Search NASA⌕ Search

SEARCH · Search NASA

Results for “Leg”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Enhancing EV Charging Station Resilience with Multifunctional Converter Leg Integration

In this paper, a multifunctional converter leg is integrated into an EV charger’s power circuit to enhance EV charging station resilience under power electronics converter device faults and grid outages. In the event of a device fault, it substitutes the failed converter leg, maintaining operation. During a grid outage, it assists the system as a fourth leg to the front-end converter, enabling grid-forming capability to supply power to the charging station critical loads while allowing limited power vehicle charging. The proposed approach’s effectiveness under both front-end power converter device faults and grid outage scenarios are validated through simulation and controller hardware-in-the-loop results.

Pereira Pinto, Joao [ORNL]↗

Performance assessment of long-legged tightly-baffled divertor geometries in the ARC reactor concept

Extremely intense power exhaust channels are projected for tokamak-based fusion power reactors; a means to handle them remains to be demonstrated. Advanced divertor configurations have been proposed as potential solutions. Recent modelling of tightly baffled, long-legged divertor geometries for the divertor test tokamak concept, ADX, has shown that these concepts may access passively stable, fully detached regimes over a broad range of parameters. The question remains as to how such divertors may perform in a reactor setting. To explore this, numerical simulations are performed with UEDGE for the long-legged divertor geometry proposed for the ARC pilot plant conceptual design - a device with projected heat flux power width (λq||) of 0.4 mm and power exhaust of 93 MW - first for a simplified Super-X divertor configuration (SXD) and then for the actual X-point target divertor (XPTD) being proposed. It is found that the SXD, combined with 0.5% fixed-fraction neon impurity concentration, can produce passively stable, detached divertor regimes for power exhausts in the range of 80-108 MW - fully accommodating ARC's power exhaust. The XPTD configuration is found to reduce the strike-point temperature by a factor of ~10 compared to the SXD for small separations (~1.4λq||) between main and divertor X-point magnetic flux surfaces. Even greater potential reductions are identified for reducing separations to ~1λq|| or less. The power handling response is found to be insensitive to the level of cross-field convective or diffusive transport assumed in the divertor leg. By raising the separatrix density by a factor of 1.5, stable fully detached divertor solutions are obtained that fully accommodate the ARC exhaust power without impurity seeding. To our knowledge, this is the first time an impurity-free divertor power handling scenario has been obtained in edge modelling for a tokamak fusion power reactor with λq|| of 0.4 mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of changes in leg volume parameters, and orthostatic tolerance in response to lower body negative pressure during 28-days exposure to zero gravity Skylab 2

The design of the leg volume measuring system employed for the M092 portion of the Skylab missions required the development of a system sensitive to large and small volume changes at the calf of the leg. These changes in volume were produced in response to the orthostatic stress of a Lower Body Negative Pressure Device (LBNPD) or by venous occlusion. The cardiovascular responses of the Apollo crewman associated with the postflight evaluations indicate varying decrements of orthostatic tolerance. The postflight changes indicate a slightly diminished ability of the cardiovascular system to function effectively against gravity following exposure to weightlessness. The objective of the Skylab LBNP experiments (M092) was to provide information about the magnitude and time course of the cardiovascular changes associated with prolonged periods of exposure to weightlessness. The equipment, signal processing, and analysis of the leg volume data obtained from the M092 experiment of the Skylab 2 Mission are described.

Barnett, R. D.↗

Hemodynamic Studies of the Legs Under Weightlessness

Significant among the medical findings following prolonged space flight are reduced orthostatic tolerance and ergometric work capacity. Changes in hemodynamics of the legs with increased blood pooling and reduction in cardiac output must be considered one of the most probable causes of these effects. Concern for the above plus the observed marked tissue changes occurring in the legs during flight prompted the addition of several procedures to evaluate hemodynamic changes in the leg; resting arterial blood flow, venous compliance and muscle pumping were investigated. In so far as possible, the initial reaction to pressure in the smallest possible vein segment was examined.

