Extremum Seeking-Based Control System for Particle Accelerator Beam Loss Minimization

Particle accelerators throughout the world vary widely in terms of age and availability of advanced noninvasive diagnostics that provide varying levels of detail about the accelerated beams. Additionally, beam loss measurements and current monitors are ubiquitous in the accelerator community, they are noninvasive, and they are some of the most important metrics in terms of preventing damage or irradiation of beam pipes and equipment for high-energy machines. However, beam loss and current measurements are difficult to use for feedback tuning because of a lack of a known analytic relationship between scalar loss measurements throughout an accelerator and the hundreds of thousands of parameters that influence the beam and time variation of the beam source itself. In this work, we present a model-independent extremum seeking (ES) controller, which has been implemented for automated tuning and optimization of the Los Alamos Neutron Science Center (LANSCE) linear ion accelerator based only on scalar quantities, such as beam loss or flux measurements. We demonstrate the approach on various accelerator subsystems, including groups of radio frequency (RF) accelerating cavities, quadrupole magnets, bending magnets, and steering magnets. This tool is now available as a use graphical user interface (GUI) in the LANSCE control room, allowing beam physicists to choose arbitrary groups of parameters and beam loss or current monitors for adaptive tuning.

43 PARTICLE ACCELERATORS↗

Resilient GaN-based Power Module with Improved Diagnostic for Future Accelerator

Los Alamos Neutron Science Center (LANSCE) and Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) play a pivotal role in advancing scientific research and national security initiatives. As a premier facility for neutron science, LANSCE and DARHT provide invaluable insights into fundamental research, materials science, nuclear physics, high-energy physics, material science, and medical imaging. Existing (DC) power supply and pulse modulation technologies used in LANSCE and DARHT face limitations in terms of reliability, maintainability, and diagnostics which hinder the progress of these cutting-edge facilities. By proposing improvements to LANL accelerator facilities’ performance and addressing component failure, we aim to enhance scientific outcomes and minimize disruptions, allowing for more efficient and productive research activities while ensuring the continuity of valuable contributions to the user community. This proposal aims to revolutionize (DC) power supply and pulse power systems for future particle accelerators via the development of a resilient GaN-based power module with improved diagnostic and redundant submodules.

43 PARTICLE ACCELERATORS↗

Physical Sciences Vistas Issue 2, 2020

Dedication and collaboration accelerate mission-essential LANSCE isotope production; Rigorous operations result in newly outfitted gloveboxes; Continuous improvements deliver high-value subcrit data; 'Magnet surge’ expands capabilities for higher tesla science.

07 ISOTOPE AND RADIATION SOURCES↗

Experimental Safe Extremum Seeking for Accelerators

Here, we demonstrate the recent designs of safe extremum seeking (Safe ES) on the 1-km-long charged particle accelerator at the Los Alamos Neutron Science Center (LANSCE). Safe ES is a modification of extremum seeking (ES) which, in addition to minimizing an analytically unknown cost, also employs a safety filter based on an analytically unknown control barrier function (CBF) safety metric. Tuning is necessitated by accelerators being large complex systems, with many drifting parameters due to thermal effects and degradation. At the same time, safe operation (the maintenance of state constraints) is crucial, as damage brings astronomical costs, both financially and in operation downtime. Our measured (but analytically unknown) safety metric is the beam current. We perform multivariable Safe ES on three accelerator applications, in which we adapt 4, 6, and 3 magnet strength parameters, respectively. Two of the three applications are for validated simulation models of beamlines at LANSCE: the first for the proton radiography (pRad) beamline of 800-MeV protons for spot size tuning; the second on a high-performance code, HPSim, for tuning the low-energy beam transport (LEBT) region that contains a beam of 750-keV protons. The third is an experimental tuning of the steering magnets in the LEBT at LANSCE.

43 PARTICLE ACCELERATORS↗

Report for LANSCE Futures Spring 2021 Workshop Series

The Los Alamos Neutron Science Center (LANSCE) has a long and successful history of delivering high-impact science for NNSA missions. The breadth of science LANSCE delivers is enabled by a unique combination of beam power, flexibility, and authorization basis. Though LANSCE is entering its 50th year of operations, current plans for the stockpile require LANSCE capabilities beyond 2050. These requirements demand a technical conversation about the accelerator and the long-term scientific vision for the facility, so we convened a set of workshops to initiate that conversation. The LANSCE Futures workshops spanned three capability areas of LANSCE: dynamic radiography, scattering science, and nuclear science. Participants included the relevant experts from the programs sponsoring LANSCE, the experimentalists utilizing the end-stations, and accelerator systems experts. A final workshop combined the three focus areas to begin the conversation about capabilities that could meet future mission needs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LAMP Manufacturing Survey (Final Report)

