Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIGHTING EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Performance Assessment of High-Efficiency Refrigerated Display Cases With Low Global Warming Potential Refrigerants

As California policy makers enforce new regulations such as SB 1383 to achieve state greenhouse gas reduction goals, it will be critical to understand the energy efficiency implications of low global warming potential (GWP) refrigerants in commercial refrigeration applications. The goal of this research project, funded by Commonwealth Edison, was to assess the energy performance of two high-efficiency medium-temperature, self-contained, reach-in display cases that utilized natural refrigerant propane (R-290, GWP = 3), and hydrofluorocarbon (HFC) drop-in hydrofluoroolefin R-513A (GWP = 573). Performance of these display cases was compared to a baseline fixture using HFC (R-134A, GWP = 1301) under equal conditions in a controlled environment chamber. These display cases were selected due to their widespread use in convenience stores and small supermarkets. The high-efficiency cases were equipped with energy-efficient lighting, improved panel insulation, high-efficiency evaporator and condenser fan motors, and high-effectiveness heat exchangers. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 standard method to evaluate each case under equivalent conditions (ASHRAE 2018). However, minor modifications to this methodology were implemented to better represent more realistic operation of the units. While maintaining equivalent target product temperature, the energy-efficient fixtures A (containing R-290, improved insulation, heat exchangers with a higher overall heat transfer coefficient (higher UA), and more efficient lighting and fan motors) and B (containing R-513A, improved fans, and higher UA-heat exchangers, and more efficient lighting and fan motors) consumed 61.8% to 32.6% less energy, respectively, than a baseline case using R-134A refrigerant. The daily energy consumption of the R-290, R-513A, and baseline display cases at the upper limit of environmental conditions was 4.30, 7.59, and 11.26 kWh/day, respectively.

alternative refrigerants↗

A Mobile Hot Cell for Conditioning Disused Sealed Radioactive Sources for Storage or Transportation

An innovative Mobile Hot Cell (MHC) has been developed for conditioning Disused Sealed Radioactive Sources (DSRS) category 1 and 2 for storage or transportation. The MHC is designed to provide both Radiological and Biological containment with a maximum capacity of 1000 Ci Co60 or 5000Ci Cs137 source and can be transported via standard cargo containers. This project has been supported through the National Nuclear Safety Administration (NNSA) Offsite Source Recovery Program (OSRP). The project is intended for the international community rather than domestic although domestic use is a possibility. Many countries have significant stockpiles of these devices that are often stored in less-than-optimal circumstances. This necessitates that these devices be addressed expeditiously, and the sources secured. The MHC utilizes robotics, automation, and other non-traditional methods for disassembling, characterizing, and packaging these sources that have reached end of life or are otherwise not needed. These innovative approaches are necessary to facilitate an expedited timeline to efficiently and safely secure these sources in a non-proliferation effort. Conditioning efforts include disassembling the device such as a teletherapy head used for cancer treatment, or blood/research irradiators such that the radioactive sources may be removed safely. The sources are then characterized. Leak checks are performed, dimensions are verified, and serial numbers are confirmed. Upon completion, the sources are typically placed into a Standard Forms Capsule which is seal welded closed. It is leak tested and placed into a Long-Term Storage Shield (LTSS) which can either be secured for storage directly or loaded into an appropriate cask for transportation. Further innovations include multiple deployment scenarios that include a full deployment of MHC components, deployment of the MHC automation internal components to an existing hot cell, deployment of minimally required MHC components and incorporation of sand for shielding, and integration of the MHC for Silo Storage, or Bore Hole Storage efforts. The MHC has evolved from a very specific use case to a “Swiss Army Knife” type of a tool in that it can be readily adapted to a large variety of situations. Innovative approaches such as the use of robotics, Computer Numeric Control (CNC) machining centers, automated welding equipment, HDMI Cameras, and LED lighting are some of the developed technologies incorporated into the MHC design. Shielding is accomplished with a steel walled Base Box which is surrounded by four nesting doll shield shells which when combined limits the external dose rate to 5mr/hr when a 1000 Ci Co60 source is exposed inside.

99 - GENERAL AND MISCELLANEOUS↗

Model predictive control for integrated control of air-conditioning and mechanical ventilation, lighting and shading systems

Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100 Mo. It will operate at ~10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100 Mo-enriched Li 2 MoO 4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70–90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained high energy resolutions at the 356 keV line from a 133 Ba source, as good as Ge semiconductor γ detectors in this energy range.