William E Thornton↗

Tool Blunts Cotter Pin Legs for Safety

Jaws on new insertion tool contain upset point and anvil. Point forces cotter-pin legs into loop as it engages anvil. Cotter pin before insertion consists of loop and straight shaft composed of two legs welded together as tips. After insertion, welded legs have been shaped into loop. Tool used to prevent bent loose ends of cotter pins from scratching workers' fingers or cutting and entangling wires.

Stein, J. A.↗

Prevention of metabolic alterations caused by suspension hypokinesia in leg muscles of rats

Rats were subjected to tail-cast suspension hypokinesia for 6 days with one leg immobilized in dorsal flexion by casting. Control animals were also tail-casted. The soleus, gastrocnemius and plantaris muscles of uncasted hypokinetic legs were smaller than control muscles. Dorsal flexion prevented atrophy of these muscles and caused the soleus to hypertrophy. The anterior muscles were unaffected by hypokinesia. The smaller size of the soleus of the uncasted leg relative to the dorsal flexed and weight bearing limbs correlated with slower protein synthesis and faster proteolysis. The capacity of this muscle to synthesize glutamine (gln), which carries nitrogenous waste from muscle was also measured. Although tissue homogenates showed higher activities of gln synthetase, the rate of de novo synthesis was not altered in intact muscle but the tissue ratio of gln/glutamate was decreased. Glutamate and ATP were not limiting for gln synthesis, but availability of ammonia may be a limiting factor for this process in hypokinesia.

Tischler, M. E.↗

Effect of hand-arm exercise on venous blood constituents during leg exercise

Contributions by ancillary hand and arm actions to the changes in blood constituents effected by leg exercises on cycle ergometer were assessed. Static or dynamic hand-arm exercises were added to the leg exercise (50 percent VO2 peak)-only control regimens for the subjects (19-27 yr old men) in the two experimental groups. Antecubital venous blood was analyzed at times 0, 15, and 30 min (T0, T15, and T30) for serum Na(+), K(+), osmolality, albumin, total CA(2+), and glucose; blood hemoglobin, hematocrit, and lactic acid; and change in plasma volume. Only glucose and lactate values were affected by additional arm exercise. Glucose decreased 4 percent at T15 and T30 after static exercise, and by 2 percent at T15 (with no change at T30) after dynamic arm exercise. Conversely, lactic acid increased by 20 percent at T30 after static exercise, and by 14 percent by T15 and 6 percent at T30 after dynamic arm exercise. It is concluded that additional arm movements, performed usually when gripping the handle-bar on the cycle ergometer, could introduce significant errors in measured venous concentrations of glucose and lactate in the leg-exercised subjects.

Wong, N.↗

Leg muscle volume during 30-day 6-degree head-down bed rest with isotonic and isokinetic exercise training

Magnetic resonance imaging (MRI) was used to compare the effect of two modes of lower-extremity exercise training on the mass (volume) of posterior leg group (PLG) muscles (soleus, flexor hallucis longus, tibialis posterior, lateral and medial gastrocnemius, and flexor digitorum longus) on 19 men (ages 32-42 years) subjected to intense dynamic-isotonic (ITE, cycle ergometer, number of subjects (N) = 7), isokinetic (IKE, torque egrometer, N = 7), and no exercise (NOE, N = 5) training for 60 min/day during head-down bed rest (HDBR). Total volume of the PLG muscles decreased (p less than 0.05) similarly: ITE = 4.3 +/- SE 1.6%, IKE = 7.7 +/- 1.6%, and NOE = 6.3 +/- 0.8%; combined volume (N = 19) loss was 6.1 +/- 0.9%. Ranges of volume changes were 2.6% to -9.0% (ITE), -2.1% to -14.9% (IKE), and -3.4% to -8/1% (NOE). Correlation coefficients (r) of muscle volume versus thickness measured with ultrasonography were: ITE r + 0.79 (p less than 0.05), IKE r = 0.27 (not significant (NS)), and NOE r = 0.63 (NS). Leg-muscle volume and thickness were highly correlated (r = 0.79) when plasma volume was maintained during HDBR with ITE. Thus, neither intensive lower extremity ITE nor IKE training influence the normal non-exercised posterior leg muscle atrophy during HDBR. The relationship of muscle volume and thickness may depend on the mode of exercise training associated with the maintenance of plasma volume.

