Search NASA⌕ Search

SEARCH · Search NASA

Results for “Level-1 trigger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

49 records · Page 3

Performance of the ATLAS RPC detector and Level-1 muon barrel trigger at √(s)=13 TeV

The ATLAS experiment at the Large Hadron Collider (LHC) employs a trigger system consisting of a first-level hardware trigger (L1) and a software-based high-level trigger. The L1 muon trigger system selects muon candidates, assigns them to the correct LHC bunch crossing and classifies them into one of six transverse-momentum threshold classes. The L1 muon trigger system uses resistive-plate chambers (RPCs) to generate the muon-induced trigger signals in the central (barrel) region of the ATLAS detector. The ATLAS RPCs are arranged in six concentric layers and operate in a toroidal magnetic field with a bending power of 1.5 to 5.5 Tm. The RPC detector consists of about 3700 gas volumes with a total surface area of more than 4000 m2. This paper reports on the performance of the RPC detector and L1 muon barrel trigger using 60.8 fb-1 of proton-proton collision data recorded by the ATLAS experiment in 2018 at a centre-of-mass energy of 13 TeV. Detector and trigger performance are studied using Z boson decays into a muon pair. Measurements of the RPC detector response, efficiency, and time resolution are reported. Measurements of the L1 muon barrel trigger efficiencies and rates are presented, along with measurements of the properties of the selected sample of muon candidates. Measurements of the RPC currents, counting rates and mean avalanche charge are performed using zero-bias collisions. Finally, RPC detector response and efficiency are studied at different high voltage and front-end discriminator threshold settings in order to extrapolate detector response to the higher luminosity expected for the High Luminosity LHC.

47 OTHER INSTRUMENTATION↗

High Energy Physics Research at the Energy Frontier with the CMS Experiment

The physics analysis goals are to continue improving upon the search for the Higgs to dimuon decay using the CMS experiment at the LHC to further improve the Higgs coupling measurement with the additional data from LHC Run 3, and to explore searches for long-lived particles that reach the muon system of CMS using new Level-1 muon triggers the group is developing. An additional physics goal is to further develop the science case for a novel muonion collider. The experimental goals are to continue operational support of the CMS Endcap Muon Track Finder, a key component of the CMS Level-1 trigger system. The group also proposes to continue its leadership role in muon triggering for the HL-LHC upgrade through algorithm and electronics R&D. Finally, Acosta will continue as CMS Trigger Co-Coordinator responsible for the High Level Trigger system of CMS, lead the EMTF project, and serve as USCMS Trigger Operations Level-2 manager.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam test performance of a prototype module with Short Strip ASICs for the CMS HL-LHC tracker upgrade

The Short Strip ASIC (SSA) is one of the four front-end chips designed for the upgrade of the CMS Outer Tracker for the High Luminosity LHC. Together with the Macro-Pixel ASIC (MPA) it will instrument modules containing a strip and a macro-pixel sensor stacked on top of each other. The SSA provides both full readout of the strip hit information when triggered, and, together with the MPA, correlated clusters called stubs from the two sensors for use by the CMS Level-1 (L1) trigger system. Results from the first prototype module consisting of a sensor and two SSA chips are presented. The prototype module has been characterized at the Fermilab Test Beam Facility using a 120 GeV proton beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3

The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of ℒ = 2 × 10 34 cm -2 s -1 was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of ℒ = 2 × 10 34 cm -2 s -1 , with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark Matter and Track Triggering with the CMS Experiment (Final Report)

This report summarizes the progress from DOE Early Career Award entitled “Dark Matter and Track Triggering with the CMS Experiment”. The first major goal of the project was to establish a sensitive Dark Matter (DM) search program for the CMS experiment in Run-2 of the LHC. Two related strategies were developed to accomplish this goal. First, we designed and executed searches for DM produced in association with heavy flavor quark pairs, top/anti-top (ttbar) and bottom/anti-bottom (bbbar). In addition, we sought to maximize the power of Run-2 DM searches through the development of a statistical combination of all major search channels within a consistent theoretical framework. The results of these aspects of the project are detailed in Section 1. The second major goal of the project was to develop a real-time “Level-1” tracking trigger system for the high-luminosity LHC (HL-LHC) CMS upgrade. Charged particle tracking in the first stage of the CMS trigger will be crucial for surviving the high-pileup environment expected at the HL-LHC. The L1 tracking trigger must process all front-end hit data sent from the inner Tracker and will have just 4us to output track primitives to the downstream L1 trigger without data loss. Our development of the CMS tracking trigger is described in Section 2. The team supported by the award is given in Section 3. The project resulted in 10 peer reviewed publications, a graduate student thesis, and contributions to the CMS Phase-2 Tracker Technical Design Report, as is detailed in Section 4. Our development work for the CMS tracking trigger has been integrated in the backend system architecture for the Tracker upgrade.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of prototype GE1/1 chambers for the CMS muon spectrometer upgrade

