upper limit) for each beam type has been selected to maintain the losses in the CCL to a level approximately equivalent to those observed in present operations to first order. However, the goal of the LAMP project is to improve the quality of the beams injected into the CCL, if possible, thus allowing for higher average current operation while also lowering beam losses and activation at high beam energies. The table below summarizes the beam measurements evaluated and used to establish a conservative emittance budget for LAMP based on known historical beam losses and activation. However, based on estimates of the CCL admittance and the Isotope Production Facility (IPF) beamline acceptance, a more relaxed transverse emittance upper limit of 0.095 π-cm-mrad, rms, normalized may be acceptable at 100 MeV while still meeting the LAMP performance requirements for charge delivery to each LANSCE experimental area and maintaining hands-on maintenance. This upper limit is supported by a recent analysis of operational data. Additionally, the present conceptual LAMP front-end design meets this requirement.
The Los Alamos Neutron Science Center (LANSCE) is located at Technical Area 53 (TA-53) at Los Alamos National Laboratory (LANL) in Los Alamos, New Mexico. LANSCE is driven by an 800 megaelectronvolt (MeV) proton accelerator that delivered its first beam in 1972. The LANSCE accelerator is unique in that it accelerates both H– (to full energy of 800 MeV) and H+ ions (up to 100 MeV currently but has accelerated high-power H+ beam to 800 MeV in the past) and supports five separate experimental areas that operate simultaneously, with each having different timing and beam current requirements. Many of the LANSCE accelerator front-end components date back to original commissioning in 1972, including the ion sources, Cockcroft-Walton (CW) generators, and the Drift Tube LINAC (DTL), which accelerates the beam up to 100 MeV.
In this paper, we propose an experiment, LANSCE-mQ, aiming to detect fractionally charged and millicharged particles (mCPs) using an 800 MeV proton beam fixed target at the Los Alamos Neutron Science Center (LANSCE) facility at Los Alamos National Laboratory. This search can shed new light on numerous fundamental questions, including charge quantization, the predictions of string theories and grand unification theories, the gauge symmetry of the Standard Model, dark sector models, and the tests of cosmic reheating. We propose to install two-layer scintillation detectors made of plastic (such as EJ-200) or CeBr 3 to search for mCPs. Dedicated geant4 detector simulations and in situ measurements have been conducted to obtain a preliminary determination of the background rate. The dominant backgrounds are beam-induced neutrons and coincident dark current signals from the photomultiplier tubes, while beam-induced high-energy photons ( γ ’s) and cosmic muons are subdominant. We determined that LANSCE-mQ, the dedicated mCP experiment, has the leading mCP sensitivity for mass between ∼ 1 and 300 MeV.
We discuss here the possibility of using the Isotope Production Facility (IPF) at LANSCE to test the feasibility and performance of a graphite cube to create a neutron target. The idea of a neutron target enables the measurement of neutron induced reactions in inverse kinematics. This idea is part of the LANSCE strategy to stay a worldwide leader for neutron-induced research. The proof of-principle is the core of the LDRD project 20240004DR. The first steps are a series of activation experiments with different neutron energy distributions. Figs. 1 and 2 show a graphite cube built and simulated from pieces available at LANSCE. First activation experiments have already been performed at lower neutron energies utilizing (p,n) reactions on Li and Be.
The Los Alamos Neutron Science Center (LANSCE) is located at Technical Area 53 (TA-53) at Los Alamos National Laboratory in Los Alamos, New Mexico. LANSCE is driven by an 800 mega electron volt (MeV) proton accelerator that delivered first beam in 1972. The LANSCE accelerator is unique in that it accelerates both H- (to full energy of 800 MeV) and H+ ions (up to 100 MeV currently but has accelerated high-power H+ beam to 800 MeV in the past) and supports five separate experimental areas that operate simultaneously with each having different timing and beam current requirements.