Greenleaf, J. E.↗

Leg Vascular Responsiveness During Acute Orthostasis Following Simulated Weightlessness

Ten men (35-49 years old) underwent lower body negative pressure (LBNP) exposures before and offer 10 d of continuous 6 degrees head-down bedrest in order to predict the effect of weightlessness on the responsiveness of leg vasculature to an orthostatic stress. Heart rate (HR), mean arterial blood pressure (MAP), and Impedance rheographic indices of arterial pulse volume (APV) of the legs were measured during rest and at 1 min at -30 mm Hg LBNP. Bedrest-induced deconditioning was manifested by decreases (p less than 0.06) in plasma volume (17%), peak oxygen uptake (16%), and LBNP tolerance (17%). Resting HR was unchanged after bedrest, but HR was higher (p less than 0.05) at 1 min of -30 mm Hg LBNP after, compared with before bedrest. Responses of MAP to -30 mm Hg LBNP were not altered by bodrest. Resting APV was decreased (p less than 0.05) by simulated weightlessness. However, APV was reduced (p less than 0.05) from rest to 1 min -30 mm Hg LBNP by the same relative magnitude before and after bodrest (-21.4 +/- 3.4% and -20.5 +/- 2.7%, respectively). We conclude that peripheral arterial vasoconstriction, as indicated by reductions in APV during LBNP, was not affected by bedrest. These results suggest that there was no apparent alteration in responsiveness of the leg vasculature following simulated weightlessness. Therefore, it appears unlikely that control mechanisms of peripheral resistance contribute significantly to reduced orthostatic tolerance following space-flight.

Blamick, Cynthia A.↗

Cooperative Exploration of Rough Martian Terrains with the "Scorpion" Legged Robot as an Adjunct to a Rover.

NASA needs autonomous robotic exploration of difficult (rough and/or steep) scientifically interesting Martian terrains. Concepts involving distributed autonomy for cooperative robotic exploration are key to enabling new scientific objectives in robotic missions. We propose to utilize a legged robot as an adjunct scout to a rover for access to difficult - scientifically interesting - terrains (rocky areas, slopes, cliffs). Our final mission scenario involves the Ames rover platform "K9" and Scorpion acting together to explore a steep cliff, with the Scorpion robot rappelling down using the K9 as an anchor as well as mission planner and executive. Cooperation concepts, including wheeled rappelling robots have been proposed before. Now we propose to test the combined advantages of a wheeled vehicle with a legged scout as well as the advantages of merging of high level planning and execution with biologically inspired, behavior based robotics. We propose to use the 8-legged, multifunctional autonomous robot platform Scorpion that is currently capable of: Walking on different terrains (rocks, sand, grass, ...). Perceiving its environment and modifying its behavioral pattern accordingly. These capabilities would be extended to enable the Scorpion to: communicate and cooperate with a partner robot; climb over rocks, rubble piles, and objects with structural features. This will be done in the context of exploration of rough terrains in the neighborhood of the rover, but inaccessible to it, culminating in the added capability of rappelling down a steep cliff for both vertical and horizontal terrain observation.

Colombano, Silvano P.↗

Motion of 3-6 keV Nonthermal Sources Along the Legs of a Flare Loop

Observations of nonthermal X-ray sources me critical to studying electron acceleration and transport in solar flares. Strong thermal emission radiated from the preheated plasma before the flare impulsive phase often makes it difficult to detect low-energy X-ray sources that are produced by relatively low-energy nonthermal electrons. Knowledge of the distribution of these low-energy nonthermal electrons is particularly important in determining the total nonthermal electron energy in solar flares. We report on an 'early impulsive flare' in which impulsive hard X-ray emission was seen early in the flare before the soft X-ray emission had risen significantly, indicating limited plasma pre-heating. Early in the flare, RHESSI < 25 keV images show coronal sources that moved first downward and then upwards along the legs of a flare loop. In particular, the 3-6 keV source appeared as a single coronal source at the start of the flare, and then it involved into two coronal sources moving down along the two legs of the loop. After nearly reaching the two footpoints at the hard X-ray peak, the two sources moved back up to the looptop again. RHESSI images and light curves all indicate that nonthermal emission dominated at energies as low as 3-6 keV. We suggest that the evolution of both the spectral index and the low-energy cutoff of the injected electron distribution could result in the accelerated electrons reaching a lower altitude along the legs of the dense flare loop and hence result in the observed downward and upward motions of the nonthermal sources.