The high-luminosity phase of the Large Hadron Collider (HL-LHC) will result in ten times higher particle background than measured during the first phase of LHC operation. In order to fully exploit the highly-demanding operating conditions during HL-LHC, the Compact Muon Solenoid (CMS) Collaboration will use Gas Electron Multiplier (GEM) detector technology. The technology will be integrated into the innermost region of the forward muon spectrometer of CMS as an additional muon station called GE1/1. The primary purpose of this auxiliary station is to help in muon reconstruction and to control level-1 muon trigger rates in the pseudo-rapidity region 1.6 ≤ |η| ≤ 2.2. The new station will contain trapezoidal-shaped GEM detectors called GE1/1 chambers. The design of these chambers is finalized, and the installation is in progress during the Long Shutdown phase two (LS-2) that started in 2019. Several full-size prototypes were built and operated successfully in various test beams at CERN. Here, we describe performance measurements such as gain, efficiency, and time resolution of these prototype chambers, developed after years of R&D, and summarize their behavior in different gas compositions as a function of the applied voltage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam test performance of prototype silicon detectors for the Outer Tracker for the Phase-2 Upgrade of CMS

A new CMS tracker detector will be installed for operation at the High Luminosity LHC (HL-LHC). This detector comprises modules with two closely spaced parallel sensor plates and front-end ASICs capable of transmitting tracking information to the CMS Level-1 (L1) trigger at the 40 MHz beam crossing rate. The inclusion of tracking information in the L1 trigger decision will be essential for selecting events of interest efficiently at the HL-LHC. The CMS Binary Chip (CBC)has been designed to read out and correlate hits from pairs of tracker sensors, forming so called track stubs. For the first time, a prototype irradiated module and a full-sized module, both equipped with the version 2 of the CBC, have been operated in test beam facilities. The efficiency of the stub finding logic of the modules for various angles of incidence has been studied. The ability of the modules to reject tracks with transverse momentum less than 2 GeV has been demonstrated. For modules built with irradiated sensors, no significant drop in the stub finding performance has been observed. Results from the beam tests are described in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and construction of the CMS Outer Tracker for the Phase-2 Upgrade

he High Luminosity LHC (HL-LHC) is expected to deliver an integrated luminosity of $3000-4000$~fb$^{-1}$ after 10 years of operation with peak instantaneous luminosity reaching about $5-7.5\times10^{34}$cm$^{-2}$s$^{-1}$. During Long Shutdown 3, several components of the CMS detector will undergo major changes, called Phase-2 upgrade, to be able to operate in the challenging environment of the HL-LHC. The current CMS silicon strip tracker has to be replaced with a new detector. The Phase-2 Outer Tracker (OT) will have higher radiation tolerance, higher granularity, and the capability to handle higher data rates compared to the current system. Another key feature of the OT will be to provide tracking information to the Level-1 (L1) trigger, allowing trigger rates to be kept at a sustainable level without sacrificing physics potential. For this, the OT will be made out of modules with two closely spaced sensors read out by front-end ASICs, which can correlate hits in the two sensors creating short track segments called stubs. The stubs will be used for tracking in the L1 track finder. The modules come in two flavors: strip-strip (2S) and pixel-strip (PS), which contain different sensor configurations and multiple ASICs. In this contribution, the design of the CMS Phase-2 OT, the technological choices, and the quality assurance (QA) procedures used to ensure the functionality of the modules will be reported. The contribution will cover the first results with pre-production devices and the different aspects taken into account during the QA: from fulfilling the precision specification of the module assembly procedure to ensuring the proper communication between the different ASICs on the module. The module noise performance is also checked and the full module functionality is verified at different temperatures.