47 OTHER INSTRUMENTATION↗

Verification of a Modeling Toolkit for the Design of Building Electrical Distribution Systems

DC electrical distribution systems offer many potential advantages over their AC counterparts. They can facilitate easier integration with distributed energy resources, improve system energy efficiency by eliminating AC/DC converters at end-use devices (e.g., laptop chargers), and reduce installation material, time, and cost. However, DC electrical distribution systems present additional design considerations, largely resulting from potentially greater magnitude and variation in cable losses. Modeling and simulation are rarely used to design such systems. However, the greater dependency of DC system energy efficiency on design choices such as distribution voltages, architecture, and integration of PV and BESS suggests that modeling and simulation may be required. Such system performance analysis is currently not a standard practice, in part due to limited availability and validation of capable software tools. This paper characterizes the accuracy of a Modelica-based Building Electrical Efficiency Analysis Model (BEEAM) toolkit, as a precursor for validating its use to perform system performance analysis and inform design decisions. The study builds upon previous verification research by characterizing complete systems comprised of commercially available equipment, and providing a more detailed analysis of simulation results. Five lighting systems with varying electrical distribution architectures were designed using market-available equipment, installed in a laboratory environment, modeled using BEEAM, and simulated using three Modelica integrated development environments (IDEs). Simulated and measured results were compared to characterize toolkit accuracy. Initial results revealed that simulated performance was mostly within ±5% of measured system-level and device-level performance. While simulation results were not found to be dependent on the IDE, some Modelica compiler interoperability issues were identified. Although the BEEAM toolkit showed promise for the targeted use case, further work is needed to determine whether the demonstrated 5% accuracy is sufficient for making real-world design decisions, and for BEEAM to advance from an interesting research tool to one that can impact real-world building projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗

Absolute timing calibration of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

The Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM) is designed to have a good timing capability with the mission-level requirement of 1 ms as the absolute time tagging accuracy to suffice the needs for observatory science. In the ground calibration campaign, the absolute and relative timing offsets were measured using pulsed X-rays from the modulated X-ray sources. These offsets were used to determine calibration parameters, the Resolve timing coefficients, which are used in the offline correction of event times. In the orbit, reevaluation of the timing coefficients was carried out using the Crab pulsar, which was observed in two periods, one in the performance verification phase and the other in the guest observation phase. We report the absolute timing calibration of XRISM/Resolve using the ground and in-orbit data. Although the requirement is likely satisfied with the ground parameters, the timing coefficients have been refined using the in-orbit calibration to improve the timing accuracy. In addition, for the first time, we present the interpretation of the absolute timing offset originating from the analog and digital processing of X-ray events unique to a microcalorimeter spectrometer and present a complete view of the timing error of the Resolve instrument.

Astronomy and AstroPhysics↗

Resilient, Rural, and Revolutionary: Salisbury Square's Direct-Current Affordable Microgrid Community: Preprint

The technology to interconnect buildings with a dedicated direct-current (DC) power distribution network is in place today; what is missing is a turnkey approach to designing a DC microgrid - and the business models allowing such systems to be deployed, owned, and operated at scale. To close this gap, the Salisbury Square Development Team, comprising clean-energy experts, has engineered a resilient community DC microgrid for an affordable housing community in Randolph, Vermont. Ten single-family, occupant-owned residences and 12 multifamily rental units will share locally generated and stored solar energy via a DC power distribution bus capable of operating during extended grid outages. With a DC power distribution network in place, each home will be equipped with high-efficiency DC lighting and appliances, operating alongside alternating current (AC) appliances, even during an islanded mode of operation. To obtain a comprehensive understanding of what is possible and achievable, the Team collaborated with the local utility, regulatory agencies, a national laboratory, energy-as-service providers, and vendors. The collaborators evaluated microgrid typologies, business models, and energy modeling, and analyzed electrification and resilience. Further, the Team applied the URBANoptTM (Urban Renewable Building and Neighborhood optimization, NREL 2022) software development kit (SDK) to Salisbury Square's single-family and multifamily buildings to validate workflows and identify needs for advanced capability. This paper addresses the barriers to entry, scalability, and impact on residents and system ownership. It also examines the analysis that informed the design and engineering of the DC microgrid and the opportunities to streamline the process.

