Search NASA⌕ Search

SEARCH · Search NASA

Results for “Latex”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Effect of Fatty Acid Polyunsaturation on Synthesis and Properties of Emulsion Polymers Based on Plant Oil-Based Acrylic Monomers

This study demonstrated that polymerization behavior of plant oil-based acrylic monomers (POBMs) synthesized in one-step transesterification reaction from naturally rich in oleic acid olive, canola, and high-oleic soybean oils is associated with a varying mass fraction of polyunsaturated fatty acid fragments (linoleic (C18:2) and linolenic (C18:3) acid esters) in plant oil. Using miniemulsion polymerization, a range of stable copolymer latexes was synthesized from 60 wt.% of each POBM and styrene to determine the impact of POBM chemical composition (polyunsaturation) on thermal and mechanical properties of the resulted polymeric materials. The unique composition of each plant oil serves as an experimental tool to determine the effect of polyunsaturated fatty acid fragments on POBM polymerization behavior and thermomechanical properties of crosslinked films made from POBM-based latexes. The obtained results show that increasing polyunsaturation in the copolymers results in an enhanced crosslink density of the latex polymer network which essentially impacts the mechanical properties of the films (both Young’s modulus and toughness). Maximum toughness was observed for crosslinked latex films made from 50 wt.% of each POBM in the monomer feed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Retractor Tool for Brain Surgery

Proposed brain-surgery tool has an octogonal fixture for positioning latex tube over incision. Eight stainless-steel wires embedded in latex extend to hold positioning fixture. Another eight are also embedded in the latex. Concentric sleeves are successively inserted into expandable latex tube. The first sleeve is placed over a solid rod. Last sleeve is a stainless-steel tube 1 inch in diameter. It is overcoated with Teflon (or equivalent) material.

Helms, R.↗

Complete coverage fouling model for constant flux crossflow ultrafiltration and experimental validation

A complete coverage model is proposed to describe fouling in constant flux crossflow ultrafiltration. Constant flux crossflow fouling experiments were conducted using dilute latex bead suspensions and commercial poly(ether sulfone) flat sheet ultrafiltration membranes to investigate the influence of operating conditions on evolution of transmembrane pressure (ΔP, TMP) with time. Changes in permeate flux or crossflow rate had little influence on the normalized TMP profile at high latex bead concentration (i.e., above 25 ppm) because the membrane surface was covered with latex beads. At low concentration (i.e., below 25 ppm), increases in permeate flux or foulant concentration increased normalized ΔP. However, this increase in normalized ΔP with permeate flux or foulant concentration diminishes when the permeate flux/concentration is high enough to overwhelm particle removal due to crossflow. Furthermore, these results are in good agreement with the new complete coverage model which describes the influence of operating parameters on fouling better than the previous model.

36 MATERIALS SCIENCE↗

Accumulation of high-value bioproducts in planta can improve the economics of advanced biofuels

Coproduction of high-value bioproducts at biorefineries is a key factor in making biofuels more cost-competitive. One strategy for generating coproducts is to directly engineer bioenergy crops to accumulate bioproducts in planta that can be fractionated and recovered at biorefineries. Here, we develop quantitative insights into the relationship between bioproduct market value and target accumulation rates by investigating a set of industrially relevant compounds already extracted from plant sources with a wide range of market prices and applications, including <$10/kg (limonene, latex, and polyhydroxybutyrate [PHB]), $10 to $100/kg (cannabidiol), and >$100/kg (artemisinin). These compounds are used to identify a range of mass fraction thresholds required to achieve net economic benefits for biorefineries and the additional amounts needed to reach a target $2.50/gal biofuel selling price, using cellulosic ethanol production as a test case. Bioproduct market prices and recovery costs determine the accumulation threshold; we find that moderate- to high-value compounds (i.e., cannabidiol and artemisinin) offer net economic benefits at accumulation rates of just 0.01% dry weight (dwt) to 0.02 dwt%. Lower-value compounds, including limonene, latex, and PHB, require at least an order-of-magnitude greater accumulation to overcome additional extraction and recovery costs (0.3 to 1.2 dwt%). We also find that a diversified approach is critical. For example, global artemisinin demand could be met with fewer than 10 biorefineries, while global demand for latex is equivalent to nearly 180 facilities. Our results provide a roadmap for future plant metabolic engineering efforts aimed at increasing the value derived from bioenergy crops.

