Exclusive measurements of light fragment production at forward angles in Ne-Pb and Ne-NaF collisions at E/A=400 MeV and 800 MeV

Emission of light fragments at small angles is studied in relativistic heavy ion collisions using the Diogene plastic wall for both symmetrical and non-symmetrical target-projectile systems with 400 MeV per nucleon and 800 MeV per nucleon incident neon nuclei. Efficiency of multiplicity measurements in the small angle range for the selection of central or peripheral collisions is confirmed for asymmetric systems. Differential production cross sections of Z = 1 fragments show evidence for the existence of two emitting sources. The apparent temperature of each source is obtained from comparison with a thermodynamical model.

NASA Discipline Number 04-10↗

DDFRG2: Double-Differential FRaGmentation Model with Pion Production

A set of Double-Differential FRaGmentation (DDFRG) models for production of fragments from nucleon-nucleus and nucleus-nucleus collisions, relevant to space radiation, is currently being developed. DDFRG1 was a previous model developed for production of protons and light ions. A new model for pion production is developed in the present work and is called DDFRG2, which is based upon thermal production of pions from a central fireball source. The Lorentzinvariant double-differential cross section is calculated in the central fireball frame, and is Lorentz transformed to the laboratory frame, which results in a closed-form analytic formula involving no numerical integration, and which can be run very efficiently in radiation transport codes. The Lorentz-invariant double-differential cross section is then integrated over angle to give the singledifferential energy spectral distribution. Two versions of the DDFRG2 pion production are developed, namely DDFRG2-SIMPLE and DDFRG2-FULL. Both versions produce pion production Lorentz-invariant double-differential cross sections and also pion production single-differential spectral (energy) distributions. The SIMPLE version contains only one adjustable parameter. The FULL version contains three additional adjustable parameters. Both DDFRG2 versions are compared to over 1,000 data points. The SIMPLE version describes the p + 12 C → π − much better than the current HZETRN pion model. For other reactions, the SIMPLE version is of comparable quality to the current HZETRN pion model compared to data. For both the p + 12 C → π − reaction and all other reactions, DDFRG2-FULL describes the data much more accurately than the current HZETRN pion model.

John W. Norbury↗

Heavy-ion fusion cross section formula and barrier height distribution

Methods for obtaining fusion cross section formulas are discussed, especially for those that take on an empirical form. A new expression starting with σ( E) = $\frac{1}{E}$ $\int ^{E}_{E_0}$ $(\int^{E'}_{E_0} B (E^\shortparallel) dE^\shortparallel)dE'$ has been explored. Here, B(E) is a reasonable, assumed function of the barrier height distribution, $\frac{d^2 (\sigma E)}{dE^2}$. Further, the resulting analytic cross section formula reproduces very well the excitation functions for many light and heavy fusion systems across wide energy ranges, when B(E) is assumed to be a multi-Gaussian function. This study offers an improved determination of the fusion barrier height distribution over other numerical techniques.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Triangular cross-section grating couplers for integrated quantum nanophotonic hardware in silicon carbide

We design, fabricate, and characterize fishbone grating couplers for triangular cross-section photonics in silicon carbide compatible with color center integration. The periodic and aperiodic grating coupler designs are optimized to outcouple up to 31% of light in the fundamental TE mode of a triangular waveguide. The devices are fabricated using an ion beam etching process in a 4H–SiC sample implanted with NV center ensembles. The room-temperature transmission and the cryogenic NV center photoluminescence collection measurements indicate experimental grating coupler efficiency of up to 24%. This result provides a scalable method to efficiently extract color center light from SiC quantum nanophotonic devices to free-space optics.

