Imaging of Hydrogen Peroxide and Methyl in Nanosecond Pulsed Plasmas by Photofragmentation Laser-Induced Fluorescence.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Apparatus include divergence optics removably coupled to receive a probe beam in a first imaging mode to cause the probe beam to diverge before impinging on a first area of a target surface, and to not receive the probe beam in a second imaging mode to cause the probe beam to impinge on a second area of the target surface smaller than the first area, collection optics configured to receive, in response to the probe beam, luminescence light emitted from the first area and spectral light emitted from the second area, and an optical detector coupled to the collection optics, wherein the optical detector includes a luminescence imaging detector portion and a spectral imaging detector portion adjacent to the luminescence imaging detector portion, wherein the luminescence imaging detector portion is configured to receive the luminescence light emitted from the first area and the spectral imaging detector portion is configured to receive the spectral light from the second area.
Objective of the current study: Characterize the combustion chemistry and flashback events observed in a swirl-stabilized atmospheric-pressure burner in hydrogen-enriched flames. A high-speed ns-based OH-PLIF diagnostic imaging technique is used.
Conference abstract being submitted by the University of Michigan in collaboration with INL
Atmospheric pressure plasma jets have great potential for the surface modification of polymers. In this work, the authors report on polystyrene etching by a radio frequency driven atmospheric pressure plasma jet with a focus on the role of H · , O · , and · OH radicals in this process. The absolute flux of H · , O · , and · OH radicals reaching the surface of the polymer was determined by a COMSOL MULTIPHYSICS reacting fluid dynamics model incorporating detailed transport phenomena in the boundary layer near the substrate. The simulated results of H · and · OH densities in the jet effluent were experimentally verified by two-photon absorption laser induced fluorescence and laser induced fluorescence, respectively. The carbon atom removal flux from the polystyrene surface was taken from previously reported measurements using the same plasma source. The authors show that the boundary layer effects in the interfacial region above the substrate can have a significant impact on the calculated etching probabilities. The reaction probability (β) has a significant uncertainty although a variation of 2 orders of magnitude in β leads to uncertainties of approximately 1 order of magnitude variation in the determined etching probability. The etching probability of polystyrene by · OH radicals was confirmed to be at least an order of magnitude larger than the polystyrene etching probability by O · radicals. The authors also confirmed the weak polystyrene etching probability by H · radicals. The model suggests that the presence of a 30 ppm O 2 impurity can lead to the production of · OH radicals in the far effluent of the Ar + 1% H 2 plasma jet close to the substrate at sufficient densities to enable effective etching.
We report isotopic shifts and hyperfine structures of selected U transitions employing tunable spectroscopy viz: laser-induced fluorescence and laser absorption spectroscopy of laser ablation plumes. The laser-produced plasmas were produced during ns laser ablation on a natural U metal which contains 0.7% 235U. Our results show that isotopic shifts between 238U and 235U are entangled with hyperfine structures of 235U. The isotopic ratio obtained using laser-induced fluorescence is affected by optical saturation effect. Time-resolved laser absorption spectroscopy is carried out for evaluating the optical absorption and estimating the hyperfine constants.
Understanding the fundamental properties of metal-halide perovskite materials is driving the development of novel optoelectronic applications. Here, in this paper, we report the observation of a recoverable laser-induced fluorescence quenching phenomenon in perovskite films with a microscopic grain-scale restriction, accompanied by spectral variations. This fluorescence quenching depends on the laser intensity and the dwell time under Auger recombination dominated conditions. These features indicate that the perovskite lattice deformation may take the main responsibility for the transient and show a new aspect to understand halide perovskite photo-stability. We further modulate this phenomenon by adjusting the charge carrier recombination and extraction, revealing that efficient carrier transfer can improve the bleaching resistance of perovskite grains. Our results provide future opportunities to attain high-performance devices by tuning the perovskite lattice disorder and harvesting the energetic carriers.
The adoption of Generation IV molten salt reactors (MSRs) depends on the ability to implement compatible monitoring instrumentation to ensure adherence to nuclear safeguards. This task is nontrivial due to the high temperature, reactive, and chemically complex fuel and coolant components contained within these systems. Optical spectroscopy techniques such as laser-induced fluorescence (LIF) and laser-induced breakdown spectroscopy (LIBS) are candidates for monitoring instrumentation. They offer many advantages for continuous monitoring, including the ability to operate at a standoff and compatibility with liquid-phase analytes. We discuss the use of LIF for the detection of Nd, a common fission fragment, within a liquid matrix. Results show that for NdCl3 dissolved in water, the Nd I 492.45 nm resonant transition is detectable without the need to induce a plasma and that the fluorescence emission can be separated in the time domain from the laser scatter signal. Additionally, we present a setup and preliminary results for measurements of solid Nd and U using resonant LIBS. The results demonstrate element-selective measurement capabilities and provide the foundational data necessary to continue the development of laser-based MSR diagnostics. This work also helps address gaps in the literature regarding energy level assignments of Nd.