09 BIOMASS FUELS↗

Development of a special purpose spacecraft interior coating, phase 1

Coating formulations were developed consisting of latex blends of fluorocarbon polymers, acrylic resins, stabilizers, modifiers, other additives, and a variety of inorganic pigments. Suitable latex primers were also developed from an acrylic latex base. The formulations dried to touch in about one hour and were fully dry in about twenty-four hours under normal room temperature and humidity conditions. The resulting coatings displayed good optical and mechanical properties, including excellent bonding to (pre-treated) substrates. In addition, the preferred compositions were found to be self-extinguishing when applied to nonflammable substrates and could meet the offgassing requirements specified by NASA for the intended application. Improvements are needed in abrasion resistance and hardness.

Bartoszek, E. J.↗

Fast-drying coating

Nontoxic coating has excellent optical properties and can be pigmented in many different colors. It bonds well, can be applied by conventional methods, weathers well, and is self-extinguishing. Coating composition comprises latex blends of fluorocarbons, acrylic resins, stabilizers, modifiers, variety of inorganic pigments, and other additives. Suitable latex primers have also been developed from acrylic latex base.

Bartoszek, E. J.↗

Electrokinetic properties of polymer colloids

The surface of polymer colloids, especially polystyrene latexes, were modified for the purpose of controlling the electrokinetic properties of the resulting colloids. Achievement required a knowledge of electrical double layer charging mechanism, as a function of the electrolyte conditions, at the polymer/water interface. The experimental approach is to control the recipe formulation in the emulsion polymerization process so as to systematically vary the strong acid group concentration on the surface of the polymer particles. The electrophoretic mobility of these model particles will then be measured as a function of surface group concentration and as a function of electrolyte concentration and type. An effort was also made to evaluate the electrophoretic mobility of polystyrene latexes made in space and to compare the results with latexes made on the ground.

Micale, F. J.↗

Contamination of Critical Surfaces from NVR Glove Residues Via Dry Handling and Solvent Cleaning

Gloves are often used to prevent the contamination of critical surfaces during handling. The type of glove chosen for use should be the glove that produces the least amount of non-volatile residue (NVR). This paper covers the analysis of polyethylene, nitrile, latex, vinyl, and polyurethane gloves using the contact transfer and gravimetric determination methods covered in the NASA GSFC work instruction Gravimetric Determination and Contact Transfer of Non-volatile Residue (NVR) in Cleanroom Glove Samples, 541-WI-5330.1.21 and in the ASTM Standard E-1731M-95, Standard Test Method for Gravimetric Determination of Non-Volatile Residue from Cleanroom Gloves. The tests performed focus on contamination of critical surfaces at the molecular level. The study found that for the most part, all of the gloves performed equally well in the contact transfer testing. However, the polyethylene gloves performed the best in the gravimetric determination testing, and therefore should be used whenever solvent contact is a possibility. The nitrile gloves may be used as a substitute for latex gloves when latex sensitivity is an issue. The use of vinyl gloves should be avoided, especially if solvent contact is a possibility. A glove database will be established by Goddard Space Flight Center (GSFC) Code 541 to compile the results from future testing of new gloves and different glove lots.

Sovinski, Marjorie F.↗

Mapping Structure and Rheology of pH-Responsive Resins for Low-VOC Coatings

In recent years, the paint and coatings industry has shifted away from traditional resin formulations that require high concentrations of volatile organic compounds (VOCs) to achieve the desired rheological performance and sustainability targets. One approach to eliminate or reduce VOCs in paint and coating formulations while maintaining the final performance is to disperse stimuli-responsive polymer latex particles in water. The chemistry and architecture of these particles have been engineered such that the suspension rheology changes in response to the pH changes. The particles can also be swollen with organic solvents to illicit similar rheological changes. To understand how the particle microstructure influences the observed macroscopic properties, we use small-angle neutron scattering and dynamic light scattering to determine that these particles consist of a cross-linked core with long polymer tails that extend into the dispersing medium. Carboxylic acid groups present on the tails deprotonate with increasing pH, and the extension of the polymer chain due to charge repulsion increases the hydrodynamic drag on the particle. Here we find that adjusting the pH alone has a much more significant effect on the shear dependence of the viscosity of the studied resin than adding organic solvent alone. We also find that this resin architecture is more responsive per mole of pH-responsive group than other architectures of pH-responsive latex particles in the literature.

