Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIGAMENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Experiment K-6-03. Gravity and skeletal growth, part 1. Part 2: Morphology and histochemistry of bone cells and vasculature of the tibia; Part 3: Nuclear volume analysis of osteoblast histogenesis in periodontal ligament cells; Part 4: Intervertebral disc swelling pressure associated with microgravity

Bone area, bone electrophysiology, bone vascularity, osteoblast morphology, and osteoblast histogenesis were studied in rats associated with Cosmos 1887. The results suggest that the synchronous animals were the only group with a significantly larger bone area than the basal group, that the bone electrical potential was more negative in flight than in the synchronous rats, that the endosteal osteoblasts from flight rats had greater numbers of transitional Golgi vesicles but no difference in the large Golgi saccules or the alkaline phosphatase activity, that the perioteal vasculature in the shaft of flight rats often showed very dense intraluminal deposits with adjacent degenerating osteocytes as well as lipid accumulations within the lumen of the vessels and sometimes degeneration of the vascular wall (this change was not present in the metaphyseal region of flight animals), and that the progenitor cells decreased in flight rats while the preosteoblasts increased compared to controls. Many of the results suggest that the animals were beginning to recover from the effects of spaceflight during the two day interval between landing and euthanasia; flight effects, such as the vascular changes, did not appear to recover.

Holton, E.↗

Assessing the influence of processing parameters and external loading on the nanoporous structure and morphology of nanoporous gold toward catalytic applications

Nanoporous gold structure gains several unique physical and chemical properties from its nanoscale foam structure composed of ligaments and connected pores. The high specific surface area and interconnected pores make its structure ideal for gas catalysis. Catalytic activity arises in part from the high number density of surface steps and kinks at points of high curvature in the nanoporous structure. However, the structure also makes the material macroscopically brittle and unreliable for many applications due to poor mechanical stability. The ligament diameter, which regulates both desirable chemical properties and mechanical instability, can be tuned to over three orders of magnitude, but few morphology features can be adjusted independently of this. In this report we fabricate nanoporous gold with an average ligament diameter of around 10 nm while varying synthesis parameters and quantify the resulting morphology in order to evaluate the effect of processing on the resulting nanoscale foam structure. In situ tensile experiments are performed to observe how both individual ligaments and the foam structure's features change during deformation in real-time. We found two new morphology features that are independently controllable through synthesis parameters and are likely to influence mechanical stability while preserving or enhancing catalytic activity. The curvature of the ligaments can be increased by stirring the electrolyte during dealloying and the width of the ligament diameter size distribution can be adjusted by controlling the coarsening rate. In situ mechanical tests show that grain boundaries can influence crack propagation and that ligaments removed from the crack tip experience both elastic and plastic stress.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Base-catalyzed sol-gel inks for direct ink writing of high resolution hierarchically porous carbon aerogels

According to one aspect of an inventive concept, an ink includes a base catalyst, a sol gel precursor composition, and a block copolymer. According to another aspect of an inventive concept, an aerogel includes a three-dimensional printed structure having printed ligaments geometrically arranged, where an average diameter of the printed ligaments is in a range of greater than 0 microns and less than 50 microns. In addition, an average distance between a center of a first of the printed ligaments and a center of a second of the printed ligaments is at least equal to the average diameter of the printed ligaments, where the first and the second of the printed ligaments are adjacent. Each printed ligament includes of a plurality of random pores, where an average diameter of the random pores is less than 50 nanometers.

Zhu, Cheng↗

Mechanical properties of nanoporous gold in tension

We report results of the tensile properties of nanoporous gold (NPG) as a function of the density and average ligament diameter. As-dealloyed tensile samples were thermally treated to coarsen the length scale of the NPG structure while increasing the sample density resulting from thickness reductions. The behaviors of samples with mean ligament diameters ranging from 30 to 750 nm and corresponding densities ranging from 0.30 to 0.57 that of bulk gold were examined. Digital image analysis was used to obtain ligament size histograms that were fit to the Weibull distribution. The Young's modulus was found to obey a power law, but with an exponent larger than that predicted by Gibson-Ashby scaling. The fracture behavior showed a brittle-ductile transition as a function of increasing ligament size. For samples characterized by a mean ligament diameter less than ~ 220 nm, the tensile behavior was linear elastic to sample fracture while samples with larger scale ligaments showed macroscopic yielding prior to fracture. These results are interpreted within the framework of extreme value statistics.