DER↗

Making Better Use of On-Site PV Generation: Direct Distribution of DC Power in Buildings

With the increasing availability of Direct Current (DC) power from on-site solar systems, building designers now have the option of direct distribution of DC power to energy storage systems and end-use loads such as lighting, electronics, and motors. Research shows that direct-DC can reduce building distribution losses by 5-15%, while improving power reliability. A readily available way to implement direct-DC distribution is Power over Ethernet (PoE), which typically has provided low-voltage DC to power office equipment such as WiFi access points. With recent updates to the PoE standard, equipment such as network-controlled LED lighting, thin client and computer workstations, HVAC controllers, fans, motors, and actuators can now be powered by PoE and are commercially available. This paper presents results from a DOE-funded project that is demonstrating PoE technologies and describes a DC modeling and design tool that is intended to help building designers properly evaluate and design DC distribution systems in buildings. The tool provides designers of DC power systems with estimates of both power system losses and indirect effects on building heating and cooling. The results of this research demonstrate that the design methods and products are available to implement DC power in buildings today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The spore coat is essential for Bacillus subtilis spore resistance to pulsed light, and pulsed light treatment eliminates some spore coat proteins

Microbial surface contamination of equipment or of food contact material is a recurring problem in the food industry. Spore-forming bacteria are far more resistant to a wide variety of treatments than their vegetative forms. Understanding the mechanisms underlying decontamination processes is needed to improve surface decontamination strategies against endospores potentially at the source of foodborne diseases or food-spoilage. Pulsed light (PL) with xenon lamps delivers high-energy short-time pulses of light with wavelengths in the range 200 nm-1100 nm and a high UV-C fraction. Bacillus subtilis spores were exposed to either PL or to continuous UV-C. Gel electrophoresis and western blotting revealed elimination of various proteins of the spore coat, an essential outer structure that protects spores from a wide variety of environmental conditions and inactivation treatments. Proteomic analysis confirmed the elimination of some spore coat proteins after PL treatment. Transmission electron microscopy of PL treated spores revealed a gap between the lamellar inner spore coat and the outer spore coat. Overall, spores of mutant strains with defects in genes coding for spore coat proteins were more sensitive to PL than to continuous UV-C. This study demonstrates that radiations delivered by PL contribute to specific damage to the spore coat, and overall to spore inactivation. Keywords Decontamination, UV, proteins, proteomics, microscopy Journal Pre-proof

59 BASIC BIOLOGICAL SCIENCES↗

Signal Processing of Multiplexed Optical PWM Signals for Sensor Arrays in Nuclear Environments

Safe and effective generation of terrestrial nuclear power greatly benefits from the actionable data provided by the array of sensors located throughout a plant to provide a holistic online indication of reactor operation. This array includes sensors for monitoring coolant flow and pressure, temperature and heat transfer, radiation levels, structure health monitoring, and other critical parameters for reactor operation. While sensors capable of measuring these parameters have been developed, the electronics used in the pre-amplification and analog-to-digital conversion of the small signals they produce are extremely sensitive and susceptible to damage by high-temperatures and radiation environments nuclear reactors encounter while generating power. The small signals from sensors in nuclear power plants (NPPs) are transmitted over long cable runs which introduce dispersion artifacts into the signals of interest as well as electromagnetic interference (EMI) from lighting fixtures, pumps, mains electricity, and other equipment. To overcome these challenges, a front-end digitization (FREND) platform has been developed to use radiation-tolerant electronics to multiplex, amplify, and optically encode signals from an array of sensors for transmission over an optical fiber to mitigate dispersion and EMI artifacts from long runs of electrical cabling. To recover the optically transmitted data, a signal processing scheme based on 1-dimensional template matching to an indexing channel is described herein and demonstrated to have an effective bit-depth of 9.2 bits (1%). This scheme has been validated in proof-of-concept, non-nuclear testing and preliminary experimental results show good agreement between the measured optical output and and sensor input signals. The FREND system represents a low-loss data link between sensors in nuclear environments and data acquisition hardware which is aimed at improving the signal-to-noise ratio of the data acquired from these sensors to provide better information to operators and researchers.

Sweeney, Dan↗

Near-MHz temperature and H 2 O measurements in post-detonation fireballs of 25 g hemispherical explosives using scanned-wavelength-modulation spectroscopy

A laser absorption spectroscopy diagnostic integrated within a hardened optical probe was used to measure temperature and water mole fraction at 500 kHz in post-detonation fireballs of explosives. In the experiments, an exploding-bridgewire detonator initiated a 25 g hemisphere of explosive (N5 or PETN). This produced a hemispherical fireball that traveled radially towards a hardened measurement probe. The probe contained a pressure transducer and optical equipment to pitch fiber-coupled laser light across a 12.6 cm gap onto a detector. Tunable diode lasers emitting near 7185.6 and 6806 c m − <#comment/> 1 were used to measure the absorbance spectrum of H 2 O utilizing peak-picking scanned-wavelength-modulation spectroscopy with a scan frequency of 500 kHz and modulation frequencies of 35 and 45.5 MHz, respectively. This enabled measurements of temperature and X H 2 O in the shock-heated air and trailing fireball at 500 kHz. Time histories of pressure, temperature, and H 2 O mole fraction were acquired at different standoff distances to quantify how the fireball evolved in space and time as well as to compare measured quantities between PETN and N5 fireballs. The standard deviation of temperature and X H 2 O during one representative test were found to be 17 K (1.3%) and 0.011 (5%), respectively. These measurements demonstrate this diagnostic’s ability to provide rapid and reliable measurements in harsh, highly transient post-detonation environments produced by solid explosives.