36 MATERIALS SCIENCE↗

Effect of Temperature on Thrombogenicity Testing of Biomaterials in an In Vitro Dynamic Flow Loop System

To develop and standardize a reliable in vitro dynamic thrombogenicity test protocol, the key test parameters that could impact thrombus formation need to be investigated and understood. In this study, we evaluated the effect of temperature on the thrombogenic responses (thrombus surface coverage, thrombus weight, and platelet count reduction) of various materials using an in vitro blood flow loop test system. Whole blood from live sheep and cow donors was used to assess four materials with varying thrombogenic potentials: negative-control polytetrafluoroethylene (PTFE), positive-control latex, silicone, and high-density polyethylene (HDPE). Blood, heparinized to a donor-specific concentration, was recirculated through a polyvinyl chloride tubing loop containing the test material at room temperature (22–24°C) for 1 hour, or at 37°C for 1 or 2 hours. The flow loop system could effectively differentiate a thrombogenic material (latex) from the other materials for both test temperatures and blood species ( p < 0.05). However, compared with 37°C, testing at room temperature appeared to have slightly better sensitivity in differentiating silicone (intermediate thrombogenic potential) from the relatively thromboresistant materials (PTFE and HDPE, p < 0.05). These data suggest that testing at room temperature may be a viable option for dynamic thrombogenicity assessment of biomaterials and medical devices.

Engineering↗

Comparison of animal and human blood for in vitro dynamic thrombogenicity testing of biomaterials

Abstract Background To determine suitable alternatives to human blood for in vitro dynamic thrombogenicity testing of biomaterials, four different animal blood sources (ovine, bovine, and porcine blood from live donors, and abattoir porcine blood) were compared to fresh human blood. Methods To account for blood coagulability differences between individual donors and species, each blood pool was heparinized to a donor‐specific concentration immediately before testing in a dynamic flow loop system. The target heparin level was established using a static thrombosis pre‐test. For dynamic testing, whole blood was recirculated at room temperature for 1 h at 200 ml/min through a flow loop containing a single test material. Four materials with varying thrombotic potentials were investigated: latex (positive control), polytetrafluoroethylene (PTFE) (negative control), silicone (intermediate thrombotic potential), and high‐density polyethylene (HDPE) (historically thromboresistant). Thrombus weight and surface area coverage on the test materials were quantified, along with platelet count reduction in the blood. Results While donor‐specific heparin levels varied substantially from 0.6 U/ml to 7.0 U/ml among the different blood sources, each source was able to differentiate between the thrombogenic latex and the thromboresistant PTFE and HDPE materials ( p < 0.05). However, only donor ovine and bovine blood were sensitive enough to differentiate an increased response for the intermediate thrombotic silicone material compared to PTFE and HDPE. Conclusions These results demonstrated that multiple animal blood sources (particularly donor ovine and bovine blood) may be suitable alternatives to fresh human blood for dynamic thrombogenicity testing when appropriate control materials and donor‐specific anticoagulation levels are used.

Engineering↗

In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples

Abstract The results of in vitro dynamic thrombogenicity testing of biomaterials and medical devices can be significantly impacted by test conditions. To develop and standardize a robust dynamic in vitro thrombogenicity tool, the key test parameters need to be appropriately evaluated and optimized. We used a flow loop test system previously developed in our laboratory to investigate the effects of sample length and the number of samples per test loop on the thrombogenicity results. Porcine blood heparinized to a donor-specific target concentration was recirculated at room temperature through polyvinyl chloride (PVC) tubing loops containing test materials for 1 h at 200 mL/min. Four test materials (polytetrafluoroethylene (PTFE), latex, PVC, and silicone) with various thrombotic potentials in two sample lengths (12 and 18 cm) were examined. For the 12-cm long materials, two different test configurations (one and two samples per loop) were compared. Thrombogenicity was assessed through percent thrombus surface coverage, thrombus weight, and platelet count reduction in the blood. The test system was able to effectively differentiate the thrombogenicity profile of the materials (latex > silicone > PVC ≥ PTFE) at all test configurations. Increasing test sample length by 50% did not significantly impact the test results as both 12 and 18 cm sample lengths were shown to equally differentiate thrombotic potentials between the materials. The addition of a second test sample to each loop did not increase the test sensitivity and may produce confounding results, and thus a single test sample per loop is recommended.

