The Legion Programming Model
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Based on the full BABAR data sample, we report improved measurements of the ratios R(D{sup (*)}) = {Beta}({bar B} {yields} D{sup (*)} {tau}{sup -}{bar {nu}}{sub {tau}})/{Beta}({bar B} {yields} D{sup (*)} {ell}{sup -}{bar {nu}}{sub {ell}}), where {ell} is either e or {mu}. These ratios are sensitive to new physics contributions in the form of a charged Higgs boson. We measure R(D) = 0.440 {+-} 0.058 {+-} 0.042 and R(D*) = 0.332 {+-} 0.024 {+-} 0.018, which exceed the Standard Model expectations by 2.0{sigma} and 2.7{sigma}, respectively. Taken together, our results disagree with these expectations at the 3.4{sigma} level. This excess cannot be explained by a charged Higgs boson in the type II two-Higgs-doublet model. We also report the observation of the decay {bar B} {yields} D{tau}{sup -} {bar {nu}}{sub {tau}}, with a significance of 6.8{sigma}.
The electrical and optical properties of warm dense beryllium along the principal Hugoniot for temperatures from 0.95 eV to 10.65 eV and densities from 3.8 to 6.0 g/cm{sup 3} are investigated by using quantum molecular dynamics (QMD) simulations combined with the Kubo-Greenwood formulation. The dc conductivity σ{sub dc} and the ionization fraction are yielded by fitting the optical conductivity with the Drude-Smith model. The first-principles transport coefficients are compared with results of the Lee-More model and the Brysk model [Plasma Phys. 17, 473 (1975)]. Compared with the QMD result, the Lee-More model underestimates σ{sub dc} by 87% at low temperatures, approaches the QMD result gradually with the temperature rising, yet still underestimates σ{sub dc} by 49% corresponding to the temperature 10.65 eV. In the whole temperature range under investigation, the Brysk model overestimates the electronic thermal conductivity κ while the Lee-More model underestimates κ. The differences are reduced with the temperature increasing. At the temperature 10.65 eV, the Brysk κ is still around twice as large as the QMD result, and the Lee-More κ is smaller than the QMD data by about 40%. In addition, QMD Rosseland mean opacities are shown to be three orders of magnitude larger than results of the average-atom model.
To support the transition to next-generation refrigerants, accurate modelling of heat transfer and pressure drop is essential for designing efficient heat exchangers. Current models, largely based on traditional refrigerants and unexpanded micro-fin tubes, may not reliably predict performance for new refrigerants and expanded micro-fin geometries. This study evaluates four condensation models using experimental data for six A2L refrigerants: R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E). For heat transfer models, the Han and Lee (2005) model initially yields the best accuracy (mean absolute Deviation, MAD = 22.1%). To further improve predictions, a correction factor reduces the Cavallini et al. (2009) model’s MAD from 68.2% to 15.4%, while optimization of the Kedzierski and Goncalves (1997) model achieves a MAD of 13.1%. For pressure drop, the Cavallini et al. (1997) model proves most accurate (MAD = 6.4%), with the simpler Haraguchi et al. (1993) model also effective (MAD = 9.4%). Keywords: Flow condensation models, heat transfer coefficient, frictional pressure drop, next-generation refrigerants, aluminum micro-fin tubes
In quantum mechanics the deterministic property of classical physics is an emergent phenomenon appropriate only on macroscopic scales. Lee and Wick introduced Lorentz invariant quantum theories where causality is an emergent phenomenon appropriate for macroscopic time scales. In this paper we analyze a Lee-Wick version of the O(N) model. We argue that in the large-N limit this theory has a unitary and Lorentz invariant S matrix and is therefore free of paradoxes in scattering experiments. We discuss some of its acausal properties.
I explain the Sato-Lee (SL) model and its extension to the neutrino-induced pion production off the nucleon. Then I discuss applications of the SL model to incoherent and coherent pion productions in the neutrino-nucleus scattering. I mention a further extension of this approach with a dynamical coupled-channels model developed in Excited Baryon Analysis Center of JLab.
We introduce a new dark matter candidate, the lightest U-parity particle (LUP). We suggest it as a good dark matter candidate especially in the R-parity violating supersymmetric model.