36 MATERIALS SCIENCE↗

Bicontinuous nanoporous design induced homogenization of strain localization in metallic glasses

Bicontinuous nanoporous metallic glasses (MG) synergize the outstanding properties of MGs and open-cell nanoporous materials. The low-density and high-specific-surface-area of bicontinuous nanoporous structures have the potential to enhance the applicability of MGs in catalysis, sensors, and lightweight structural designs. In this work, we report molecular dynamics simulations of tensile loading deformation and failure of bicontinuous nanoporous Cu 64 Zr 36 MG with 55% porosity and 4.4 nm ligament size. Results indicate an anomalous mechanical behavior featuring delocalized plastic deformation preceding ductile failure. The deformation follows two mechanisms: i) Necking of ligaments aligned with the loading direction and ii) progressive alignment of randomly oriented ligaments. Failure occurs at 0.16 strain, following massive rupture of ligaments. This work indicates that a bicontinuous nanoporous design is able to effectively delocalize strain localization in a MG due to a combination of size effect on the ductility of MGs resulting in nano ligaments necking and progressive asynchronous alignment of ligaments.

36 MATERIALS SCIENCE↗

Development of a simplified procedure for thrust chamber life prediction

An analytical design procedure for predicting thrust chamber life considering cyclically induced thinning and bulging of the hot gas wall is developed. The hot gas wall, composed of ligaments connecting adjacent cooling channel ribs and separating the coolant flow from the combustion gas, is subjected to pressure loading and severe thermal cycling. Thermal transients during start up and shut down cause plastic straining through the ligaments. The primary bending stress superimposed on the alternate in-plane cyclic straining causes incremental bulging of the ligaments during each firing cycle. This basic mechanism of plastic ratcheting is analyzed and a method developed for determining ligament deformation and strain. The method uses a yield surface for combined bending and membrane loading to determine the incremental permanent deflection and pregressive thinning near the center of the ligaments which cause the geometry of the ligaments to change as the incremental strains accumulate. Fatigue and tensile instability are affected by these local geometry changes. Both are analyzed and a failure criterion developed.

Porowski, J. S.↗

Microstructure and fracture properties of open-cell porous Ti-6Al-4V with high porosity fabricated by electron beam melting

Highlights: • The Ti-6Al-4V foams with 80% high porosity are prepared by electron beam melting. • The ligament width appears to play the major role for mechanical properties. • The work of fracture is a linear function of ligament width and roughness/width ratio. - Abstract: The open-cell porous Ti-6Al-4V structure with high porosity, intended to be applied as replacement for human cancellous bone, were fabricated by electron beam melting (EBM). Computer aided design (CAD) was applied to design porous structures using the same unit cell with different unit cell sizes from 2.5 to 4 mm, different ligament widths from 600 to 900 μm, and different pore sizes from 1200 to 1800 μm, in order to achieve high porosity of 80% in avoiding the stress shielding effect. In comparison with the CAD designs and the EBM samples, there were minor discrepancies in terms of pore size and ligament width, mainly a result of melting pool. The measured data on the Young's modulus and yield strength of the EBM porous samples can be predicted by the Gibson and Ashby model. All samples with high porosity were found to match well with cancellous bone, with Young's modulus of 2 GPa and yield stress of 31 MPa, effective to diminish the risk of stress shielding effect. For porous EBM sample with high 80% porosity, the work of fracture can increase from 15.9 to 47.6 kJ/m{sup 2} with increasing ligament width from 600 to 900 μm.