Saha, Pranta↗

Cross-sections for 43 Sc, 44 m Sc, and 44 g Sc from two heavy ion reactions

Two different heavy ion reactions were used to produce 43 Sc (t$_{\frac12}$ = 3.891 h), 44g Sc (t$_{\frac12}$ = 4.042 h), and 44m Sc (t$_{\frac12}$ = 58.61 h) among other stable or long-lived chemically separable products. Production cross sections for 19 F + 27 Al and the reverse kinematic reaction 35 Cl + nat B were measured using an MC-SNICS ion source and the Notre Dame FN Tandem Accelerator. 19 F beams from 35 to 60 MeV were produced with beam currents between 40–80 pnA and 35 Cl beams were produced at six entrance energies with comparable beam currents. This work reports nuclear reaction cross sections 27 Al ( 19 F, x) 43 Sc, 27 Al ( 19 F, pn) 44g Sc, and 27 Al ( 19 F, pn) 44m Sc at six energies between 35 and 60 MeV lab energy. Cross sections within the same energy range were measured for 27 Al ( 19 F, 3pn) 42 K and 27 Al ( 19 F, 3p) 43 K. Comparative measurements were performed for the same compound nucleus produced from nat B( 35 Cl, x) 43 Sc, nat B( 35 Cl, pn) 44g Sc, and nat B( 35 Cl, pn) 44m Sc. The measured thin target cross sections show an overestimation by several statistical models for the scandium radioisotopes. This is corroborated by the measured thick target production rates for both entrance channels. This may be due to angular momentum effects of a heavy ion entrance channel compared to light-ion production, but additional work is required to understand this discrepancy. Finally, these measurements demonstrate that the medically useful 43 Sc, 44g Sc, and 44m Sc radioisotopes can be free of the long-lived contaminant 46 Sc without the use of enriched targets, using heavy ion beams and robust target materials.

07 ISOTOPE AND RADIATION SOURCES↗

Electron-optical observations of ordered FeNi in the Estherville meteorite

Electron optical studies of the ordered FeNi (taenite) phase in the Estherville meteorite are reported. A thin section of the meteorite containing a large area of continuous anisotropic taenite was studied by crossed polar reflected light microscopy, and electron probe microanalysis, transmission electron microscopy, scanning transmission electron microscopy and X-ray energy dispersive spectrometry. Results reveal the presence of preferentially ion-etched regions of clear taenite corresponding to single crystals, with superlattice reflections in the fundamental FeNi reciprocal lattice arising from long-range ordering. The presence of antiphase domain boundaries within the regions also confirms the presence of ordering. It is thus proposed that clear taenite in the Estherville meteorite contains regions of ordered FeNi phase in a disordered gamma-phase matrix.

Mehta, S.↗

Laser-Induced-Emission Spectroscopy In Hg/Ar Discharge

Laser-induced-emission (LIE) spectroscopy used to probe low-pressure mercury/argon discharge to determine influence of mercury atoms in metastable 6(Sup3)P(Sub2) state on emission of light from discharge. LIE used to study all excitation processes affected by metastable population, including possible effects on excitation of atoms, ions, and buffer gas. Technique applied to emissions of other plasmas. Provides data used to make more-accurate models of such emissions, exploited by lighting and laser industries and by laboratories studying discharges. Also useful in making quantitative measurements of relative rates and cross sections of direct and two-step collisional processes involving metastable level.

Maleki, Lutfollah↗

Transport of Light Ions in Matter

A recent set of light ion experiments are analyzed using the Green's function method of solving the Boltzmann equation for ions of high charge and energy (the GRNTRN transport code) and the NUCFRG2 fragmentation database generator code. Although the NUCFRG2 code reasonably represents the fragmentation of heavy ions, the effects of light ion fragmentation requires a more detailed nuclear model including shell structure and short range correlations appearing as tightly bound clusters in the light ion nucleus. The most recent NTJCFRG2 code is augmented with a quasielastic alpha knockout model and semiempirical adjustments (up to 30 percent in charge removal) in the fragmentation process allowing reasonable agreement with the experiments to be obtained. A final resolution of the appropriate cross sections must await the full development of a coupled channel reaction model in which shell structure and clustering can be accurately evaluated.

Wilson, J. W.↗

The Zero-Degree Detector System for Fragmentation Studies

The measurement of nuclear fragmentation cross sections requires the detection and identification of individual projectile fragments. If light and heavy fragments are recorded in 'ne same detector, it may be impossible distinguish the signal from the light fragment. To overcome this problem, we have developed the Zero-Degree Detector System. The ZDDS enables the measurement of cross sections for light fragment production by using pixelated detectors to separately measure the signals of each fragment. The system has been used to measure the fragmentation of beams as heavy as Fe at the NASA Space Radiation Laboratory at Brookhaven National Laboratory and the Heavy Ion Medical Accelerator in Chiba, Japan.