We consider the scientifically challenging and policy-relevant task of understanding the past and projecting the future dynamics of the Antarctic ice sheet. The Antarctic ice sheet has shown a highly nonlinear threshold response to past climate forcings. Triggering such a threshold response through anthropogenic greenhouse gas emissions would drive drastic and potentially fast sea level rise with important implications for coastal flood risks. Previous studies have combined information from ice sheet models and observations to calibrate model parameters. These studies have broken important new ground but have either adopted simple ice sheet models or have limited the number of parameters to allow for the use of more complex models. These limitations are largely due to the computational challenges posed by calibration as models become more computationally intensive or when the number of parameters increases. Here, we propose a method to alleviate this problem: a fast sequential Monte Carlo method that takes advantage of the massive parallelization afforded by modern high-performance computing systems. We use simulated examples to demonstrate how our sample-based approach provides accurate approximations to the posterior distributions of the calibrated parameters. The drastic reduction in computational times enables us to provide new insights into important scientific questions, for example, the impact of Pliocene era data and prior parameter information on sea level projections. These studies would be computationally prohibitive with other computational approaches for calibration such as Markov chain Monte Carlo or emulation-based methods. We also find considerable differences in the distributions of sea level projections when we account for a larger number of uncertain parameters. For example, based on the same ice sheet model and data set, the 99th percentile of the Antarctic ice sheet contribution to sea level rise in 2300 increases from 6.5 m to 13.1 m when we increase the number of calibrated parameters from three to 11. With previous calibration methods, it would be challenging to go beyond five parameters. Here, this work provides an important next step toward improving the uncertainty quantification of complex, computationally intensive and decision-relevant models.
Purpose: To establish an organ dose database for pediatric and adolescent reference individuals undergoing computed tomography (CT) examinations by using Monte Carlo simulation. The data will permit rapid estimates of organ and effective doses for patients of different age, gender, examination type, and CT scanner model. Methods: The Monte Carlo simulation model of a Siemens Sensation 16 CT scanner previously published was employed as a base CT scanner model. A set of absorbed doses for 33 organs/tissues normalized to the product of 100 mAs and CTDI{sub vol} (mGy/100 mAs mGy) was established by coupling the CT scanner model with age-dependent reference pediatric hybrid phantoms. A series of single axial scans from the top of head to the feet of the phantoms was performed at a slice thickness of 10 mm, and at tube potentials of 80, 100, and 120 kVp. Using the established CTDI{sub vol}- and 100 mAs-normalized dose matrix, organ doses for different pediatric phantoms undergoing head, chest, abdomen-pelvis, and chest-abdomen-pelvis (CAP) scans with the Siemens Sensation 16 scanner were estimated and analyzed. The results were then compared with the values obtained from three independent published methods: CT-Expo software, organ dose for abdominal CT scan derived empirically from patient abdominal circumference, and effective dose per dose-length product (DLP). Results: Organ and effective doses were calculated and normalized to 100 mAs and CTDI{sub vol} for different CT examinations. At the same technical setting, dose to the organs, which were entirely included in the CT beam coverage, were higher by from 40 to 80% for newborn phantoms compared to those of 15-year phantoms. An increase of tube potential from 80 to 120 kVp resulted in 2.5-2.9-fold greater brain dose for head scans. The results from this study were compared with three different published studies and/or techniques. First, organ doses were compared to those given by CT-Expo which revealed dose differences up to several-fold when organs were partially included in the scan coverage. Second, selected organ doses from our calculations agreed to within 20% of values derived from empirical formulae based upon measured patient abdominal circumference. Third, the existing DLP-to-effective dose conversion coefficients tended to be smaller than values given in the present study for all examinations except head scans. Conclusions: A comprehensive organ/effective dose database was established to readily calculate doses for given patients undergoing different CT examinations. The comparisons of our results with the existing studies highlight that use of hybrid phantoms with realistic anatomy is important to improve the accuracy of CT organ dosimetry. The comprehensive pediatric dose data developed here are the first organ-specific pediatric CT scan database based on the realistic pediatric hybrid phantoms which are compliant with the reference data from the International Commission on Radiological Protection (ICRP). The organ dose database is being coupled with an adult organ dose database recently published as part of the development of a user-friendly computer program enabling rapid estimates of organ and effective dose doses for patients of any age, gender, examination types, and CT scanner model.
Not Available
Understanding laser–target coupling is of the utmost importance for achieving high performance in laser-direct-drive (LDD) inertial confinement fusion (ICF) experiments. Thus, accurate modeling of electron transport and deposition through ICF-relevant materials and conditions is necessary to quantify the total thermal conduction and ablation. The stopping range is a key transport quantity used in thermal conduction models; in this work, we review the overall role that the electron mean free path (MFP) plays in thermal conduction and hydrodynamic simulations. The currently used modified Lee–More model employs various physics approximations. We discuss a recent model that uses time-dependent density functional theory (TD-DFT) to eliminate these approximations in both the calculation of the electron stopping power and corresponding MFP in conduction zone polystyrene (CH) plasma. In general, the TD-DFT calculations showed a larger MFP (lower stopping power) than the standard modified Lee–More model. Using the TD-DFT results, an analytical model for the electron deposition range, λTD−DFT(ρ,T,K), was devised for CH plasmas between ρ=[0.05−1.05] g/cm3, kBT=[100−1000] eV. We implemented this model into LILAC, for simulations of a National Ignition Facility-scale LDD implosion and compared key physics quantities to ones obtained by simulations using the standard model. The implications of the obtained results and the path moving forward to calculate this same quantity in conduction-zone deuterium–tritium plasmas are further discussed, to hopefully close the understanding gap for laser target coupling in LDD-ICF simulations.