36 MATERIALS SCIENCE↗

Local Measurement in Annular Flows Using a Two-Sensor Droplet-Capable Conductivity Probe

Two-sensor electrical conductivity probes have been widely used for detailed local measurement in two-phase flow systems. However application of conductivity probes in liquid-dispersed flows has been limited. In the churn-turbulent to annular transition and annular flow regimes, the liquid phase exists as a continuous phase in the film and ligaments, and as a dispersed phase in the droplets. The conventional design of a conductivity probe is not valid because it cannot distinguish the dispersed liquid phase from the gas phase. In this paper, the Two-Sensor Droplet-Capable Conductivity Probe (DCCP-2) is designed in order to extend measurement capability to liquid-dispersed flows. The liquid phase is classified into droplets and ligaments. The interface velocity, volume fraction, interfacial area concentration, as well as the chord length of liquid droplets and ligaments, can be calculated from the raw signal. The radial distribution of these parameters and the probability distribution of chord length and velocity are obtained for downwards flow in a vertical pipe. The results show that although the average volume fraction of droplets is only on the order of 1%, droplets contribute to around 20%-30% to the entrained liquid phase in the gas core, the remainder as ligaments. The interfacial area concentration from droplets and ligaments are in the order of 300 m{sup -1}. (authors)

42 ENGINEERING↗

The hepatic capsular arteries: imaging features and clinical significance

Background: Although the anatomical features of the hepatic capsular arteries have been previously reported, the radiological and clinical importance of these arteries has not been well documented. Imaging findings: We injected barium sulfate into the intra- and extra-hepatic arteries in cadavers to investigate the hepatic capsular arteries. The web-like hepatic capsular arteries derived from the capsular branch of the peripheral hepatic arteries are called isolated arteries. There were anastomoses between the intra- and extra-hepatic arteries (inferior phrenic artery, superior falciform ligament artery, and cystic artery) through the hepatic capsular arteries. Clinical significance: We reviewed the radiology database and assessed clinical cases. When the hepatic artery is occluded, the collateral vessels, such as the inferior phrenic artery and the superior falciform ligament artery, develop via the hepatic capsular arteries at the right triangular ligament and falciform ligament, respectively. Bleeding from capsular arteries causes extensions of the subcapsular hematoma. Conclusion: The hepatic capsular arteries spread along the hepatic surface and constitute the vascular network throughout the liver. These arteries play an important role in collateral circulation in various clinical situations, as well as subcapsular hematoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional grain mapping of open-cell metallic foam by integrating synthetic data with experimental data from high-energy X-ray diffraction microscopy

Highlights: • High-energy X-ray measurements are made for ligaments of an open-cell aluminum foam. • Grain centroids and orientations are measured using high-energy X-ray diffraction. • 3D grain map is virtually reconstructed by integrating measured and synthetic data. - Abstract: The complex mechanical response of open-cell foams depends strongly on the hierarchy of length scales inherent in them, from engineering-part scale to the ligament scale through the grain scale down to the crystal-lattice scale. A first step toward understanding and predicting the coordinated mechanical response across length scales requires characterizing the open-cell foam structure in three dimensions at relevant scales. Here, we present an initial attempt to digitally represent a physically-realized aluminum alloy foam in terms of both its geometry/topology as well as its underlying crystallographic orientations by integrating several advanced techniques. Specifically, we use a combination of X-ray computed tomography and X-ray diffraction microscopy in conjunction with synthetic grain mapping. Experimental investigation of the foam shows relatively large grain sizes with respect to the ligament length scale, implying that competing mechanics at different length scales (i.e. grain scale vs. ligament scale) will need to be fully incorporated to understand the mechanical behavior of the foam. The integration of non-destructive measurement techniques with synthetic-data generation provides a path toward realistic modeling of bulk samples of open-cell metal foam resolved at the scale of individual grains.