High-energy secondary neutrons, produced by the interaction of galactic cosmic rays (GCR) with the atmosphere, spacecraft structure and planetary surfaces, contribute a significant fraction to the dose equivalent radiation measurement in crew members and passengers of commercial aviation travel as well as astronauts in space missions. The Los Alamos Nuclear Science Center (LANSCE) neutron facility's 30L beam line (4FP30L-A/ICE House) is known to generate neutrons that simulate the secondary neutron spectrum of the Earth's atmosphere at high altitude. The neutron spectrum is also similar to that measured onboard spacecrafts like the MIR and the International Space Station (ISS). To evaluate the biological damage, we exposed human epithelial cells in vitro to the LANSCE neutron beams with an entrance dose rate of 2.5 cGy/hr, and studied the induction of chromosome aberrations that were identified with multicolor-banding in situ hybridization (mBAND) technique. With this technique, individually painted chromosomal bands on one chromosome allowed the identification of inter-chromosomal aberrations (translocation to unpainted chromosomes) and intra-chromosomal aberrations (inversions and deletions within a single painted chromosome). Compared to our previous results with gamma-rays and 600 MeV/nucleon Fe ions of high dose rate at NSRL (NASA Space Radiation Laboratory at Brookhaven National Laboratory), the neutron data from the LANSCE experiments showed significantly higher frequency of chromosome aberrations. However, detailed analysis of the inversion type revealed that all of the three radiation types in the study induced a low incidence of simple inversions. Most of the inversions in gamma-ray irradiated samples were accompanied by other types of intrachromosomal aberrations but few inversions were accompanied by interchromosomal aberrations. In contrast, neutrons and Fe ions induced a significant fraction of inversions that involved complex rearrangements of both inter- and intrachromosome exchanges. The distribution of damage sites on chromosome 3 was also compared for different radiation types. The breakpoints were randomly localized on chromosome 3 with neutrons and Fe ions exposure, whereas non-random distribution with clustering breakpoints was observed with gamma-rays exposure. The specific fingerprint of neutron radiations on chromosomal aberrations will be discussed.
Ensuring that the beam delivered from the upgraded Front-End (FE) meets the Key Performance Parameters (KPPs) at each user facility is critical to the success of the LANSCE Accelerator Modernization Project (LAMP). For a high-intensity, multi-user facility like LANSCE, compliance with beam loss and radiation thresholds is as important as the charge delivered to each target. While early LAMPF/LANSCE operations relied on iterative tuning to minimize losses from beam halo and tail particles, the new FE may introduce different beam distributions and loss modes—making predictive modeling essential. To manage this, the F2E (Front-End to End) effort is developing detailed particle-tracking models that reflect realistic beamline conditions, including halo formation and expected diagnostic readings. These "snapshot" simulations aim to benchmark live machine performance at a given moment. This will help quantify how beam quality from the new FE will propagate downstream through the facility. Only by validating these models can we confidently assess and mitigate the potential impacts of the LAMP FE on beam delivery. Post-DTL, the beam splits to serve five major user facilities. Historically, low-energy beam transport has been modeled using TRACE, and higher-energy sections with TRANSPORT. These have now been unified into MAD-X format and validated with codes such as Elegant, pyOrbit, XSuite, Impact-Z, and HPSim. The primary focus now is on accurate modeling of full particle distributions (including beam halo) as they traverse the accelerator and beamlines to each experimental station. All models are at various stages of validation with empirical data.
This report summarizes the performance limits of the LANSCE Coupled-Cavity Linac (CCL). These results are captured or summarized directly from the references cited. This report was written in support of the LANSCE Modernization Project (LAMP).
In this article, we discuss methods for improving the longitudinal impedance of inductive inserts used for space charge compensation in the proton storage ring (PSR) at Los Alamos Neutron Science Center (LANSCE) Facility. The PSR relies on inductive inserts to counteract the capacitive impedance produced by the space charge of the proton beam, which can otherwise lead to beam debunching. Existing inductive inserts, which utilize Toshiba M4C21A ferrite, have been effective but require heating to reduce resistive components that can cause instabilities at higher frequencies. This article explores the potential of alternative ferrite materials, specifically National Magnetics C2050, to enhance the performance of these inserts by reducing the need for heating and minimizing resistive impedance. Through both analytical modeling and CST Particle Studio simulations, it is demonstrated that optimized ferrite materials and geometries can significantly improve space charge compensation while mitigating instability risks, ultimately enhancing the performance of the PSR.
The Second Target Station (STS) at the Spallation Neutron Source (SNS) will address emerging scientific challenges by providing a source of intense cold neutrons to instruments optimized for this source. The STS target will use rotating tungsten blocks and will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 10 8 beam pulses per lifetime. As an R&D activity, the Los Alamos Neutron Science Center (LANSCE) Weapons Neutron Research (WNR) Target 2 (Blue Room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60 % of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. The LANSCE Proton Storage Ring (PSR) and SNS are both short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in <1 μs pulse duration. Strain measurements on the outer surface of three target blocks (bare tungsten, tantalum-clad tungsten, niobium-clad tungsten) were recorded for comparison against neutronics and structural simulations. In conclusion, this experiment and the supporting simulations satisfied the following primary research goals for the STS target.
