Search NASA⌕ Search

SEARCH · Search NASA

Results for “LC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Peak Annotation and Verification Engine for Untargeted LC–MS Metabolomics

Untargeted metabolomics can detect more than 10 000 peaks in a single LC–MS run. The correspondence between these peaks and metabolites, however, remains unclear. Here in this study, we introduce a Peak Annotation and Verification Engine (PAVE) for annotating untargeted microbial metabolomics data. The workflow involves growing cells in 13 C and 15 N isotope-labeled media to identify peaks from biological compounds and their carbon and nitrogen atom counts. Improved deisotoping and deadducting are enabled by algorithms that integrate positive mode, negative mode, and labeling data. To distinguish metabolites and their fragments, PAVE experimentally measures the response of each peak to weak in-source collision induced dissociation, which increases the peak intensity for fragments while decreasing it for their parent ions. The molecular formulas of the putative metabolites are then assigned based on database searching using both m/z and C/N atom counts. Application of this procedure to Saccharomyces cerevisiae and Escherichia coli revealed that more than 80% of peaks do not label, i.e., are environmental contaminants. More than 70% of the biological peaks are isotopic variants, adducts, fragments, or mass spectrometry artifacts yielding ~2000 apparent metabolites across the two organisms. About 650 match to a known metabolite formula based on m/z and C/N atom counts, with 220 assigned structures based on MS/MS and/or retention time to match to authenticated standards. Lastly, PAVE enables systematic annotation of LC–MS metabolomics data with only ~4% of peaks annotated as apparent metabolites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbamoylation as an Effective Tool in the Analysis of the Soman Nerve Agent Marker Pinacolyl Alcohol in Soil Matrices by EI-GC-MS and LC-HRMS

Pinacolyl alcohol (PA) is a Schedule 2 chemical commonly featured in most proficiency tests (PTs) administered by the Organisation for the Prohibition of Chemical Weapons (OPCW) due to its direct as well as forensic link to the nerve agent Soman. Therefore, its detection by Chemical Weapons Convention (CWC) inspection teams during on-site investigations is a strong indicator of the past or latent presence of Soman in the environment. Its small molecular weight (102), early elution time, and poor ionization profile make PA a challenging analyte to detect particularly at low concentrations (∼1–10 μg/g). In this work, 1,1′-carbonyldimidazole (CDI) has been used to effectively modify PA for the first time in two different soil matrices (Virginia type A soil and silt sediment) at two separate concentrations (1 and 10 μg/g) for its subsequent detection by EI-GC-MS and LC-HRMS methods. For the EI-GC-MS analysis, the PA carbamate derivative (PIC) exhibits improved chromatography relative to PA such as improved peak shape, increased molecular weight (196 for PIC and 102 for PA) and increased retention time (16.9 min for PIC and ∼4.1 min for PA). In addition, the derivatization also improves the detection of PA by LC-HRMS as the PIC product possesses protonation sites (i.e., imidazole ring) relative to none exhibited by PA. More importantly, the carbamoylation proceeds under mild conditions (55 °C, no base) and rapidly (3 h), characteristics that make it an appealing protocol for the analysis of PA during OPCW PTs or real case scenarios particularly in instances where it is present at low concentrations. It is anticipated that the protocol can be applied to the forensic analysis of this important Soman marker in various environmental matrices.

Chemistry↗

Improved LC-MS/MS Spectral Counting Statistics by Recovering Low Scoring Spectra Matched to Confidently Identified Peptide Sequences

Spectral counting has become a popular semi-quantitative method for LC-MS/MS based proteome quantification; however, this methodology is often not reliable when proteins are identified by a small number of spectra. Here we present a simple strategy to improve spectral counting based quantification for low abundance proteins by recovering low quality or low scoring spectra for confidently identified peptides. In this approach, stringent data filtering criteria were initially applied to achieve confident peptide identifications with low false discovery rate (e.g., <1%) after LC-MS/MS analysis and database search by SEQUEST. Then, all low scoring MS/MS spectra that match to this set of confidently identified peptides were recovered, leading to more than 20% increase of total identified spectra. The validity of these recovered spectra was assessed by the parent ion mass measurement error distribution, retention time distribution, and by comparing the individual low score and high score spectra that correspond to the same peptides. The results support that the recovered low scoring spectra have similar confidence levels in peptide identifications as the spectra passing the initial stringent filter. The application of this strategy of recovering low scoring spectra significantly improved the spectral count quantification statistics for low abundance proteins, as illustrated in the identification of mouse brain region specific proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Sources of Technical Variability in Quantitative LC-MS Proteomics: Human Brain Tissue Sample Analysis.