This report presents the results of a market manufacturing survey performed for fabricating radiofrequency quadrupoles (RFQ) and Drift Tube Linear Accelerator (DTL) components needed for the Los Alamos Neutron Science Center (LANSCE) Modernization Project (LAMP). A review on existing RFQs and DTLs with their parameters, a summary of specific capabilities needed to manufacture them, the common issues during the fabrication process, their consequences, and resolutions to these problems is presented in this report. The goal of this study is to identify potential collaborators and companies capable of manufacturing the necessary accelerator equipment, while minimizing cost and schedule risks that could impact the future modernization of the LANSCE facility.

43 PARTICLE ACCELERATORS↗

LAMP Emittance Budget LAMP-ENG-RPT-002

This report summarizes the performance limits of the LANSCE Coupled-Cavity Linac (CCL). These results are captured or summarized directly from the references cited. This report was written in support of the LANSCE Modernization Project (LAMP).

43 PARTICLE ACCELERATORS↗

Physical Sciences Vistas: Issue 4 2021

In this issue of Physical Sciences Vistas we highlight examples of “excellence in nuclear security.” In this issue, highlights of our outstanding work supporting the Laboratory’s nuclear security enterprise include the following: The complete refurbishment of Sigma’s surface finishing lab. Pride in the lab’s revitalized condition on the part of the operations and R&D staff responsible for this complex operation is well justified. Development of advanced materials and processes enabling next-generation weapons designs, much of which has been facilitated by projects supported by the Laboratory Directed Research and Development Program. The use of proton radiography in illuminating elements important to validating high explosive burn models. The experimental series was a collaboration between Los Alamos researchers and staff at Lawrence Livermore and Sandia national laboratories and the United Kingdom’s Atomic Weapons Establishment. Deployment of a sophisticated remote handling unit to safely transfer highly radioactive materials required to support mission-critical projects. The skillful swap of an electrical transformer at the Los Alamos Neutron Science Center (LANSCE). The deliberate operation restored power to the accelerator in less than estimated time. A look at George Goff ’s role in translating fundamental science into applied solutions essential to the Lab’s nuclear security mission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Area-A Options Cost Estimate Report

Five options for re-establishing various configurations of beam to LANSCE Area A were considered. Bottoms up cost estimates to implement three of the options were developed. The two options not costed were considered too complex and too expensive compared with the other options based on their relative benefits to experimental programs at LANSCE.

43 PARTICLE ACCELERATORS↗

Improving Longitudinal Impedance of Inductive Inserts

In this article, we discuss methods for improving the longitudinal impedance of inductive inserts used for space charge compensation in the proton storage ring (PSR) at Los Alamos Neutron Science Center (LANSCE) Facility. The PSR relies on inductive inserts to counteract the capacitive impedance produced by the space charge of the proton beam, which can otherwise lead to beam debunching. Existing inductive inserts, which utilize Toshiba M4C21A ferrite, have been effective but require heating to reduce resistive components that can cause instabilities at higher frequencies. This article explores the potential of alternative ferrite materials, specifically National Magnetics C2050, to enhance the performance of these inserts by reducing the need for heating and minimizing resistive impedance. Through both analytical modeling and CST Particle Studio simulations, it is demonstrated that optimized ferrite materials and geometries can significantly improve space charge compensation while mitigating instability risks, ultimately enhancing the performance of the PSR.

43 PARTICLE ACCELERATORS↗

LAMP Manufacturing Survey [Slides]

The LANL Accelerator Strategy Office (ASO) requires the support of AOT-MDE to perform a trade study on the current manufacturing capabilities required to modernize the Los Alamos Neutron Science Center (LANSCE). The purpose of the study will be to identify and potentially minimize cost and schedule risks that could impact the LANSCE Modernization Project (LAMP).

43 PARTICLE ACCELERATORS↗

Second Target Station Project: LANSCE WNR Target 2 (Blue Room) Experiment 2022

The Second Target Station (STS) at SNS will address emerging scientific challenges by providing a source of intense, cold neutrons to instruments optimized for this source, using rotating, tungsten target blocks. The STS target will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 108 beam pulses per lifetime. As an R&D activity, the LANSCE WNR Target 2 (blue room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60% of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. Both the LANSCE Proton Storage Ring (PSR) and SNS are short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in < 1 microsecond pulse duration.