Engineering↗

ICSBEP Benchmark Template

The purpose of this document is to demonstrate the ability of LATEX to create an ICSBEP benchmark evaluation. Creating a large document in LATEX offers many benefits, such as automatic numbering of items such as tables and figures, and easier placement of objects in the page. Additionally, it is easier to have multiple styles of pages in the same document, and in general the handling of large documents (which evaluations very commonly are) is not problematic. The formatting of this document is meant to conform to both the standards of the document and formatting guide and established practices in order to make the creation of new evaluations a more streamlined process. This will also help reduce the benchmark-to-benchmark variation in style.

97 MATHEMATICS AND COMPUTING↗

Electrophoresis demonstration on Apollo 16

Free fluid electrophoresis, a process used to separate particulate species according to surface charge, size, or shape was suggested as a promising technique to utilize the near zero gravity condition of space. Fluid electrophoresis on earth is disturbed by gravity-induced thermal convection and sedimentation. An apparatus was developed to demonstrate the principle and possible problems of electrophoresis on Apollo 14 and the separation boundary between red and blue dye was photographed in space. The basic operating elements of the Apollo 14 unit were used for a second flight demonstration on Apollo 16. Polystyrene latex particles of two different sizes were used to simulate the electrophoresis of large biological particles. The particle bands in space were extremely stable compared to ground operation because convection in the fluid was negligible. Electrophoresis of the polystyrene latex particle groups according to size was accomplished although electro-osmosis in the flight apparatus prevented the clear separation of two particle bands.

Snyder, R. S.↗

Development of a special purpose spacecraft interior coating. Phase 2

Numerous acrylic and epoxy modifiers for the fluorocarbon latex resin base were investigated. Optimum coatings were developed by modifying the fluorocarbon latex with an epoxy acrylic resin system. In addition, a number of other formulations, containing hard acrylics as modifiers, displayed attractive properties and potential for further improvements. The preferred formulations dried to touch in about one hour and were fully dried in about twenty four hours under normal room temperature and humidity conditions. In addition to physical and mechanical properties either comparable or superior to those of commercial solvent base polyurethane or polyester coatings, the preferred compositions meet the flammability and offgassing requirements specified by NASA.

Bartoszek, E. J.↗

Development of stable low-electroosmotic mobility coatings

Long-time rinsings of the Z6040-methlycellulose coating used successfully on the ASTP MA=011 experiment indicate the permanency of this coating is inadequate for continuous flowing systems. Two approaches are described for developing coatings which are stable under continuous fluid movement and which exhibit finite and predictable electroosmotic mobility values while being effective on different types of surfaces, such as glass, plastics, and ceramic alumina, such as is currently used as the electrophoresis channel in the GE-SPAR-CPE apparatus. The surface charge modification of polystyrene latex, especially by protein absorption, to be used as model materials for ground-based electrophoresis experiments, and the preliminary work directed towards the seeded polymerization of large-particle-size monodisperse latexes in a microgravity environment are discussed.

Vanderhoff, J. W.↗

An investigation of the motion of small particles as related to the formulation of zero gravity experiments

The nature of Brownian motion and historical theoretical investigations of the phenomemon are reviewed. The feasibility of using a laser anemometer to perform small particle experiments in an orbiting space laboratory was investigated using latex particles suspended in water in a plastic container. The optical equipment and the particle Doppler analysis processor are described. The values of the standard deviation obtained for the latex particle motion experiment were significantly large compared to corresponding velocity, therefore, their accuracy was suspect and no attempt was made to draw meaningful conclusions from the results.

Sastry, V. S.↗

Seeding subsonic, transonic and supersonic flows with 0.5 micron polystyrene spheres

Polystyrene latex particles have been successfully used as laser velocimetry seed material for flows in the Ames High Reynolds Channels (HR) 1 and 2, the pilot channel, and the one-foot low speed tunnel. These facilities provide test flows with Mach numbers from 0.1 to 3.0 and test section sizes from 4 inches by 6 inches to 18 inches by 24 inches. Tunnel mass flow in the HR-2 channel can approach 1000 lb/sec. The latex particles have the following favorable characteristics: size of 0.35 to 0.55 microns diameter; spherical shape; specific gravity of 1.05; excellent flow trackability; low toxicity; and low cost. they have the disadvantage of being packaged as an aqueous suspension which must be diluted and introduced into the test flow as an atomized mist. This must occur sufficiently far upstream of the test section to minimize flow disturbances and permit the liquid mist to evaporate before reaching the model. Several techniques which have been developed to accomplish satisfactory seeding will be described.

Seegmiller, H. L.↗