To design a robust quantitative proteomics study, an understanding of both the inherent heterogeneity of the biological samples being studied as well as the technical variability of the proteomics methods and platform is needed. Additionally, accurately identifying the technical steps associated with the largest variability would provide valuable information for the improvement and design of future processing pipelines. We present an experimental strategy that allows for a detailed examination of the variability of the quantitative LC-MS proteomics measurements. By replicating analyses at different stages of processing, various technical components can be estimated and their individual contribution to technical variability can be dissected. This design can be easily adapted to other quantitative proteomics pipelines. Herein, we applied this methodology to our label-free workflow for the processing of human brain tissue. For this application, the pipeline was divided into four critical components: Tissue dissection and homogenization (extraction), protein denaturation followed by trypsin digestion and SPE clean-up (digestion), short-term run-to-run instrumental response fluctuation (instrumental variance), and long-term drift of the quantitative response of the LC-MS/MS platform over the 2 week period of continuous analysis (instrumental stability). From this analysis, we found the following contributions to variability: extraction (72%) >> instrumental variance (16%) > instrumental stability (8.4%) > digestion (3.1%). Furthermore, the stability of the platform and its’ suitability for discovery proteomics studies is demonstrated.

Environmental Molecular Sciences Laboratory↗

Frequency jumps in single chip microwave LC oscillators

We report on the experimental observation of oscillation frequency jumps in microwave LC oscillators fabricated using standard complementary metal-oxide-semiconductor technologies. The LC oscillators, operating at a frequency of about 20 GHz, consist of a single turn planar coil, a metal-oxide-metal capacitor, and two cross-coupled metal-oxide-semiconductor field effect transistors used as negative resistance network. At 300 K as well as at 77 K, the oscillation frequency is a continuous function of the oscillator bias voltage. At 4 K, frequency jumps as large as 30 MHz are experimentally observed. This behavior is tentatively attributed to the emission and capture of single electrons from defects and dopant atoms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Emittance preservation for the electron arm in a single PWFA-LC stage using quasi-adiabatic plasma density ramp matching sections

Plasma-based acceleration (PBA) is being considered for a next generation linear collider (LC). In some PBA-LC designs for the electron arm, the extreme beam parameters are expected to trigger background ion motion within the witness beam, which can lead to longitudinally varying nonlinear focusing forces and result in an unacceptable emittance growth of the beam. To mitigate this, we propose to use quasi-adiabatic plasma density ramps as matching sections at the entrance and exit of each stage. We match the witness electron beam to the low density plasma entrance, where the beam initially has a large matched spot size so the ion motion effects are relatively small. As the beam propagates in the plasma density upramp, it is quasi-adiabatically focused, and its distribution maintains a non-Gaussian equilibrium distribution in each longitudinal slice throughout the process, even when severe ion collapse has occurred. This only causes small amounts of slice emittance growth. The phase mixing between slices with different betatron frequencies leads to additional projected emittance growth within the acceleration stage. A density downramp at the exit of an acceleration section can eliminate much of the slice and projected emittance growth as the beam and ion motion adiabatically defocuses and decreases, respectively. Simulation results from QuickPIC with Azimuthal Decomposition show that within a single acceleration stage with a 25 GeV energy gain, this concept can limit the projected emittance growth to only ∼2% for a 25 GeV, 100 nm emittance witness beam and ∼20% for a 100 GeV, 100 nm normalized emittance witness beam. The trade-off between the adiabaticity of the plasma density ramp and the initial ion motion at the entrance for a given length of the plasma density ramp is also discussed.

Physics↗

Micromachined ceramic-based chipless LC resonator for high-temperature wireless sensing applications in harsh environments

The primary objective of this work was the fabrication and testing of a wireless LC resonator based on micro-patterned electroceramic materials for the monitoring of high-temperature systems. The twodimensional planar LC resonator sensors were designed and simulated using ANSYS Maxwell software, and these sensors were then fabricated from electrically conductive La 2 NiO 4 /Al 2 O 3 particulate inks. Initially, the phases of La 2 NiO 4 /Al 2 O 3 composite were evaluated by XRD. The patterning and deposition of the ink were completed using a novel micro-casting process onto Al 2 O 3 ceramic substrates, and the final pattern was bonded onto the substrate at 1200 °C for 2 h. The features and the reliability were analyzed by SEM microscopy. The frequency shift with respect to temperature was measured, which is directly related to changes in the sensor’s dielectric permittivity and pattern dimensions. The sensors were characterized at 500 °C–1000 °C in an ambient atmosphere with an RF signal ranging from 10–80 MHz at 175 kHz·s –1 sweep rate. The sensors showed a sensitivity of ~350 kHz °C –1 from 500 °C–1000 °C. Here, a new robust and adaptive signal processing approach was introduced to increase the degree of freedom for analyzing wireless sensors.

42 ENGINEERING↗

LC-IMS-MS Feature Finder

The LC-IMS-MS Feature Finder finds LC-IMS-MS features and conformers using deisotoped features from DeconTools.

Gibbons, Bryson↗

LC-IMS-MS Feature Finder

LC-IMS-MS Feature Finder is a command line software application which searches for possible molecular ion signatures in multidimensional liquid chromatography, ion mobility spectrometry, and mass spectrometry data by clustering deisotoped peaks with similar monoisotopic mass values, charge states, elution times, and drift times. The software application includes an algorithm for detecting multiple conformations and co-eluting species in the ion mobility dimension. LC-IMS-MS Feature Finder is designed to create an output file with detected features that includes associated information about the detected features.