Adams, J. H., Jr.↗

Structural and optical properties of Sm{sup 3+}-doped borate glasses for luminescent applications

In this work, most interesting optical investigations are carried out with the glass composition (20 − x) CdCO{sub 3} + 15 Li{sub 2}CO{sub 3} + 15 Na{sub 2}CO{sub 3} + 50 H{sub 3}BO{sub 3} + xSm{sub 2}O{sub 3} (where x = 0.1, 0.5, 1.0, 3.0, 4.0 and 5.0 mol%) prepared with conservative melt-quenching technique. DSC verifies the annealing temperature and thermal stability of the prepared glass. X-ray diffraction technique is employed to inspect the amorphous structure of the glasses. FTIR technique helps to view the vibrational band positions of the host material. For optical studies, optical absorption and emission measurements are used. From the absorption spectra, Judd–Ofelt (JO) parameters (Ω{sub 2}, Ω{sub 4}, Ω{sub 6}), rms value of oscillator strength (δ{sub rms}), nephelauxetic parameter ( β-bar ), bonding parameter (δ) and optical band gaps are evaluated. Radiative properties such as radiative transition probabilities (A{sub T}), branching ratios (β{sub cal}, β{sub exp}) and stimulated emission cross section (σ{sub emi}) are calculated using JO theory. The higher stimulated emission cross section (14.39 × 10{sup −22} cm{sup 2}), optical gain (36.69 × 10{sup −25} cm{sup 2} s) indicate that 1.0 mol% of Sm{sup 3+}-doped borate glass would be a potential gain medium for solid state laser application at 603 nm. Color coordinates of the glasses located in the reddish-orange region could be useful for white light-emitting application.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CLARION2-TRINITY: A Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions

The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminum Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7–54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $\gamma$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors (efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Lastly, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from 16 O + 18 O fusion-evaporation, and PID and Doppler-corrected -ray spectra from 48 Ti + 12 C Coulomb excitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancing Cross-Sectional Scanning Electron Microscopy of Perovskite Solar Cells

Organic–inorganic perovskites are an emerging class of photovoltaic materials. Despite achieving power conversion efficiencies surpassing 26%, the challenge of perovskite stability including degradation during exposure to operational conditions such as light, heat, humidity, water, oxygen, and electric fields is well known. Related, perovskite instability has limited high-resolution electron imaging and characterization techniques that can be used for understanding degradation mechanisms. Furthermore, we demonstrate perovskite device cross-section preparation using mechanical polishing in a water-free environment with cryogenic Ar ion milling. Scanning electron microscopy was then used in both backscattered electron and secondary electron imaging modes to obtain information about layer structure, grain aggregate structure, and compositional heterogeneity. Monte Carlo CASINO simulations inform optimum beam conditions and image acquisition parameters and the effects of accelerating voltage, dwell times, and frame averaging for practical image acquisition are reported.

14 SOLAR ENERGY↗

A Short-Lived Isotope Counting System (SLICS) to measure reaction cross sections producing light, beta-decaying nuclei on OMEGA

A new activation detector optimized for short-lived isotopes was designed, installed, and tested on OMEGA. The Short-Lived Isotope Counting System (SLICS) can be positioned as close as 35 cm from the OMEGA target chamber center in a ten-inch-manipulator. Stable target samples can be mounted on the front end of the detector assembly to undergo triton-, deuteron-, or neutron-induced reactions that produce short-lived reaction products that beta decay. The emitted betas are detected in a phoswich configuration to eliminate the gamma background. The detector is optimized for isotopes with half-lives from 150 ms to 20 s, filling a gap in OMEGA’s current activation detectors for isotopes with half-lives >5 min. In a pilot study, SLICS achieved an efficiency of 24.5% ± 2.0% for counting 8Li, with a total of 505.8 ± 4.4 qualifying events. Using the existing triton laser-ion acceleration platform on OMEGA, this detector can be used to measure rarely studied tritium-induced reactions on light nuclei with an estimated uncertainty of 12%. As a result, the design of the detector and its performance during a first experiment employing deuterium as a surrogate will be discussed.

Beta spectrometry↗

Morphometrics of cellular damage in mice testis receiving X-ray and high-energy particle irradiation

Murine tests were exposed to single, low doses of either X-ray, helium, or argon radiation. Animals were sacrificed seventy-two hours later. Testes were fixed for transmission electron microscopy (TEM) and sectioned at either 60 nm for TEM observation or at 2 micron for counting using routine light microscope methods. Counts of the total population of surviving spermatogonia, including all type A cells, intermediate, and type B cells, were taken from tubule cross sections identified as Stage 6 and Stage 1 according to spermatogonial configuration. The surviving fraction of spermatogonia as compared to control, S/S sub o, was calculated for each dose. For both ions and X-rays, there was a rapid decline in survival at dose levels of .10 to .15 Gy in Stage 6 tubules. This was followed by a more gradual decrease in population. At higher doses, 0.30 Gy for argon and 0.80 Gy for helium and X-rays, the cell survival rates declined rapidly. Pre-leptotene spermatocytes in Stage 1 tubules exhibited a different survival curve indicating the extreme radio-sensitivity of type B spermatogonia. Data verify that the seminiferous tubules are composed of a heterogeneous population of cells with different radio-sensitivities and that these differences are manifested even at very low doses.