Sui, Linhui↗

Study of effect of PWR cold leg temperature gradient on reactor core condition

Effects of temperature and flow gradients in Westinghouse designed three-loop Pressurized Water Reactor (PWR) cold legs, the piping between the main coolant pump and the reactor vessel, were evaluated using Computational Fluid Dynamics (CFD) code STAR CCM+ and coupled neutronic and thermal-hydraulic (T/H) code system VERA. In the parametric study, several symmetric and asymmetric temperature gradients that were significantly larger than those observed from plant measurements were applied to the cold leg inlets for comparison with the base case without any temperature gradient. A CFD model using the STAR-CCM+ code was developed for a portion of the RCS region between the Reactor Coolant Pump (RCP) and the core inlet based on previously validated modeling approach. The CFD simulation results were processed for the temperature and flow rate distributions at the core inlet as input to the VERA calculations. The VERA code system consists of COBRA-TF (CTF) for thermal-hydraulics, MPACT for reactor physics and neutron transport, and ORIGEN for isotopic depletion. The VERA model was for depletion calculations of a high-burnup loading pattern with the reactor core in pin-by-pin and subchannel resolution. The results of the study indicate that the postulated temperature gradients within the PWR cold legs do not result in any significant changes in the core inlet temperature distributions and the core power distributions during the reactor operation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Reduction of Random Uncertainty in Differential Temperature Measurements Using Common Leg Thermocouples

The uncertainty quantification of random error is considered for common leg thermocouples (i.e., where one thermoelement is shared along the length of the TC for all other TC junctions present). The uncertainty is presented for both a common leg and individual, separate leg thermocouples. For Type K thermocouples a reduction in uncertainty by up to 3x is capable when differential temperatures, ?T, are within 150°C, and diminishes to little to no improvement above 150°C.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Optical diagnostic design for measuring the radiation front with a mid-leg pumped divertor on DIII-D

The design of an optical diagnostic system to localize the radiation front in a mid-leg pumped divertor configuration on DIII-D is presented. Divertor detachment is a key mechanism for handling power exhaust in tokamaks, and mid-leg pumping offers a promising approach to radiatively dissipate power while maintaining acceptable core performance. To predict the location of the radiation front and design a spectroscopic diagnostic to measure its position, a database of SOLPS-ITER simulations across a range of input powers and gas puffing rates representative of DIII-D operation was employed. These simulations provide self-consistent plasma backgrounds for a Cherab-Raysect synthetic diagnostic framework, which incorporates detailed tokamak geometry and physically accurate ray-tracing. Synthetic simulations of optical sightlines and viewing cone geometry were used to calculate line-integrated emission from the plasma, particularly of the C III 465 nm line, to serve as a proxy for the T e ≈ 7 − 10 eV temperature region associated with the onset and evolution of divertor detachment. Neutral deuterium emission is also evaluated for comparison. The synthetic diagnostic is used to assess the performance of existing DIII-D optical systems, including filterscopes and the Multichord Divertor Spectrometer, and to optimize line-of-sight placement within mechanical and installation constraints. The results provide quantitative guidance for diagnostic implementation on DIII-D and demonstrate the advantage of integrated synthetic diagnostics for divertor design studies and future advanced divertor concepts.