36 MATERIALS SCIENCE↗

Mapping 3D grain and precipitate structure during in situ mechanical testing of open-cell metal foam using micro-computed tomography and high-energy X-ray diffraction microscopy

Open-cell metal foams are ultra-low-density cellular metals with complex hierarchical structures that span bulk, cell, ligament, and sub-ligament scales and give rise to desirable properties such as high strength-to-weight ratio and excellent energy absorption. Although literature suggests that intrinsic material structures at sub-ligament length scales (e.g., grains and precipitates) play an important role in mechanical behavior of open-cell metal foams, there are very few experimental measurements of such structures in three dimensions and for meaningful volumes of foam. This study seeks to map and track the three-dimensional (3D) grain and precipitate structures of an intact volume of open-cell aluminum foam by advancing microstructural characterization techniques that leverage X-ray micro-computed tomography (μCT) and far-field high-energy X-ray diffraction microscopy (FF-HEDM). A 6%-relative-density aluminum foam sample was mechanically tested in compression while μCT and FF-HEDM measurements were collected at interrupted loading states at beamline 1-ID of the Advanced Photon Source. Further, a new scanning strategy and reconstruction algorithm were established to enable characterization of a foam volume with diameter approximately four times wider than the nominal width of the X-ray beam. The result is a set of maps that detail both the 3D grain and precipitate structures throughout the foam volume at successive strain steps. A novel grain tracking procedure was developed to track individual grains within the foam volume by accounting for the large rigid-body motions that individual ligaments can undergo during mechanical loading. The ability to track grains and precipitate structures in three dimensions throughout large bulk deformation of ultra-low-density polycrystalline materials enables new possibilities for validating numerical models and investigating local failure mechanisms. Furthermore, the methods and procedures developed in this study could be applied to other ultra-low-density structures, such as additively manufactured lattices.

36 MATERIALS SCIENCE↗

Turbulent mixing of a slightly supercritical van der Waals fluid at low-Mach number

Supercritical fluids near the critical point are characterized by liquid-like densities and gas-like transport properties. These features are purposely exploited in different contexts ranging from natural products extraction/fractionation to aerospace propulsion. Large part of studies concerns this last context, focusing on the dynamics of supercritical fluids at high Mach number where compressibility and thermodynamics strictly interact. Despite the widespread use also at low Mach number, the turbulent mixing properties of slightly supercritical fluids have still not investigated in detail in this regime. This topic is addressed here by dealing with Direct Numerical Simulations of a coaxial jet of a slightly supercritical van der Waals fluid. Since acoustic effects are irrelevant in the low Mach number conditions found in many industrial applications, the numerical model is based on a suitable low-Mach number expansion of the governing equation. According to experimental observations, the weakly supercritical regime is characterized by the formation of finger-like structures – the so-called ligaments – in the shear layers separating the two streams. The mechanism of ligament formation at vanishing Mach number is extracted from the simulations and a detailed statistical characterization is provided. Ligaments always form whenever a high density contrast occurs, independently of real or perfect gas behaviors. The difference between real and perfect gas conditions is found in the ligament small-scale structure. More intense density gradients and thinner interfaces characterize the near critical fluid in comparison with the smoother behavior of the perfect gas. A phenomenological interpretation is here provided on the basis of the real gas thermodynamics properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing a Spray Using Frequency-Analyzed Light Scattering

Frequency-analyzed laser-light scattering (FALLS) is a relatively simple technique that can be used to measure principal characteristics of a sheet of sprayed liquid as it breaks up into ligaments and then the ligaments break up into droplets. In particular, through frequency analysis of laser light scattered from a spray, it is possible to determine whether the laser-illuminated portion of the spray is in the intact-sheet region, the ligament region, or the droplet region. By logical extension, it is possible to determine the intact length from the location of the laser beam at the transition between the intact-sheet and ligament regions and to determine a breakup frequency from the results of the frequency analysis. Hence, FALLS could likely be useful both as a means of performing research on sprays in general and as a means of diagnostic sensing in diverse applications in which liquid fuels are sprayed. Sprays are also used for drying and to deposit paints and other coating materials.