Schwartz, Charles J.↗

Energy Efficiency Assistance for Galena Alaska

The City of Galena sits along the north bank of the Yukon River with no road access. Temperatures regularly reach negative 20°F in the winter and sunlight extends for up to 21 hours a day in the summer. Galena’s 400 residents, including members of the Koyukuk Athabascan culture, primarily use fuel oil and locally forested wood for heating and electricity generation. Because these resources are costly to obtain, local households have a high energy burden, spending 7% of their annual income on energy (averaging $4,000 per year). To reduce this burden, the City of Galena joined the U.S. Department of Energy’s (DOE) Remote Alaska Community Energy Efficiency (RACEE) Competition, where they received financial and technical assistance to implement energy savings solutions across their community, including building envelope improvements, solar panels, and LED lighting. Additionally, Galena installed new energy monitoring equipment to continue measuring the impacts of this work beyond the RACEE project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Files for 'The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure'

This data set includes modeling results from The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure, including region-specific (i.e., national, state, and core-based statistical area cities and towns) electric vehicle supply equipment port count requirements in 2025 and 2030 for multiple scenarios described in the study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Files for "The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure"

This dataset includes modeling results from The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure, including region-specific (i.e., national, state, and core-based statistical area [cities and towns]) electric vehicle supply equipment port count requirements in 2025 and 2030 for multiple scenarios described in the study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Physical and Operational Status of the Photovoltaic Systems in the Municipality of Pinotepa de Don Luis, Oaxaca, One Year after Their Installation [Estado fisico y operativo de los sistemas fotovoltaicos en el municipio de Pinotepa de Don Luis, Oaxaca un ano despues de su instalacion]

In November 1990, an inspection visit was made to the residential lighting photovoltaic systems that had been installed approximately one year before in the rural communities of the Municipality of Pinotepa de Don Luis, in the State of Oaxaca. The main purpose of the visit was to evaluate the physical and operational status of these systems. The systems typically consist of a photovoltaic module with a capacity of 30 or 35 Watts, an automotive type battery, an indicator of the status of charge of the battery, 3 fluorescent lamps and the corresponding installation, including cables, connection or outlet box and switches. It can be seen that the systems are in good physical condition and do not show any signs of intentionally caused damage. However, the incidence of failures is higher than what had been expected; therefore the operational status of these systems is considered to be below a level that could be accepted, with a tendency to getting worse. The main problem that has been detected is the lack of automatic charge controllers. This problem has caused other important failures. Serious deficiencies were appreciated in the installations, which show evidence of the poor workmanship of the installers. The lack of system standardization is evident, both regarding the components and the installation. As a consequence, there are technical factors which indicate that the installed systems will keep deteriorating at a rate faster than normal, and will stop operating in a short time unless urgent preventive and corrective measures are taken. The attitude of the users with respect to the systems is generally positive. However, there are elements that make the correct operation and maintenance of these systems a very difficult task. The users did not receive any training regarding the best way to operate and take care of their systems, nor any other information in relation to their technical limitations.

14 SOLAR ENERGY↗

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING↗

Commissioning of the large-scale lead tungstate scintillating calorimeter

Here, we report on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises 1596 high-granularity, high-resolution scintillating crystals optimized for electromagnetic-shower detection over a wide energy range. Scintillation light from each crystal is read out by Hamamatsu R4125 photomultiplier tubes equipped with a custom voltage divider and front-end amplifier to ensure stable gain at high rates. All calorimeter modules were fabricated and characterized using a light-emitting diode–based optical test system prior to installation to verify uniformity and photodetector performance. After installation, the electromagnetic calorimeter was fully integrated into the experiment data acquisition and energy-based trigger systems. The optical response of the modules was equalized using the light-monitoring system, cosmic-ray muons, and photons from Compton-scattering events. Commissioning results demonstrate a reliably calibrated optical response and stable detector performance during the first run. These results validate the calorimeter design and commissioning methodology for large-scale scintillator-based photonic instrumentation.

Analog to digital converters↗