Here we have observed the behavior of striations caused by ionization waves propagating in low-pressure helium DC discharges using the non-invasive laser-collision induced fluorescence (LCIF) diagnostic. To achieve this, we developed an analytic fit of collisional radiative model (CRM) predictions to interpret the LCIF data and recover quantitative two-dimensional spatial maps of the electron density, n e , and the ratios of LCIF emission states that can be correlated with T e with the use of accurate distribution functions at localized positions within striated helium discharges at 500 mTorr, 750 mTorr, and 1 Torr. To our knowledge, these are the first spatiotemporal, laser-based, experimental measurements of n e in DC striations. The n e and 447:588 ratio distributions align closely with striation theory. Constriction of the positive column appears to occur with decreased gas pressure, as shown by the radial n e distribution. We identify a transition from a slow ionization wave to a fast ionization wave between 750 mTorr and 1 Torr. These experiments validate our analytic fit of n e , allowing the implementation of an LCIF diagnostic in helium without the need to develop a CRM.
Dielectric barrier discharges, particularly micro cavity plasma arrays, offer significant potential for plasma-catalytic research due to their ability to ignite plasma in direct contact with a catalytic surface, enabling the observation of plasma-surface interactions. A key factor in their application is the generation of reactive species, such as atomic oxygen, within the cavities. These species can interact with both the surface (e.g. for activation or cleaning) and the gas being treated (e.g. for oxidation). Given the central role of oxygen atoms in plasma catalysis and their use as a model for more complex species, this work investigates the transport of these atoms out of the cavities. Two-photon absorption laser-induced fluorescence spectroscopy with picosecond laser excitation is performed in the volume above the cavities. The results are compared with a basic diffusion model. The reactor operates with a He/O 2 mixture at a flow rate of 1 slm and atmospheric pressure. Densities of up to 10 16 cm -3 are measured near the surface. Time-dependent measurements show that, at a distance of 350 µm from the surface, a density equilibrium is reached within less than 3 ms of reactor operation. Decay times due to ozone formation after the reactor is turned off are on a similar scale. Spatially resolved measurements show that the oxygen density decreases exponentially from the surface but remains detectable up to approximately 1 mm above the surface, indicating significant application potential. Variations in the O 2 admixture show a density maximum at 0.4%, confirming previous helium state enhanced actinometry measurements within the cavities.
Vibrational kinetics of O 2 is studied during the O atom recombination in an O 2 –Ar mixture, partially dissociated by a burst of ns discharge pulses in a heated plasma flow reactor. The time-resolved temperature in the discharge afterglow is determined by Rayleigh scattering. Time-resolved O atom number density is measured by ps Two-Photon absorption Laser Induced Fluorescence, calibrated in xenon. Time-resolved vibrational level populations of molecular oxygen, O 2 (v= 8–20), are measured by ps Laser Induced Fluorescence (LIF), with the absolute calibration by NO LIF. Time-resolved ozone number density is monitored by broadband UV absorption. The results are compared with the predictions of a state-specific kinetic model. The experimental data indicate a rapid initial decay of O 2 (v) populations generated by electron impact in the discharge, due to the vibration-translation (V–T) relaxation by O atoms. This is followed by a slower population reduction, on the time scale much longer compared to that for V–T relaxation or vibration-vibration (V–V) exchange. Both O atoms and the O 2 (v) populations decay on the same time scale, indicating that chemical reactions initiated by the O atom recombination result in the generation of vibrationally excited O 2 molecules. These trends are reproduced by the kinetic model, which shows that the reaction of O atoms with ozone is the dominant pathway of O 2 (v) generation at the present conditions. The predicted relative O 2 (v) populations are close to the experimental results, but absolute number densities differ from the experimental data. This is likely due to uncertainties in the absolute calibration of LIF measurements and in the spectroscopic model used in the data reduction. The present work demonstrates the capability for the absolute, time-resolved measurements of vibrationally excited O 2 in recombining gas flows, to quantify the energy partition in the recombination reactions.