Eskridge, Richard↗

Effect of Microstructural Parameters on the Relative Densities of Metal Foams

A detailed quantitative microstructural analyses of primarily open cell FeCrAlY and 314 stainless steel metal foams with different relative densities and pores per inch (p.p.i.) were undertaken in the present investigation to determine the effect of microstructural parameters on the relative densities of metal foams. Several elements of the microstructure, such as longitudinal and transverse cell sizes, cell areas and perimeters, ligament dimensions, cell shapes and volume fractions of closed and open cells, were measured. The cross-sections of the foam ligaments showed a large number of shrinkage cavities, and their circularity factors and average sizes were determined. The volume fractions of closed cells increased linearly with increasing relative density. In contrast, the volume fractions of the open cells and ligaments decreased with increasing relative density. The relative densities and p.p.i. were not significantly dependent on cell size, cell perimeter and ligament dimensions within the limits of experimental scatter. A phenomenological model is proposed to rationalize the present microstructural observations.

Raj, S. V.↗

Functional Adaptation of LPS-affected Dentoalveolar Fibrous Joints in Rats

We report the functional interplay between cementum of the root and alveolar bone of the socket is tuned by a uniquely positioned 70–80 µm wide fibrous and lubricious ligament in a dentoalveolar joint (DAJ). In this study, structural and biomechanical properties of the DAJ, periodontal ligament space (PDL-space also known as the joint space), alveolar bone of the socket, and cementum of the tooth root that govern the biomechanics of a lipopolysaccharide (LPS)-affected DAJ were mapped both in space and time. The hemi-maxillae from 20 rats (4 control at 6 weeks of age, 4 control and 4 LPS-affected at 12 weeks of age, 4 control and 4 LPS-affected at 16 weeks of age) were investigated using a hybrid technique; micro-X-ray computed tomography (5 µm resolution) in combination with biomechanical testing in situ. Temporal variations in bone and cementum volume fractions were evaluated. Trends in mineral apposition rates (MAR) in additional six Sprague Dawley rats (3 controls, 3 LPS-affected) were revealed by transforming spatial fluorochrome signals to functional growth rates (linearity factor - RW) of bone, dentin, and cementum using a fast Fourier transform on fluorochrome signals from 100-µm hemi-maxillae sections. An overall change in LPS-affected DAJ biomechanics (a 2.5–4.5X increase in tooth displacement and 2X tooth rotation at 6 weeks, no increase in displacement and a 7X increase in rotation at 12 weeks; 27% increase in bone effective strain at 6 weeks and 11% at 12 weeks relative to control) was associated with structural changes in the coronal regions of the DAJ (15% increase in PDL-space from 0 to 6 weeks but only 5% from 6 to 12 weeks compared to control). A significant increase (p < 0.05) in PDL-space between ligated and age-matched control was observed. The bone fraction of ligated at 12 weeks was significantly lower than its age-matched control, and no significant differences (p > 0.05) between groups were observed at 6 weeks. Cementum in the apical regions grew faster but nonlinearly (11% and 20% increase in cementum fraction (CF) at 6 and 12 weeks) compared to control. Alveolar bone revealed site-specific nonlinear growth with an overall increase in MAR (108.5 µm/week to 126.7 µm/week after LPS treatment) compared to dentin (28.3 µm/week in control vs. 26.1 µm/week in LPS-affected) and cementum (126.5 µm/week in control vs. 119.9 µm/week in LPS-affected). A significant increase in CF (p < 0.05) in ligated specimens was observed at 6 weeks of age. Anatomy-specific responses of cementum and bone to the mechano-chemo stimuli, and their collective temporal contribution to observed changes in PDL-space were perpetuated by altered tooth movement. Data highlight the “resilience” of DAJ function through the predominance of nonlinear growth response of cementum, changes in PDL-space, and bone architecture. Despite the significant differences in bone and cementum architectures, data provided insights into the reactionary effects of cementum as a built-in compensatory mechanism to reestablish functional competence of the DAJ. The spatial shifts in architectures of alveolar bone and cementum, and consequently ligament space, highlight adaptations farther away from the site of insult, which also is another novel insight from this study. These adaptations when correlated within the context of joint function (biomechanics) illustrate that they are indeed necessary to sustain DAJ function albeit being pathological.

60 APPLIED LIFE SCIENCES↗