Zoi, Irene↗

Design of a Level-1 Long-Lived Particle Trigger in the CMS Hadron Calorimeter

The Hadron Calorimeter (HCAL) in the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) was recently upgraded for Run 3 to introduce depth segmentation and online timing measurements, expanding the physics capabilities. In particular, the augmentation of the calorimeter information at the hardware trigger level enables quick identification and recording of long-lived particle decays using lower thresholds on energy-based event quantities. The depth segmentation and online timing capabilities are utilized in novel HCAL-based hardware-level triggers to identify displaced and delayed long-lived particles (LLPs), either decaying inside the calorimeter volume or arriving at a delayed time. This increases the sensitivity to LLP decays occurring up to almost 6 m from the collision point. This two-pronged calorimeter trigger approach leverages the new capabilities of the CMS HCAL to expand the phase space accessible in ongoing LLP searches. These triggers were deployed for Run 3 of the LHC, beginning data-taking in 2022, and we review the trigger implementation and calibration.

Kopp, Gillian Baron [Princeton University, NJ (Uni↗

Exploring the Energy Frontier through Precision Tests and Fast Tracking with the CMS Detector (Final Technical Report)

This Early Career Award supported a research program using the CMS experiment at the CERN LHC to probe physics beyond the Standard Model in the top quark and Higgs boson sectors, alongside detector and trigger developments for the High-Luminosity LHC (HL-LHC) upgrade. The program (i) searched for charged lepton flavor violation (LFV) in the top quark sector with the full CMS Run-2 data set, placing the world’s strongest limits to date on the $t → eµq\ (q = u/c)$ branching fraction; (ii) developed preliminary analysis methods toward a boosted $t\bar{t}H(b\bar{b})$ measurement of the top quark Yukawa coupling and its CP properties; (iii) made leading contributions to the hardware-based Level-1 (L1) track finding system for the upgraded CMS detector for HL-LHC; and (iv) developed novel L1 trigger algorithms, notably a displaced vertex trigger enabling new searches for exotic long-lived particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Production and tests of the ADDC for the Micromegas detector of the ATLAS New Small Wheel

The Large Hadron Collider (LHC) at CERN will perform a series of upgrades to allow luminosity increases during the next physics runs expected from 2022 on. These will also significantly increase the trigger rates of all the detectors. As part of the ATLAS Phase-I upgrade, the current Small Wheel muon detectors will be replaced with state-of-the-art New Small Wheel (NSW) detectors to cope with the increased luminosity of the LHC. The Address in Real Time Data Driver Card (ADDC) is designed to transmit the trigger data from the resistive Micro-Mesh Gaseous Structure (Micromegas) detectors of the NSW. The ART ASIC on the ADDC is a customdesigned chip to receive theAddress in Real Time (ART) signals from theVMMfront-end ASIC and perform hit-selection processing. The processed trigger data is then sent to the Trigger Processor (TP) through optical links. A total of 512 ADDCs will be installed on the detector close to the front-end boards. Therefore, those cards must be able to work properly in a high radiation and magnetic field environment. Furthermore, after four rounds of prototyping, the ADDC production was launched in January of 2019. 600 ADDC boards have been produced and tested with an automated test stand. This test setup can simulate the front-end signals and provide "Level-1 Data Driver Card" (L1DDC) functions as well as part of the TP functions. Thus, the ADDC functionality and stability can be verified without the remaining NSW electronics. This paper describes the ADDC hardware prototype development, radiation and integration testing, and the ADDC automated production test procedure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real Time Data Analysis With the ATLAS Trigger at the LHC in Run-2

The trigger selection capabilities of the ATLAS detector have been significantly enhanced for the LHC Run- 2 in order to cope with the higher event rates and with the large number of simultaneous interactions (pile-up) per protonproton bunch crossing. A new hardware system, designed to analyse real time event-topologies at Level-1 came to full use in 2017. A hardware-based track reconstruction system, expected to be used real-time in 2018, is designed to provide track information to the high-level software trigger at its full input rate. The high-level trigger selections are largely relying on offline-like reconstruction techniques, and in some cases multivariate analysis methods. Despite the sudden change in LHC operations during the second half of 2017, which caused an increase in pile-up and therefore also in CPU usage of the trigger algorithms, the set of triggers (so called trigger menu) running online has undergone only minor modifications thanks to the robustness and redundancy of the trigger system, and the use of a levelling luminosity scheme in agreement with LHC and other experiments. Here, this presentation gives a brief yet comprehensive review of the real-time performance of the ATLAS trigger system in 2017. Considerations will be presented on the most relevant parameters of the trigger (efficiency to collect signal and output data rate) as well as details on some aspects of the algorithms which are run real-time on the High Level Trigger CPU farm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)↗