Crowell, KevinL.↗

Summary Statistics for LC_TA03_130719: Micro-CT Data Acquired at LLNL, Specimen 3 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, lithium carbonate (LC). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, LC_TA03_130719, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images 2 . The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for LC_HT02_130812: Micro-CT Data Acquired at LLNL, Specimen 2 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, lithium carbonate (LC). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, LC_HT02_130812, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for LC_HT01_130808: Micro-CT Data Acquired at LLNL, Specimen 1 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, lithium carbonate (LC). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, LC_HT01_130808, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

VERSE-LC TCCR Model Calibration using Batch 1A, Batch 2, and Batch 3 Column Data

The objective of this work is to utilize on-line gamma monitoring data collected during Tank Closure Cesium Removal (TCCR) Column Batch 3 operations to calibrate the parameters (essentially, the correction/dilution factors (CF or DF)) used in the VERSE-LC models for the prediction of cesium breakthrough while processing Savannah River Site (SRS) Tank 10H dissolved saltcake High-Level Waste through a packed cylindrical bed of Crystalline Silicotitanate (CST). Calibrated VERSE-LC models could be applied to aid in evaluating future TCCR operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nonlinear analysis of a family of LC tuned inverters

A family of four dc-to-square-wave LC tuned inverters are analyzed using singular point. Limit cycles and waveshape characteristics are given for three modes of oscillation: quasi-harmonic, relaxation, and discontinuous. An inverter in which the avalanche breakdown of the transistor emitter-to-base junction occurs is discussed and the starting characteristics of this family of inverters are presented. The LC tuned inverters are shown to belong to a family of inverters with a common equivalent circuit consisting of only three 'series' elements: a five-segment piecewise-linear current-controlled resistor, linear inductor, and linear capacitor.

Lee, F. C. Y.↗

Development of LC-13C NMR

This study involves the development of C-13 nuclear resonance as an on-line detector for liquid chromatography (LC-C-13 NMR) for the chemical characterization of aviation fuels. The initial focus of this study was the development of a high sensitivity flow C-13 NMR probe. Since C-13 NMR sensitivity is of paramount concern, considerable effort during the first year was directed at new NMR probe designs. In particular, various toroid coil designs were examined. In addition, corresponding shim coils for correcting the main magnetic field (B sub 0) homogeneity were examined. Based on these initial probe design studies, an LC-C-13 NMR probe was built and flow C-13 NMR data was obtained for a limited number of samples.

Dorn, H. C.↗

Identification of process related trace level impurities in the actinide decorporation agent 3,4,3-LI(1,2-HOPO): Nozzle–skimmer fragmentation via ESI LC–QTOFMS

We report that 3,4,3-LI(1,2-HOPO) is a chelating ligand and decorporation agent that can remove radioactive lanthanides and actinides from the body. Identification of trace impurities in drug samples is gaining much interest due to their significant influence on drug activity. In this study, trace impurities were detected in manufactured lots of 3,4,3-LI(1,2-HOPO) by a developed method of Liquid Chromatography coupled with photo-diode array UV detection and Electrospray Ionization-Quadrupole Time of Flight Mass spectrometry (LC-QTOFMS), via induced-in-source or collision-induced mass fragmentation (Nozzle-Skimmer Fragmentation). Molecular ions were fragmented within the nozzle-skimmer region of electrospray ionization (ESI) mass spectrometer equipped with a Time of Flight detector. Eight major (detected at levels higher than a 0.1% threshold) and seven minor trace impurities were identified. The respective structures of these impurities were elucidated via analysis of the generated fragment ions using mass fragmentation and elemental composition software. Proposed structures of impurities were further confirmed via isotopic modeling.

3,4,3-LI(1,2-HOPO) ligand↗

Molecular remodeling in Populus PdKOR RNAi roots profiled using LC-MS/MS proteomics

Plant endo-β-1,4-glucanases belonging to the Glycoside Hydrolase Family 9 have functional roles in cell wall biosynthesis and remodeling via endohydrolysis of (1→4)-β-D-glucosidic linkages. Modification of cell wall chemistry via RNAi-mediated downregulation of Populus deltoides KOR1 (PdKOR), a endo-β-1,4-glucanase gene, in Populus deltoides has been shown to have functional consequences for the composition of secondary metabolome and the ability of modified roots to interact with beneficial microbes. The molecular remodeling that underlies the observed differences at metabolic, physiological, and morphological levels in roots is not well understood. Here we used a LC-MS/MS-based proteome profiling approach to survey the molecular remodeling in root tissues of PdKOR and control plants. A total of 14316 peptides were identified and these mapped to 7139 P. deltoides proteins. Based on 90% sequence identity, the measured protein accessions represent 1187 functional protein groups. Analysis of GO categories and specific individual proteins showed differential expression of proteins relevant to plant-microbe interactions, cell wall chemistry, and metabolism. The new proteome dataset serves as a useful resource for deriving new hypotheses and empirical testing pertaining to functional roles of proteins and pathways in differential priming of plant roots to interactions with microbes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