A compact, nuclear microreactor that utilizes low-enriched uranium fuel is a promising solution to meet U.S. energy demands in nonconventional nuclear markets such as remote and decentralized energy grids. Yttrium hydride (YHx) is a potential moderator material for a microreactor design that reduces the amount of required fuel and provides superior retention of hydrogen at high reactor operating temperatures. Hydrogen diffusion properties in YHx are highly sought after for computer model validation and reactor prototyping. To characterize hydrogen diffusion, a compact dual-zone furnace was developed at Los Alamos National Laboratory and analyzed via neutron imaging at the Los Alamos Neutron Science Center (LANSCE). The goal of these measurements is to assess hydrogen diffusion in YHx samples as a function of applied temperature gradients. Included herein is recent progress in technique and furnace developments as well as initial results from concentration- and temperature-gradient measurements at LANSCE.
This report summarizes the performance limits of the LANSCE Coupled-Cavity Linac (CCL). These results are captured or summarized directly from the references cited. This report was written in support of the LANSCE Modernization Project (LAMP).
This brief report describes the major operational changes resulting from accelerator design and implementation of the LAMP scope. Improvements in operational performance are discussed, along with implications for integration with the existing LANSCE accelerator complex. Potential impacts to the present LANSCE operational modes and integration with the existing personnel and machine protection systems are also discussed.
LAMP is to replace the front-end of LANSCE. Therefore, the device designators for LAMP needs approval from LANSCE. This document defines the agreed upon device designator names to be used in LAMP and in the prototype beamline LAMP in ADEF Tunnel (LAT).
High-energy secondary neutrons, produced by the interaction of galactic cosmic rays with the atmosphere, spacecraft structure and planetary surfaces, contribute to a significant fraction to the dose equivalent in crew members and passengers during commercial aviation travel, and astronauts in space missions. The Los Alamos Nuclear Science Center (LANSCE) neutron facility#s ICE House 30L beamline is known to generate neutrons that simulate the secondary neutron spectra of earth#s atmosphere. The neutron spectrum is also similar to that measured onboard spacecraft like the MIR and International Space Station (ISS). To evaluate the biological damage, we exposed human fibroblasts in vitro to the LANSCE neutron beams without degrader at an entrance dose rate of 25 mGy/hr and analyzed the micronuclei (MN) induction. The cells were also placed behind a 9.9 cm water column to study effect of shielding in the protection of neutron induced damages. It was found that the dose response in the MN frequency was linear for the samples with and without shielding and the slope of the MN yield behind the shielding was reduced by a factor of 3.5. Compared to the MN induction in human fibroblasts exposed to a gamma source at a low dose rate, the RBE was found to be 16.7 and 10.0 for the neutrons without and with 9.9 cm water shielding, respectively.
High-energy secondary neutrons, produced by the interaction of galactic cosmic rays with the atmosphere, spacecraft structure and planetary surfaces, contribute to a significant fraction to the dose equivalent in crew members and passengers during commercial aviation travel, and astronauts in space missions. The Los Alamos Nuclear Science Center (LANSCE) neutron facility's "30L" beam line is known to generate neutrons that simulate the secondary neutron spectrum of the Earth's atmosphere at high altitude. The neutron spectrum is also similar to that measured onboard spacecraft like the MIR and the International Space Station (ISS). To evaluate the biological damage, we exposed human epithelial cells in vitro to the LANSCE neutron beams at an entrance dose rate of 2.5 cGy/hr or gamma-ray at 1.7cGy/hr, and assessed the induction of chromosome aberrations that were identified with mBAND. With this technique, individually painted chromosomal bands on one chromosome allowed the identification of inter-chromosomal aberrations (translocation to unpainted chromosomes) and intra-chromosomal aberrations (inversions and deletions within a single painted chromosome). Compared to our previous results for gamma-rays and 600 MeV/nucleon Fe ions of high dose rate, the neutron data showed a higher frequency of chromosome aberrations. However, detailed analysis of the inversion type revealed that all of the three radiation types in the study induced a low incidence of simple inversions. The low dose rate gamma-rays induced a lower frequency of chromosome aberrations than high dose rate gamma-rays, but the inversion spectrum was similar for the same cytotoxic effect. The distribution of damage sites on chromosome 3 for different radiation types will also be discussed.
To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.