Sapp, Walter J.↗

Monte Carlo track structure for radiation biology and space applications

Over the past two decades event by event Monte Carlo track structure codes have increasingly been used for biophysical modelling and radiotherapy. Advent of these codes has helped to shed light on many aspects of microdosimetry and mechanism of damage by ionising radiation in the cell. These codes have continuously been modified to include new improved cross sections and computational techniques. This paper provides a summary of input data for ionizations, excitations and elastic scattering cross sections for event by event Monte Carlo track structure simulations for electrons and ions in the form of parametric equations, which makes it easy to reproduce the data. Stopping power and radial distribution of dose are presented for ions and compared with experimental data. A model is described for simulation of full slowing down of proton tracks in water in the range 1 keV to 1 MeV. Modelling and calculations are presented for the response of a TEPC proportional counter irradiated with 5 MeV alpha-particles. Distributions are presented for the wall and wall-less counters. Data shows contribution of indirect effects to the lineal energy distribution for the wall counters responses even at such a low ion energy.

NASA Center JSC↗

Average-atom calculations of bound-free and free-free cross sections in dense plasmas

Cross sections for photo-induced bound-free and free-free transitions in plasmas are evaluated in the average-atom approximation and applied to determine opacities of dense plasmas of light elements. Parameters characterizing the plasmas (chemical potential, average ionic charge, free electron density, bound and continuum wave functions, and occupation numbers) are obtained from the average-atom model. Lowest-order calculations of the free-free cross sections, which diverge in the low-frequency limit, are regularized by accounting for the finite electron-ion relaxation time. The resulting analysis provides the basis for average-atom studies of plasma opacities. Such studies are presented for dense lithium, beryllium, boron, and carbon. Applications are given to Rosseland mean opacities of dense hydrogen and deuterium plasmas and to comparisons of free-free to bound-free opacities in shock-compressed plasmas. Average-atom cross section and opacity calculations are extended to plasmas consisting of more than one ionic species, boron nitride, polystyrene, and a composite H, He, C plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The X-Ray Spectrum of the Supernova Remnant 1E 0102-72.3

In this letter we present the soft X-ray (5-35A) spectrum of the supernova remnant (SNR) IE 0102-72.3 in the Small Magellanic Cloud, acquired by the reflection grating spectrometer (RGS) aboard ESA's XMM-Newton Observatory. This extended-source X-ray spectrum of unprecedented spectral resolution (lambda/Delta(lambda) approx. 300) permits, for the first time, unabiguous identification and measurement of isolated emission lines and line complexes alike. The diagnostic power of performing spectroscopy using groups of emission lines from single ions is exemplified. In particular, the bright Lyman and helium series lines for light elements (C VI, O VII, O VIII, Ne IX, Ne X and possibly Mg XI & Mg XII) show peculiar ratios, where the values [1s - np] / [1s - (n + l)p] are systematically weaker than expected for electron impact excitation. These measured ratios resemble signatures of recombining or charge exchanging plasmas. We argue that charge exchange, given its large cross section and evidence for inhomogeneous media within the SNR, is a likely mechanism for the observed emission. Also. the well known temperature diagnostics G(T(sub e)) = (i + f)/r of helium- like triplets (O VII & Ne IX) indicate high temperatures, well above the maximum emission temperature T(sub m) for each ion, and consistent with a purely ionizing plasma. The density diagnostics R(n(sub e)) = f / i meanwhile, are consistent with the low density limit, as expected.

Rasmussen, Andrew P.↗

Accurate universal parameterization of absorption cross sections III--light systems

Our prior nuclear absorption cross sections model [R.K. Tripathi, F.A. Cucinotta, J.W. Wilson, Nucl. Instr. and Meth. B 117 (1996) 347; R.K. Tripathi, J.W. Wilson, F.A. Cucinotta, Nucl. Instr. and Meth. B 129 (1997) 11] is extended for light systems (A < or = 4) where either both projectile and target are light particles or one is light particle and the other is medium or heavy nucleus. The agreement with experiment is excellent for these cases as well. Present work in combination with our original model provides a comprehensive picture of absorption cross sections for light, medium and heavy systems. As a result the extended model can reliably be used in all studies where there is a need for absorption cross sections.

NASA Discipline Radiation Health↗