Cherab↗

Energy and particle balance during plasma detachment in a long-leg divertor configuration

Abstract Comprehensive studies of energy and particle balances in the transition to plasma detachment in an alternative divertor configuration with long outer legs are shown. Numerical simulations are performed with the 2D code suite SOLPS 4.3, using a disconnected double null grid with narrow, tightly baffled long poloidal leg divertors at the outer lower target and outer upper target. A particle count scan is performed using the ‘closed gas box’ model, where the tunable parameter in the simulations is the total number of deuterium particles in the simulation space and all other parameters are held fixed, including a constant input power and trace neon impurity radiation, to assess the physics of the transition to detachment in the system as the particle count increases. Three main aspects of the physics of divertor detachment are addressed: the criteria for the local onset of divertor detachment in each of the divertors, the distribution of heat flux and other plasma parameters between the four divertors as each divertor transitions to detachment, and the role of perpendicular transport in the transition to the detached regime. A synergistic mechanism by which the cross-field transport is reduced by factors associated with the onset of plasma recombination effects is identified. These results are compared to the existing understanding of the physics of the transition to plasma detachment in standard divertors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of outer divertor leg detachment on the high field side scrape-off layer in DIII-D and ASDEX Upgrade

In this work, evidence is presented that detachment of the outer divertor leg leads to a reduction of electron density and neutral pressure in the high-field side (HFS) scrape-off layer (SOL) of the ASDEX Upgrade (AUG) and DIII-D tokamaks with ion $B$ x $∇B$ drift directed toward the X-point (favorable configuration). These results are observed across multiple diagnostics and without the use of impurity seeding to reach detachment. In AUG, outer divertor leg detachment correlates with a decrease in electron density near the separatrix at the inner midplane, measured with HFS reflectometry. A concurrent reduction in inner divertor density and neutral pressure at the inner target is observed using divertor Thomson scattering and neutral pressure gauges. These effects are present in both L- and H-mode plasmas. In DIII-D, a similar reduction is detected through analysis of line-integrated hydrogenic emission measured by multiple diagnostics in the HFS SOL close to the separatrix. The consistent trends in both devices indicate that high electron density and strong hydrogenic emissivity in the HFS SOL are common features of H-mode plasmas in the favorable configuration, independent of wall material and divertor geometry. In L-mode plasmas, the reduction in electron density and neutral pressure is not observed in DIII-D, possibly due to differences in wall material. These results emphasize the importance of the divertor state in determining the two-dimensional neutral distribution and edge fueling.

detachment↗

A Grid-Forming Split-Phase Three-Leg Inverter with Unbalanced Loading and Active Power Decoupling

This paper presents a split-phase three-leg inverter that regulates 180-degree phase-shifted AC voltages to support residential house loads under unbalanced loading conditions and decouples double line frequency power pulsation by utilizing the third half-bridge switching leg. The active power decoupling function is added without extra active switching components. The control feasibility and effectiveness are verified through MATLAB Simulink simulation and controller hardware-in-the-loop test.

Kim, Namwon [ORNL] (ORCID:0000000200438489)↗

Dip leg plug formation evaluation and abatement testing in support of the H-Canyon accelerated basin de-inventory

As requested in the Technical Task Request (TTR), the Savannah River National Laboratory (SRNL) performed testing on the current typical bubbler dip leg design used in the H-Area Canyon (HCA). The TTR has a functional classification of General Services. Testing was initiated to ascertain if the plugging described in the TTR could be reproduced and, if so, to obtain general metrics on the resulting plugging dynamics, and evaluate possible mitigating methods, including design changes and cleaning/purging protocols. The bubblers were to be suspended in a simulant typical of H-Canyon solutions containing aluminum nitrate and silica at a temperature of 25°C using a nominal bubbler air flowrate of 7.5 SCFH. Emphasis was placed on minimizing equipment changes necessary to accomplish the mitigations, as equipment changes in the existing facility would be costly. Testing evolved into four (4) phases, concluding that plugging could indeed be reproduced (believed to be attributed to localized evaporation and bridging of crystals in the dip legs). During testing, plug formation information was obtained, including time, pressure, and temperature traces leading to plugging were defined; solution compositions leading to plugging were determined, and various physical characteristics (visual and mechanical) of the crystallized plug were obtained.

42 ENGINEERING↗