Fractures that propagate off of weak slip planes are known as wing cracks and often play important roles in both tectonic deformation and fluid flow across reservoir seals. Previous numerical models have produced the basic kinematics of wing crack openings but generally have not been able to capture fracture geometries seen in nature. Here we present both a phase-field modeling approach and a physical experiment using gelatin for a wing crack formation. By treating the fracture surfaces as diffusive zones instead of as discontinuities, the phase-field model does not require consideration of unpredictable rock properties or stress inhomogeneities around crack tips. It is shown by benchmarking the models with physical experiments that the numerical assumptions in the phase-field approach do not affect the final model predictions of wing crack nucleation and growth. With this study, we demonstrate that it is feasible to implement the formation of wing cracks in large scale phase-field reservoir models.
The Qweak experiment at the Thomas Jefferson National Accelerator Facility measures the parity violating asymmetry in longitudinally polarized electron scattering from the proton at very low momentum transfer, Q{sup 2} = 0.026 (GeV/c){sup 2}, at an incident electron beam energy of 1.16 GeV. With this measurement and the earlier results of the parity violating elastic scattering experiments, the Qweak experiment determines the weak charge of the proton with a 4% combined statistical and systematic error. This measurement will be used to determine the weak mixing angle that is predicted by the Standard Model from the Z{sup 0} pole down to lower energies. Qweak will determine to a 0.3% relative precision, providing a competitive measurement of the running of this quantity. Moreover, if there is a significant deviation of the weak mixing angle from the Standard Model prediction, then the Qweak experiment will give a glimpse of possible extensions of the Standard Model.
In this study, steady-state and transient internal-flow critical heat flux (CHF) experiments were carried out under two flow conditions, at atmospheric pressure, on 316 stainless steel (316-SS) and iron-chromium-aluminum (FeCrAl) tubes. Slow power transients at a low mass flow (300 kg/m 2 - s) with very low subcooling (X e =-0.0054) generated premature CHFs, which were prevented by faster power transients and high mass flow (1000 kg/m 2 - s). The measured transient CHFs increased linearly with increasing power transients, compared with the steady-state CHF. Yet, the wall superheat at the CHFs decreased with faster power transients. Transient CHF correlations highlighting heterogeneous spontaneous nucleation were calibrated to the measured CHFs and compared with other existing correlations. Transient CHF multipliers were acquired from pool and flow boiling empirical CHF correlations that were generated. The multipliers were applied to the RELAP5-3D nuclear system code to analyze the discrepancies between the measured data and the predicted CHF and post-CHF behavior, which improved peak cladding temperature predictions by 24.6%. A variance-based global sensitivity study perturbing the experimental uncertainties and cladding material thermal properties showed the diminishing influence of flow boiling heat transfer with increasing power transients, highlighting the significance of the volumetric heat capacity for the cladding integrity during transients. Transient CHF correlations were applied to the most limiting design basis accident: a hot-zero-power reactivity-initiated accident on a generic pressurized water reactor RELAP5-3D model.
A new characteristic discontinuous Galerkin (CDG) advection scheme is presented. In contrast to standard discontinuous Galerkin schemes, the test functions themselves follow characteristics in order to ensure conservation and the edges of each element are also traced backwards along characteristics in order to create a swept region , which is integrated in order to determine the mass flux across the edge. Both the accuracy and performance of the scheme are greatly improved by the use of large Courant–Friedrichs–Lewy numbers for a shear flow test case and the scheme is shown to scale sublinearly with the number of tracers being advected, outperforming a standard flux corrected transport scheme for 10 or more tracers with a linear basis. Moreover the CDG scheme may be run to arbitrarily high order spatial accuracy and on unstructured grids, and is shown to give the correct order of error convergence for piecewise linear and quadratic bases on regular quadrilateral and hexahedral planar grids. Using a modal Taylor series basis, the scheme may be made monotone while preserving conservation with the use of a standard slope limiter, although this reduces the formal accuracy of the scheme to first order. The second order scheme is roughly as accurate as the incremental remap scheme with nonlocal gradient reconstruction at half the horizontal resolution. Furthermore, the scheme is being developed for implementation within the Model for Prediction Across Scales (MPAS) Ocean model, an unstructured grid finite volume ocean model.
X-ray microtomography is used to visualize, in-situ, the three-dimensional nature of the magnetic field induced macro-structures (>1 ?m) inside a bulk (not, vert, similar1 mm diameter) magnetite-particle-mineral oil ferrofluid sample. Columnar structures of not, vert, similar10 ?m diameter were seen under a 0.35 kG applied magnetic field, while labyrinth type structures not, vert, similar4 ?m in width were seen at 0.55 kG. The structures have height/width aspect ratios >100. The results show that the magnetite volume fraction is not constant within the structures and on average is considerably less than a random sphere packing model.