In this work, we provide experimental measurements of the E X B flow above a non-magnetic, absorbing boundary in a magnetized plasma. Measurements are taken as a function of the angle between the background magnetic field and the boundary normal. The measurements are compared to computational predictions for oblique magnetic fields based on Chodura's model. Ion flow measurements were obtained with laser induced fluorescence and the presheath potential structure was measured with an emissive probe. The ions were found to accelerate to nearly 30% of the sound speed parallel to the boundary at oblique angles of the magnetic field (~80°) and the ion speed at the electrostatic sheath edge was found to decrease with angle. The edge of the magnetic presheath has been experimentally determined based on the appearance of the E X B drift and is found to be independent of the angle of the magnetic field. We also demonstrate that laser induced fluorescence is suitable as a non-perturbative diagnostic to measure the electric field in a magnetized sheath.
In this Letter, we present a particle image/tracking velocimetry (PIV/PTV) technique for simultaneous velocity measurement of both fluid and particle phases, adopting newly developed optical phase discrimination methods and novel optical particles. Spherical acrylic (PMMA) particles of diameter ∼ <#comment/> O ( 100 µ <#comment/> m ) were used as the particle phase, while fine B A M : E u 2 + phosphors of diameter ∼ <#comment/> O ( 1 µ <#comment/> m ) were used as the fluid tracer. Under Nd:YAG 355 nm laser excitation, both the laser-induced fluorescence (LIF) from PMMA and laser-induced phosphorescence (LIP) from B A M : E u 2 + provided sufficiently strong signals for PIV imaging with two non-intensified cameras and were clearly separable for phase discrimination using spectral filters and temporal profiles. The advantages of the PIV/PTV method include the relatively low cost of B A M : E u 2 + phosphors, high sphericity and narrow size distribution of PMMA particles with LIF emission, and direct optical discrimination eliminating artifacts, while requiring much less computational capacity for PIV/PTV processing of complex particle-laden flows.
This article will review two popular methods of laser diagnostics in a plasma–liquid system and generally in low-temperature plasmas. These are Thomson scattering and laser-induced fluorescence. Setting up the plasma–liquid interaction experiment will be described while stressing the important points for laser diagnostics and maintaining conditions for correct and repeatable measurements. In this work, I will discuss the caveats that are encountered when measuring an inherently unstable and collisional system, such as plasma interacting with the liquid and how these challenges impact that data analysis and calibration efforts for these two-diagnostic approaches.
Los Alamos National Laboratory designed a compact laser-induced fluorescence imaging camera with Raman spectrometer to identify organic molecules and biosignatures in environments such as Martian caves, icy-moons, and asteroid surfaces. OrganiCam is the primary instrument on the Laser-Induced Fluorescence Exploration of Caves for Organics and Volatiles using an Elevated Platform (LIFE COVE) NASA mission concept. OrganiCam could also determine if instruments being sent into space for NASA are sterile and analyze samples returned to Earth. OrganiCam’s robust design for extreme environments, portability, simple operation, and low power requirement build on LANL’s 50+ years designing robotic instruments for space applications.
Hydrogen (H 2 ), as a carbon-free fuel, is considered as one of the most promising solutions to reduce the carbon footprint of hard-to-decarbonize energy and transportation sectors. As such, hydrogen-fueled internal combustion engines (H 2 ICEs) have recently been receiving increasing attention, particularly in applications such as on-road/off-road heavy-duty transport and combined heat and power. The direct injection (DI) of gaseous hydrogen into the combustion chamber offers great potential for achieving high power density and high engine efficiency, while mitigating the risk of backfire and reducing pre-ignition. However, the numerical simulation of H 2 DI system remains a formidable challenge associated with the high computational cost of reproducing compressible supersonic flow and shocks in narrow injector passages and in near-nozzle regions. In general, there is a lack of well-established and validated practices for the modeling of high-pressure H 2 DI in large-bore engines. Here, to this end, this study focuses on computational fluid dynamics (CFD) modeling of the mixture formation process in a heavy-duty optical engine employing a medium-pressure H 2 DI system. Both large eddy simulations (LES) and Reynolds Averaged Navier–Stokes (RANS) simulations are performed and evaluated against optical data. Gaseous hydrogen is injected into the combustion chamber via a centrally located outward opening hollow-cone injector at a pressure of 40 bar. Simulations are carried out for two injection timings, namely, −120 and −60 °CA. The numerical predictions for H 2 distribution in different horizontal and vertical planes during the compression stroke are systematically compared against optical data obtained through planar laser-induced fluorescence (PLIF) measurements. Overall, the LES approach using the Dynamic Structure model is found to have good predictive capabilities for the early jet penetration in terms of length and shape, as well as the later H 2 distributions. However, the unsteady RANS approach with the renormalization group $k - ϵ$ model, which is widely used by industry to model heavy-duty ICEs, significantly underpredicts the H 2 mixing, even at similar mesh resolution to that used in LES. These results indicate that there is a need for the improvement of mixing submodels within the RANS approach when applied to H 2 DI simulations.